{"id":5813,"date":"2025-07-11T00:00:00","date_gmt":"2025-07-11T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/what-is-the-difference-between-nrz-and-pam4\/"},"modified":"2026-06-22T09:06:48","modified_gmt":"2026-06-22T09:06:48","slug":"what-is-the-difference-between-nrz-and-pam4","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/what-is-the-difference-between-nrz-and-pam4","title":{"rendered":"NRZ versus PAM4: het begrijpen van de belangrijkste verschillen"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/05091a803b6a4dbdbdb66f8a4b45136c.webp\" alt=\"What is the difference between NRZ and PAM4?\" class=\"wp-image-5807\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/05091a803b6a4dbdbdb66f8a4b45136c.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/05091a803b6a4dbdbdb66f8a4b45136c-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/05091a803b6a4dbdbdb66f8a4b45136c-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/05091a803b6a4dbdbdb66f8a4b45136c-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/05091a803b6a4dbdbdb66f8a4b45136c-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Belangrijkste verschillen tussen PAM4 en NRZ<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Verken de modulatieverschillen tussen PAM4 en NRZ voor moderne netwerken.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Eigenschap<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>NRZ (Non-Return to Zero)<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>PAM4 (Pulse Amplitude Modulation met 4 niveaus)<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Niveaus<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>2 (bijv. Laag=0, Hoog=1)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 (bijv. L0=00, L1=01, L2=10, L3=11)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Bits per symbool<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>2<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Effici\u00ebntie van gegevenssnelheid<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lager (Gegevenssnelheid = symboolsnelheid)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Hoger (Gegevenssnelheid = 2 \u00d7 symboolsnelheid)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Symboolsnelheid (Baud) bij dezelfde gegevenssnelheid<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Hoger (bijv. 56 GBaud voor 56 Gbps)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lager (bijv. 28 GBaud voor 56 Gbps)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Gevoeligheid voor ruis<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lager (Grotere oogopening, hogere SNR-marge)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Hoger (Kleinere oogopening, lagere SNR-marge)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Implementatiecomplexiteit<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lager<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Hoger (Vereist DSP, sterke FEC)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Typisch vermogen per bit<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lager (Volwassen technologie)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Hoger (Complexiteits overhead)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Dominante gegevenssnelheden<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2264 25 Gbps per kanaal (bijv. 10G, 25G SFP+)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2265 50 Gbps per kanaal (bijv. 100G, 200G, 400G, 800G)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Belangrijke toepassingen<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Verouderde 10G\/25G-, kortbereikinterfaces<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Snelle datacenters (100G+), HPC, AI\/ML-clusters, 5G fronthaul\/midhaul<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">U ziet netwerken snel veranderen terwijl datacenters meer snelheid nodig hebben. De <strong>PAM4 versus NRZ<\/strong> discussie is belangrijk omdat PAM4 twee bits per symbool verzendt, terwijl NRZ slechts \u00e9\u00e9n bit per symbool verzendt. Deze wijziging maakt het bandbreedtegebruik twee keer zo effici\u00ebnt voor nieuwe Ethernet-standaarden, zonder extra kanaalbandbreedte te gebruiken. In datacenters is het verschil tussen PAM4 en NRZ relevant omdat PAM4 vier amplitude-niveaus gebruikt, terwijl NRZ er slechts twee gebruikt. Wanneer netwerken sneller worden, helpt PAM4-modulatie om gegevens sneller en beter te verzenden.