{"id":4626,"date":"2025-10-23T11:12:00","date_gmt":"2025-10-23T11:12:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/rj45-magjacks-between-plc-and-scada-host\/"},"modified":"2026-06-22T09:00:57","modified_gmt":"2026-06-22T09:00:57","slug":"rj45-magjacks-between-plc-and-scada-host","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/pt\/knowledge-center\/rj45-magjacks-between-plc-and-scada-host","title":{"rendered":"RJ45 Magjack \u2013 Interface de Comunica\u00e7\u00e3o Ethernet entre PLC e Host SCADA"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6155cfaa516e4605ac03cabecce18b61.webp\" alt=\"RJ45 Magjacks Between PLC and SCADA Host\" class=\"wp-image-4622\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6155cfaa516e4605ac03cabecce18b61.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6155cfaa516e4605ac03cabecce18b61-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6155cfaa516e4605ac03cabecce18b61-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6155cfaa516e4605ac03cabecce18b61-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6155cfaa516e4605ac03cabecce18b61-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Na automa\u00e7\u00e3o industrial moderna, a liga\u00e7\u00e3o entre controladores l\u00f3gicos program\u00e1veis (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/glossary\/plc-programmable-logic-controller-for-industrial-automation-guide\/\"><strong>CLPs<\/strong><\/a>) e sistemas de supervis\u00e3o e aquisi\u00e7\u00e3o de dados (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/glossary\/what-is-scada-systems\/\"><strong>SCADA<\/strong><\/a>) depende de uma conectividade Ethernet confi\u00e1vel. No centro dessa conectividade encontra-se o <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-17492-integrated-rj45-connector.htm\"><strong>Magjack RJ45<\/strong><\/a>\u2014 um conector Ethernet que integra magn\u00e9ticos e blindagem para garantir integridade do sinal, imunidade a ru\u00eddos e robustez do sistema. Este artigo analisa o papel fundamental dos conectores Magjack no caminho de comunica\u00e7\u00e3o entre PLC e SCADA, descreve suas caracter\u00edsticas t\u00e9cnicas e explica como contribuem para a confiabilidade da Ethernet industrial.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\ud83d\udd01 Por que a conex\u00e3o entre PLC e host SCADA \u00e9 importante<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Em uma arquitetura t\u00edpica de automa\u00e7\u00e3o, um PLC (ou unidade terminal remota, RTU) coleta dados de dispositivos de campo e os troca com o host SCADA para monitoramento, controle e an\u00e1lise. Por exemplo, sensores transmitem medi\u00e7\u00f5es ao PLC, que envia dados e recebe comandos de controle via Ethernet para o servidor ou esta\u00e7\u00e3o-mestre SCADA. Nessa cadeia, a interface Ethernet deve fornecer:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Transfer\u00eancia de dados de alta velocidade e baixa lat\u00eancia<\/strong> para que os operadores SCADA tenham visibilidade e controle em tempo real.<\/p><\/li>\n\n\n\n<li><p><strong>Integridade f\u00edsica e de sinal robusta<\/strong> em ambientes industriais agressivos (interfer\u00eancia eletromagn\u00e9tica (EMI), potenciais de terra, vibra\u00e7\u00e3o, extremos de temperatura).<\/p><\/li>\n\n\n\n<li><p><strong>Isolamento galv\u00e2nico e prote\u00e7\u00e3o<\/strong> contra sobretens\u00f5es transit\u00f3rias ou <strong>la\u00e7os de terra<\/strong> entre dispositivos distribu\u00eddos.<\/p><\/li>\n\n\n\n<li><p><strong>Layout eficiente de placa<\/strong> para caber em m\u00f3dulos compactos de PLC e cart\u00f5es de rede de controle.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Como essa interface frequentemente utiliza um conector RJ45 montado na placa de circuito impresso (PCB), escolher o <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-17492-integrated-rj45-connector.htm\">conector<\/a> certo torna-se cr\u00edtico para a confiabilidade geral do sistema.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\ud83d\udd01 O que \u00e9 um RJ45 Magjack?<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8ac0179909a048778b276ddac09035ab.jpg\" alt=\"What Is an RJ45 Magjack?\" class=\"wp-image-4623\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8ac0179909a048778b276ddac09035ab.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8ac0179909a048778b276ddac09035ab-300x178.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8ac0179909a048778b276ddac09035ab-1024x608.