{"id":5729,"date":"2025-07-18T00:00:00","date_gmt":"2025-07-18T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/shielded-vs-unshielded-rj45-connectors\/"},"modified":"2026-06-22T08:57:31","modified_gmt":"2026-06-22T08:57:31","slug":"shielded-vs-unshielded-rj45-connectors","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/vi\/knowledge-center\/shielded-vs-unshielded-rj45-connectors","title":{"rendered":"\u0110\u1ea7u n\u1ed1i RJ45 c\u00f3 v\u1ecf b\u1ecdc so v\u1edbi \u0111\u1ea7u n\u1ed1i RJ45 kh\u00f4ng c\u00f3 v\u1ecf b\u1ecdc: S\u1ef1 kh\u00e1c bi\u1ec7t l\u00e0 g\u00ec?"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31a6b4d7bcd74ef5bb88d89abc61f310.webp\" alt=\"Shielded vs. Unshielded RJ45 Connectors\" class=\"wp-image-5727\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31a6b4d7bcd74ef5bb88d89abc61f310.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31a6b4d7bcd74ef5bb88d89abc61f310-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31a6b4d7bcd74ef5bb88d89abc61f310-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31a6b4d7bcd74ef5bb88d89abc61f310-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31a6b4d7bcd74ef5bb88d89abc61f310-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">RJ45 connectors are a critical component in Ethernet networking, widely used to connect computers, routers, switches, and other devices. When choosing the right RJ45 connector (this article focuses on PCB-mount RJ45 connectors ) one key decision is whether to use <strong>shielded<\/strong> or <strong>unshielded<\/strong> versions. This choice affects electromagnetic performance, mechanical design, and the connector\u2019s suitability for various application environments..<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Are Shielded RJ45 Connectors?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-17492-integrated-rj45-connector.htm?ca=199&amp;cv=1172\">Shielded RJ45 connectors<\/a> incorporate a <strong>metal shield<\/strong> or <strong>grounding shell<\/strong> around the plastic housing of the connector. This shield serves two primary purposes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Reduce Electromagnetic Interference (EMI)<\/strong> from external sources<\/p><\/li>\n\n\n\n<li><p><strong>Contain Radiated Emissions<\/strong> from within the device<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Shielded connectors are typically used with <strong>STP\/FTP Ethernet cables<\/strong> and must be properly grounded through the PCB or chassis to be effective.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u2705 Examples of Shielded RJ45 Jacks:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a href=\"https:\/\/www.l-p.com\/products\/486085.htm\" target=\"_blank\" rel=\"\"><strong>LPJG47047A4NL<\/strong><\/a> \u2013 2&#215;4 Shielded RJ45 Magnetic Jacks Support PoE+ <\/p><\/li>\n\n\n\n<li><p><a href=\"https:\/\/www.l-p.com\/products\/474436.htm\" target=\"_blank\" rel=\"\"><strong>LPJ16264A28NL<\/strong><\/a> \u2013 8P8C RJ45 PCB Jack With Shield EMI Tabs<\/p><\/li>\n\n\n\n<li><p><a href=\"https:\/\/www.l-p.com\/products\/474344.htm\" target=\"_blank\" rel=\"\"><strong>LPJ16258AENL<\/strong><\/a> \u2013 10\/100 Base-T PoE RJ45 Connector with Integrated Magnetics<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">What Are Unshielded RJ45 Connectors?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/buy-unshielded.htm\">Unshielded RJ45 connectors<\/a> do <strong>not include any metal shield<\/strong> on the outer shell. They are fully enclosed in plastic, making them lighter, easier to install, and more cost-effective. These connectors are typically used with <strong>UTP cables<\/strong> in low-interference environments such as home routers, consumer electronics, or office equipment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Despite lacking shielding, <strong>unshielded RJ45 connectors can still include integrated magnetics and LED indicators<\/strong>, enabling them to meet the electrical requirements of Ethernet standards like 10\/100\/1000Base-T.