{"id":5729,"date":"2025-07-18T00:00:00","date_gmt":"2025-07-18T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/shielded-vs-unshielded-rj45-connectors\/"},"modified":"2026-06-22T08:57:31","modified_gmt":"2026-06-22T08:57:31","slug":"shielded-vs-unshielded-rj45-connectors","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/pt\/knowledge-center\/shielded-vs-unshielded-rj45-connectors","title":{"rendered":"Conectores RJ45 Blindados vs. N\u00e3o Blindados: Qual \u00e9 a Diferen\u00e7a?"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31a6b4d7bcd74ef5bb88d89abc61f310.webp\" alt=\"Shielded vs. Unshielded RJ45 Connectors\" class=\"wp-image-5727\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31a6b4d7bcd74ef5bb88d89abc61f310.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31a6b4d7bcd74ef5bb88d89abc61f310-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31a6b4d7bcd74ef5bb88d89abc61f310-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31a6b4d7bcd74ef5bb88d89abc61f310-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31a6b4d7bcd74ef5bb88d89abc61f310-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Os conectores RJ45 s\u00e3o um componente cr\u00edtico nas redes Ethernet, amplamente utilizados para conectar computadores, roteadores, switches e outros dispositivos. Ao escolher o conector RJ45 adequado (este artigo concentra-se em conectores RJ45 para montagem em PCB), uma decis\u00e3o fundamental \u00e9 se utilizar <strong>blindados<\/strong> or <strong>n\u00e3o blindados<\/strong> vers\u00f5es. Essa escolha afeta o desempenho eletromagn\u00e9tico, o projeto mec\u00e2nico e a adequa\u00e7\u00e3o do conector a diversos ambientes de aplica\u00e7\u00e3o.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">O que s\u00e3o conectores RJ45 blindados?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-17492-integrated-rj45-connector.htm?ca=199&amp;cv=1172\">Conectores RJ45 blindados<\/a> incorporam um <strong>escudo met\u00e1lico<\/strong> or <strong>carca\u00e7a de aterramento<\/strong> ao redor da carca\u00e7a pl\u00e1stica do conector. Esse escudo tem duas finalidades principais:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Reduzir interfer\u00eancia eletromagn\u00e9tica (EMI)<\/strong> proveniente de fontes externas<\/p><\/li>\n\n\n\n<li><p><strong>Conter emiss\u00f5es irradiadas<\/strong> provenientes do interior do dispositivo<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Conectores blindados s\u00e3o normalmente utilizados com <strong>cabos Ethernet STP\/FTP<\/strong> e devem ser aterrados adequadamente atrav\u00e9s da PCB ou do chassi para serem eficazes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u2705 Exemplos de tomadas RJ45 blindadas:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a href=\"https:\/\/www.l-p.com\/products\/486085.htm\" target=\"_blank\" rel=\"\"><strong>LPJG47047A4NL<\/strong><\/a> \u2013 Tomadas magn\u00e9ticas RJ45 blindadas 2\u00d74 com suporte PoE+ <\/p><\/li>\n\n\n\n<li><p><a href=\"https:\/\/www.l-p.com\/products\/474436.htm\" target=\"_blank\" rel=\"\"><strong>LPJ16264A28NL<\/strong><\/a> \u2013 Tomada RJ45 PCB 8P8C com escudo e abas EMI<\/p><\/li>\n\n\n\n<li><p><a href=\"https:\/\/www.l-p.com\/products\/474344.htm\" target=\"_blank\" rel=\"\"><strong>LPJ16258AENL<\/strong><\/a> \u2013 Conector RJ45 10\/100 Base-T com PoE e magn\u00e9ticos integrados<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">O que s\u00e3o conectores RJ45 n\u00e3o blindados?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/buy-unshielded.htm\">Conectores RJ45 n\u00e3o blindados<\/a> n\u00e3o <strong>incluem nenhum escudo met\u00e1lico<\/strong> na carca\u00e7a externa. Est\u00e3o totalmente encapsulados em pl\u00e1stico, tornando-os mais leves, mais f\u00e1ceis de instalar e mais econ\u00f4micos. Esses conectores s\u00e3o normalmente utilizados com <strong>cabos UTP<\/strong> em ambientes de baixa interfer\u00eancia, como roteadores dom\u00e9sticos, equipamentos eletr\u00f4nicos de consumo ou equipamentos de escrit\u00f3rio.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Apesar de n\u00e3o possu\u00edrem blindagem, <strong>as tomadas RJ45 n\u00e3o blindadas ainda podem incluir magn\u00e9ticos integrados e indicadores LED<\/strong>, permitindo-lhes atender aos requisitos el\u00e9tricos dos padr\u00f5es Ethernet, como 10\/100\/1000Base-T.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u2705 Exemplos de tomadas RJ45 n\u00e3o blindadas:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a href=\"https:\/\/www.l-p.com\/products\/471100.htm\" target=\"_blank\" rel=\"\"><strong>LPJ0012NNL<\/strong><\/a> \u2013 Tomada RJ45 n\u00e3o blindada 1\u00d71 com aba para baixo<\/p><\/li>\n\n\n\n<li><p><a href=\"https:\/\/www.l-p.com\/products\/460427.htm\" target=\"_blank\" rel=\"\"><strong>LPJE180NNL<\/strong><\/a> \u2013 Tomada modular RJ45 sem magn\u00e9ticos nem LED<\/p><\/li>\n\n\n\n<li><p><a href=\"https:\/\/www.l-p.com\/products\/469435.htm\" target=\"_blank\" rel=\"\"><strong>LPJE101NNL<\/strong><\/a> \u2013 Tomada compacta 8P8C n\u00e3o blindada com aba para cima<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Principais diferen\u00e7as entre conectores RJ45 blindados e n\u00e3o blindados<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"608\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/36a0bfca67e749f7ac27f63ca73cca65-1024x608.webp\" alt=\"Key