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Belangrijkste conclusies<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>PAM4<\/strong> verzendt twee bits per symbool. Het gebruikt vier spanningsniveaus. Dit zorgt ervoor dat gegevens twee keer zo snel worden overgebracht als met NRZ. NRZ verzendt slechts \u00e9\u00e9n bit per symbool. Het gebruikt slechts twee spanningsniveaus.<\/p><\/li><li><p><strong>NRZ<\/strong> heeft sterkere signalen. Het heeft minder ruis en gebruikt minder energie. Dit maakt het eenvoudiger in gebruik. Het werkt beter voor lange afstanden of langzamere netwerken.<\/p><\/li><li><p>PAM4 werkt het beste voor snelle, korte verbindingen. Het wordt gebruikt in 400G Ethernet en datacenters. Het vereist speciale foutcorrectie. Het gebruikt ook meer energie.<\/p><\/li><li><p>U kiest PAM4 of NRZ op basis van uw netwerk. Denk na over snelheid, afstand, kosten en toekomstige behoeften.<\/p><\/li><li><p>Het gebruik van zowel PAM4 als NRZ in een netwerk kan nuttig zijn. Het biedt een evenwicht tussen snelheid en betrouwbaarheid. Het helpt ook bij voorbereiding op toekomstige upgrades.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Basisprincipes van modulatie<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Wat is NRZ?<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"486\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ce3795470145420dba9b9d02e500e6f1.webp\" alt=\"NRZ encoding\" class=\"wp-image-5808\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ce3795470145420dba9b9d02e500e6f1.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ce3795470145420dba9b9d02e500e6f1-300x122.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ce3795470145420dba9b9d02e500e6f1-1024x415.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ce3795470145420dba9b9d02e500e6f1-768x311.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ce3795470145420dba9b9d02e500e6f1-18x7.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/understanding-non-return-to-zero-in-digital-communication\/\"><strong>NRZ<\/strong><\/a> is een eenvoudige manier om signalen te verzenden. Het staat voor<br> <strong>non-return to zero<br><\/strong>. Deze methode gebruikt twee spanningen om binaire gegevens weer te geven. Een \u20181\u2019 is een hoge spanning. Een \u20180\u2019 is een lage spanning. Het signaal keert niet terug naar nul tussen de bits. Dit houdt de zaak eenvoudig begrijpelijk. Bij unipolaire NRZ is \u20181\u2019 een positieve spanning en \u20180\u2019 nul volt. Bij bipolaire NRZ wisselt het signaal tussen positieve en negatieve spanning.<br>. <\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px 0px 4px;\"><strong>Twee niveaus:<br><\/strong> Het gebruikt twee duidelijke spanning- (elektrisch) of lichtintensiteits- (optisch) niveaus.<br>.<\/p><ul><li><p style=\"margin: 0px;\">Een hoog niveau vertegenwoordigt meestal een logische \u20181\u2019.<br>.<\/p><\/li><li><p style=\"margin: 0px;\">Een laag niveau vertegenwoordigt een logische \u20180\u2019.<br>.<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px;\"><strong>Eenvoudige werking:<br><\/strong> Elke symboolperiode zendt ofwel een \u20181\u2019 ofwel een \u20180\u2019 uit. Het signaal keert niet terug naar een neutrale \u201cnul\u201d-toestand tussen bits met dezelfde waarde (vandaar \u201cNon-Return to Zero\u201d).<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Voordelen:<\/strong> Door deze eenvoud is NRZ robuust en relatief eenvoudig te implementeren, met een lagere stroomverbruik en minder complexe signaalverwerkingsvereisten. Het biedt uitstekende signaalintegriteit bij lagere datarates.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Beperkingen:<\/strong> De effici\u00ebntie bereikt echter een grens. Om de datarate te verdubbelen, moet de symboolrate (baudrate) worden verdubbeld. Verdubbeling van de baudrate verhoogt de signaalvervorming aanzienlijk door kanaalverlies, ruis en koppeling, waardoor het onpraktisch wordt boven ca. 25\u201328 Gigabaud per kanaal voor mainstream-toepassingen.