{"id":5436,"date":"2025-08-15T00:00:00","date_gmt":"2025-08-15T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/psm4-vs-cwdm4-which-optical-transceiver-for-your-network\/"},"modified":"2026-06-22T08:25:49","modified_gmt":"2026-06-22T08:25:49","slug":"psm4-vs-cwdm4-which-optical-transceiver-for-your-network","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/pt\/knowledge-center\/psm4-vs-cwdm4-which-optical-transceiver-for-your-network","title":{"rendered":"PSM4 vs. CWDM4: Qual Transceptor \u00d3ptico \u00e9 Ideal para a Sua Rede"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9.webp\" alt=\"100G PSM4 VS CWDM4\" class=\"wp-image-5432\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">A demanda por conectividade de 100G em centros de dados e redes corporativas est\u00e1 explodindo. Escolher o certo<br> <strong>transceptor \u00f3ptico<\/strong> <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>(QSFP28 de 100G)<br><\/strong><\/a> \u00e9 fundamental para desempenho, custo, escalabilidade e efici\u00eancia energ\u00e9tica. Dois padr\u00f5es dominantes<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/knowledge-center\/multi-source-agreements-optical-transceivers\/\"><strong>MSA<\/strong><\/a> (Acordo Multi-Fornecedor) surgiram:<br> <strong>PSM4 (fibra monomodo paralela, 4 canais)<br><\/strong> and <strong>CWDM4 (multiplexa\u00e7\u00e3o por divis\u00e3o de comprimento de onda grosseira, 4 canais)<br><\/strong>. Embora ambos alcancem 100G a at\u00e9 2 km usando fibra monomodo,<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/knowledge-center\/what-is-single-mode-fiber-and-how-does-it-work\/\"><strong>(SMF)<\/strong><\/a>, suas tecnologias subjacentes e casos de uso ideais diferem significativamente. Compreender essas diferen\u00e7as entre transceptores de 100G \u00e9 essencial para otimizar redes de centro de dados e reduzir os custos de interconex\u00e3o \u00f3ptica.<br>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udd27 PSM4: Poder da Paraleliza\u00e7\u00e3o<br><\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"618\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda.webp\" alt=\"100G PSM4\" class=\"wp-image-5433\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda-300x155.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda-1024x527.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda-768x396.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda-18x9.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">O PSM4 (IEEE 802.3bm) adota uma abordagem paralela direta:<br><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Tecnologia:<\/strong> Utiliza 4 canais \u00f3pticos independentes (cada um a<br> <em>comprimento de onda de 1310 nm<\/em>).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fibra:<\/strong> Exige <strong>8 fibras<\/strong> (4 Tx, 4 Rx) \u2013 normalmente em um conector MPO-12.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Funcionamento:<br><\/strong> Cada canal transmite dados a 25 Gbps simultaneamente sobre seu par de fibras dedicado.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Vantagens:<\/strong> Projeto \u00f3ptico mais simples, potencialmente levando a menores custos de componentes e excelente isolamento de sinal.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fraquezas:<br><\/strong> Maior consumo de fibras, maior volume de cabos.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Ideal para:<br><\/strong> Alcance ultra-curto (\u2264 500 m) dentro de racks ou filas, cen\u00e1rios de conex\u00e3o direta de alta densidade onde a contagem de fibras n\u00e3o \u00e9 restri\u00e7\u00e3o prim\u00e1ria. Um m\u00f3dulo \u00f3ptico confi\u00e1vel<br> <strong>PSM4<br><\/strong> como a <strong>LINK-PP LQ-M31100-DR4C<br><\/strong> oferece desempenho consistente para essas exigentes<br> <strong>aplica\u00e7\u00f5es de \u00f3ptica paralela<br><\/strong>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83c\udf08 CWDM4: Engenhosidade dos Comprimentos de Onda<br><\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b.webp\" alt=\"100G CWDM4\" class=\"wp-image-5434\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">O CWDM4 (Especifica\u00e7\u00e3o MSA) aproveita a multiplexa\u00e7\u00e3o \u00f3ptica para economizar fibras:<br><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Tecnologia:<\/strong> Utiliza 4 comprimentos de onda diferentes CWDM (~1271 nm, 1291 nm, 1311 nm, 1331 nm) multiplexados em um<br> <em>\u00fanico<\/em> par de fibras.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fibra:<\/strong> Requer apenas<br> <strong>2 fibras<\/strong> (1 Tx, 1 Rx) \u2013 normalmente LC duplex.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Funcionamento:<br><\/strong> Um multiplexador (Mux) combina os 4 comprimentos de onda na fibra de transmiss\u00e3o; um demultiplexador (Demux) separa-os na extremidade de recep\u00e7\u00e3o.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Vantagens:<\/strong> Reduz drasticamente a contagem de fibras (4\u00d7 menos que o PSM4), cabos menores, gerenciamento de cabos mais f\u00e1cil e conectores LC padr\u00e3o.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fraquezas:<br><\/strong> Exige lasers e componentes Mux\/Demux mais complexos (e potencialmente mais caros).<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Ideal para:<br><\/strong> The <strong>ponto ideal para a maioria dos links de 100G de 2 km<br><\/strong> (por exemplo, interconex\u00e3o intra-centro de dados, links de campus). \u00c9 a solu\u00e7\u00e3o preferida para<br> <strong>efici\u00eancia de fibra CWDM4 <\/strong> and <strong>conectividade 100G econ\u00f4mica<\/strong>. A <strong>LINK-PP <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472577.htm\"><strong>LQ-CW100-FR4C<\/strong><\/a> \u00e9 projetado para m\u00e1xima confiabilidade nesses redes multiplexadas por comprimento de onda.