{"id":5280,"date":"2025-09-01T00:00:00","date_gmt":"2025-09-01T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/optical-transceiver-insertion-loss-definition-impact\/"},"modified":"2026-06-22T07:58:23","modified_gmt":"2026-06-22T07:58:23","slug":"optical-transceiver-insertion-loss-definition-impact","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/pt\/knowledge-center\/optical-transceiver-insertion-loss-definition-impact","title":{"rendered":"Perda de Inser\u00e7\u00e3o do Transceptor \u00d3ptico: Defini\u00e7\u00e3o, Medi\u00e7\u00e3o e Impacto"},"content":{"rendered":"<h2 class=\"wp-block-heading\" >\u25b6 Introdu\u00e7\u00e3o<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Em comunica\u00e7\u00f5es \u00f3pticas, cada fra\u00e7\u00e3o de decibel pode decidir se um enlace opera perfeitamente ou falha sob carga. Um dos par\u00e2metros mais importantes \u00e9 <strong>perda de inser\u00e7\u00e3o (PI)<\/strong> \u2014 a quantidade de pot\u00eancia \u00f3ptica perdida quando a luz atravessa um componente, conector ou enlace de fibra. Os engenheiros consideram a perda de inser\u00e7\u00e3o uma medi\u00e7\u00e3o fundamental ao calcular or\u00e7amentos de enlace, testar instala\u00e7\u00f5es de fibra e selecionar <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">transceptores \u00f3pticos<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Este artigo explica o que \u00e9 perda de inser\u00e7\u00e3o, como ela \u00e9 medida, quais s\u00e3o os valores t\u00edpicos e por que \u00e9 importante para o desempenho de m\u00f3dulos \u00f3pticos, como os fornecidos por <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/page\/aboutus.htm\"><strong>LINK-PP<\/strong><\/a>.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/283194d74a2a4ae4857bfb467fb58fca.webp\" alt=\"Optical transceiver insertion loss visualized across LC and MPO connectors in a data center link\" class=\"wp-image-5276\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/283194d74a2a4ae4857bfb467fb58fca.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/283194d74a2a4ae4857bfb467fb58fca-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/283194d74a2a4ae4857bfb467fb58fca-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/283194d74a2a4ae4857bfb467fb58fca-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/283194d74a2a4ae4857bfb467fb58fca-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 O que \u00e9 \u201cPerda de Inser\u00e7\u00e3o do Transceptor \u00d3ptico\u201d?<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Defini\u00e7\u00e3o em termos simples<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Perda de inser\u00e7\u00e3o \u00e9 a redu\u00e7\u00e3o da pot\u00eancia do sinal entre a entrada e a sa\u00edda de um componente ou enlace. \u00c9 sempre expressa em <strong>decib\u00e9is (dB)<\/strong>. Uma PI menor significa que mais luz atinge o receptor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Matematicamente:<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"320\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/222f8c7683aa4833bd4b9e10f9448198.webp\" alt=\"Optical Transceiver Insertion Loss\" class=\"wp-image-5277\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/222f8c7683aa4833bd4b9e10f9448198.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/222f8c7683aa4833bd4b9e10f9448198-300x80.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/222f8c7683aa4833bd4b9e10f9448198-1024x273.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/222f8c7683aa4833bd4b9e10f9448198-768x205.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/222f8c7683aa4833bd4b9e10f9448198-18x5.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Onde:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Pin<\/strong> = pot\u00eancia \u00f3ptica de entrada<\/p><\/li><li><p><strong>Pout<\/strong> = pot\u00eancia \u00f3ptica de sa\u00edda<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Se voc\u00ea injetar \u20132 dBm em uma fibra e receber \u20132,5 dBm na extremidade distante, a perda de inser\u00e7\u00e3o \u00e9 de 0,5 dB.