{"id":3193,"date":"2026-02-26T00:00:00","date_gmt":"2026-02-26T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/products\/sr-sfp-module-specs-compatibility-distance-selection\/"},"modified":"2026-06-22T04:11:38","modified_gmt":"2026-06-22T04:11:38","slug":"sr-sfp-module-specs-compatibility-distance-selection","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/pt\/products\/sr-sfp-module-specs-compatibility-distance-selection","title":{"rendered":"M\u00f3dulo SFP SR: Especifica\u00e7\u00f5es, Compatibilidade e Guia de Sele\u00e7\u00e3o"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"628\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cffe377dcfc24b7aae63cc864eb7f7ef.jpg\" alt=\"Especifica\u00e7\u00f5es, compatibilidade e guia de sele\u00e7\u00e3o do m\u00f3dulo SR SFP\" class=\"wp-image-3181\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cffe377dcfc24b7aae63cc864eb7f7ef.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cffe377dcfc24b7aae63cc864eb7f7ef-300x157.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cffe377dcfc24b7aae63cc864eb7f7ef-1024x536.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cffe377dcfc24b7aae63cc864eb7f7ef-768x402.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cffe377dcfc24b7aae63cc864eb7f7ef-18x9.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">An <strong>SR (curto alcance) <\/strong><a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-26155-1g-sfp.htm\"><strong>SFP<\/strong><\/a><strong>\/<\/strong><a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-26192-10g-sfp.htm\"><strong>SFP+<\/strong><\/a><strong> m\u00f3dulo<\/strong> \u00e9 um transceptor \u00f3tico multimodo concebido para liga\u00e7\u00f5es Ethernet de curta dist\u00e2ncia, que funciona normalmente a <strong>850 nm em MMF<\/strong>. \u00c9 amplamente utilizado em redes empresariais e centros de dados para proporcionar uma conectividade econ\u00f3mica e de alta velocidade entre switches, servidores e pain\u00e9is de liga\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Em ambientes modernos de alta densidade, a \u00f3tica SR continua a ser a escolha padr\u00e3o para liga\u00e7\u00f5es no interior de racks, filas e camadas de agrega\u00e7\u00e3o, onde as dist\u00e2ncias se situam geralmente entre dezenas e centenas de metros. Em compara\u00e7\u00e3o com as alternativas monomodo, os m\u00f3dulos SR oferecem um custo \u00f3tico mais baixo e uma infraestrutura de fibra mais simples (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/centro-de-conhecimento\/om1-om2-om3-om4-om5-multimode-fiber-guide\/\">OM3\/OM4<\/a>), e uma elevada densidade de portas \u2014 o que as torna uma base pr\u00e1tica para o acesso 10G e para as arquiteturas \u00ableaf-spine\u00bb.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Este guia explica o <strong>principais especifica\u00e7\u00f5es t\u00e9cnicas<\/strong>, <strong>conformidade com padr\u00f5es<\/strong>, and <strong>considera\u00e7\u00f5es sobre compatibilidade na pr\u00e1tica<\/strong> para m\u00f3dulos SR SFP\/SFP+ e apresenta uma metodologia de sele\u00e7\u00e3o estruturada para ajudar engenheiros, respons\u00e1veis pelas compras e projetistas de redes a escolherem o m\u00f3dulo \u00f3tico adequado para a sua implementa\u00e7\u00e3o.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u23e9 O que \u00e9 um m\u00f3dulo SR SFP?<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">An <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/475415.htm\"><strong>SFP SR<\/strong><\/a><strong> M\u00f3dulo (Pluggable de pequeno formato e curto alcance)<\/strong> \u00e9 um transceptor \u00f3tico concebido para a transmiss\u00e3o Ethernet de curta dist\u00e2ncia atrav\u00e9s de fibra multimodo, funcionando normalmente a <strong>850 nm utilizando um <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/glossary\/overview-of-vcsel\/\"><strong>laser VCSEL<\/strong><\/a>, sendo amplamente utilizada em liga\u00e7\u00f5es empresariais e de centros de dados para proporcionar uma conectividade de alta velocidade e econ\u00f3mica.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2a2ea6dbfd9a403bbab74df7f3812cdb.jpg\" alt=\"O que \u00e9 um m\u00f3dulo SR SFP?\" class=\"wp-image-3182\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2a2ea6dbfd9a403bbab74df7f3812cdb.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2a2ea6dbfd9a403bbab74df7f3812cdb-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2a2ea6dbfd9a403bbab74df7f3812cdb-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2a2ea6dbfd9a403bbab74df7f3812cdb-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2a2ea6dbfd9a403bbab74df7f3812cdb-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Principais caracter\u00edsticas do m\u00f3dulo SR SFP<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u25cf Funcionamento com fibra multimodo<\/strong><br\/>Os m\u00f3dulos SR SFP foram concebidos para <strong>Fibra multimodo (OM2\/OM3\/OM4)<\/strong> infraestrutura, permitindo um cabeamento simplificado dentro de racks, filas e salas de equipamento onde a fibra multimodo j\u00e1 est\u00e1 padronizada.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u25cf Dist\u00e2ncia de transmiss\u00e3o de curto alcance<\/strong><br\/>O alcance t\u00edpico depende da norma Ethernet e do tipo de fibra \u2014 por exemplo, <strong>at\u00e9 cerca de 300 m em OM3<\/strong> and <strong>at\u00e9 cerca de 400\u2013550 m na OM4<\/strong> para variantes SR comuns, como o 10GBASE-SR \u2014 tornando-as ideais para a conectividade dentro do centro de dados.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u25cf Tecnologia \u00f3tica VCSEL de 850 nm<\/strong><br\/>A maioria dos m\u00f3dulos SR utiliza <strong>Laser Emissor de Superf\u00edcie de Cavidade Vertical (VCSEL)<\/strong> fontes a 850 nm, que proporcionam um desempenho est\u00e1vel, um custo de fabrico mais baixo e um acoplamento eficiente \u00e0 fibra multimodo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u25cf Baixo consumo de energia<\/strong><br\/>Em compara\u00e7\u00e3o com os componentes \u00f3ticos monomodo de longo alcance, os m\u00f3dulos SFP SR funcionam normalmente com <strong>menor pot\u00eancia de sa\u00edda \u00f3tica e menor consumo el\u00e9trico<\/strong>, permitindo a implementa\u00e7\u00e3o de comutadores de alta densidade.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u25cf Rela\u00e7\u00e3o custo-efic\u00e1cia para implementa\u00e7\u00f5es em grande escala<\/strong><br\/>Uma vez que a infraestrutura multimodo e os componentes VCSEL s\u00e3o econ\u00f3micos em grande escala, os m\u00f3dulos SFP SR s\u00e3o amplamente utilizados para <strong>ambientes empresariais de grande escala e centros de dados de hiperescala<\/strong> onde s\u00e3o necess\u00e1rios muitos links curtos.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u23e9 Especifica\u00e7\u00f5es t\u00e9cnicas do SR SFP <\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7d33aa5aed65488ba57b38a6ac0fb0a8.jpg\" alt=\"Especifica\u00e7\u00f5es t\u00e9cnicas do m\u00f3dulo SR SFP \" class=\"wp-image-3183\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7d33aa5aed65488ba57b38a6ac0fb0a8.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7d33aa5aed65488ba57b38a6ac0fb0a8-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7d33aa5aed65488ba57b38a6ac0fb0a8-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7d33aa5aed65488ba57b38a6ac0fb0a8-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7d33aa5aed65488ba57b38a6ac0fb0a8-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Par\u00e2metros \u00f3ticos essenciais dos m\u00f3dulos SR<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">SFP de curto alcance (SR)\/<a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/491566.htm\">projetados para confiabilidade e integra\u00e7\u00e3o perfeita. Nossos m\u00f3dulos passam por testes rigorosos para garantir compatibilidade com equipamentos de rede de grande porte e conformidade com os padr\u00f5es IEEE.