{"id":5040,"date":"2025-09-16T11:12:00","date_gmt":"2025-09-16T11:12:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/sff-transceiver-vs-1x9-transceiver-comparison-guide\/"},"modified":"2026-06-22T09:05:33","modified_gmt":"2026-06-22T09:05:33","slug":"sff-transceiver-vs-1x9-transceiver-comparison-guide","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/pt\/knowledge-center\/sff-transceiver-vs-1x9-transceiver-comparison-guide","title":{"rendered":"Transceptores SFF vs 1\u00d79: Um guia sobre fibras \u00f3pticas legadas"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1312\" height=\"736\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3577e951f87e44bea06c7d67db2922bf.webp\" alt=\"SFF Transceiver vs 1X9 Transceiver\" class=\"wp-image-5038\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3577e951f87e44bea06c7d67db2922bf.webp 1312w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3577e951f87e44bea06c7d67db2922bf-300x168.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3577e951f87e44bea06c7d67db2922bf-1024x574.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3577e951f87e44bea06c7d67db2922bf-768x431.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3577e951f87e44bea06c7d67db2922bf-18x10.webp 18w\" sizes=\"(max-width: 1312px) 100vw, 1312px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Navegar pelo mundo de <strong>infraestrutura de fibra \u00f3ptica legada<\/strong> pode ser uma tarefa complexa. Entre os v\u00e1rios componentes, dois formatos de transceptores soldados frequentemente causam confus\u00e3o: o <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/knowledge-center\/understanding-what-is-sff-transceiver\/\"><strong>SFF (Fator de Forma Pequeno)<\/strong><\/a> e o <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/knowledge-center\/1x9-transceiver-optical-network-guide\/\"><strong>transceptor 1\u00d79<\/strong><\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Embora as \u00f3pticas <strong>hot-pluggable modernas<\/strong> como SFP e QSFP dominem os data centers atuais, compreender essas tecnologias mais antigas, montadas diretamente na placa-m\u00e3e, \u00e9 crucial para manter e atualizar equipamentos de rede existentes. Este guia distinguir\u00e1 claramente entre os m\u00f3dulos SFF e 1\u00d79, destacando suas principais diferen\u00e7as para ajud\u00e1-lo a tomar decis\u00f5es informadas sobre suas necessidades de rede legada.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 O trabalho cl\u00e1ssico: o transceptor 1\u00d79<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-30686-1x9-optical-transceiver.htm\"><strong>transceptor 1\u00d79<\/strong><\/a> \u00e9 um dos primeiros formatos padronizados de m\u00f3dulo \u00f3ptico. Seu nome deriva de sua interface f\u00edsica: uma \u00fanica fileira de <strong>9 pinos<\/strong> para soldagem direta na placa-m\u00e3e do sistema <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/glossary\/what-is-pcb-printed-circuit-board\/\"><strong>(PCB)<\/strong><\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caracter\u00edsticas principais do 1\u00d79:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Projeto montado na placa:<\/strong> Trata-se de um <strong>m\u00f3dulo soldado<\/strong>, fixado permanentemente \u00e0 placa hospedeira. N\u00e3o \u00e9 plug\u00e1vel nem hot-swappable.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Pegada maior:<\/strong> \u00c9 relativamente volumoso pelos padr\u00f5es atuais, resultando em menor densidade de portas em uma placa de linha.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Funcionalidade simples:<\/strong> Normalmente suporta fun\u00e7\u00f5es essenciais com diagn\u00f3sticos limitados, muitas vezes apenas uma sa\u00edda de Perda de Sinal (LOS).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Aplica\u00e7\u00f5es Principais:<\/strong> Encontrado predominantemente em equipamentos de rede muito antigos, como hubs, switches e roteadores, suportando <strong>Fast Ethernet (100BASE-FX)<\/strong> and <strong>Canal de Fibra 1G\/2G<\/strong>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 O inovador em densidade: o transceptor SFF<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-30687-sff-optical-transceiver.htm\"><strong>transceptor SFF (Small Form-Factor)<\/strong><\/a> foi desenvolvido como sucessor do 1\u00d79 para resolver suas limita\u00e7\u00f5es de tamanho e densidade. \u00c9 fundamental observar que o <strong>SFF tamb\u00e9m \u00e9 um m\u00f3dulo soldado<\/strong>. Foi projetado para ser menor e abrir caminho para recursos mais avan\u00e7ados, levando posteriormente \u00e0 cria\u00e7\u00e3o do padr\u00e3o <em>plug\u00e1vel<\/em> SFP (Small Form-factor Pluggable).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caracter\u00edsticas principais do SFF:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Soldado, mas menor:<\/strong> Assim como o 1\u00d79, o SFF \u00e9 <strong>soldado \u00e0 placa de circuito impresso (PCB)<\/strong>, mas sua pegada f\u00edsica \u00e9 significativamente menor (por exemplo, com <strong>configura\u00e7\u00f5es de pinos 2\u00d75, 2\u00d77 ou 2\u00d710<\/strong>), permitindo maior densidade de portas.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Capacidades avan\u00e7adas:<\/strong> Muitos m\u00f3dulos SFF integraram suporte para <strong>Monitoramento Digital Diagn\u00f3stico <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/glossary\/ddm-dom-in-optical-transceivers\/\"><strong>(DDM ou DOM)<\/strong><\/a> conforme a especifica\u00e7\u00e3o MSA SFF-8472, fornecendo dados em tempo real vitais sobre temperatura, pot\u00eancia \u00f3ptica e corrente de polariza\u00e7\u00e3o do laser.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Aplica\u00e7\u00f5es Principais:<\/strong> Tornou-se o padr\u00e3o para m\u00f3dulos montados na placa em aplica\u00e7\u00f5es de <strong>Gigabit Ethernet (1000BASE-SX\/LX\/ZX)<\/strong> em switches, roteadores e placas de interface de rede (NICs), antes de ser substitu\u00eddo pelo SFP.