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8ac0179909a048778b276ddac09035ab-768x456.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8ac0179909a048778b276ddac09035ab-18x12.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">An <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/knowledge-center\/magnetic-rj45-jack-integrated-connector-modules\/\">Magjack RJ45<\/a> \u00e9 um conector modular Ethernet (8P8C) <strong>com magn\u00e9ticos integrados<\/strong> (transformadores de isolamento, filtros de modo comum, \u00e0s vezes LEDs de status e carca\u00e7a blindada) incorporados diretamente no m\u00f3dulo do conector. <br>As principais vantagens incluem:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Condicionamento e isolamento de sinal:<\/strong> Os magn\u00e9ticos embutidos (transformador + filtros) ajudam a suprimir ru\u00eddos, reduzir reflex\u00f5es e diafonia, al\u00e9m de fornecer isolamento galv\u00e2nico (normalmente 1,5 kVrms ou superior) entre o dispositivo e a rede. <\/p><\/li>\n\n\n\n<li><p><strong>Desempenho EMI\/CEM:<\/strong> A carca\u00e7a blindada combinada com magn\u00e9ticos internos oferece maior imunidade em ambientes industriais com alto n\u00edvel de ru\u00eddo el\u00e9trico (motores, inversores, fontes chaveadas). <\/p><\/li>\n\n\n\n<li><p><strong>Efici\u00eancia de espa\u00e7o na placa e projeto simplificado:<\/strong> Como os componentes magn\u00e9ticos discretos j\u00e1 est\u00e3o integrados no Magjack, o layout da PCB torna-se mais simples e compacto \u2014 fator essencial para m\u00f3dulos de PLC e cart\u00f5es de rede compactos. <\/p><\/li>\n\n\n\n<li><p><strong>Versatilidade para Ethernet industrial:<\/strong> Muitos Magjacks suportam Ethernet 10\/100 Base-T e 1 Gigabit, compatibilidade com PoE\/PoE+ e montagem industrial. <\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Assim, ao interligar um PLC a um host SCADA por Ethernet, o Magjack garante que a camada f\u00edsica n\u00e3o se torne um elo fraco.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\ud83d\udd01 Como os Magjacks atendem o caminho PLC \u2194 SCADA<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Interface f\u00edsica no lado do PLC<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No m\u00f3dulo PLC ou no controlador de automa\u00e7\u00e3o embutido, o <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-17492-integrated-rj45-connector.htm\">Conector RJ45 Integrado<\/a> fornece a porta Ethernet que se conecta a switches de rede ou diretamente aos hubs do servidor SCADA. Nesta etapa, o Magjack assegura que o PHY Ethernet do PLC veja uma interface limpa e isolada, imune a diferen\u00e7as de potencial de terra ou impulsos intensos de EMI provenientes do ch\u00e3o de f\u00e1brica.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Conectividade de rede e integridade da transmiss\u00e3o<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Entre o PLC e o host SCADA, cabos Ethernet (Cat5e\/Cat6), <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/knowledge-center\/what-is-a-network-switch\/\">Switches<\/a>, ou switches Ethernet industriais transmitem quadros de dados. Os magn\u00e9ticos e a blindagem embutidos no Magjack ajudam a manter a integridade do sinal nesses cabos e atrav\u00e9s de zonas eletromagneticamente agressivas. Isso reduz perdas de pacotes, minimiza repeti\u00e7\u00f5es e mant\u00e9m est\u00e1vel a comunica\u00e7\u00e3o determin\u00edstica \u2014 essencial para la\u00e7os de controle SCADA.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Lado do host\/SCADA e confiabilidade do sistema completo<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No lado do host SCADA ou da esta\u00e7\u00e3o-mestre, o RJ45 Magjack novamente atua como liga\u00e7\u00e3o f\u00edsica. Qualquer degrada\u00e7\u00e3o na interface (isolamento deficiente, suscetibilidade \u00e0 EMI) pode causar omiss\u00f5es de dados, alarmes incorretos ou atrasos no controle. Ao utilizar Magjacks, os projetistas de sistemas refor\u00e7am a confiabilidade de toda a arquitetura PLC \u2194 SCADA.