{"id":5417,"date":"2025-08-16T00:00:00","date_gmt":"2025-08-16T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/100g-qsfp28-optical-transceivers-selection-guide\/"},"modified":"2026-06-22T09:08:37","modified_gmt":"2026-06-22T09:08:37","slug":"100g-qsfp28-optical-transceivers-selection-guide","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/100g-qsfp28-optical-transceivers-selection-guide","title":{"rendered":"Een complete gids voor het selecteren van 100G QSFP28-optische transceivers: SR4, LR4, CWDM4 en meer"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a117d9c4ef2b4fb1ba276f80e39727aa.webp\" alt=\"100g qsfp28 transceivers\" class=\"wp-image-5415\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a117d9c4ef2b4fb1ba276f80e39727aa.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a117d9c4ef2b4fb1ba276f80e39727aa-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a117d9c4ef2b4fb1ba276f80e39727aa-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a117d9c4ef2b4fb1ba276f80e39727aa-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a117d9c4ef2b4fb1ba276f80e39727aa-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><span class=\"qc-p1-tag\">Wanneer u een <\/span><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><span class=\"qc-p1-tag\"><strong>100G QSFP28-transceiver<\/strong><\/span><\/a><span class=\"qc-p1-tag\">, kiest, denk dan na over wat uw netwerk nodig heeft. Controleer belangrijke zaken zoals compatibiliteit, de afstand die gegevens moeten afleggen, vezeltype, connectorstype, waar u het gaat gebruiken en of het in de toekomst nog geschikt is. Het kiezen van QSFP28-optische transceivers die passen bij uw systeem helpt uw netwerk goed te laten functioneren en beschermt uw investering. <\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">Deze definitieve gids doorbreekt de verwarring en onderzoekt alle belangrijke 100G-QSFP28-opties \u2013 van <\/span><span class=\"qc-p1-tag\"><strong>SR4<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\"> en <\/span><span class=\"qc-p1-tag\"><strong>LR4<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\"> tot <\/span><span class=\"qc-p1-tag\"><strong>CWDM4<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">, <\/span><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/100g-single-lambda-transceivers-benefits-upgrades-performance\/\"><span class=\"qc-p1-tag\"><strong>Enkele lambda<\/strong><\/span><\/a><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">, en verder \u2013 om u te helpen een weloverwogen keuze te maken voor uw <\/span><span class=\"qc-p1-tag\"><strong>high-speed connectiviteit<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\"> behoeften.<\/span><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Wat is een QSFP28-optische module?<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">De <strong>QSFP28 (Kwadrupel kleine vormfactor-insteekbare module 28)<\/strong> is de industrie-standaard vormfactor voor 100 Gigabit Ethernet (100GbE) en hoge-snelheidsdatacenterinterconnects. Het bevat vier kanalen met een snelheid van 25 Gbps of \u00e9\u00e9n hoog-snelheidskanaal in een compacte, hot-pluggable module.<\/span><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Ontwar uw 100G-QSFP28-opties: een technische uitleg<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p style=\"margin: 0px 0px 4px;\"><strong>100G-SR4 (kort bereik)<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>VCSEL-laser.<\/strong> Parallelle multimodevezel (MMF) met gebruik van 4 kanalen (4\u00d725G NRZ).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Toepassing:<\/strong> Tot 70 m (OM3 MMF), 100 m (OM4 MMF) of 150 m (OM5 MMF).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Bereik:<\/strong> Vereist <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/mpo-connectors-differences-8-12-16-24-fiber-comparison\/\"><strong>MTP\/MPO-12<\/strong><\/a> connector. Gebruikt 4 vezels voor Tx en 4 vezels voor Rx <strong>(totaal 8 vezels)<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Geschikt voor:<\/strong> <strong>Top-of-rack-switching<\/strong>, <strong>intra-datacenterverbindingen<\/strong>, server-naar-leaf-connectiviteit binnen racks of rijen met behulp van <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/om1-om2-om3-om4-om5-multimode-fiber-guide\/\"><strong>multimodevezelkabels<\/strong><\/a>. Kosteneffectief voor korte afstanden.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Voorbeeldmodel:<\/strong> QSFP28-100G-SR4 <strong>LINK-PP <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473115.htm\"><strong>voor multimode of de<\/strong><\/a> (ondersteunt OM3\/OM4\/OM5)<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>100G-PSM4 (parallelle single-mode, 4-kanaals)<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>VCSEL-laser.<\/strong> Parallelle single-modevezel <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/what-is-single-mode-fiber-and-how-does-it-work\/\"><strong>(SMF)<\/strong><\/a> met gebruik van 4 kanalen (4\u00d725G NRZ).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Toepassing:<\/strong> Meestal tot 500 m over standaard SMF.