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Compara\u00e7\u00e3o detalhada entre SFF e 1\u00d79<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1312\" height=\"736\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/928ad0ba2a1348948063d1bf6c9ea491.webp\" alt=\"SFF vs 1x9\" class=\"wp-image-5039\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/928ad0ba2a1348948063d1bf6c9ea491.webp 1312w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/928ad0ba2a1348948063d1bf6c9ea491-300x168.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/928ad0ba2a1348948063d1bf6c9ea491-1024x574.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/928ad0ba2a1348948063d1bf6c9ea491-768x431.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/928ad0ba2a1348948063d1bf6c9ea491-18x10.webp 18w\" sizes=\"(max-width: 1312px) 100vw, 1312px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">A tabela a seguir fornece uma compara\u00e7\u00e3o clara, lado a lado, desses dois formatos legados.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Recurso<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Transceptor SFF<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Transceptor 1\u00d79<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Fator de Forma<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Pequeno Formato (por exemplo, pinos 2\u00d75, 2\u00d77)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u00danica fileira de 9 pinos<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Tipo de conex\u00e3o<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Soldado \u00e0 placa de circuito impresso (PCB)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Soldado \u00e0 placa de circuito impresso (PCB)<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Hot-Pluggable<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u274c N\u00e3o<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u274c N\u00e3o<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Densidade de portas<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2705 <strong>High<\/strong> (Devido ao menor tamanho)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u274c <strong>Baixa<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Taxas de dados t\u00edpicas<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fast Ethernet, <strong>Ethernet Gigabit<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fast Ethernet, Canal de Fibra<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Diagn\u00f3sticos digitais (DDM\/DOM)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2705 Frequentemente suportado<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u274c Raramente suportado<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Relev\u00e2ncia atual<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Encontrado em equipamentos legados mais recentes<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Encontrado em equipamentos legados mais antigos<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Escolhendo o m\u00f3dulo certo para sua aplica\u00e7\u00e3o<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Sua escolha \u00e9 quase inteiramente determinada pelo hardware com o qual voc\u00ea est\u00e1 trabalhando.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Voc\u00ea precisa de um transceptor 1\u00d79 se:<\/strong> Estiver reparando ou mantendo equipamentos legados muito antigos, originalmente projetados com pinos 1\u00d79 soldados na placa-m\u00e3e.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Voc\u00ea precisa de um transceptor SFF se:<\/strong> A placa-m\u00e3e do seu dispositivo tiver \u00e1reas de montagem (footprints) para a configura\u00e7\u00e3o espec\u00edfica de pinos SFF (por exemplo, 2\u00d75 ou 2\u00d77). Por exemplo, um <strong>LINK-PP LF5-MM851G-S5IDS<\/strong> seria uma escolha perfeita e confi\u00e1vel para uma aplica\u00e7\u00e3o multimodo Gigabit exigindo um <strong>m\u00f3dulo soldado de 2\u00d75 pinos<\/strong>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Mantendo sistemas legados com confian\u00e7a<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Compreender a distin\u00e7\u00e3o entre esses formatos soldados \u00e9 essencial para uma manuten\u00e7\u00e3o eficaz de redes. Obter m\u00f3dulos compat\u00edveis e de alta qualidade \u00e9 fundamental para a confiabilidade.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/page\/aboutus.htm\"><strong>LINK-PP<\/strong><\/a> fornece componentes \u00f3pticos compat\u00edveis com a MSA, incluindo formatos legados como <strong>os m\u00f3dulos SFF<\/strong>. Com compromisso com qualidade e desempenho, <strong>LINK-PP<\/strong> garante que sua infraestrutura legada permane\u00e7a operacional e eficiente.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\ud83d\udc49 Precisa de uma fonte confi\u00e1vel de transceptores SFF ou 1\u00d79 legados?<\/strong> <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/page\/contactus.htm\"><strong>Entre em contato com os especialistas da LINK-PP ainda hoje<\/strong><\/a> para verifica\u00e7\u00e3o de compatibilidade e suporte t\u00e9cnico. Deixe-nos ajud\u00e1-lo a manter sua rede funcionando sem interrup\u00e7\u00f5es.<\/p>","protected":false},"excerpt":{"rendered":"<p>This guide clarifies the differences between soldered SFF and 1&#215;9 transceiver form factors. Learn their specs, applications, and how to choose for your network.<\/p>","protected":false},"author":1,"featured_media":5038,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[26],"class_list":["post-5040","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts\/5040","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/comments?post=5040"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts\/5040\/revisions"}],"predecessor-version":[{"id":11373,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts\/5040\/revisions\/11373"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/media\/5038"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/media?parent=5040"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/categories?post=5040"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/tags?post=5040"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}