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Exig\u00eancias da automa\u00e7\u00e3o industrial<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Em ambientes de automa\u00e7\u00e3o industrial (por exemplo, f\u00e1bricas, subesta\u00e7\u00f5es el\u00e9tricas, esta\u00e7\u00f5es de tratamento de \u00e1gua), a interface Ethernet deve resistir a estresse mec\u00e2nico, poeira, vibra\u00e7\u00e3o, alta umidade e mudan\u00e7as frequentes de cabos. M\u00f3dulos Magjack projetados para montagem em furos passantes, reten\u00e7\u00e3o mec\u00e2nica refor\u00e7ada e diagn\u00f3sticos baseados em LEDs ajudam a atender essas exig\u00eancias. <\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\ud83d\udd01 Crit\u00e9rios-chave de sele\u00e7\u00e3o de RJ45 Magjacks em sistemas PLC\/SCADA<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ao especificar um Magjack para uma liga\u00e7\u00e3o PLC-a-SCADA, considere os seguintes atributos:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Velocidade e padr\u00e3o Ethernet<\/strong>: Certifique-se de que haja suporte \u00e0s taxas de dados exigidas (10\/100 Mb\/s ou 5 Gb\/s) e \u00e0 funcionalidade auto-MDIX. <\/p><\/li>\n\n\n\n<li><p><strong>Magn\u00e9ticos integrados<\/strong>: Transformadores e filtros devem estar embutidos e classificados para <a href=\"https:\/\/resourceslp.szlogic.cn\/pt\/knowledge-center\/lan-transformer-isolation-voltage-explained\/\" target=\"_blank\" rel=\"\">isolamento<\/a> confi\u00e1veis e de alto desempenho, <strong>1500 Vrms<\/strong>), minimizando componentes externos. <\/p><\/li>\n\n\n\n<li><p><strong>Classifica\u00e7\u00e3o EMI\/CEM e carca\u00e7a blindada<\/strong>: Para ambientes industriais, busque certifica\u00e7\u00f5es ou ensaios como IEC61000-4-2\/\u22124-3, etc.<\/p><\/li>\n\n\n\n<li><p><strong>Montagem mec\u00e2nica<\/strong>: As vers\u00f5es com montagem por fura\u00e7\u00e3o oferecem melhor resist\u00eancia \u00e0 vibra\u00e7\u00e3o\/resili\u00eancia do que as montadas em superf\u00edcie para placas de CLP em ambientes agressivos. <\/p><\/li>\n\n\n\n<li><p><strong>Compatibilidade PoE\/PoE+<\/strong>: Se o CLP ou n\u00f3 de borda exigir alimenta\u00e7\u00e3o via Ethernet, certifique-se de que o Magjack suporte <a href=\"https:\/\/resourceslp.szlogic.cn\/pt\/knowledge-center\/ieee-802-3af-vs-ieee-802-3at-vs-ieee-802-3bt\/\" target=\"_blank\" rel=\"\">IEEE 802.3af\/at\/bt<\/a>.<\/p><\/li>\n\n\n\n<li><p><strong>Diagn\u00f3sticos (LEDs)<\/strong>: Conex\u00e3o\/atividade <a href=\"https:\/\/resourceslp.szlogic.cn\/pt\/knowledge-center\/rj45-connector-with-led-functions\/\" target=\"_blank\" rel=\"\">LEDs<\/a> fornecem diagn\u00f3sticos r\u00e1pidos no campo\u2014valiosos para a manuten\u00e7\u00e3o de redes SCADA.<\/p><\/li>\n\n\n\n<li><p><strong>Ecossistema e ciclo de vida do fornecedor<\/strong>: Para automa\u00e7\u00e3o industrial, escolha conectores de fornecedores confi\u00e1veis <a href=\"https:\/\/www.l-p.com\/\" target=\"_blank\" rel=\"\">fornecedores<\/a> com suporte prolongado ao ciclo de vida do produto.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\ud83d\udd01 Dicas para integra\u00e7\u00e3o em interfaces Ethernet PLC\u2013SCADA<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Segmenta\u00e7\u00e3o do tr\u00e1fego de rede Ethernet<\/strong>: Para links SCADA, mantenha o tr\u00e1fego de controle separado do tr\u00e1fego administrativo; utilize VLANs ou switches fisicamente separados para reduzir lat\u00eancia e evitar interfer\u00eancias.<\/p><\/li>\n\n\n\n<li><p><strong>Roteamento de cabos e aterramento<\/strong>: Evite instalar cabos Ethernet paralelamente a linhas de alta tens\u00e3o ou alta corrente. Utilize cabos blindados e a liga\u00e7\u00e3o \u00e0 terra do chassi para minimizar la\u00e7os de terra.<\/p><\/li>\n\n\n\n<li><p><strong>Utilize <\/strong><a href=\"https:\/\/www.l-p.com\/products\/491473.htm\" target=\"_blank\" rel=\"\"><strong>Magjacks classificados para uso industrial<\/strong><\/a>: Selecione conectores Magjack projetados para grau industrial (temperatura, vibra\u00e7\u00e3o, reten\u00e7\u00e3o na placa) para evitar falhas em ambientes agressivos.<\/p><\/li>\n\n\n\n<li><p><strong>Diagn\u00f3sticos e monitoramento regulares<\/strong>: Utilize LEDs de conex\u00e3o\/atividade e monitoramento de rede para detectar degrada\u00e7\u00e3o da camada f\u00edsica (aumento de repeti\u00e7\u00f5es de pacotes, interrup\u00e7\u00f5es de conex\u00e3o) antes que impactem o desempenho SCADA.<\/p><\/li>\n\n\n\n<li><p><strong>Redund\u00e2ncia e projeto fail-safe<\/strong>: Em links cr\u00edticos PLC\u2194SCADA, considere caminhos de rede redundantes ou portas duplas Magjack para garantir continuidade em caso de falha do conector ou do cabo.