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83e\udd4a Compara\u00e7\u00e3o direta: PSM4 vs. CWDM4 \u2013 As principais diferen\u00e7as<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Recurso<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>PSM4 (100G-PSM4)<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4 (100G-CWDM4)<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Vencedora em\u2026<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Tecnologia<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 canais paralelos em 1310 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 canais WDM (1271\/1291\/1311\/1331 nm)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Simplicidade (PSM4) \/ Efici\u00eancia de fibra (CWDM4)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Contagem de fibras<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>8 fibras<\/strong> (MPO-12)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>2 fibras<\/strong> (LC Duplex)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4<\/strong> (Economia significativa)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Alcance<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>At\u00e9 500 m (ideal), 2 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>At\u00e9 2 km (padr\u00e3o)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Empate (ambos suportam 2 km; PSM4 \u00e9 melhor \u2264 500 m)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Conector<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>MPO-12\/APC<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>LC Duplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4<\/strong> (Padr\u00e3o, gerenciamento mais f\u00e1cil)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Complexidade do laser<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Mais simples (4\u00d7 o mesmo \u03bb)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Mais complexo (4\u00d7 \u03bb diferentes, multiplexador\/demultiplexador)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>PSM4<\/strong> (Potencialmente menor custo)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Volume do cabo<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Maior (cabo mais grosso)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Menor (cabo mais fino)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Caso de Uso Prim\u00e1rio<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Alcance curto, alta densidade<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>ICI e DCI padr\u00e3o de 2 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Depende da dist\u00e2ncia\/necessidades de fibra<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Fator de custo (componentes)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Potencialmente menor custo do laser<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Potencialmente maior custo do laser + multiplexador\/demultiplexador<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Dependente do contexto<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Fator de custo (infraestrutura)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Maior (mais fibra\/cablagem)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Lower<\/strong> (Menos fibra\/cablagem)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4<\/strong> (Custo total da infraestrutura)<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83c\udfc6 Escolhendo seu campe\u00e3o: PSM4 ou CWDM4?<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px 0px 4px;\"><strong>Escolha o PSM4 se:<\/strong><\/p><ul><li><p style=\"margin: 0px;\">seus enlaces s\u00e3o <strong>muito curtos (\u2264 500 m)<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>a infraestrutura de fibra \u00e9 abundante e barata<\/strong>, e o volume do cabo n\u00e3o \u00e9 um problema relevante.<\/p><\/li><li><p style=\"margin: 0px;\">Voc\u00ea prioriza potenciais <strong>economias de custo nos componentes<\/strong> em vez da efici\u00eancia de fibra <em>para implanta\u00e7\u00f5es espec\u00edficas de curto alcance<\/em>.<\/p><\/li><li><p style=\"margin: 0px;\">Voc\u00ea precisa de <strong>\u00f3ptica paralela de alta densidade<\/strong> dentro de um espa\u00e7o restrito.<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>Escolha o CWDM4 se (a op\u00e7\u00e3o mais comum):<\/strong><\/p><ul><li><p style=\"margin: 0px;\">seus enlaces s\u00e3o <strong>at\u00e9 2 km<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>a conserva\u00e7\u00e3o de fibra \u00e9 cr\u00edtica<\/strong> (economiza custo e complexidade significativos).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Easier cable management<\/strong> com LC duplex \u00e9 preferida.<\/p><\/li><li><p style=\"margin: 0px;\">Voc\u00ea precisa de uma <strong>solu\u00e7\u00e3o padr\u00e3o e amplamente interoper\u00e1vel<\/strong> para interconex\u00f5es entre data centers (DCI) ou links de backbone empresarial.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Custo total da infraestrutura<\/strong> (fibra + cablagem + gerenciamento) \u00e9 um fator decisivo.<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\ud83d\udca1 Solu\u00e7\u00f5es LINK-PP: Projetadas para desempenho e valor<\/strong><br\/>Seja qual for o projeto de sua rede 100G \u2014 exigindo a efici\u00eancia paralela de <strong>PSM4<\/strong> ou o poder de multiplexa\u00e7\u00e3o por comprimento de onda de <strong>CWDM4<\/strong>,<a target=\"_blank\" rel=\"\" href=\"https:\/\/www.link-pp.com\/\"><strong> LINK-PP<\/strong><\/a> oferece solu\u00e7\u00f5es de alto desempenho e compat\u00edveis com o padr\u00e3o MSA:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Para paralelismo exigente de curto alcance:<\/strong> The <strong>transceptores LINK-PP PSM4<\/strong> oferecem desempenho robusto para \u00f3ptica 100G com foco em custo em aplica\u00e7\u00f5es densas e de curta dist\u00e2ncia.