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >Por que a PI \u00e9 importante<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Como os receptores \u00f3pticos exigem uma pot\u00eancia de entrada m\u00ednima espec\u00edfica para operar corretamente, uma PI excessiva reduz diretamente a margem do sistema e pode fazer com que o receptor fique abaixo do limiar de sensibilidade. Isso leva a maiores <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/glossary\/understanding-what-is-bit-error-rate\/\">taxas de erro de bit (BER)<\/a> ou at\u00e9 mesmo \u00e0 perda de conex\u00f5es.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Causas da Perda de Inser\u00e7\u00e3o<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A perda de inser\u00e7\u00e3o \u00e9 inevit\u00e1vel, mas pode ser minimizada com um bom projeto e manuten\u00e7\u00e3o. Os principais fatores contribuintes incluem:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Perda de acoplamento do conector<\/strong> \u2014 Pequenos espa\u00e7os, desalinhamento ou sujeira entre dois conectores de fibra aumentam a perda.<\/p><\/li><li><p><strong>Atenua\u00e7\u00e3o da fibra<\/strong> \u2014 Mesmo fibras monomodo de alta qualidade apresentam atenua\u00e7\u00e3o inerente (ex.: ~0,35 dB\/km a 1310 nm, ~0,2 dB\/km a 1550 nm).<\/p><\/li><li><p><strong>Perda de emenda<\/strong> \u2014 Emendas mec\u00e2nicas ou por fus\u00e3o normalmente acrescentam 0,05\u20130,3 dB.<\/p><\/li><li><p><strong>Perda por curvatura<\/strong> \u2014 Curvaturas acentuadas ou microcurvaturas causam vazamento do sinal.<\/p><\/li><li><p><strong>Perdas internas nos m\u00f3dulos<\/strong> \u2014 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475859.htm\">Transceptores \u00f3pticos<\/a> possuem lentes e interfaces embutidas que acrescentam pequenos valores de PI.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Como Medir a Perda de Inser\u00e7\u00e3o<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >OLTS (Conjunto de Teste de Perda \u00d3ptica)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A forma mais precisa de medir a perda por inser\u00e7\u00e3o (IL) \u00e9 com um OLTS: uma fonte de luz calibrada em uma extremidade do enlace e um medidor de pot\u00eancia na outra. Este \u00e9 o padr\u00e3o <strong>Teste de certifica\u00e7\u00e3o de n\u00edvel 1<\/strong> em fibras \u00f3pticas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Etapas:<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>Conecte a fonte e o medidor com um cabo de refer\u00eancia conhecido.<\/p><\/li><li><p>Me\u00e7a a pot\u00eancia de refer\u00eancia (Pin).<\/p><\/li><li><p>Conecte o enlace de fibra sob teste.<\/p><\/li><li><p>Me\u00e7a a pot\u00eancia de sa\u00edda (Pout).<\/p><\/li><li><p>Calcule IL = 10\u00b7log10(Pin\/Pout).<\/p><\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" >OTDR (Reflect\u00f4metro de Tempo \u00d3ptico)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Um OTDR tamb\u00e9m pode estimar a IL, mas \u00e9 usado principalmente para localiza\u00e7\u00e3o de falhas. Para testes de aceita\u00e7\u00e3o, prefere-se o OLTS.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Dicas para testes de campo<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Limpe sempre os conectores antes do teste \u2014 a contamina\u00e7\u00e3o \u00e9 a principal causa de perda excessiva.<\/p><\/li><li><p>Realize o teste em ambas as dire\u00e7\u00f5es (A\u2192B e B\u2192A) e calcule a m\u00e9dia dos resultados.<\/p><\/li><li><p>Utilize cabos de refer\u00eancia de alta qualidade com IL conhecida e baixa.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Valores t\u00edpicos de perda por inser\u00e7\u00e3o<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Valores t\u00edpicos de IL ajudam engenheiros a projetar or\u00e7amentos de enlace:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Conector \u00fanico:<\/strong> 0,1\u20130,5 dB (polimento adequado e limpeza).<\/p><\/li><li><p><strong>Emenda mec\u00e2nica:<\/strong> 0,2\u20130,5 dB.<\/p><\/li><li><p><strong>Emenda por fus\u00e3o:<\/strong> 0,05\u20130,1 dB.<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482604.htm\"><strong>Fibra monomodo<\/strong><\/a><strong> atenua\u00e7\u00e3o:<\/strong> 0,35 dB\/km a 1310 nm, 0,2 dB\/km a 1550 nm.<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/488477.htm\"><strong>Fibra multimodo<\/strong><\/a><strong> atenua\u00e7\u00e3o:<\/strong> 3,0 dB\/km a 850 nm, 1,0 dB\/km a 1300 nm.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Por exemplo, um enlace monomodo de 10 km a 1550 nm com dois conectores e duas emendas pode ter IL total \u2248 0,2 \u00d7 10 + 0,3 + 0,1 = 2,4 dB.