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u2705 Examples of Unshielded RJ45 Jacks:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a href=\"https:\/\/www.l-p.com\/products\/471100.htm\" target=\"_blank\" rel=\"\"><strong>LPJ0012NNL<\/strong><\/a> \u2013 1&#215;1 Port Unshielded RJ45 Jack Tab Down<\/p><\/li>\n\n\n\n<li><p><a href=\"https:\/\/www.l-p.com\/products\/460427.htm\" target=\"_blank\" rel=\"\"><strong>LPJE180NNL<\/strong><\/a> \u2013 RJ45 Modular Jack without Magnetics and LED<\/p><\/li>\n\n\n\n<li><p><a href=\"https:\/\/www.l-p.com\/products\/469435.htm\" target=\"_blank\" rel=\"\"><strong>LPJE101NNL<\/strong><\/a> \u2013 Compact unshielded 8P8C Jack Tab UP<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Key Differences Between Shielded and Unshielded RJ45 Connectors<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"608\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/36a0bfca67e749f7ac27f63ca73cca65-1024x608.webp\" alt=\"Key Differences Between Shielded and Unshielded RJ45 Connectors\" class=\"wp-image-5728\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/36a0bfca67e749f7ac27f63ca73cca65-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/36a0bfca67e749f7ac27f63ca73cca65-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/36a0bfca67e749f7ac27f63ca73cca65-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/36a0bfca67e749f7ac27f63ca73cca65-18x12.webp 18w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/36a0bfca67e749f7ac27f63ca73cca65.webp 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0110\u1eb7c t\u00ednh<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Shielded RJ45 Connectors<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Unshielded RJ45 Connectors<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>EMI\/RFI Protection<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2705 High<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u274c Low<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>External Housing<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Metal shielded<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Full plastic<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Signal Integrity in Harsh Environments<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Xu\u1ea5t s\u1eafc<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Basic<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Cost<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Cao h\u01a1n<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lower<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Typical Cable Type<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>STP \/ FTP<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>UTP<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Grounding Required<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>C\u00f3<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>No<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Tr\u01b0\u1eddng h\u1ee3p s\u1eed d\u1ee5ng<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Industrial, PoE switches, medical, telecom<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Home gateways, printers, consumer electronics<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">How to Choose Between Shielded and Unshielded RJ45<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Khi ch\u1ecdn b\u1ed9 n\u1ed1i RJ45 cho b\u1ea3ng m\u1ea1ch in (PCB) c\u1ee7a b\u1ea1n, h\u00e3y c\u00e2n nh\u1eafc c\u00e1c y\u1ebfu t\u1ed1 sau:<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\u2705 Choose <strong>Shielded RJ45<\/strong> khi:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Device is used in <a href=\"https:\/\/resourceslp.szlogic.cn\/vi\/glossary\/what-is-electromagnetic-interference\/\" target=\"_blank\" rel=\"\"><strong>EMI<\/strong><\/a><strong>-sensitive environments<\/strong> (factories, data centers, power systems)<\/p><\/li>\n\n\n\n<li><p>You are designing for <a href=\"https:\/\/resourceslp.szlogic.cn\/vi\/knowledge-center\/faqs-link-pp-poe-rj45-connector\/\" target=\"_blank\" rel=\"\"><strong>Cung c\u1ea5p \u0111i\u1ec7n qua Ethernet<\/strong><\/a><strong> (PoE\/PoE+)<\/strong><\/p><\/li>\n\n\n\n<li><p>The