Differences Between Shielded and Unshielded RJ45 Connectors\" class=\"wp-image-5728\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/36a0bfca67e749f7ac27f63ca73cca65-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/36a0bfca67e749f7ac27f63ca73cca65-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/36a0bfca67e749f7ac27f63ca73cca65-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/36a0bfca67e749f7ac27f63ca73cca65-18x12.webp 18w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/36a0bfca67e749f7ac27f63ca73cca65.webp 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Recurso<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Conectores RJ45 blindados<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Conectores RJ45 n\u00e3o blindados<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Prote\u00e7\u00e3o contra EMI\/RFI<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2705 Alta<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u274c Baixa<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Carca\u00e7a externa<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Blindada met\u00e1lica<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Pl\u00e1stico completo<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Integridade do sinal em ambientes agressivos<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Excelente<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>B\u00e1sico<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Cost<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Maior<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lower<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Tipo de Cabo T\u00edpico<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>STP \/ FTP<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>UTP<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Aterramento obrigat\u00f3rio<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Yes<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>No<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Caso de uso<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Industrial, switches PoE, m\u00e9dico, telecomunica\u00e7\u00f5es<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Gateways dom\u00e9sticos, impressoras, eletr\u00f4nicos de consumo<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Como escolher entre RJ45 blindado e n\u00e3o blindado<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ao selecionar um conector RJ45 para sua placa de circuito impresso (PCB), considere o seguinte:<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\u2705 Escolha <strong>RJ45 blindado<\/strong> when:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>O dispositivo \u00e9 utilizado em <a href=\"https:\/\/resourceslp.szlogic.cn\/pt\/glossary\/what-is-electromagnetic-interference\/\" target=\"_blank\" rel=\"\"><strong>EMI<\/strong><\/a><strong>-ambientes sens\u00edveis<\/strong> (f\u00e1bricas, centros de dados, sistemas de energia)<\/p><\/li>\n\n\n\n<li><p>Voc\u00ea est\u00e1 projetando para <a href=\"https:\/\/resourceslp.szlogic.cn\/pt\/knowledge-center\/faqs-link-pp-poe-rj45-connector\/\" target=\"_blank\" rel=\"\"><strong>Alimenta\u00e7\u00e3o sobre Ethernet<\/strong><\/a><strong> (PoE\/PoE+)<\/strong><\/p><\/li>\n\n\n\n<li><p>O produto ser\u00e1 instalado pr\u00f3ximo a <strong>equipamentos de alta frequ\u00eancia<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">\u2705 Escolha <strong>RJ45 n\u00e3o blindado<\/strong> Conector modular quando:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>A otimiza\u00e7\u00e3o de custos \u00e9 uma prioridade<\/p><\/li>\n\n\n\n<li><p>O ambiente \u00e9 <strong>com baixa interfer\u00eancia eletromagn\u00e9tica\/radiofrequ\u00eancia (EMI\/RFI)<\/strong><\/p><\/li>\n\n\n\n<li><p>Facilidade de montagem e <strong>layout simplificado da PCB<\/strong> s\u00e3o desejados<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Cen\u00e1rios de aplica\u00e7\u00e3o<\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 237px;\"\/><col style=\"width: 212px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"237\"><p>Ind\u00fastria<\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"212\"><p>Tipo recomendado<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Motivo<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"237\"><p>Automa\u00e7\u00e3o Industrial<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"212\"><p>Blindado<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Necess\u00e1ria forte resist\u00eancia \u00e0 EMI<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"237\"><p>Eletr\u00f3nica de Consumo<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"212\"><p>N\u00e3o blindado<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Leve e economicamente vantajoso<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"237\"><p>Telecomunica\u00e7\u00f5es \/ switches PoE<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"212\"><p>Blindado<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Estabilidade de energia e sinal<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"237\"><p>Redes de escrit\u00f3rio<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"212\"><p>N\u00e3o blindado<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Ambiente com baixa