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Perda por inser\u00e7\u00e3o nos c\u00e1lculos de or\u00e7amento de enlace<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">O or\u00e7amento de enlace \u00e9 a diferen\u00e7a entre a pot\u00eancia de sa\u00edda do transmissor e a sensibilidade do receptor, ajustada pela IL e pela margem.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Exemplo:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Pot\u00eancia do transmissor (Tx): 0 dBm<\/p><\/li><li><p>Sensibilidade do receptor (Rx): \u201314 dBm<\/p><\/li><li><p>Or\u00e7amento dispon\u00edvel = 14 dB<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Se IL = 10 dB, margem = 4 dB \u2192 <strong>aceit\u00e1vel<\/strong>.<br\/>Se IL = 15 dB, margem = \u20131 dB \u2192 <strong>enlace falha<\/strong>.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Isso mostra por que at\u00e9 fra\u00e7\u00f5es de dB s\u00e3o importantes.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Impacto sobre transceptores \u00f3pticos<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A perda por inser\u00e7\u00e3o afeta <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">m\u00f3dulos \u00f3pticos<\/a> de tr\u00eas maneiras principais:<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p><strong>Margem reduzida:<\/strong> Alta IL reduz a margem de sistema dispon\u00edvel, deixando o enlace vulner\u00e1vel ao envelhecimento ou a varia\u00e7\u00f5es de temperatura.<\/p><\/li><li><p><strong>Taxa de erro de bit (BER) mais alta:<\/strong> Rela\u00e7\u00e3o sinal-ru\u00eddo menor no receptor significa mais erros de bit.<\/p><\/li><li><p><strong>Alcance reduzido:<\/strong> Um m\u00f3dulo classificado para 40 km pode alcan\u00e7ar apenas 30 km se a IL exceder os valores assumidos.<\/p><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Por exemplo, LINK-PP\u2019s <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482907.htm\"><strong>LS-CW3110-40I<\/strong><\/a><strong> transceptor \u00f3ptico<\/strong> \u00e9 projetado para transmiss\u00e3o de 40 km a 10 G. Se implantado com IL excessiva (conectores sujos, emendas defeituosas), seu alcance efetivo ser\u00e1 reduzido. Verificar a IL, portanto, faz parte da garantia de desempenho conforme as especifica\u00e7\u00f5es do datasheet.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Como minimizar a perda por inser\u00e7\u00e3o<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Limpar conectores<\/strong> antes de cada uso com panos sem fiapos e \u00e1lcool isoprop\u00edlico.<\/p><\/li><li><p><strong>Inspecione as faces de extremidade<\/strong> com um microsc\u00f3pio de fibra.<\/p><\/li><li><p><strong>Utilize emenda por fus\u00e3o<\/strong> em vez de emenda mec\u00e2nica sempre que poss\u00edvel.<\/p><\/li><li><p><strong>Evite curvaturas acentuadas<\/strong> \u2014 respeite o raio de curvatura da fibra.<\/p><\/li><li><p><strong>Escolha componentes de qualidade<\/strong> \u2014 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">m\u00f3dulos<\/a>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-21644-fiber-optic-cages-connectors.htm\">conectores<\/a>, and <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26454-dac-aoc-aec-cables.htm\">cabos de interconex\u00e3o<\/a> com especifica\u00e7\u00f5es garantidas de IL.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Onde o LINK-PP ajuda<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d9cc5ec3f48c48f3b5b28dfe28abb572.webp\" alt=\"LINK-PP Solutions\" class=\"wp-image-5278\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d9cc5ec3f48c48f3b5b28dfe28abb572.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d9cc5ec3f48c48f3b5b28dfe28abb572-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d9cc5ec3f48c48f3b5b28dfe28abb572-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d9cc5ec3f48c48f3b5b28dfe28abb572-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d9cc5ec3f48c48f3b5b28dfe28abb572-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Se voc\u00ea est\u00e1 projetando ou operando links na faixa de 1 G a 800 G, o LINK-PP fornece m\u00f3dulos e conectividade projetados para compatibilidade, desempenho e qualifica\u00e7\u00e3o simplificada:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Transceptores \u00f3pticos: fam\u00edlias SFP\/SFP+, SFP28, QSFP28, QSFP-DD e OSFP alinhadas com as \u00f3pticas Ethernet IEEE. Consulte nossa vis\u00e3o geral sobre por que as empresas escolhem nossos m\u00f3dulos em <a target=\"_blank\" rel=\"nofollow\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/knowledge-center\/why-choose-link-pp-fiber-optical-modules\/\">Por que escolher os m\u00f3dulos \u00f3pticos de fibra LINK-PP<\/a>.