<br>.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Wat is PAM4?<br><\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"516\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8766e10c7cab415784322b28ebf4f58b.webp\" alt=\"PAM4 encoding\" class=\"wp-image-5809\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8766e10c7cab415784322b28ebf4f58b.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8766e10c7cab415784322b28ebf4f58b-300x129.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8766e10c7cab415784322b28ebf4f58b-1024x440.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8766e10c7cab415784322b28ebf4f58b-768x330.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8766e10c7cab415784322b28ebf4f58b-18x8.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\"><strong>PAM4<\/strong><\/a> is een manier om meer gegevens tegelijk te verzenden. Het staat voor<br> <strong>pulse amplitude modulation 4-level<br><\/strong>. Het gebruikt vier spanningsniveaus om twee bits per symbool weer te geven. Hierdoor kunt u tweemaal zoveel gegevens verzenden als met NRZ in dezelfde tijd. PAM4 is een vorm van pulsamplitudemodulatie die het bandbreedtegebruik verbetert. Elk symbool in PAM4 staat voor een paar bits, zoals 00, 01, 10 of 11. Dit maakt het mogelijk meer gegevens te verzenden zonder extra kanaalbandbreedte te nodig te hebben.<br>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Vier niveaus:<br><\/strong> PAM4 gebruikt<br> <em>vier<br><\/em> duidelijke spanning- of lichtintensiteitsniveaus.<br>.<\/p><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>Twee bits per symbool:<br><\/strong> Elke symboolperiode draagt nu<br> <em>twee<br><\/em> bits informatie:<br><\/p><ul><li><p style=\"margin: 0px;\">Niveau 0: \u201900\u2019<br>\u2019<\/p><\/li><li><p style=\"margin: 0px;\">Niveau 1: \u201901\u2019<br>\u2019<\/p><\/li><li><p style=\"margin: 0px;\">Niveau 2: \u201910\u2019<br>\u2019<\/p><\/li><li><p style=\"margin: 0px;\">Niveau 3: \u201911\u2019<br>\u2019<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px;\"><strong>Verdubbeling van effici\u00ebntie:<br><\/strong> Door twee bits per symbool te verzenden, bereikt PAM4 een tweemaal zo hoge datarate als NRZ<br> <em>bij dezelfde baudrate<\/em>. Een 28 Gigabaud PAM4-signaal levert 56 gigabit per seconde (Gbps) per kanaal, terwijl NRZ bij die baudfrequentie slechts 28 Gbps zou leveren.<\/p><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>Uitdagingen:<\/strong> Deze effici\u00ebntie heeft een prijs:<\/p><ul><li><p style=\"margin: 0px;\"><strong>Verminderde signaal-ruisverhouding (SNR):<\/strong> De vier niveaus liggen dichter bij elkaar dan de twee niveaus van NRZ. Dit maakt het signaal veel gevoeliger voor ruis, vervorming en interferentie. Een kleinere ruismarge kan een niveau omdraaien en fouten veroorzaken.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Grotere complexiteit:<\/strong> PAM4 vereist aanzienlijk geavanceerdere transceiverontwerpen, inclusief krachtige <strong>Forward Error Correction (FEC)<\/strong>, geavanceerd <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/digital-signal-processor-functionality-in-optical-transceivers\/\"><strong>DSP (Digitale Signaalverwerking)<\/strong><\/a>, en nauwkeurige lineariteit in drivers en receivers. Dit vertaalt zich over het algemeen naar een hoger stroomverbruik per bit vergeleken met volwassen NRZ-ontwerpen.<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Opmerking: PAM4 heeft meer spanningsniveaus, dus de afstand tussen deze niveaus is kleiner. Dit maakt PAM4-signalen gevoeliger voor ruis dan NRZ.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >Waarom modulatie belangrijk is<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/what-is-optical-modulation-and-how-it-works-explained\/\"><strong>Modulatie<\/strong><\/a> Modulatie is nodig om digitale gegevens over draden of glasvezel te verzenden. Het wijzigt het signaal zodat het verder kan reizen met minder problemen. Voor snelle gegevensoverdracht helpen externe modulatieapparaten, zoals een Mach-Zehnder-modulator, het signaal krachtig te houden. Pulsvormamplitude-modulatie en andere signaalwijzigingsmethoden helpen u de beste balans te vinden tussen snelheid, effici\u00ebntie en betrouwbaarheid.