EMI<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"237\"><p>Dispositivos M\u00e9dicos<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"212\"><p>Blindado<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>A integridade do sinal \u00e9 cr\u00edtica<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Conclus\u00e3o<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ambos <strong>blindados<\/strong> and <strong>conectores RJ45 n\u00e3o blindados<\/strong> t\u00eam seus pap\u00e9is nas redes Ethernet modernas. A decis\u00e3o depende do ambiente de EMI, da aplica\u00e7\u00e3o do dispositivo, das restri\u00e7\u00f5es de custo e do projeto de montagem. Ao incorporar portas Ethernet confi\u00e1veis e compat\u00edveis com os padr\u00f5es ao seu hardware, certifique-se de alinhar o n\u00edvel de blindagem do conector com os requisitos reais da sua aplica\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Seja voc\u00ea projetando um dispositivo compacto para consumo ou um switch de grau industrial, a escolha correta <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-17492-integrated-rj45-connector.htm\">conector RJ45<\/a> \u00e9 fundamental para desempenho a longo prazo e conformidade.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\ud83d\udd0e Perguntas frequentes (FAQ)<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">P1: Um conector RJ45 n\u00e3o blindado pode incluir magn\u00e9ticos e LEDs?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R:<\/strong> Sim. Conectores RJ45 n\u00e3o blindados podem integrar totalmente magn\u00e9ticos (como transformadores de isolamento e filtros de modo comum) e indicadores LED. A aus\u00eancia de blindagem afeta apenas o desempenho contra EMI, n\u00e3o a funcionalidade.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">P2: A blindagem \u00e9 obrigat\u00f3ria para conformidade com Ethernet?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R:<\/strong> N\u00e3o. Padr\u00f5es Ethernet, como o IEEE 802.3, n\u00e3o exigem blindagem. Contudo, a blindagem \u00e9 recomendada em ambientes com alta EMI para manter a integridade do sinal e reduzir emiss\u00f5es.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">P3: Usar um RJ45 blindado com cabo n\u00e3o blindado causar\u00e1 problemas?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R:<\/strong> Pode reduzir a efic\u00e1cia da blindagem. Para um desempenho ideal contra EMI, o conector e o cabo devem ser ambos blindados e corretamente aterrados.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">P4: Conectores RJ45 blindados exigem uma conex\u00e3o de terra na placa de circuito impresso (PCB)?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R:<\/strong> Sim. A carca\u00e7a met\u00e1lica de um conector RJ45 blindado deve estar eletricamente conectada ao plano de terra da PCB ou ao chassi para fornecer prote\u00e7\u00e3o contra EMI. Sem aterramento, a blindagem \u00e9 ineficaz.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">P5: Quais s\u00e3o os sinais de que preciso de um conector RJ45 blindado em vez de um n\u00e3o blindado?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R:<\/strong> Considere um conector RJ45 blindado se:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Seu produto operar em ambientes com motores, transmissores de RF ou fontes de alimenta\u00e7\u00e3o<\/p><\/li>\n\n\n\n<li><p>Voc\u00ea j\u00e1 tiver experimentado problemas de desempenho relacionados \u00e0 EMI<\/p><\/li>\n\n\n\n<li><p>Seu dispositivo precisar cumprir regulamenta\u00e7\u00f5es rigorosas de CEM (Compatibilidade Eletromagn\u00e9tica)<\/p><\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">P6: Como identificar se um conector \u00e9 blindado ou n\u00e3o blindado?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R:<\/strong> A inspe\u00e7\u00e3o visual pode ajudar:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Conectores RJ45 blindados<\/strong> possuem uma carca\u00e7a met\u00e1lica ao redor da porta, geralmente na cor prata, e podem incluir abas de aterramento.<\/p><\/li>\n\n\n\n<li><p><strong>Conectores RJ45 n\u00e3o blindados<\/strong> s\u00e3o tipicamente totalmente pl\u00e1sticos e n\u00e3o possuem nenhuma carca\u00e7a met\u00e1lica.<\/p><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Conectores RJ45 blindados vs. n\u00e3o blindados: Compare prote\u00e7\u00e3o, custo e melhores usos para escolher os conectores RJ45 certos para o ambiente de rede.<\/p>","protected":false},"author":1,"featured_media":5727,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[22,25],"class_list":["post-5729","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-integrated-rj45-connectors","tag-modular-jack"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts\/5729","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/comments?post=5729"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts\/5729\/revisions"}],"predecessor-version":[{"id":11327,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts\/5729\/revisions\/11327"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/media\/5727"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/media?parent=5729"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/categories?post=5729"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/tags?post=5729"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}