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Bereik:<\/strong> Vereist <strong>MTP\/MPO-12<\/strong> connector. Gebruikt 4 vezels voor Tx en 4 vezels voor Rx <strong>(totaal 8 vezels)<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Geschikt voor:<\/strong> Langere intra-datacenter- of campusverbindingen dan SR4 mogelijk maakt, waar SMF-infrastructuur al is ge\u00efmplementeerd of gewenst is voor toekomstbestendigheid. Minder gebruikelijk dan CWDM4\/LR4 voor langere SMF-afstanden.<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>100G-LR4 \/ ER4 \/ ZR4 (lang\/bereik uitgebreid\/bereik extra uitgebreid)<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>VCSEL-laser.<\/strong> Coarse Wavelength Division Multiplexing <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/what-is-cwdm-understanding-coarse-wavelength-division-multiplexing\/\"><strong>(CWDM)<\/strong><\/a> over duplex SMF. Combineert 4 golflengten (ongeveer 1295, 1300, 1304, 1309 nm) op 2 vezels (1 Tx, 1 Rx). LR4 is standaard, ER4 biedt uitgebreid bereik, ZR4 biedt het langste bereik.<\/p><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>Toepassing:<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>LR4:<\/strong> Tot 10 km<\/p><\/li><li><p style=\"margin: 0px;\"><strong>ER4:<\/strong> Tot 40 km<\/p><\/li><li><p style=\"margin: 0px;\"><strong>ZR4:<\/strong> Tot 80 km+<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px;\"><strong>Bereik:<\/strong> Gebruikt standaard <strong>duplex LC<\/strong> connectors. Vereist slechts 2 vezels.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Geschikt voor:<\/strong> <strong>Datacenterinterconnectie (DCI)<br><\/strong>, <strong>metro-netwerken<\/strong>, gebouw-naar-gebouw-verbindingen, aggregatielagen. Essentieel voor <strong>langafstandsvezeloptische transmissie<br><\/strong>. ER4\/ZR4 zijn bedoeld voor gespecialiseerde, langere verbindingen.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Voorbeeldmodel:<\/strong> LINK-PP QSFP28-100G-LR4 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472118.htm\"><strong>LQ-LW100-LR4C<\/strong><\/a> (10 km), LINK-PP QSFP28-100G-ER4 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472708.htm\"><strong>LQ-LW100-ER4C<\/strong><\/a> (40 km), LINK-PP QSFP28-100G-ZR4 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482513.htm\"><strong>LQ-LW100-ZR4C<\/strong><\/a> (80 km)<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>100G-CWDM4<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>VCSEL-laser.<\/strong> Vergelijkbaar met LR4, gebruikt <strong>CWDM<\/strong> over duplex SMF maar met licht verschillende golflengten (1271, 1291, 1311, 1331 nm), geoptimaliseerd voor lagere kosten en stroomverbruik.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Toepassing:<\/strong> Tot 2 km. Gedefinieerd door de CWDM4 MSA.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Bereik:<\/strong> Gebruikt standaard <strong>duplex LC<\/strong> connectors. Vereist slechts 2 vezels.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Geschikt voor:<\/strong> Kosteneffectieve oplossing voor <strong>intra-datacenter SMF-koppelingen<\/strong> tot 2 km (bijv. tussen gebouwen op een campus, over grotere datahallen). Een populaire alternatief voor PSM4 voor duplex SMF.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Voorbeeldmodel:<\/strong> LINK-PP QSFP-100G-CWDM4 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472577.htm\"><strong>LQ-CW100-FR4C<\/strong><\/a> (2 km)<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>100G Single Lambda (bijv. FR1\/LR1\/ER1\/DR1\/ZR1)<\/strong><\/p><ul><li><p style=\"margin: 0px 0px 4px;\"><strong>VCSEL-laser.<\/strong> Gebruikt een <em>enkele<\/em> hoogwaardige golflengte (bijv. 53,125 Gbaud <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\"><strong>PAM4-modulatie<\/strong><\/a>) over duplex SMF. Omvat diverse bereiken:<\/p><ul><li><p style=\"margin: 0px;\"><strong>FR1 (2 km) \/ LR1 (10 km):<\/strong> Algemene standaarden.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>DR1 (500 m):<\/strong> Gebruikt vaak de golflengte van 1310 nm.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>ER1 (40 km) \/ ZR1 (80 km+)<\/strong> Langere bereikvarianten.<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px;\"><strong>Toepassing:<\/strong> Varieert (500 m, 2 km, 10 km, 40 km, 80 km+).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Bereik:<\/strong> Gebruikt standaard <strong>duplex LC<\/strong> connectors. Vereist slechts 2 vezels.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Geschikt voor:<\/strong> <strong>Toekomstige datacenterarchitecturen<\/strong>, vereenvoudiging van de glasvezelinstallatie (slechts 2 vezels nodig per koppeling), voorbereiding op 400G\/800G (die sterk afhankelijk zijn van PAM4). Biedt <strong>hogere poortdichtheid<\/strong> potentieel. Belangrijk voor <strong>toekomstbestendig netwerkontwerp<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Voorbeeldmodel:<\/strong> LINK-PP QSFP-100G-DR1 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482616.htm\"><strong>LQ-SM31100-DR1C<\/strong><\/a> (10 km).