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Oogdiagrammen en signaalintegriteit<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >NRZ-oogdiagram<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"659\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e1f1ed087d5b4594a6e4af41382f1e6e.webp\" alt=\"NRZ eye diagram\" class=\"wp-image-5810\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e1f1ed087d5b4594a6e4af41382f1e6e.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e1f1ed087d5b4594a6e4af41382f1e6e-300x165.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e1f1ed087d5b4594a6e4af41382f1e6e-1024x562.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e1f1ed087d5b4594a6e4af41382f1e6e-768x422.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e1f1ed087d5b4594a6e4af41382f1e6e-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Wanneer u naar een <strong>NRZ-oogdiagram<\/strong>, kijkt, ziet u hoe het signaal werkt. Er zijn twee hoofdspanningsniveaus, \u00e9\u00e9n voor 0 en \u00e9\u00e9n voor 1. Dit vormt een groot, open \u201coog\u201d-vormig patroon in het diagram. Het open oog betekent dat het signaal sterk is en niet gemakkelijk door ruis wordt verstoord.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>U ziet twee duidelijke spanningsniveaus, dus 0 en 1 zijn eenvoudig van elkaar te onderscheiden.<\/p><\/li><li><p>De brede oogopening betekent dat het signaal sterk is en weinig wordt gewijzigd.<\/p><\/li><li><p>Vloeiende overgangen tussen niveaus helpen u de timing bij te houden en minder fouten te maken.<\/p><\/li><li><p>Het hoge gedeelte van het oog toont hoeveel ruis het signaal kan verdragen.<\/p><\/li><li><p>Het brede gedeelte toont of er sprake is van tijdsjitter of intersymboolinterferentie.<\/p><\/li><li><p>Een groter oog betekent minder fouten en eenvoudigere timing.<\/p><\/li><li><p>Als het oog kleiner wordt, veroorzaken ruis of problemen een verslechtering van het signaal.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">NRZ-oogdiagrammen zijn eenvoudig en minder ingewikkeld dan PAM4. Dit maakt NRZ sterker en gemakkelijker te gebruiken wanneer u uw gegevens veilig wilt houden.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >PAM4-oogdiagram<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"602\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c1f23795d5d84753b9dee268ead913e6.webp\" alt=\" PAM4 eye diagram\" class=\"wp-image-5811\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c1f23795d5d84753b9dee268ead913e6.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c1f23795d5d84753b9dee268ead913e6-300x151.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c1f23795d5d84753b9dee268ead913e6-1024x514.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c1f23795d5d84753b9dee268ead913e6-768x385.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c1f23795d5d84753b9dee268ead913e6-18x9.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">De <strong>PAM4-oogdiagram<\/strong> is niet hetzelfde als het NRZ-oogdiagram. U ziet vier verschillende niveaus in plaats van slechts twee. Elk niveau staat voor een ander tweetallig bitpatroon. De niveaus liggen dicht bij elkaar, waardoor de oogopeningen kleiner zijn en opgestapeld. Dit maakt het PAM4-signaal gevoeliger voor ruis.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">U kunt zien dat de kleinere oogopeningen bij PAM4 betekenen dat het signaal minder ruis kan verdragen. Het is moeilijker om de timing nauwkeurig bij te houden, omdat de ogen niet zo groot zijn. De opgestapelde ogen kunnen in elkaar overlopen bij te veel ruis, wat tot meer fouten leidt. U hebt speciale hulpmiddelen nodig om fouten te corrigeren en het PAM4-signaal helder te houden.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Als u beide vergelijkt, geeft NRZ een schoner en groter oogdiagram. PAM4 stelt u in staat meer gegevens te verzenden, maar u moet het signaal nauwlettend in de gaten houden en extra ondersteuning gebruiken om fouten laag te houden.