<\/a> foram concebidos para a transmiss\u00e3o a alta velocidade atrav\u00e9s de fibra multimodo, utilizando uma fonte de luz VCSEL de 850 nm. As implementa\u00e7\u00f5es t\u00edpicas utilizam fibra multimodo (MMF) OM2, OM3 ou OM4, sendo que as dist\u00e2ncias alcan\u00e7\u00e1veis variam consoante o tipo de fibra e a taxa de dados.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Comprimento de onda:<\/strong> Aproximadamente <strong>850 nm<\/strong>, normalmente gerado por um laser VCSEL.<\/p><\/li><li><p><strong>Tipo de fibra:<\/strong> Fibra multimodo (OM2 \/ OM3 \/ OM4) habitualmente utilizada em <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/centro-de-conhecimento\/data-center-interconnect-definition-benefits-and-role-of-optical-modules\/\">interliga\u00e7\u00f5es entre centros de dados<\/a>.<\/p><\/li><li><p><strong>Alcance T\u00edpico:<\/strong><\/p><ul><li><p>At\u00e9 <strong>300 m<\/strong> em vez de OM3\/OM4 para implementa\u00e7\u00f5es 10GBASE-SR.<\/p><\/li><li><p>At\u00e9 <strong>~550 m<\/strong> O alcance m\u00e1ximo \u00e9 frequentemente referido no contexto de implementa\u00e7\u00f5es multimodo SR de baixa velocidade (por exemplo, da classe Gigabit SX).<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Estas varia\u00e7\u00f5es de dist\u00e2ncia dependem da largura de banda modal, da perda no conector e da conce\u00e7\u00e3o do or\u00e7amento de liga\u00e7\u00e3o.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Conformidade com as normas dos m\u00f3dulos \u00f3ticos de curto alcance<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Os m\u00f3dulos SR SFP cumprem, normalmente, as normas de Ethernet e de gest\u00e3o amplamente adotadas:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/centro-de-conhecimento\/ieee-802-3-ethernet-standard-explained\/\"><strong>IEEE 802.3<\/strong><\/a><strong> Fam\u00edlias Ethernet<\/strong><\/p><ul><li><p><strong>1000BASE-SX<\/strong> para liga\u00e7\u00f5es multimodo Gigabit<\/p><\/li><li><p><strong>10GBASE-SR<\/strong> para liga\u00e7\u00f5es de curto alcance de 10 Gigabit em centros de dados<\/p><\/li><\/ul><\/li><li><p><strong>SFF-8472 Monitoriza\u00e7\u00e3o de Diagn\u00f3stico Digital (DOM)<\/strong><\/p><ul><li><p>Permite a monitoriza\u00e7\u00e3o em tempo real da pot\u00eancia \u00f3tica de transmiss\u00e3o\/recep\u00e7\u00e3o, da temperatura, da tens\u00e3o e da polariza\u00e7\u00e3o do laser, para fins de manuten\u00e7\u00e3o preditiva e valida\u00e7\u00e3o da liga\u00e7\u00e3o.<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">A maioria dos m\u00f3dulos SR dispon\u00edveis no mercado tamb\u00e9m est\u00e1 em conformidade com a norma MSA, o que garante a interoperabilidade entre diferentes fabricantes de comutadores e placas de rede.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Tabela de especifica\u00e7\u00f5es do m\u00f3dulo SR SFP<\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Padr\u00e3o<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Comprimento de onda<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Tipo de fibra<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Alcance t\u00edpico<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Conector<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Consumo T\u00edpico de Energia<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/477562.htm\">1000BASE-SX<\/a> (SFP)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~850 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>OM2 \/ OM3 MMF<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>At\u00e9 cerca de 550 m (dependendo da fibra)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>LC Duplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~0,5 W (dispositivos t\u00edpicos desta classe)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/476059.htm\">10GBASE-SR<\/a> (SFP+)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~850 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibra multimodo OM3 \/ OM4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~300 m (OM3), at\u00e9 ~400 m (OM4 em liga\u00e7\u00f5es otimizadas)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>LC Duplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Conce\u00e7\u00e3o de baixo consumo energ\u00e9tico, normalmente na classe inferior a 1 W<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u23e9 Variantes comuns de m\u00f3dulos SFP SR dispon\u00edveis no mercado<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Para evitar que esta p\u00e1gina se torne meramente enciclop\u00e9dica e para melhor servir os engenheiros e as equipas de aquisi\u00e7\u00f5es, esta sec\u00e7\u00e3o apresenta os mais comuns <strong>Variantes SFP\/SFP+ de curto alcance (SR)<\/strong>, a sua autonomia t\u00edpica e os casos de utiliza\u00e7\u00e3o, bem como a forma como se comparam com as alternativas de \u201clongo alcance\u201d.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd975909c654628b9c6ed9f7f64ddb2.jpg\" alt=\"Variantes comuns de m\u00f3dulos SFP SR: SFP 1000BASE-SX, SFP+ 10GBASE-SR, LR, DAC, AOC\" class=\"wp-image-3184\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd975909c654628b9c6ed9f7f64ddb2.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd975909c654628b9c6ed9f7f64ddb2-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd975909c654628b9c6ed9f7f64ddb2-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd975909c654628b9c6ed9f7f64ddb2-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd975909c654628b9c6ed9f7f64ddb2-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >1. SFP 1000BASE-SX<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Alcance t\u00edpico<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Dependendo do tipo de fibra multimodo, <strong>1000BASE-SX<\/strong> pode suportar at\u00e9 aproximadamente:<\/p><ul><li><p>~220 m na fibra OM1\/OM2 mais antiga<\/p><\/li><li><p>~550 m em fibra OM3\/OM4 em condi\u00e7\u00f5es ideais<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Uso T\u00edpico<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Liga\u00e7\u00f5es Gigabit Ethernet de curta dist\u00e2ncia dentro da mesma sala de equipamentos<\/p><\/li><li><p>Liga\u00e7\u00f5es de liga\u00e7\u00e3o ascendente dos servidores, interconex\u00f5es entre switches e liga\u00e7\u00f5es da camada de acesso nas redes empresariais<\/p><\/li><li><p>Uma op\u00e7\u00e3o econ\u00f3mica nos casos em que a largura de banda de 1G continua a ser suficiente e j\u00e1 existe uma infraestrutura multimodo<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Notas sobre a aquisi\u00e7\u00e3o e a implementa\u00e7\u00e3o<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Os componentes \u00f3ticos SX s\u00e3o, normalmente, mais econ\u00f3micos do que os seus equivalentes de 10G<\/p><\/li><li><p>Certifique-se de que a qualidade da fibra suporta o alcance pretendido antes da compra<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >2. 