<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>100G-SWDM4 (Short Wavelength Division Multiplexing)<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>VCSEL-laser.<\/strong> Gebruikt wavelength division multiplexing over MMF. Combineert 4 <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/overview-of-vcsel\/\"><strong>Glasvezeltype:<\/strong><\/a>-gebaseerde golflengten (850, 880, 910, 940 nm) op 2 vezels (1 Tx, 1 Rx).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Toepassing:<\/strong> Tot 75 m (OM3), 100 m (OM4), 150 m (OM5).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Bereik:<\/strong> Gebruikt standaard <strong>duplex LC<\/strong> connectors. Vereist slechts 2 vezels.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Geschikt voor:<\/strong> Benut bestaande <strong>LC-duplex MMF-bedrading<\/strong> voor 100G, waardoor upgrades naar MTP\/MPO overbodig worden. Ideaal voor <strong>glasvezelmigratiestrategie\u00ebn<\/strong> waar duplex MMF veelvoorkomt.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Voorbeeldmodel:<\/strong> LINK-PP QSFP-100G-SWDM4 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473140.htm\"><strong>LQ-SW100-SR4C<\/strong><\/a> (100 m)<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>100G Bidirectioneel (BiDi)<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>VCSEL-laser.<\/strong> Gebruikt een <em>enkele<\/em> enkele vezel. Bereikt volledige duplex 100G door zowel te verzenden als te ontvangen op twee verschillende golflengten (bijv. Tx 1330 nm \/ Rx 1270 nm) over dezelfde vezel.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Toepassing:<\/strong> Meestal tot 10 km of 20 km over SMF.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Bereik:<\/strong> Gebruikt een <strong>enkele simplex LC<\/strong> connector. Vereist slechts 1 vezel per koppeling.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Geschikt voor:<\/strong> <strong>Maximalisering van bestaande glasvezelinfrastructuur<\/strong> (verdubbeling van capaciteit), <strong>situaties met glasvezeltekort<\/strong>, kosteneffectieve upgrades waar glasvezel schaars is. Cruciaal voor <strong>optimalisatie van vezelcapaciteit<\/strong>.<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>100G\/112G Dual-Rate Modules<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>VCSEL-laser.<\/strong> Hermetische TOSA met <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/what-is-lwdm-and-why-important-for-lans\/\"><strong>LAN-WDM<\/strong><\/a> -gebaseerde DFB-ondersteuning voor datarates van 25,78 G\/s en 27,95 G\/s.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Toepassing:<\/strong> Meestal tot 10 km over SMF<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Bereik:<\/strong> Gebruikt standaard <strong>duplex LC<\/strong> connectors. Vereist slechts 2 vezels.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Geschikt voor:<\/strong> 100GBASE-LR4 Ethernet-koppelingen, InfiniBand QDR- en DDR-interconnects, clientzijde 100G telecomverbindingen.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Voorbeeldmodel:<\/strong> LINK-PP <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/488452.htm\"><strong>LQ-LW112-LR4C<\/strong><\/a>.<\/p><\/li><\/ul><\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5d7fcaaefde14dedb89f4bc7ecd50005.webp\" alt=\"100g qsfp28 module\" class=\"wp-image-5416\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5d7fcaaefde14dedb89f4bc7ecd50005.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5d7fcaaefde14dedb89f4bc7ecd50005-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5d7fcaaefde14dedb89f4bc7ecd50005-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5d7fcaaefde14dedb89f4bc7ecd50005-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5d7fcaaefde14dedb89f4bc7ecd50005-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>100G QSFP28-transceiververgelijking in \u00e9\u00e9n oogopslag<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Moduletype<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Technologie<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Golflengte<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Vezeltype &amp; connector<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Maximale bereikafstand<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Belangrijkste toepassing<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G-SR4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4\u00d725G NRZ (MMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>850nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>MMF \/ MPO-12<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>70 m \u2013 150 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Korte intra-DC, ToR-switching<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G-PSM4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4\u00d725G NRZ (SMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1310 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SMF \/ MPO-12<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>500 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Medium Intra-DC\/Campus (Parallel)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G-LR4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4\u00d725G LWDM<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~1295\u20131310 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SMF \/ LC-duplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>DCI, metro, gebouwverbindingen<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G-ER4\/ZR4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4\u00d725G LWDM<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~1295\u20131310 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SMF \/ LC-duplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>40 km \/ 80 km+<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lange-afstands-DCI, metro<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G-CWDM4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4\u00d725G CWDM<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1271\u20131331 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SMF \/ LC-duplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>2 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Kosteneffectief intra-DC SMF<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G enkel-lambda<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1\u00d7100G PAM4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1310 nm (bijv.)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SMF \/ LC-duplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>500 m \u2013 80 km+<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Volgende generatie DC, vereenvoudigde vezel<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G-SWDM4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4\u00d725G WDM (MMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>850\u2013940 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>MMF \/ LC-duplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>75 m \u2013 150 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Gebruik bestaande duplex-MMF-kabels<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G BiDi<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1\u00d7100G BiDi<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Bijv. Tx1330\/Rx1270<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SMF \/ Simplex LC<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10 km \/ 20 km \/ 40 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Vezeluitputting, enkele vezel<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Dual-rate (bijv. LR4)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>100G \/ 112G <\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>LAN-WDM, 1295\u20131309 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SMF \/ Duplex LC<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Afhankelijk van de modus<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Migratie, flexibiliteit bij aggregatie<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Het juiste LINK-PP QSFP28-module kiezen: belangrijke overwegingen<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Vereiste afstand:<\/strong> Dit is de primaire drijfveer (SR4 voor &lt;150 m MMF, CWDM4 voor 2 km SMF, LR4 voor 10 km, enz.).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Glasvezelinfrastructuur:<\/strong> Wat is er al ge\u00efnstalleerd (MMF versus SMF, MPO versus LC-duplex\/simplex)? SWDM4 gebruikt duplex-MMF, BiDi gebruikt simplex-SMF.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Kosten:<\/strong> SR4 en CWDM4 zijn over het algemeen goedkoper dan LR4\/ER4 of Single Lambda. BiDi kan fiberkosten besparen.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Stroomverbruik:<\/strong> CWDM4 en nieuwere PAM4-modules <strong>(Enkele Lambda)<\/strong> hebben vaak een lagere stroomverbruik dan LR4.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Toekomstbestendigheid:<\/strong> Single Lambda-modules passen bij 400G\/800G-technologie\u00ebn die gebruikmaken van <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\"><strong>PAM4<\/strong><\/a>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Dual-Ratebehoeften:<\/strong> Vereist u nu of in de toekomst 4\u00d725G- of 4\u00d728G-connectiviteit?<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fibercapaciteit:<\/strong> Is fiber schaars? BiDi-modules verdubbelen effectief uw fibercapaciteit.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Optimaliseer uw 100G-netwerk met vertrouwen<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Het selecteren van de optimale <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>100G QSFP28-transceiver<\/strong><\/a> is fundamenteel voor het bereiken van <strong>high-performance netwerken<\/strong>, <strong>schaalbare datacenterarchitectuur<\/strong>, en <strong>maximalisering van ROI<\/strong> op uw <strong>glasvezelinfrastructuur<\/strong>. Door de sterke punten van elke technologie te begrijpen \u2013 van de kosteneffectieve <strong>100G-SR4<\/strong> voor racks tot de lange-afstandsfunctionaliteit van <strong>100G-LR4\/ER4<\/strong>, de fiberbesparende magie van <strong>100G-BiDi<\/strong>, of de toekomstbestendige <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/100g-single-lambda-transceivers-benefits-upgrades-performance\/\"><strong>100G Single Lambda (PAM4)-modules<\/strong><\/a> \u2013 kunt u strategische beslissingen nemen die aansluiten bij uw specifieke <strong>netwerkontwerpvereisten<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Klaar om high-performance 100G-connectiviteit te implementeren?