<\/p><\/li><li><p>Conectores e conjuntos: conectividade LC duplex e compat\u00edvel com MPO\/MTP, com op\u00e7\u00f5es de baixa perda para proteger seu or\u00e7amento. Para contexto fundamental sobre conectores, consulte <a target=\"_blank\" rel=\"nofollow\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/knowledge-center\/common-fiber-connector-types-optical-transceivers\/\">Tipos Comuns de Conectores de Fibra \u00d3ptica em Transceptores \u00d3pticos<\/a>.<\/p><\/li><li><p>Avalia\u00e7\u00e3o facilitada: Solicite amostras gratuitas e obtenha suporte de engenharia para validar a perda por inser\u00e7\u00e3o (IL) e os or\u00e7amentos de link no seu ambiente \u2014 consulte as chamadas \u00e0 a\u00e7\u00e3o (CTA) de amostra\/suporte nas nossas p\u00e1ginas da loja, como a <a target=\"_blank\" rel=\"nofollow\" href=\"https:\/\/www.l-p.com\/store-26155-1g-sfp.htm\">p\u00e1gina do cat\u00e1logo LINK-PP SFP 1G<\/a>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Perguntas frequentes r\u00e1pidas<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q1: Qual \u00e9 um valor aceit\u00e1vel de perda por inser\u00e7\u00e3o por conector?<\/strong><br\/>R: Para conectores de alta qualidade, &lt;0,3 dB \u00e9 t\u00edpico.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q2: Com que frequ\u00eancia a perda por inser\u00e7\u00e3o deve ser testada?<\/strong><br\/>R: Na instala\u00e7\u00e3o e ap\u00f3s qualquer manuten\u00e7\u00e3o importante. Em links cr\u00edticos, pode ser retestada durante auditorias programadas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q3: A perda por inser\u00e7\u00e3o pode ser reduzida ap\u00f3s a instala\u00e7\u00e3o?<\/strong><br\/>R: Muitas vezes, sim \u2014 limpar os conectores ou reterminar emendas com alta perda pode reduzir a IL.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Conclus\u00e3o<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A perda por inser\u00e7\u00e3o pode parecer um n\u00famero pequeno, mas em redes \u00f3pticas de alta velocidade cada fra\u00e7\u00e3o de decibel conta. Um projeto adequado, testes corretos e manuten\u00e7\u00e3o s\u00e3o essenciais para garantir desempenho confi\u00e1vel.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para engenheiros que implantam <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>Transceptores \u00f3pticos LINK-PP<\/strong><\/a>, verificar a perda por inser\u00e7\u00e3o \u00e9 uma etapa cr\u00edtica para validar o desempenho no mundo real. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ao compreender a perda por inser\u00e7\u00e3o, test\u00e1-la corretamente e minimiz\u00e1-la na pr\u00e1tica, os operadores de rede podem construir links confi\u00e1veis, de alto desempenho e prontos para o futuro.<\/p>","protected":false},"excerpt":{"rendered":"<p>Saiba o que \u00e9 a perda por inser\u00e7\u00e3o em transceptores \u00f3pticos, como ela afeta o or\u00e7amento de liga\u00e7\u00e3o, a taxa de erro de bit (BER) e a corre\u00e7\u00e3o de erros \u00e0 frente (FEC). Inclui valores para LC\/MPO, dicas de controle e informa\u00e7\u00f5es do LINK-PP.<\/p>","protected":false},"author":1,"featured_media":5279,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[19,21,26],"class_list":["post-5280","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-aoc-dac-cables","tag-fiber-optic-cage-and-connector","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts\/5280","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/comments?post=5280"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts\/5280\/revisions"}],"predecessor-version":[{"id":11203,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts\/5280\/revisions\/11203"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/media\/5279"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/media?parent=5280"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/categories?post=5280"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/tags?post=5280"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}