product will be installed near <strong>high-frequency equipment<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">\u2705 Choose <strong>Unshielded RJ45<\/strong> Modular Jack when:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>T\u1ed1i \u01b0u h\u00f3a chi ph\u00ed l\u00e0 \u01b0u ti\u00ean h\u00e0ng \u0111\u1ea7u<\/p><\/li>\n\n\n\n<li><p>The environment is <strong>low in EMI\/RFI<\/strong><\/p><\/li>\n\n\n\n<li><p>Ease of assembly and <strong>simplified PCB layout<\/strong> is desired<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Application Scenarios<\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 237px;\"\/><col style=\"width: 212px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"237\"><p>Ng\u00e0nh c\u00f4ng nghi\u1ec7p<\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"212\"><p>Recommended Type<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>L\u00fd do<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"237\"><p>T\u1ef1 \u0111\u1ed9ng h\u00f3a c\u00f4ng nghi\u1ec7p<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"212\"><p>Shielded<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Strong EMI resistance needed<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"237\"><p>\u0110i\u1ec7n t\u1eed ti\u00eau d\u00f9ng<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"212\"><p>Unshielded<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lightweight, cost-effective<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"237\"><p>Telecom \/ PoE Switches<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"212\"><p>Shielded<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Power and signal stability<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"237\"><p>Office Networking<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"212\"><p>Unshielded<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Quiet EMI environment<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"237\"><p>Thi\u1ebft b\u1ecb y t\u1ebf<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"212\"><p>Shielded<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Signal integrity is critical<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>K\u1ebft lu\u1eadn<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Both <strong>shielded<\/strong> and <strong>unshielded RJ45 connectors<\/strong> have their roles in modern Ethernet networking. The decision depends on EMI environment, device application, cost constraints, and assembly design. When building reliable, standards-compliant Ethernet ports into your hardware, be sure to match the connector\u2019s shielding level with your real-world application requirements.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">D\u00f9 b\u1ea1n \u0111ang thi\u1ebft k\u1ebf m\u1ed9t thi\u1ebft b\u1ecb ti\u00eau d\u00f9ng nh\u1ecf g\u1ecdn hay m\u1ed9t b\u1ed9 chuy\u1ec3n m\u1ea1ch \u0111\u1ea1t chu\u1ea9n c\u00f4ng nghi\u1ec7p, th\u00ec vi\u1ec7c l\u1ef1a ch\u1ecdn \u0111\u00fang <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-17492-integrated-rj45-connector.htm\">B\u1ed9 n\u1ed1i RJ45<\/a> is a critical choice for long-term performance and compliance.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\ud83d\udd0e Frequently Asked Questions (FAQ)<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Q1: Can an unshielded RJ45 connector include magnetics and LEDs?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong> \u0110\u00fang v\u1eady. C\u00e1c b\u1ed9 n\u1ed1i RJ45 kh\u00f4ng \u0111\u01b0\u1ee3c che ch\u1eafn c\u00f3 th\u1ec3 t\u00edch h\u1ee3p \u0111\u1ea7y \u0111\u1ee7 c\u00e1c th\u00e0nh ph\u1ea7n t\u1eeb t\u00ednh (v\u00ed d\u1ee5 nh\u01b0 bi\u1ebfn \u00e1p c\u00e1ch ly v\u00e0 cu\u1ed9n ch\u1ed1ng nhi\u1ec5u ch\u1ebf \u0111\u1ed9 chung) c\u0169ng nh\u01b0 \u0111\u00e8n LED ch\u1ec9 th\u1ecb. Vi\u1ec7c thi\u1ebfu l\u1edbp che ch\u1eafn ch\u1ec9 \u1ea3nh h\u01b0\u1edfng \u0111\u1ebfn hi\u1ec7u su\u1ea5t ch\u1ed1ng nhi\u1ec5u \u0111i\u1ec7n t\u1eeb (EMI), ch\u1ee9 kh\u00f4ng \u1ea3nh h\u01b0\u1edfng \u0111\u1ebfn ch\u1ee9c n\u0103ng ho\u1ea1t \u0111\u1ed9ng.