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>LINK-PP biedt een uitgebreid portfolio van betrouwbare, <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/multi-source-agreements-optical-transceivers\/\"><strong>MSA-conforme<br><\/strong><\/a><strong> 100G QSFP28-optische modules<\/strong>, inclusief alle hier besproken typen: <strong>SR4<\/strong>, <strong>LR4<\/strong>, <strong>ER4<br><\/strong>, <strong>CWDM4<\/strong>, <strong>Enkele Lambda (DR1\/FR1)<\/strong>, <strong>SWDM4<\/strong>, <strong>BiDi<\/strong>, en <strong>Dual-Rate<\/strong> oplossingen. Onze transceivers worden grondig getest op <strong>interoperabiliteit<\/strong> en prestaties, waardoor naadloze integratie in uw <strong>Cisco<\/strong>, <strong>Arista<\/strong>, <strong>Juniper<\/strong>, <strong>Mellanox<\/strong>, of <strong>Huawei<\/strong> switches en routers wordt gegarandeerd.<\/p>\n\n\n\n<div class=\"alignnone qc-cover-wrapper has-custom-content-position is-position-center\" elementtype=\"div\" useimagebackground=\"false\" imgbg=\"\" imgbgpositionleft=\"50\" imgbgpositiontop=\"50\" overlay=\"#165DFF\" overlayopacity=\"0.8\" contentposition=\"center\" alt=\"\" parallax=\"false\" style=\"border-radius: 12px; padding-left: var(--qc-preset--spacing--60); padding-right: var(--qc-preset--spacing--60); padding-top: var(--qc-preset--spacing--50); padding-bottom: var(--qc-preset--spacing--50); background-color: rgb(245, 245, 245); height: auto;\"><div class=\"qc-cover-wrapper__inner-container\"><div style=\"flex-wrap: wrap; justify-content: center; display: flex;\"><div colmd=\"10\" class=\"col col-md-10\"><p style=\"text-align: center;\"><span class=\"qc-h1-tag\" style=\"color: var(--qc-color5);\">LINK-PP-oplossingen<\/span><\/p><p style=\"text-align: center;\"><strong>Verken vandaag nog het volledige assortiment 100G QSFP28-modules!<\/strong><\/p><div class=\"qc-buttons-wrapper\"><div justification=\"center\" class=\"qc-buttons-container is-horizontal is-content-justification-center\" style=\"margin-top: var(--qc-preset--spacing--0); margin-bottom: var(--qc-preset--spacing--0); gap: var(--qc-preset--spacing--40);\"><div link=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\" opennewtab=\"true\" width=\"\" outline=\"false\" class=\"qc-button-wrapper\" style=\"background-color: var(--qc-color1);\"><a class=\"qc-button-container\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\" target=\"_blank\"><span style=\"color: rgb(191, 61, 55);\"><strong>\ud83d\udd0dNu bronnen<\/strong><\/span><\/a><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Zie ook<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/100g-optical-transceiver-form-factors-guide\/\">Vormfactoren van 100G-optische transceivermodules: CFP, CFP2, CFP4, CXP, QSFP28<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/100g-single-lambda-transceivers-benefits-upgrades-performance\/\">Wat u moet weten over 100G Single Lambda-optica<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/100g-single-lambda-vs-4-channel-optical-modules-comparison\/\">Vergelijking van 100G single-lambda- en 4-kanaals optische modules: Belangrijke verschillen<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/psm4-vs-cwdm4-which-optical-transceiver-for-your-network\/\">PSM4 versus CWDM4-transceiver: belangrijkste verschil uitgelegd<\/a><\/p>\n\n\n\n<script>const link1 = document.createElement('link');link1.rel = 'stylesheet';link1.type = 'text\/css';link1.href = 'https:\/\/statics.quickcreator.io\/static\/theme\/css\/qcb-theme-additional.css';const link2 = document.createElement('link');link2.rel = 'stylesheet';link2.type = 'text\/css';link2.href = 'https:\/\/statics.quickcreator.io\/static\/aaapycm22qmuab44\/theme\/css\/qcb-main-theme.css';document.head.appendChild(link1);document.head.appendChild(link2);<\/script>","protected":false},"excerpt":{"rendered":"<p>Kies de beste 100G QSFP28-optische transceiver voor uw netwerk door compatibiliteit, afstand, vezeltype en toekomstbestendige opties te vergelijken.<\/p>","protected":false},"author":1,"featured_media":5415,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13],"class_list":["post-5417","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts\/5417","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/comments?post=5417"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts\/5417\/revisions"}],"predecessor-version":[{"id":11392,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts\/5417\/revisions\/11392"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/media\/5415"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/media?parent=5417"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/categories?post=5417"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/tags?post=5417"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}