<\/p><\/li>\n\n\n\n<li><p><strong>Manuten\u00e7\u00e3o proativa<\/strong>: Substitua conectores envelhecidos, inspecione as termina\u00e7\u00f5es dos cabos e verifique sinais de corros\u00e3o ou folga mec\u00e2nica\u2014essa aten\u00e7\u00e3o \u00e0 camada f\u00edsica melhora a confiabilidade geral do sistema SCADA.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\ud83d\udd01 Como o LINK-PP suporta interfaces Ethernet confi\u00e1veis entre PLC e SCADA<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"608\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8d83e1e985fc4ac19662aa3c55ffb111-1024x608.webp\" alt=\"LPJG0926HENL PoE+ RJ45 Connector\" class=\"wp-image-4624\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8d83e1e985fc4ac19662aa3c55ffb111-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8d83e1e985fc4ac19662aa3c55ffb111-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8d83e1e985fc4ac19662aa3c55ffb111-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8d83e1e985fc4ac19662aa3c55ffb111-18x12.webp 18w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8d83e1e985fc4ac19662aa3c55ffb111.webp 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Na LINK-PP, oferecemos um amplo portf\u00f3lio de <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-17492-integrated-rj45-connector.htm\">Magjacks RJ45 <\/a>de alto desempenho personalizados para automa\u00e7\u00e3o industrial, incluindo modelos com magn\u00e9ticos integrados, suporte a PoE\/PoE+, forte reten\u00e7\u00e3o mec\u00e2nica e classifica\u00e7\u00e3o de temperatura industrial. Por exemplo, o <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/439792.htm\">LPJG0926HENL<\/a> \u00e9 especificamente destacado por sua adequa\u00e7\u00e3o a aplica\u00e7\u00f5es de automa\u00e7\u00e3o industrial e gateways IoT. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ao selecionar o Magjack certo da LINK-PP, os projetistas de sistemas podem garantir que seu caminho de comunica\u00e7\u00e3o PLC para SCADA permane\u00e7a robusto, resistente a interfer\u00eancias e preparado para o futuro\u2014suportando os longos ciclos de vida t\u00edpicos em sistemas de automa\u00e7\u00e3o.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\ud83d\udd01 Conclus\u00e3o<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Em resumo, embora o software e os protocolos de comunica\u00e7\u00e3o PLC \u2194 SCADA recebam muita aten\u00e7\u00e3o, a interface f\u00edsica \u00e9 igualmente cr\u00edtica. O <strong>Magjack RJ45<\/strong> desempenha um papel fundamental ao fornecer uma interface Ethernet que garante integridade do sinal, isolamento e resili\u00eancia em ambientes industriais desafiadores. Quando adequadamente selecionado e integrado, os Magjacks contribuem diretamente para a confiabilidade, tempo de atividade e desempenho dos sistemas SCADA e redes de automa\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para projetistas e engenheiros atuando em automa\u00e7\u00e3o industrial, especificar o Magjack certo n\u00e3o \u00e9 apenas uma escolha de componente\u2014\u00e9 uma decis\u00e3o estrat\u00e9gica que impacta o sucesso operacional a longo prazo. Com <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-17492-integrated-rj45-connector.htm\">Magjacks industriais da LINK-PP<\/a>, voc\u00ea pode construir links Ethernet PLC-to-SCADA mais inteligentes, mais conectados e mais confi\u00e1veis. <strong>links Ethernet PLC-to-SCADA<\/strong>.<\/p>","protected":false},"excerpt":{"rendered":"<p>Explore como os conectores RJ45 Magjack permitem uma comunica\u00e7\u00e3o Ethernet robusta entre CLPs e hosts SCADA na automa\u00e7\u00e3o industrial, garantindo a integridade do sinal e a confiabilidade do sistema.<\/p>","protected":false},"author":1,"featured_media":4625,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[22],"class_list":["post-4626","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-integrated-rj45-connectors"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts\/4626","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/comments?post=4626"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts\/4626\/revisions"}],"predecessor-version":[{"id":11347,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts\/4626\/revisions\/11347"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/media\/4625"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/media?parent=4626"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/categories?post=4626"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/tags?post=4626"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}