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Waar blinken ze? Toepassingsgerichtheid<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>NRZ:<\/strong> Heerst nog steeds onbetwist waar eenvoud, energie-effici\u00ebntie en kosteneffectiviteit van primair belang zijn voor gegevenssnelheden \u2264 25 Gbps per kanaal. Denk aan 10 Gigabit Ethernet (10GbE), 25 Gigabit Ethernet (25GbE) in serververbindingen en oudere systemen. Veel <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>optische transceiver<\/strong><\/a> typen zoals <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26192-10g-sfp.htm\"><strong>SFP+<\/strong><\/a> (10G\/25G) en <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>QSFP28<\/strong><\/a> (4\u00d725G = 100G) maken gebruik van NRZ.<\/p><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>PAM4:<\/strong> De onbetwiste kampioen voor toepassingen met hoge dichtheid en hoge bandbreedte die 50 Gbps per kanaal en hoger vereisen. Het vormt de basis voor:<\/p><ul><li><p style=\"margin: 0px;\">100 Gigabit Ethernet (100GbE \u2013 met 2 kanalen van 50G PAM4)<\/p><\/li><li><p style=\"margin: 0px;\">200 Gigabit Ethernet (200GbE \u2013 4\u00d750G PAM4)<\/p><\/li><li><p style=\"margin: 0px;\">400 Gigabit Ethernet (400GbE \u2013 8\u00d750G PAM4 of 4\u00d7100G PAM4)<\/p><\/li><li><p style=\"margin: 0px;\">800 Gigabit Ethernet (800GbE \u2013 8\u00d7100G PAM4)<\/p><\/li><li><p style=\"margin: 0px;\">AI\/ML-clusters en interconnecties voor High-Performance Computing (HPC).<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Keuze tussen PAM4 en NRZ<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Wanneer u kiest tussen PAM4 en NRZ, moet u een aantal belangrijke factoren overwegen. Elk heeft zijn eigen voordelen voor verschillende toepassingen. U wilt de optie kiezen die het beste aansluit bij uw behoeften op het gebied van snelheid, kosten en mogelijke uitbreiding van uw netwerk.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Hier zijn enkele belangrijke overwegingen:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Snelheidsbehoeften<\/strong>: Als uw netwerk supersnel moet zijn, bijvoorbeeld 400 G of meer, kan PAM4 twee keer zoveel gegevens verzenden op dezelfde ruimte. NRZ is beter geschikt voor langzamere netwerken die minder snelheid nodig hebben.<\/p><\/li><li><p><strong>Signaalqualiteit<\/strong>: NRZ heeft twee spanningsniveaus, waardoor het beter bestand is tegen ruis. U krijgt minder fouten en een duidelijker signaal. PAM4 heeft vier niveaus, dus ruis kan het signaal gemakkelijker verstoren. U hebt speciale hulpmiddelen nodig om fouten bij PAM4 te corrigeren.<\/p><\/li><li><p><strong>Hardware en kosten<\/strong>: NRZ-onderdelen zijn eenvoudig en goedkoper. PAM4 vereist meer onderdelen en speciale chips, waardoor de kosten hoger zijn. Als u geld wilt besparen en de installatie eenvoudig wilt houden, is NRZ een slimme keuze.<\/p><\/li><li><p><strong>Stroomverbruik<\/strong>: NRZ gebruikt minder energie, omdat het geen extra verwerking nodig heeft. PAM4 gebruikt meer energie om het signaal helder te houden.<\/p><\/li><li><p><strong>Afstand<\/strong>: NRZ werkt beter als u gegevens over grote afstanden moet verzenden. PAM4 is het beste geschikt voor korte verbindingen, bijvoorbeeld binnen een datacenter.<\/p><\/li><li><p><strong>Toekomstige uitbreiding<\/strong>: Als u uw netwerk later sneller wilt maken, kan PAM4 hogere snelheden en nieuwe standaarden aan.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">U kunt deze verschillen zien in deze tabel:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Factor<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>NRZ-karakteristieken<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>PAM4-karakteristieken<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Gegevenssnelheid<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1 bit per klokcyclus<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>2 bits per klokcyclus (dubbele bandbreedte)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Signaal-ruisverhouding<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Hoger, minder gevoelig voor ruis<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lager, gevoeliger