10GBASE-SR SFP+<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Alcance t\u00edpico<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Projetada para <strong>Ethernet de 10 Gigabit<\/strong> atrav\u00e9s de fibra multimodo<\/p><\/li><li><p>Alcance aproximado:<\/p><ul><li><p><strong>~300 m<\/strong> atrav\u00e9s de OM3<\/p><\/li><li><p><strong>~400 m (ou mais)<\/strong> atrav\u00e9s de fibra multimodo OM4<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Uso T\u00edpico<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Centro de dados <strong>Topo do Rack (ToR)<\/strong> uplinks de switch<\/p><\/li><li><p>Tecidos de interconex\u00e3o com espinhas em forma de folha<\/p><\/li><li><p>Liga\u00e7\u00f5es \u00f3ticas curtas dentro de uma linha ou de um m\u00f3dulo, em que \u00e9 necess\u00e1ria conectividade de alta velocidade, mas a dist\u00e2ncia \u00e9 limitada<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Por que \u00e9 amplamente adotado<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Equilibra o desempenho, o custo e a facilidade de implementa\u00e7\u00e3o<\/p><\/li><li><p>Baixo consumo de energia em compara\u00e7\u00e3o com as \u00f3pticas de maior alcance<\/p><\/li><li><p>Funciona bem com DOM\/DDM para monitoriza\u00e7\u00e3o ativa e manuten\u00e7\u00e3o<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >3. Compara\u00e7\u00e3o r\u00e1pida entre SR e LR<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Esta compara\u00e7\u00e3o ajuda a adequar a escolha do m\u00f3dulo \u00e0s necessidades de implementa\u00e7\u00e3o e ao or\u00e7amento:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Recurso<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>SR (alcance curto)<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>LR (Longo Alcance)<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Meio<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibra Multimodo (MMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibra monomodo (SMF)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Alcance t\u00edpico<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~300\u2013400 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>At\u00e9 ~10 km<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Comprimento de onda<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~850 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~1310 nm<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Perfil de custo<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Custo mais baixo, menor consumo de energia<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Custo mais elevado, pot\u00eancia mais elevada<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Casos de uso t\u00edpicos<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Liga\u00e7\u00f5es dentro do rack \/ liga\u00e7\u00f5es curtas no centro de dados<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Campus \/ backbone de edif\u00edcios<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/centro-de-conhecimento\/smf-optical-transceiver-vs-mmf-optical-transceiver-guide\/\"><strong>Fibra multimodo (MMF) vs. fibra monomodo (SMF)<\/strong><\/a><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>MMF (Multimodo)<\/strong> est\u00e1 otimizado para dist\u00e2ncias curtas e tipos de fibra com maior abertura num\u00e9rica (OM2\/OM3\/OM4), proporcionando <strong>efici\u00eancia em termos de custos<\/strong> para liga\u00e7\u00f5es de curto alcance.<\/p><\/li><li><p><strong>SMF (modo \u00fanico)<\/strong> permite percorrer dist\u00e2ncias maiores com um n\u00facleo mais pequeno e <strong>maior or\u00e7amento \u00f3tico<\/strong>, o que implica um aumento do custo do transceptor.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Dist\u00e2ncia<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Os m\u00f3dulos SR foram concebidos especificamente para dist\u00e2ncias curtas no interior de salas de dados ou em clusters de campus.<\/p><\/li><li><p>Os m\u00f3dulos LR foram concebidos para dist\u00e2ncias que excedem os limites da fibra \u00f3tica monomodo (MMF), tais como liga\u00e7\u00f5es entre edif\u00edcios.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Perfil de custo<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/477562.htm\">\u00d3pticas SR<\/a> e os cabos multimodo s\u00e3o, em geral, <strong>mais econ\u00f3mico<\/strong> em vez de \u00f3ticas de comprimento de onda longo e fibra monomodo, quando os requisitos de dist\u00e2ncia o permitirem.<\/p><\/li><li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/476750.htm\">\u00d3pticas LR<\/a> normalmente consomem mais energia e t\u00eam um or\u00e7amento \u00f3tico mais elevado, o que aumenta tanto os custos dos componentes como os custos operacionais.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >4. SR SFP vs. outras op\u00e7\u00f5es de curto alcance<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" >\u2605 SR vs. DAC<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Ao comparar <strong>M\u00f3dulos SFP SR<\/strong> to <strong>DAC (Conex\u00e3o Direta em Cobre)<\/strong> cabos, a principal diferen\u00e7a reside no meio utilizado e no ambiente de implementa\u00e7\u00e3o. Os m\u00f3dulos SR SFP, que utilizam <strong>fibra multimodo<\/strong>, s\u00e3o ideais para ambientes onde existem dist\u00e2ncias mais longas (at\u00e9 300-400 metros) e onde est\u00e1 dispon\u00edvel infraestrutura de fibra \u00f3tica. Por outro lado, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/centro-de-conhecimento\/direct-attach-cables-dac-in-networking\/\">Cabos DAC<\/a>, normalmente <strong>\u00e0 base de cobre<\/strong>, s\u00e3o ideais para liga\u00e7\u00f5es de curta dist\u00e2ncia e econ\u00f3micas, frequentemente em racks de alta densidade, onde o comprimento do cabo \u00e9 normalmente inferior a 10 metros. Os m\u00f3dulos DAC s\u00e3o tamb\u00e9m, em geral, mais econ\u00f3micos do que os m\u00f3dulos SR SFP, mas estes \u00faltimos proporcionam maior flexibilidade, escalabilidade e melhor desempenho global quando s\u00e3o necess\u00e1rias dist\u00e2ncias maiores ou infraestruturas de fibra \u00f3tica.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Principais diferen\u00e7as:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Dist\u00e2ncia:<\/strong> O SR SFP suporta dist\u00e2ncias at\u00e9 300-400 metros, enquanto o DAC abrange normalmente at\u00e9 10 metros.<\/p><\/li><li><p><strong>Custo:<\/strong> O DAC \u00e9, em geral, mais barato devido \u00e0 sua constru\u00e7\u00e3o em cobre.<\/p><\/li><li><p><strong>Consumo de energia:<br><\/strong> Os cabos DAC apresentam um consumo de energia inferior ao dos m\u00f3dulos SR SFP, o que os torna mais adequados para liga\u00e7\u00f5es muito curtas.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caso de Uso:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>SR SFP:<\/strong> Recomendado para instala\u00e7\u00f5es de fibra \u00f3tica que exijam um alcance maior dentro de centros de dados ou campus.<\/p><\/li><li><p><strong>DAC:<\/strong> Ideal para aplica\u00e7\u00f5es de alta densidade e curta dist\u00e2ncia, entre racks ou dentro do mesmo arm\u00e1rio.<\/p><\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\" >\u2605 SR vs. AOC<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/centro-de-conhecimento\/aoc-explained-active-optical-cable-benefits-uses-advancements-guide\/\"><strong>Cabos \u00d3pticos Ativos<\/strong><\/a><strong> (AOC)<\/strong> constituem uma alternativa aos m\u00f3dulos SR SFP, especialmente quando <strong>desempenho da fibra \u00f3tica<\/strong> and <strong>flexibilidade do cabeamento<\/strong> s\u00e3o necess\u00e1rios. Ao contr\u00e1rio dos SFPs SR, que s\u00e3o m\u00f3dulos transceptores separados que requerem cabos de fibra externos, os AOCs integram tanto o transceptor como os cabos de fibra numa \u00fanica unidade flex\u00edvel. Isto torna os AOCs mais f\u00e1ceis de gerir, reduzindo a complexidade da gest\u00e3o de cabos em implementa\u00e7\u00f5es em grande escala. Os AOCs tamb\u00e9m conseguem atingir dist\u00e2ncias maiores em compara\u00e7\u00e3o com os DACs, variando normalmente entre 10 metros e v\u00e1rias centenas de metros, \u00e0 semelhan\u00e7a dos SFPs SR.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Principais diferen\u00e7as:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Dist\u00e2ncia:<\/strong> Os AOC podem suportar dist\u00e2ncias at\u00e9 v\u00e1rias centenas de metros, \u00e0 semelhan\u00e7a dos SFP SR, e normalmente s\u00e3o mais longos do que os cabos DAC.<\/p><\/li><li><p><strong>Custo:<\/strong> Os AOCs s\u00e3o normalmente mais caros do que os DAC, mas podem oferecer uma solu\u00e7\u00e3o de implementa\u00e7\u00e3o mais simples e flex\u00edvel, especialmente para aplica\u00e7\u00f5es de alta velocidade.<\/p><\/li><li><p><strong>Consumo de energia:<br><\/strong> Os cabos AOC podem consumir um pouco mais de energia do que os cabos DAC, mas, normalmente, menos do que os m\u00f3dulos SR SFP e os cabos de fibra \u00f3tica separados.