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Para interconex\u00e3o eficiente de 2 km:<\/strong> <strong>LINK-PP<\/strong> fornece confiabilidade e baixo consumo de energia <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472577.htm\"><strong>100G<\/strong> <strong>transceptores CWDM4<\/strong><\/a> otimizado para solu\u00e7\u00f5es escal\u00e1veis de data center e redes empresariais de alta largura de banda.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ambos os m\u00f3dulos passam por testes rigorosos <strong>de transceptores \u00f3pticos<\/strong> para garantir compatibilidade, baixa <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/glossary\/understanding-what-is-bit-error-rate\/\"><strong>taxa de erro de bits (BER)<br><\/strong><\/a>, e longevidade, proporcionando-lhe confian\u00e7a em sua infraestrutura de rede \u00f3ptica.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Conclus\u00e3o: Otimizando sua borda \u00f3ptica<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Understanding the <strong>diferen\u00e7as entre PSM4 e CWDM4<\/strong> \u00e9 fundamental para tomar decis\u00f5es informadas <strong>na sele\u00e7\u00e3o de transceptores 100G<\/strong>. Embora o PSM4 ofere\u00e7a simplicidade para conex\u00f5es paralelas ultra-curtas, <strong>o CWDM4 tornou-se o padr\u00e3o dominante para links 100G de 2 km devido \u00e0 sua efici\u00eancia superior no uso de fibra, gerenciamento mais f\u00e1cil e menores custos gerais de infraestrutura.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pronto para otimizar sua implanta\u00e7\u00e3o 100G com a solu\u00e7\u00e3o \u00f3ptica certa? \ud83d\udd17<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\ud83d\udc49 Explore toda a linha de m\u00f3dulos 100G QSFP28 de alto desempenho e confiabilidade da LINK-PP, incluindo nossos transceptores CWDM4 l\u00edderes de mercado e transceptores PSM4, projetados para entregar valor m\u00e1ximo e tempo de atividade ininterrupto para seus links cr\u00edticos. <\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>Visite nossa p\u00e1gina de produtos \u279e<\/strong><\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Perguntas frequentes (FAQ)<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Qual \u00e9 a principal diferen\u00e7a entre PSM4 e CWDM4?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">O PSM4 necessita de oito fibras e utiliza conectores MPO\/MTP. Ele transmite dados em paralelo. O CWDM4 necessita apenas de duas fibras e utiliza conectores LC duplex. Ele transmite dados usando diferentes comprimentos de onda.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>O PSM4 \u00e9 adequado para links curtos. O CWDM4 \u00e9 melhor para dist\u00e2ncias maiores.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >Qual transceptor \u00e9 mais f\u00e1cil de instalar em redes existentes?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">O CWDM4 geralmente \u00e9 mais f\u00e1cil de instalar. A maioria das redes j\u00e1 utiliza conectores LC e cabos de duas fibras.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>O PSM4 pode exigir nova fibra paralela, caso voc\u00ea n\u00e3o a tenha.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Qual op\u00e7\u00e3o \u00e9 mais econ\u00f4mica para dist\u00e2ncias curtas?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">O PSM4 frequentemente custa menos para links curtos, se voc\u00ea j\u00e1 possui fibra paralela.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>O CWDM4 pode economizar dinheiro em cabos para novas redes ou redes maiores.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >Ambos os transceptores PSM4 e CWDM4 suportam atualiza\u00e7\u00f5es futuras da rede?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">O CWDM4 \u00e9 melhor para atualiza\u00e7\u00f5es. Ele utiliza menos fibras, tornando f\u00e1cil a adi\u00e7\u00e3o de mais.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>O PSM4 pode exigir mais espa\u00e7o \u00e0 medida que sua rede cresce.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Qual transceptor um data center deve escolher para links longos?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Um data center deve escolher o CWDM4 para links de at\u00e9 2 quil\u00f4metros.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>O PSM4 \u00e9 ideal para links curtos dentro de um pr\u00e9dio.<\/p><\/blockquote>","protected":false},"excerpt":{"rendered":"<p>Compare PSM4 vs. CWDM4 para escolher o transceptor \u00f3ptico 100G certo para a sua rede com base em dist\u00e2ncia, cabeamento, custo e necessidades de atualiza\u00e7\u00e3o.<\/p>","protected":false},"author":1,"featured_media":5435,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13],"class_list":["post-5436","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts\/5436","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/comments?post=5436"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts\/5436\/revisions"}],"predecessor-version":[{"id":11253,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts\/5436\/revisions\/11253"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/media\/5435"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/media?parent=5436"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/categories?post=5436"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/tags?post=5436"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}