voor ruis<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/understanding-what-is-bit-error-rate\/\"><strong>Bitfoutenratio (BER)<\/strong><\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lager<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Hoger, vereist foutcorrectie<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Hardwarecomplexiteit<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Eenvoudig, kosteneffectief<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Complex, hogere kosten<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Vermogensverbruik<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lager<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Hoger<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Transmissieafstand<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Langere<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Korter<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Schaalbaarheid<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Geschikt voor huidige behoeften<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Klaar voor toekomstige upgrades<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>\ud83d\udca1 <strong>Tip:<\/strong> Kies NRZ als u iets eenvoudigs en goedkops wilt voor langzamere snelheden of langere verbindingen. Kies PAM4 als u de hoogste snelheden nodig hebt en uw netwerk in de toekomst wilt laten groeien.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 LINK-PP-optische transceivers: Prestaties leveren met NRZ en PAM4<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/99c1c5c4a1e24fe7ab4c7a9236a91630.webp\" alt=\"LINK-PP\" class=\"wp-image-5812\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/99c1c5c4a1e24fe7ab4c7a9236a91630.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/99c1c5c4a1e24fe7ab4c7a9236a91630-300x169.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/99c1c5c4a1e24fe7ab4c7a9236a91630-1024x576.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/99c1c5c4a1e24fe7ab4c7a9236a91630-768x432.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/99c1c5c4a1e24fe7ab4c7a9236a91630-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Het kiezen van de juiste <strong>optische transceiver<\/strong> is essentieel voor netwerkprestaties. <strong>LINK-PP<\/strong> biedt een uitgebreid portfolio dat zowel NRZ als geavanceerde PAM4-modulatie ondersteunt:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Voor NRZ-toepassingen:<\/strong> Betrouwbaar en kosteneffectief <strong>optische transceiver<\/strong> oplossingen zoals onze <strong>LINK-PP SFP-25G-SR <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473141.htm\"><strong>Technologie:<\/strong><\/a> or <strong>LINK-PP QSFP28-100G-SR4<\/strong> <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473115.htm\"><strong>voor multimode of de<\/strong><\/a> leveren robuuste 25 G per lane NRZ-prestaties voor 10 G-, 25 G- en 100 G- (4\u00d725 G) implementaties.<\/p><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>Voor snelle PAM4-toepassingen:<\/strong> Onze geavanceerde PAM4 <strong>optische transceiver<\/strong> modules zijn ontworpen om de uitdagingen op het gebied van signaalintegriteit te overwinnen:<\/p><ul><li><p style=\"margin: 0px;\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/470377.htm\"><strong>LINK-PP LQD-CW400-DR4C:<br><\/strong><\/a> Ideaal voor 400G korte-afstands enkelmodusvezel met behulp van 4x100G PAM4.<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Deze <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>LINK-PP-optische transceivermodules<\/strong><\/a> integreren geavanceerde DSP en sterke FEC om betrouwbare, hoogwaardige connectiviteit te garanderen in veeleisende PAM4-omgevingen, waardoor ze essentieel zijn voor datacenters en AI-infrastructuur van de volgende generatie.