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Q2: Is shielding required for Ethernet compliance?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong> No. Ethernet standards like IEEE 802.3 do not mandate shielding. However, shielding is recommended in high-EMI environments to maintain signal integrity and reduce emissions.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Q3: Will using a shielded RJ45 with unshielded cable cause problems?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong> It may reduce the effectiveness of the shield. For optimal EMI performance, the connector and cable should both be shielded and properly grounded.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Q4: Do shielded RJ45 connectors require a PCB ground connection?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong> \u0110\u00fang v\u1eady. V\u1ecf kim lo\u1ea1i c\u1ee7a b\u1ed9 n\u1ed1i RJ45 \u0111\u01b0\u1ee3c che ch\u1eafn ph\u1ea3i \u0111\u01b0\u1ee3c n\u1ed1i \u0111i\u1ec7n v\u1edbi m\u1eb7t ph\u1eb3ng \u0111\u1ea5t (ground plane) c\u1ee7a b\u1ea3ng m\u1ea1ch in (PCB) ho\u1eb7c v\u1ecf thi\u1ebft b\u1ecb \u0111\u1ec3 cung c\u1ea5p kh\u1ea3 n\u0103ng b\u1ea3o v\u1ec7 ch\u1ed1ng nhi\u1ec5u \u0111i\u1ec7n t\u1eeb (EMI). N\u1ebfu kh\u00f4ng \u0111\u01b0\u1ee3c n\u1ed1i \u0111\u1ea5t, l\u1edbp che ch\u1eafn s\u1ebd tr\u1edf n\u00ean v\u00f4 hi\u1ec7u.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Q5: What are the signs that I need a shielded RJ45 instead of unshielded?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong> Consider a shielded RJ45 if:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Your product operates in environments with motors, RF transmitters, or power supplies<\/p><\/li>\n\n\n\n<li><p>You\u2019ve experienced EMI-related performance issues<\/p><\/li>\n\n\n\n<li><p>Your device needs to meet stringent EMC (Electromagnetic Compatibility) regulations<\/p><\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Q6: How do I identify if a connector is shielded or unshielded?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong> Visual inspection can help:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Shielded RJ45s<\/strong> have a metal shell around the port, often silver in color, and may include grounding tabs.<\/p><\/li>\n\n\n\n<li><p><strong>Unshielded RJ45s<\/strong> are typically all-plastic and do not have any metal shell.<\/p><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>\u0110\u1ea7u n\u1ed1i RJ45 c\u00f3 v\u1ecf b\u1ecdc so v\u1edbi \u0111\u1ea7u n\u1ed1i RJ45 kh\u00f4ng c\u00f3 v\u1ecf b\u1ecdc: So s\u00e1nh kh\u1ea3 n\u0103ng b\u1ea3o v\u1ec7, chi ph\u00ed v\u00e0 c\u00e1c tr\u01b0\u1eddng h\u1ee3p s\u1eed d\u1ee5ng ph\u00f9 h\u1ee3p nh\u1ea5t \u0111\u1ec3 l\u1ef1a ch\u1ecdn \u0111\u1ea7u n\u1ed1i RJ45 \u0111\u00fang cho m\u00f4i tr\u01b0\u1eddng m\u1ea1ng c\u1ee7a b\u1ea1n.<\/p>","protected":false},"author":1,"featured_media":5727,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[22,25],"class_list":["post-5729","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-integrated-rj45-connectors","tag-modular-jack"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/vi\/wp-json\/wp\/v2\/posts\/5729","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/vi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/vi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/vi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/vi\/wp-json\/wp\/v2\/comments?post=5729"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/vi\/wp-json\/wp\/v2\/posts\/5729\/revisions"}],"predecessor-version":[{"id":11327,"href":"https:\/\/resourceslp.szlogic.cn\/vi\/wp-json\/wp\/v2\/posts\/5729\/revisions\/11327"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/vi\/wp-json\/wp\/v2\/media\/5727"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/vi\/wp-json\/wp\/v2\/media?parent=5729"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/vi\/wp-json\/wp\/v2\/categories?post=5729"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/vi\/wp-json\/wp\/v2\/tags?post=5729"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}