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caso de Uso:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>SR SFP:<\/strong> Ideal para implementa\u00e7\u00f5es de fibra \u00f3tica que exigem escalabilidade e flexibilidade robustas e a longo prazo em centros de dados ou redes de campus.<\/p><\/li><li><p><strong>AOC:<\/strong> Ideal para aplica\u00e7\u00f5es de alta velocidade e elevada largura de banda em ambientes onde a redu\u00e7\u00e3o da confus\u00e3o de cabos e a facilidade de gest\u00e3o s\u00e3o prioridades fundamentais.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u23e9 Requisitos de fibra e cablagem para m\u00f3dulos SR SFP<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">O desempenho fi\u00e1vel dos m\u00f3dulos \u00f3ticos SFP\/SFP+ SR (Short-Reach) depende em grande medida da sele\u00e7\u00e3o do tipo correto de fibra multimodo, do tipo de conector e da manuten\u00e7\u00e3o de uma margem \u00f3tica adequada. Esta sec\u00e7\u00e3o resume os requisitos pr\u00e1ticos de cablagem que afetam diretamente a estabilidade da liga\u00e7\u00e3o e a dist\u00e2ncia alcan\u00e7\u00e1vel.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b60e7e7e52a9466ea233a4e7ea1c76ab.jpg\" alt=\" Requisitos relativos \u00e0 fibra e ao cabeamento dos m\u00f3dulos SR SFP\" class=\"wp-image-3185\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b60e7e7e52a9466ea233a4e7ea1c76ab.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b60e7e7e52a9466ea233a4e7ea1c76ab-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b60e7e7e52a9466ea233a4e7ea1c76ab-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b60e7e7e52a9466ea233a4e7ea1c76ab-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b60e7e7e52a9466ea233a4e7ea1c76ab-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b6 Tipos de fibra multimodo (OM2 \/ OM3 \/ OM4)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Diferen\u00e7as de dist\u00e2ncia<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">As diferentes classes de fibra multimodo (MMF) suportam dist\u00e2ncias m\u00e1ximas diferentes para os componentes \u00f3ticos SR, devido \u00e0s limita\u00e7\u00f5es da largura de banda modal:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>OM2 (50\/125 \u00b5m)<\/strong><\/p><ul><li><p>Normalmente suporta liga\u00e7\u00f5es SR mais curtas (por exemplo, ~82 m para 10GBASE-SR)<\/p><\/li><li><p>Frequentemente encontradas em instala\u00e7\u00f5es empresariais antigas<\/p><\/li><\/ul><\/li><li><p><strong>OM3 (Fibra \u00d3tica Multimodo Otimizada para Laser)<\/strong><\/p><ul><li><p>Normalmente suporta at\u00e9 <strong>300 m<\/strong> a 10 Gbps<\/p><\/li><li><p>Amplamente implementado em centros de dados modernos<\/p><\/li><\/ul><\/li><li><p><strong>OM4 (Fibra \u00d3tica Multimodo Otimizada para Laser)<\/strong><\/p><ul><li><p>Normalmente suporta<br> <strong>400 m ou mais<\/strong> a 10 Gbps<\/p><\/li><li><p>Prefer\u00edvel para um desempenho superior e escalabilidade futura<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Capacidade de largura de banda<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>As fibras OM3 e OM4 est\u00e3o otimizadas para <strong>Transmiss\u00e3o VCSEL a 850 nm<\/strong>, oferecendo uma largura de banda modal efetiva superior \u00e0 do OM2.<\/p><\/li><li><p>A fibra monomodal (MMF) de maior largura de banda reduz a dispers\u00e3o modal, permitindo um alcance maior e uma melhor integridade do sinal a 10 Gbps e acima.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Orienta\u00e7\u00f5es de Engenharia<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Para novas implementa\u00e7\u00f5es, recomenda-se geralmente a utiliza\u00e7\u00e3o do OM4 nos casos em que se prevejam liga\u00e7\u00f5es mais longas dentro do centro de dados ou futuras atualiza\u00e7\u00f5es de velocidade.<\/p><\/li><li><p>A infraestrutura OM2 existente deve ser cuidadosamente verificada, uma vez que pode limitar a dist\u00e2ncia alcan\u00e7\u00e1vel ou a estabilidade a 10 Gbps.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b6 Tipos de conectores<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>LC Duplex<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>A maioria dos SFP SR e <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/476064.htm\">M\u00f3dulos SFP+<\/a> utilizar um <strong>conector \u00f3tico LC duplex<\/strong>.<\/p><\/li><li><p>A interface LC oferece:<\/p><ul><li><p>Formato compacto adequado para comutadores de elevada densidade de portas<\/p><\/li><li><p>Fibras separadas de transmiss\u00e3o (Tx) e rece\u00e7\u00e3o (Rx)<\/p><\/li><li><p>Baixa perda de inser\u00e7\u00e3o quando devidamente terminada<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Notas de implanta\u00e7\u00e3o<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Certifique-se de que a polaridade (A-B) est\u00e1 correta durante a liga\u00e7\u00e3o.<\/p><\/li><li><p>Utilize cabos de liga\u00e7\u00e3o de alta qualidade, com termina\u00e7\u00e3o de f\u00e1brica, para garantir um desempenho consistente.<\/p><\/li><li><p>A inspe\u00e7\u00e3o e limpeza regulares das ferrolhas LC s\u00e3o essenciais para evitar perdas \u00f3ticas e problemas de reflex\u00e3o.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b6 Considera\u00e7\u00f5es sobre o or\u00e7amento de liga\u00e7\u00e3o<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Um planeamento adequado do or\u00e7amento de liga\u00e7\u00e3o garante que a perda total do canal n\u00e3o exceda a margem de pot\u00eancia \u00f3tica suportada pelo transceptor SR.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Perda de inser\u00e7\u00e3o t\u00edpica<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Entre os colaboradores mais frequentes contam-se:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Atenua\u00e7\u00e3o da fibra (a fibra multimodo a 850 nm apresenta, normalmente, baixas perdas em dist\u00e2ncias curtas)<\/p><\/li><li><p>Perda no conector (cada par de conectores LC acoplados introduz, normalmente, uma perda de inser\u00e7\u00e3o mensur\u00e1vel)<\/p><\/li><li><p>Pain\u00e9is de liga\u00e7\u00e3o ou liga\u00e7\u00f5es cruzadas<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Em ambientes de centros de dados de curto alcance, a perda cumulativa no canal \u00e9 normalmente modesta, mas deve, mesmo assim, ser verificada durante a fase de conce\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Planeamento de margens<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Manter um <strong>margem \u00f3tica de reserva<\/strong> para ter em conta o envelhecimento, as varia\u00e7\u00f5es de temperatura e futuras adi\u00e7\u00f5es, mudan\u00e7as ou altera\u00e7\u00f5es.<\/p><\/li><li><p>Evite projetar liga\u00e7\u00f5es na dist\u00e2ncia m\u00e1xima absoluta suportada.<\/p><\/li><li><p>Verifique a perda de sinal real durante a coloca\u00e7\u00e3o em servi\u00e7o utilizando um medidor de pot\u00eancia ou <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/centro-de-conhecimento\/optical-time-domain-reflectometer-fiber-fault-detection-guide\/\">Testes com OTDR<\/a> sempre que poss\u00edvel.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Melhor Pr\u00e1tica<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Uma abordagem de conce\u00e7\u00e3o conservadora \u2014 MMF de alta qualidade, n\u00famero m\u00ednimo de conectores e limpeza comprovada \u2014 reduz significativamente os erros de pacotes, os alarmes DOM e os custos de manuten\u00e7\u00e3o a longo prazo nas implementa\u00e7\u00f5es de SFP SR.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u23e9 Compatibilidade do SR-SFP com os principais fornecedores de switches<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A interoperabilidade \u00e9 um dos aspetos mais importantes a ter em conta na aquisi\u00e7\u00e3o e implementa\u00e7\u00e3o de m\u00f3dulos SR SFP\/SFP+. Embora a norma \u00f3tica (por exemplo, 1000BASE-SX ou 10GBASE-SR) defina a sinaliza\u00e7\u00e3o, cada fabricante de switches pode implementar verifica\u00e7\u00f5es de valida\u00e7\u00e3o que determinam se um transceptor de terceiros \u00e9 aceite e totalmente suportado.