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 De toekomst is meerdere niveaus<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Hoewel NRZ nog steeds essentieel is, ligt de toekomst van high-speed netwerken duidelijk op PAM4 en mogelijk zelfs nog complexere modulatieschema\u2019s (zoals PAM8 of PAM16) terwijl we richting 1,6 Terabit Ethernet en verder gaan. Het vermogen van PAM4 om de datarate te verdubbelen zonder de baudrate te verdubbelen, is essentieel om bestaande glasvezelinfrastructuur te benutten. Een succesvolle implementatie van PAM4 hangt af van componenten van hoge kwaliteit en geavanceerd ontwerp \u2013 precies waar innovators zoals LINK-PP uitblinken. <strong>optische transceiver<\/strong> Klaar om uw high-speed netwerk te optimaliseren?.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Het begrijpen van het verschil tussen NRZ en PAM4 is fundamenteel voor het ontwerpen en beheren van moderne, breedbandige netwerken. Of u nu verouderde infrastructuur aanpast of geavanceerde AI-clusters implementeert, het kiezen van de juiste modulatie en de juiste partner is cruciaal.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wat maakt PAM4 beter dan NRZ voor high-speed gegevensoverdracht? <strong>optische transceiver<\/strong> U krijgt een dubbele datarate met PAM4 omdat het twee bits per symbool verzendt. NRZ verzendt slechts \u00e9\u00e9n bit per symbool. PAM4 werkt het beste wanneer u meer snelheid nodig hebt in uw netwerk.<\/p>\n\n\n\n<div><div widgetid=\"3ef779ac451211f099380a58fbc66727\" format=\"embedded\" data-widget-id=\"3ef779ac451211f099380a58fbc66727\" data-mode=\"production.zh\" style=\"display: block;\"><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>FAQ<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Gebruikt PAM4 altijd meer stroom dan NRZ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PAM4 gebruikt meestal meer stroom. U gebruikt extra schakelingen voor foutcorrectie en signaalverwerking. NRZ gebruikt minder stroom omdat het een eenvoudiger ontwerp heeft.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Welke is eenvoudiger te installeren, PAM4 of NRZ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">U vindt NRZ eenvoudiger te installeren. Het maakt gebruik van eenvoudige hardware en vereist minder afstemming. PAM4 vereist meer configuratie en zorgvuldig ontwerp om ruis en fouten te kunnen hanteren.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Kan PAM4 en NRZ in hetzelfde netwerk worden gebruikt?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ja, u kunt beide mengen. U gebruikt NRZ voor oudere of langere verbindingen. U gebruikt PAM4 voor nieuwe, high-speed verbindingen. Dit helpt u bij het stapsgewijs upgraden van uw netwerk.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Welke is beter voor lange afstanden, PAM4 of NRZ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">NRZ werkt beter voor lange afstanden. Het verwerkt ruis goed en houdt het signaal duidelijk. PAM4 is geschikt voor korte tot middellange verbindingen waar u meer snelheid nodig hebt.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Welke is beter voor lange afstanden, PAM4 of NRZ?<br><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">NRZ werkt beter voor lange afstanden. Het verwerkt ruis goed en houdt het signaal duidelijk. PAM4 is geschikt voor korte tot middellange verbindingen waarbij u meer snelheid nodig hebt.<\/p>\n\n\n\n<script src=\"https:\/\/cdn.mylandingpages.co\/widgets\/platform\/platform.widget.js\" async=\"true\"><\/script>","protected":false},"excerpt":{"rendered":"<p>PAM4 versus NRZ: vergelijk gegevenssnelheden, ruisgevoeligheid en effici\u00ebntie om de beste modulatie te kiezen voor uw netwerk- en datacenter-upgrades.<\/p>","protected":false},"author":1,"featured_media":5807,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[26],"class_list":["post-5813","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts\/5813","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/comments?post=5813"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts\/5813\/revisions"}],"predecessor-version":[{"id":11381,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts\/5813\/revisions\/11381"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/media\/5807"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/media?parent=5813"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/categories?post=5813"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/tags?post=5813"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}