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/96bbe8b6dfe449829baae451ad99f578.jpg\" alt=\"Compatibilidade do SR-SFP com os principais fornecedores de switches: Cisco, Arista, Juniper, HPE, etc.\" class=\"wp-image-3186\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/96bbe8b6dfe449829baae451ad99f578.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/96bbe8b6dfe449829baae451ad99f578-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/96bbe8b6dfe449829baae451ad99f578-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/96bbe8b6dfe449829baae451ad99f578-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/96bbe8b6dfe449829baae451ad99f578-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Suporte para Cisco, Arista, Juniper e HPE<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A maioria das plataformas empresariais e de centros de dados da <strong>Cisco, Arista, Juniper e HPE<\/strong> suportam \u00f3ticas SR em conformidade com as normas, mas o n\u00edvel de aceita\u00e7\u00e3o para <a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">terceiros compat\u00edveis<\/a> varia:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Cisco<\/strong><\/p><ul><li><p>Muitas plataformas validam a identidade do m\u00f3dulo atrav\u00e9s dos campos da EEPROM.<\/p><\/li><li><p>Alguns sistemas permitem a utiliza\u00e7\u00e3o de \u00f3ticas de terceiros, mas podem apresentar avisos ou limitar o suporte oficial da TAC.<\/p><\/li><li><p>Certos modos de funcionamento ou comandos podem permitir o funcionamento com m\u00f3dulos que n\u00e3o tenham a codifica\u00e7\u00e3o do fabricante original.<\/p><\/li><\/ul><\/li><li><p><strong>Arista<\/strong><\/p><ul><li><p>Em geral, \u00e9 mais compat\u00edvel com transceptores de terceiros que cumprem as normas.<\/p><\/li><li><p>Muitas vezes, funciona normalmente se a EEPROM do m\u00f3dulo estiver devidamente codificada para ser compat\u00edvel com a Arista.<\/p><\/li><\/ul><\/li><li><p><strong>Juniper<\/strong><\/p><ul><li><p>Normalmente, \u00e9 compat\u00edvel tanto com componentes \u00f3ticos do fabricante original (OEM) como com componentes \u00f3ticos de terceiros certificados.<\/p><\/li><li><p>Pode gerar notifica\u00e7\u00f5es de registo se o m\u00f3dulo n\u00e3o estiver codificado pelo fornecedor.<\/p><\/li><\/ul><\/li><li><p><strong>HPE (Aruba Networking)<\/strong><\/p><ul><li><p>Muitos switches empresariais aceitam m\u00f3dulos \u00f3ticos compat\u00edveis e certificados.<\/p><\/li><li><p>As pol\u00edticas de garantia e assist\u00eancia t\u00e9cnica podem recomendar m\u00f3dulos aprovados ou testados.<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Perspetivas sobre as aquisi\u00e7\u00f5es<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Verifique o exato <strong>modelo do switch e vers\u00e3o do sistema operativo<\/strong> antes da compra.<\/p><\/li><li><p>Verifique os procedimentos do fornecedor de <strong>matriz de compatibilidade de transceptores<\/strong> para evitar atrasos na implementa\u00e7\u00e3o.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Codifica\u00e7\u00e3o e qualifica\u00e7\u00e3o da EEPROM dos m\u00f3dulos SFP<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Cada m\u00f3dulo SFP\/SFP+ cont\u00e9m um <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/centro-de-conhecimento\/how-eeprom-powers-sfp-and-qsfp-optical-modules\/\">EEPROM<\/a> (por <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/centro-de-conhecimento\/sfp-8472-standard-explained-ddm-for-optical-transceivers\/\">SFF-8472<\/a>\/<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/centro-de-conhecimento\/sff-8431-sfp-plus-10g-electrical-specification\/\">SFF-8431<\/a> (estruturas) que armazenam dados de identifica\u00e7\u00e3o e de capacidades, incluindo:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Nome do fornecedor e OUI<\/p><\/li><li><p>N\u00famero de pe\u00e7a e revis\u00e3o<\/p><\/li><li><p>Muitos m\u00f3dulos tamb\u00e9m suportam Monitoramento \u00d3ptico Digital (<span class=\"math-inline\">)<\/span>)<\/p><\/li><li><p>Indicadores de compatibilidade com DOM\/DDM<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Por que \u00e9 que a programa\u00e7\u00e3o \u00e9 importante?<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>O firmware do switch l\u00ea estes campos durante a inicializa\u00e7\u00e3o.<\/p><\/li><li><p>A codifica\u00e7\u00e3o espec\u00edfica do fabricante garante que o m\u00f3dulo seja reconhecido como um dispositivo \u00f3tico aprovado.<\/p><\/li><li><p>Os fornecedores externos com qualifica\u00e7\u00f5es profissionais costumam fornecer <strong>codifica\u00e7\u00e3o program\u00e1vel para v\u00e1rios fornecedores<\/strong> adaptado \u00e0 plataforma de destino.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Melhor Pr\u00e1tica<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Solicite a codifica\u00e7\u00e3o de compatibilidade no momento da encomenda (por exemplo, codifica\u00e7\u00e3o Cisco, codifica\u00e7\u00e3o Arista).<\/p><\/li><li><p>Manter uma codifica\u00e7\u00e3o consistente em implementa\u00e7\u00f5es de grande escala para simplificar a gest\u00e3o do invent\u00e1rio e a resolu\u00e7\u00e3o de problemas.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Como evitar erros do tipo \u201cTransceptor n\u00e3o suportado\u201d<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u201cOs alarmes do tipo \u201dtransceptor n\u00e3o suportado\u00bb ou semelhantes ocorrem normalmente quando o comutador deteta um perfil de EEPROM n\u00e3o aprovado.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Causas comuns<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Codifica\u00e7\u00e3o incorreta ou gen\u00e9rica da EEPROM<\/p><\/li><li><p>Pol\u00edticas de firmware que imp\u00f5em a valida\u00e7\u00e3o do fornecedor<\/p><\/li><li><p>\u00d3ticas mistas provenientes de diferentes fontes com identificadores inconsistentes<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Medidas de mitiga\u00e7\u00e3o<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Confirme a codifica\u00e7\u00e3o necess\u00e1ria antes da instala\u00e7\u00e3o.<\/p><\/li><li><p>Testar um m\u00f3dulo de amostra no comutador de destino antes da implementa\u00e7\u00e3o em grande escala.<\/p><\/li><li><p>Mantenha as vers\u00f5es do firmware documentadas \u2014 algumas atualiza\u00e7\u00f5es tornam o comportamento de valida\u00e7\u00e3o mais rigoroso.<\/p><\/li><li><p>Trabalhar com fornecedores que ofere\u00e7am <strong>verifica\u00e7\u00e3o de compatibilidade pr\u00e9-expedi\u00e7\u00e3o<\/strong> e assist\u00eancia t\u00e9cnica RMA.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Recomenda\u00e7\u00e3o Operacional<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Em implementa\u00e7\u00f5es em grande escala, realizar uma breve valida\u00e7\u00e3o de interoperabilidade (teste em laborat\u00f3rio + <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/glossary\/ddm-dom-in-optical-transceivers\/\">DOM<\/a> (verifica\u00e7\u00e3o da leitura + verifica\u00e7\u00e3o da estabilidade da liga\u00e7\u00e3o) reduz significativamente o risco de falhas no terreno ou de atrasos no aprovisionamento.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u23e9 Cen\u00e1rios t\u00edpicos de implementa\u00e7\u00e3o dos m\u00f3dulos SR SFP<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Os m\u00f3dulos SR SFP est\u00e3o otimizados para <strong>liga\u00e7\u00f5es multimodo de curto alcance<\/strong>, tornando-os essenciais nas redes empresariais e nos centros de dados modernos. Combinam <strong>baixo consumo de energia, boa rela\u00e7\u00e3o custo-benef\u00edcio e formato compacto<\/strong>, ideais para implementa\u00e7\u00f5es de alta densidade, em que as dist\u00e2ncias raramente excedem algumas centenas de metros. A seguir apresentam-se os cen\u00e1rios de implementa\u00e7\u00e3o mais comuns para os m\u00f3dulos SR SFP e SFP+.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/91e2109b59fd4f27b4b89a9f06677b4a.jpg\" alt=\"Cen\u00e1rios t\u00edpicos de implementa\u00e7\u00e3o dos m\u00f3dulos SR SFP: comuta\u00e7\u00e3o em rack \/ ToR, centro de dados, acesso empresarial\" class=\"wp-image-3187\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/91e2109b59fd4f27b4b89a9f06677b4a.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/91e2109b59fd4f27b4b89a9f06677b4a-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/91e2109b59fd4f27b4b89a9f06677b4a-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/91e2109b59fd4f27b4b89a9f06677b4a-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/91e2109b59fd4f27b4b89a9f06677b4a-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >1. Comuta\u00e7\u00e3o no rack \/ ToR<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caso de Uso:<\/strong> Liga\u00e7\u00f5es curtas entre servidores e <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/pt\/centro-de-conhecimento\/o-que-e-um-switch-tor-top-of-rack\/\">Topo do Rack<\/a> Comutadores (ToR) dentro de um \u00fanico rack.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Dist\u00e2ncia t\u00edpica:<\/strong> &lt;100 m<\/p><\/li><li><p><strong>Tipo de fibra:<\/strong> Fibra multimodo OM3 \/ OM4<\/p><\/li><li><p><strong>Vantagens:<\/strong><\/p><ul><li><p>Perda de inser\u00e7\u00e3o e lat\u00eancia m\u00ednimas<\/p><\/li><li><p>Econ\u00f3mico para racks com um elevado n\u00famero de portas<\/p><\/li><li><p>Integra\u00e7\u00e3o perfeita com a infraestrutura MMF existente<br\/><strong>Observa\u00e7\u00f5es:<\/strong> Frequentemente utilizados em liga\u00e7\u00f5es de 1G ou 10G, os m\u00f3dulos SR processam de forma eficiente o tr\u00e1fego de elevado d\u00e9bito em implementa\u00e7\u00f5es com racks densos.<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >2. Agrega\u00e7\u00e3o de centros de dados de alta densidade<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caso de Uso:<\/strong> Agrupar v\u00e1rios switches ToR ou switches de folha em switches de espinha dorsal dentro do mesmo centro de dados.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Dist\u00e2ncia t\u00edpica:<\/strong> 100\u2013300 m<\/p><\/li><li><p><strong>Tipo de fibra:<\/strong> Fibra multimodo OM3 \/ OM4<\/p><\/li><li><p><strong>Vantagens:<\/strong><\/p><ul><li><p>Suporta agrega\u00e7\u00e3o com elevado n\u00famero de portas<\/p><\/li><li><p>Mant\u00e9m uma baixa lat\u00eancia no tr\u00e1fego leste-oeste<\/p><\/li><li><p>Consumo energ\u00e9tico eficiente para ambientes de alta densidade<br\/><strong>Observa\u00e7\u00f5es:<\/strong> <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/476060.htm\">SR SFP+<\/a> Os m\u00f3dulos s\u00e3o a op\u00e7\u00e3o preferida quando \u00e9 necess\u00e1ria uma agrega\u00e7\u00e3o com crit\u00e9rios de custo, sem a necessidade de liga\u00e7\u00f5es monomodo.<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >3. Interliga\u00e7\u00f5es da camada de acesso empresarial<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caso de Uso:<\/strong> Liga\u00e7\u00e3o de switches de acesso \u00e0s camadas de distribui\u00e7\u00e3o ou centrais nas redes de campus.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Dist\u00e2ncia t\u00edpica:<\/strong> 300\u2013400 m (dependendo do tipo de fibra)<\/p><\/li><li><p><strong>Tipo de fibra:<\/strong> Fibra multimodo OM3 \/ OM4<\/p><\/li><li><p><strong>Vantagens:<\/strong><\/p><ul><li><p>Suporta dist\u00e2ncias t\u00edpicas da rede principal de um campus<\/p><\/li><li><p>Baixo custo operacional para liga\u00e7\u00f5es empresariais de curto alcance<\/p><\/li><li><p>F\u00e1cil de implementar e manter<br\/><strong>Observa\u00e7\u00f5es:<\/strong> As solu\u00e7\u00f5es \u00f3pticas SR constituem uma solu\u00e7\u00e3o fi\u00e1vel para as liga\u00e7\u00f5es entre empresas em que n\u00e3o \u00e9 necess\u00e1ria a implanta\u00e7\u00e3o de fibra monomodo.<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Tabela de cen\u00e1rios de implementa\u00e7\u00e3o do m\u00f3dulo SR SFP<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Cen\u00e1rio de implanta\u00e7\u00e3o<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Ambiente<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Dist\u00e2ncia t\u00edpica<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>M\u00f3dulo recomendado<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Fundamenta\u00e7\u00e3o \/ Vantagens<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Comuta\u00e7\u00e3o no rack \/ ToR<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Liga\u00e7\u00f5es curtas dentro do mesmo rack<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>&lt;100 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/476067.htm\">10GBASE-SR SFP+<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Baixo custo, consumo m\u00ednimo de energia, ideal para racks de alta densidade e liga\u00e7\u00f5es no topo do rack<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Agrega\u00e7\u00e3o de centros de dados de alta densidade<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>V\u00e1rios racks ligados entre si numa sala de servidores<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>100\u2013300 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10GBASE-SR SFP+<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Suporta fibra multimodo, \u00e9 econ\u00f3mica e \u00e9 frequentemente utilizada para agrega\u00e7\u00e3o de troncos e ramifica\u00e7\u00f5es<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Interliga\u00e7\u00f5es da camada de acesso empresarial<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Liga\u00e7\u00f5es entre edif\u00edcios ou liga\u00e7\u00f5es curtas no campus<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>300\u2013550 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10GBASE-SR SFP+ ou <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/478230.htm\">SFP 1000BASE-SX<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Compat\u00edvel com OM3\/OM4 MMF, mant\u00e9m a margem de liga\u00e7\u00e3o e permite uma implementa\u00e7\u00e3o flex\u00edvel em redes empresariais<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u23e9 Perfil t\u00e9rmico e de alimenta\u00e7\u00e3o do m\u00f3dulo SR SFP<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Os m\u00f3dulos SR SFP foram concebidos para aplica\u00e7\u00f5es multimodo de baixa pot\u00eancia e curta dist\u00e2ncia, o que os torna ideais para implementa\u00e7\u00f5es em centros de dados de alta densidade. Compreender o seu consumo de energia e as suas caracter\u00edsticas t\u00e9rmicas \u00e9 fundamental para garantir a fiabilidade da rede e o arrefecimento adequado do chassis.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8ff8745a528e43039bd113cd52881db7.jpg\" alt=\"Perfil t\u00e9rmico e de pot\u00eancia do m\u00f3dulo SR SFP\" class=\"wp-image-3188\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8ff8745a528e43039bd113cd52881db7.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8ff8745a528e43039bd113cd52881db7-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8ff8745a528e43039bd113cd52881db7-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8ff8745a528e43039bd113cd52881db7-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8ff8745a528e43039bd113cd52881db7-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Intervalo t\u00edpico de consumo de energia<\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Tipo de M\u00f3dulo<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Consumo T\u00edpico de Energia<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>SFP (definido pelo MSA)<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>SFP 1000BASE-SX<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>0,8\u20131,0 W<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Transceptor multimodo Gigabit padr\u00e3o de curto alcance<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>10GBASE-SR SFP+<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1,0\u20131,5 W<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Implementa\u00e7\u00e3o em grande escala em liga\u00e7\u00f5es ToR e de agrega\u00e7\u00e3o<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>A pot\u00eancia varia ligeiramente consoante o fabricante e a compatibilidade com DDM\/DOM.<\/p><\/li><li><p>Um consumo de energia mais baixo contribui para reduzir as necessidades totais de refrigera\u00e7\u00e3o e os custos operacionais.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Implica\u00e7\u00f5es dos comutadores de alta densidade<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Ao instalar dezenas ou centenas de m\u00f3dulos SR SFP\/SFP+ num \u00fanico chassis, o consumo de energia acumulado pode afetar os perfis t\u00e9rmicos do comutador.<\/p><\/li><li><p>Assegure um fluxo de ar adequado (da frente para tr\u00e1s ou de tr\u00e1s para a frente), de acordo com as especifica\u00e7\u00f5es do interruptor.<\/p><\/li><li><p>A monitoriza\u00e7\u00e3o do DOM pode ajudar a acompanhar a temperatura do m\u00f3dulo e a detetar pontos de sobreaquecimento numa fase precoce, evitando a redu\u00e7\u00e3o do desempenho ou falhas de liga\u00e7\u00e3o.<\/p><\/li><li><p>\u00c9 essencial planear a pot\u00eancia por ranhura e a pot\u00eancia total do chassis ao dimensionar racks de alta densidade com v\u00e1rios m\u00f3dulos SR SFP.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u23e9 Como escolher o m\u00f3dulo SFP SR adequado <\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A sele\u00e7\u00e3o do m\u00f3dulo SFP SR ideal requer um equil\u00edbrio entre os requisitos de dist\u00e2ncia, o tipo de fibra, a compatibilidade com os fornecedores e as considera\u00e7\u00f5es relativas ao consumo de energia e \u00e0 gest\u00e3o t\u00e9rmica. Seguir uma lista de verifica\u00e7\u00e3o estruturada garante uma implementa\u00e7\u00e3o fi\u00e1vel e simplifica as decis\u00f5es de aquisi\u00e7\u00e3o.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/25eab0898b714b9f8da0dd0a2487f144.jpg\" alt=\"Como escolher o m\u00f3dulo SR SFP adequado \" class=\"wp-image-3189\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/25eab0898b714b9f8da0dd0a2487f144.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/25eab0898b714b9f8da0dd0a2487f144-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/25eab0898b714b9f8da0dd0a2487f144-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/25eab0898b714b9f8da0dd0a2487f144-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/25eab0898b714b9f8da0dd0a2487f144-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2460 Dist\u00e2ncia e tipo de fibra, em primeiro lugar<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Determine a dist\u00e2ncia de liga\u00e7\u00e3o necess\u00e1ria: os m\u00f3dulos SFP SR t\u00edpicos t\u00eam um alcance de at\u00e9 <strong>300 m em OM3<\/strong> and <strong>400 m no OM4<\/strong> .<\/p><\/li><li><p>Escolha o tipo de fibra (OM2\/OM3\/OM4) de acordo com a dist\u00e2ncia prevista e os requisitos de largura de banda.<\/p><\/li><li><p>Para liga\u00e7\u00f5es mais curtas (&lt;100 m), poder\u00e1 ser suficiente utilizar fibra de qualidade inferior ou alternativas passivas ao DAC.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2461 Verificar a compatibilidade do fornecedor<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Confirme se o seu fornecedor de switches suporta o m\u00f3dulo: <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/476059.htm\"><strong>Cisco<\/strong><\/a><strong>, <\/strong><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/482145.htm\"><strong>Arista<\/strong><\/a><strong>, <\/strong><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/482246.htm\"><strong>Juniper<\/strong><\/a><strong>, <\/strong><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/476073.htm\"><strong>HPE<\/strong><\/a>, etc.<\/p><\/li><li><p>Verifique a codifica\u00e7\u00e3o e a qualifica\u00e7\u00e3o da EEPROM para evitar erros do tipo \u201ctransceptor n\u00e3o suportado\u201d.<\/p><\/li><li><p>Opte por m\u00f3dulos com valida\u00e7\u00e3o de v\u00e1rios fornecedores se a sua rede incluir marcas diferentes.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2462 Confirmar as necessidades de monitoriza\u00e7\u00e3o do DOM<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Determinar se <strong>Suporte DOM\/DDM<\/strong> \u00e9 necess\u00e1rio para a monitoriza\u00e7\u00e3o em tempo real da pot\u00eancia \u00f3tica, da temperatura e da corrente de polariza\u00e7\u00e3o do laser.<\/p><\/li><li><p>\u00c9 essencial em centros de dados de alta densidade para evitar a degrada\u00e7\u00e3o indetetada das liga\u00e7\u00f5es.<\/p><\/li><li><p>Os m\u00f3dulos sem DOM podem ser suficientes para liga\u00e7\u00f5es curtas e de baixa criticidade.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2463 Verificar o or\u00e7amento de pot\u00eancia dos SFPs<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Verifique o consumo de energia por porta (normalmente <strong>0,8\u20131,5 W<\/strong>) e garantir que o chassis ou o comutador disp\u00f5e de margem t\u00e9rmica adequada.<\/p><\/li><li><p>As implementa\u00e7\u00f5es de alta densidade exigem um planeamento da pot\u00eancia e do fluxo de ar acumulados.<\/p><\/li><li><p>Considere variantes de baixo consumo energ\u00e9tico para garantir a efici\u00eancia energ\u00e9tica e reduzir os custos de refrigera\u00e7\u00e3o.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2464 Tabela de verifica\u00e7\u00e3o para a escolha do m\u00f3dulo SR SFP<\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Fator de sele\u00e7\u00e3o<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Recomenda\u00e7\u00e3o \/ Limite<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Observa\u00e7\u00f5es \/ Considera\u00e7\u00f5es<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Dist\u00e2ncia da liga\u00e7\u00e3o<br><\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2264 300 m em OM3, \u2264 400 m em OM4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Verifique o tipo de fibra utilizado e a dist\u00e2ncia de instala\u00e7\u00e3o; preveja uma margem para os cabos de liga\u00e7\u00e3o<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Tipo de fibra<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>OM2 \/ OM3 \/ OM4 multimodo<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>OM3\/OM4 s\u00e3o as op\u00e7\u00f5es preferidas para liga\u00e7\u00f5es ToR e de agrega\u00e7\u00e3o de elevada largura de banda<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Compatibilidade com Fornecedor<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Verificado pela Cisco, Arista, Juniper e HPE<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Verifique a codifica\u00e7\u00e3o da EEPROM para evitar erros do tipo \u201ctransceptor n\u00e3o suportado\u201d; recomenda-se o suporte a v\u00e1rios fabricantes<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Suporte a DOM \/ DDM<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Necess\u00e1rio para a monitoriza\u00e7\u00e3o de liga\u00e7\u00f5es cr\u00edticas<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fornece dados em tempo real sobre a pot\u00eancia de transmiss\u00e3o\/recep\u00e7\u00e3o, a temperatura e a corrente de polariza\u00e7\u00e3o do laser; opcional para liga\u00e7\u00f5es curtas e n\u00e3o cr\u00edticas<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Consumo de Energia<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Normalmente, 0,8\u20131,5 W por porta<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Confirme a margem t\u00e9rmica do comutador\/chassis; considere op\u00e7\u00f5es de baixo consumo energ\u00e9tico para racks com alta densidade<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Cen\u00e1rio de implanta\u00e7\u00e3o<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Termos de Refer\u00eancia do centro de dados, agrega\u00e7\u00e3o, liga\u00e7\u00f5es de campus<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Escolha com base na dist\u00e2ncia da liga\u00e7\u00e3o, no tipo de fibra e nas necessidades de monitoriza\u00e7\u00e3o<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Notas sobre custos e aquisi\u00e7\u00f5es<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Os SR SFP s\u00e3o normalmente de grande volume e baixo custo<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Os m\u00f3dulos OEM versus os compat\u00edveis, a disponibilidade de stock e o prazo de entrega influenciam as decis\u00f5es de aquisi\u00e7\u00e3o<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u23e9 Perguntas frequentes sobre o m\u00f3dulo SR SFP<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7ed90dedef4b4f6a9edf650bab375835.jpg\" alt=\"Perguntas frequentes sobre o m\u00f3dulo SR SFP\" class=\"wp-image-3190\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7ed90dedef4b4f6a9edf650bab375835.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7ed90dedef4b4f6a9edf650bab375835-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7ed90dedef4b4f6a9edf650bab375835-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7ed90dedef4b4f6a9edf650bab375835-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7ed90dedef4b4f6a9edf650bab375835-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >P1: O que significa SR em SFP?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R:<\/strong> SR significa <em>Curto alcance<\/em>. Os m\u00f3dulos SR SFP foram concebidos para liga\u00e7\u00f5es de fibra multimodo, funcionando normalmente a 850 nm e utilizando lasers VCSEL para a transmiss\u00e3o de dados a curta dist\u00e2ncia.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >P2: Que dist\u00e2ncia suporta o SR?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R:<\/strong> Os m\u00f3dulos SR suportam normalmente dist\u00e2ncias at\u00e9 cerca de 300 metros em fibra multimodo OM3 e cerca de 400 metros em fibra multimodo OM4, dependendo da norma (1000BASE-SX ou 10GBASE-SR).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >P3: O SR pode funcionar em fibra monomodo?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R:<\/strong> N\u00e3o. Os SFP SR est\u00e3o otimizados para fibra multimodo (MMF). A sua utiliza\u00e7\u00e3o em fibra monomodo (SMF) pode causar perda de sinal e problemas de desempenho.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >P4: O SR \u00e9 mais barato do que o LR?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R:<\/strong> Sim. Os m\u00f3dulos SR t\u00eam, geralmente, um custo por liga\u00e7\u00e3o inferior ao dos m\u00f3dulos LR (longo alcance), principalmente porque os transceptores de fibra multimodo requerem componentes \u00f3ticos menos precisos e um menor consumo de energia.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >P5: Os m\u00f3dulos SR de terceiros s\u00e3o fi\u00e1veis?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R:<\/strong> Os m\u00f3dulos SR de terceiros de alta qualidade podem ser fi\u00e1veis se cumprirem as normas IEEE e inclu\u00edrem uma codifica\u00e7\u00e3o EEPROM adequada para garantir a compatibilidade com os fornecedores. No entanto, verifique sempre as credenciais do fornecedor e realize testes antes da implementa\u00e7\u00e3o em massa.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >P6: Os m\u00f3dulos SR suportam o DOM?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R:<\/strong> Sim. A maioria dos m\u00f3dulos SR SFP e SFP+ suporta DOM (Digital Optical Monitoring), permitindo a monitoriza\u00e7\u00e3o em tempo real da pot\u00eancia \u00f3tica, da temperatura e da tens\u00e3o de alimenta\u00e7\u00e3o.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >P7: O SR e o DAC podem coexistir no mesmo switch?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R:<\/strong> Sim. Muitos switches permitem a utiliza\u00e7\u00e3o simult\u00e2nea de SFP SR e cabos DAC. Certifique-se de que a configura\u00e7\u00e3o da porta, a velocidade e o mapeamento de vias s\u00e3o compat\u00edveis, para evitar erros de liga\u00e7\u00e3o.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u23e9 Melhores pr\u00e1ticas de implementa\u00e7\u00e3o e m\u00f3dulos SR \u2013 Recursos adicionais<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Testes de interoperabilidade<\/strong><br\/>Realizar testes entre diferentes fornecedores para garantir que <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/475415.htm\">M\u00f3dulo SFP SR<\/a> Funciona de forma fi\u00e1vel com os seus comutadores, DACs ou AOCs. Verifique a estabilidade da liga\u00e7\u00e3o sob carga e detete mensagens de transceptores n\u00e3o suportadas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Verifica\u00e7\u00e3o da pot\u00eancia \u00f3tica<\/strong><br\/>Me\u00e7a a pot\u00eancia de transmiss\u00e3o (Tx) e de rece\u00e7\u00e3o (Rx) e a margem da liga\u00e7\u00e3o para confirmar a conformidade com as normas IEEE 802.3. Certifique-se de que a perda de inser\u00e7\u00e3o e a dist\u00e2ncia n\u00e3o excedem as especifica\u00e7\u00f5es do m\u00f3dulo SR.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Etiquetagem e gest\u00e3o de ativos<\/strong><br\/>Utilize uma identifica\u00e7\u00e3o clara para cada m\u00f3dulo, fibra e porta do painel de liga\u00e7\u00f5es. Mantenha um registo de invent\u00e1rio para facilitar a manuten\u00e7\u00e3o, a substitui\u00e7\u00e3o e a resolu\u00e7\u00e3o de problemas da rede.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Outros recursos e ferramentas de compatibilidade<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Fichas t\u00e9cnicas:<\/strong> Especifica\u00e7\u00f5es detalhadas para cada variante do SR SFP.<\/p><\/li><li><p><strong>Matriz de compatibilidade:<\/strong> Verifique se os comutadores dos fornecedores e os m\u00f3dulos s\u00e3o compat\u00edveis.<\/p><\/li><li><p><strong>Guia de sele\u00e7\u00e3o SR\/LR:<\/strong> Guia r\u00e1pido para a escolha das \u00f3pticas adequadas.<\/p><\/li><li><p><strong>Solicitar verifica\u00e7\u00e3o de compatibilidade:<\/strong> Envie as informa\u00e7\u00f5es do m\u00f3dulo e do comutador para verifica\u00e7\u00e3o pela assist\u00eancia t\u00e9cnica do fornecedor ou por especialistas no produto.<\/p><\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/442ae4a2c3784cffb836a8c69c80ccaa.jpg\" alt=\"M\u00f3dulos LINK-PP SR\" class=\"wp-image-3191\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/442ae4a2c3784cffb836a8c69c80ccaa.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/442ae4a2c3784cffb836a8c69c80ccaa-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/442ae4a2c3784cffb836a8c69c80ccaa-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/442ae4a2c3784cffb836a8c69c80ccaa-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/442ae4a2c3784cffb836a8c69c80ccaa-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udca1 Explore e compre m\u00f3dulos SR SFP verificados na <a target=\"_self\" href=\"https:\/\/www.l-p.com\/\"><strong>Loja Oficial LINK-PP<\/strong><\/a> para uma conectividade de curto alcance fi\u00e1vel e de alto desempenho.<\/p>","protected":false},"excerpt":{"rendered":"<p>Este guia explica os m\u00f3dulos SFP SR, incluindo comprimento de onda, requisitos de fibra, alcance t\u00edpico, problemas de compatibilidade e dicas de sele\u00e7\u00e3o para redes \u00f3pticas de curto alcance.<\/p>","protected":false},"author":1,"featured_media":3192,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[28],"tags":[26],"class_list":["post-3193","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts\/3193","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/comments?post=3193"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts\/3193\/revisions"}],"predecessor-version":[{"id":10774,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/posts\/3193\/revisions\/10774"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/media\/3192"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/media?parent=3193"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/categories?post=3193"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/pt\/wp-json\/wp\/v2\/tags?post=3193"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}