{"id":5407,"date":"2025-08-18T00:00:00","date_gmt":"2025-08-18T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/qsfp28-100g-psm4-transceivers-for-data-centers\/"},"modified":"2026-06-22T08:21:27","modified_gmt":"2026-06-22T08:21:27","slug":"qsfp28-100g-psm4-transceivers-for-data-centers","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/qsfp28-100g-psm4-transceivers-for-data-centers","title":{"rendered":"Ontsluit high-density 100G-connectiviteit: uw gids voor de 100G PSM4-optische module"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e8c59990135f47488a1f089f23f62ace.webp\" alt=\"QSFP28 100G PSM4 Transceivers\" class=\"wp-image-5405\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e8c59990135f47488a1f089f23f62ace.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e8c59990135f47488a1f089f23f62ace-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e8c59990135f47488a1f089f23f62ace-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e8c59990135f47488a1f089f23f62ace-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e8c59990135f47488a1f089f23f62ace-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">De onstuitbare opkomst van cloudcomputing, AI en hyperscale-toepassingen vraagt om steeds snellere, dichtere en kosteneffectievere datacenterinterconnects (DCI). Hier komt de <\/span><span class=\"qc-p1-tag\"><strong>100G PSM4 (Parallel Single-Mode 4-lane)<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\"> optische module \u2013 een cruciale werkpaard die effici\u00ebnte 100 Gigabit Ethernet (100GbE)-verbindingen aandrijft. Deze gids gaat diep in op wat PSM4 tot een essenti\u00eble oplossing maakt voor moderne netwerkinfrastructuur.<\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udca1 Kennis van PSM4-technologie helpt netwerkengineers de beste keuze te maken voor sterke en groeiende prestaties.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\ud83d\udcdd Wat is een 100G PSM4-optische module?<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Een 100G PSM4-transceiver is een uitwisselbare optische module ontworpen voor 1<strong>00G Ethernet<\/strong> -transmissie over <strong>single-modevezel <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/what-is-single-mode-fiber-and-how-does-it-work\/\"><strong>(SMF)<\/strong><\/a>. Deze maakt gebruik van vier onafhankelijke optische kanalen, elk met een snelheid van 25 Gbps (met behulp van <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/understanding-non-return-to-zero-in-digital-communication\/\"><strong>NRZ-modulatie<\/strong><\/a>) bij de <strong>Golflengte van 1310 nm<\/strong>. In tegenstelling tot <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/100g-cwdm4-transceiver-efficient-2km-links\/\"><strong>100G<\/strong> <strong>CWDM4-transceivers<\/strong><\/a>, die golflengten multiplexen op \u00e9\u00e9n vezelpaar, vereist PSM4 <strong>acht vezels<\/strong> (4 Tx, 4 Rx) \u2013 een gewijd paar per kanaal. Deze aanpak met \u201cparallelle optica\u201d biedt duidelijke voordelen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\ud83d\udcdd Belangrijkste voordelen van 100G PSM4-technologie<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Kostenbesparingen:<\/strong> \ud83d\udcb0 PSM4 maakt gebruik van goedkoper optisch materiaal vergeleken met golflengtemultiplexoplossingen zoals <strong>CWDM4<\/strong>. De eenvoudigere optica vertaalt zich naar een <strong>goedkopere 100G-transceiver<\/strong>, wat vooral belangrijk is bij grootschalige implementaties.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Lage latentie:<\/strong> \u26a1 Het directe parallelle transmissiepad minimaliseert de complexiteit van signaalverwerking, wat resulteert in <strong>ultralage latentie<\/strong> \u2013 cruciaal voor high-frequency trading, AI-clusters en financi\u00eble toepassingen.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Hoge dichtheid en schaalbaarheid:<\/strong> \u2b50 PSM4-modules zijn doorgaans <strong>QSFP28-formfactor<\/strong>, waardoor een hoge poortdichtheid mogelijk is op switches en routers. Ze zijn ideaal voor <strong>leaf-spine-architecturen<\/strong> en <strong>top-of-rack (ToR)<\/strong> tot <strong>aggregatie\/distributie<\/strong> -switchverbindingen binnen een datacenterhal.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Betrouwbare SMF-prestaties:<\/strong> \ud83d\ude80 Het gebruik van bewezen single-mode vezel garandeert <strong>een langere bereikmogelijkheid<\/strong> (tot 500 m, vaak 2 km met kwalitatief hoogwaardige modules zoals die van LINK-PP) en <strong>superieure prestaties<\/strong> vergeleken met multimode-oplossingen (zoals SR4) over vergelijkbare afstanden.<\/p><\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\ud83d\udcdd Ideale toepassingen voor 100G PSM4-modules<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Datacenterinterconnect (DCI):<\/strong> Binnen \u00e9\u00e9n datacentergebouw of campus (tot 500 m\u20132 km).<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>High-Performance Computing <\/strong><a href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/what-is-hpc-high-performance-computing\/\" target=\"_blank\" rel=\"\"><strong>(HPC)<\/strong><\/a><strong> Clusters:<\/strong> Waar lage latentie en hoge bandbreedte onmisbaar zijn.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Enterprise-netwerkcore\/aggregatie:<\/strong> Upgraden van backbone-koppelingen voor bandbreedte-intensieve toepassingen.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Infrastructuur van cloudaanbieders:<\/strong> Verbinden van servers, opslag en switches in grootschalige cloudomgevingen.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Financi\u00eble netwerken:<\/strong> Ondersteunen van handelsplatforms met lage latentie.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\ud83d\udcdd PSM4 vs. CWDM4: De juiste 100G SMF-oplossing kiezen<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Eigenschap<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>100G PSM4<br><\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>100G CWDM4<br><\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Technologie<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Parallelle optica (4 kanalen)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/wdm-optical-transceiver-module-applications\/\"><strong>WDM<\/strong><\/a> (4 golflengten op 1 paar)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Aantal vezels<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>8 vezels<\/strong> (4 Tx, 4 Rx)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>2 vezels<\/strong> (1 Tx, 1 Rx)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Bereik<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Tot 500 m (standaard), <strong>2 km+<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Tot 2 km<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Kosten<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Over het algemeen lager<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Hoger<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Latentie<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Ultra-laag<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Laag<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Complexiteit<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lager (optica)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Hoger (WDM-mux\/demux vereist)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Beste voor<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Hoogdichtheid, kostengevoelige intra-DC-koppelingen &lt; 2 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Koppelingen waar vezel schaars is, tot 2 km<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\ud83d\udcdd Waarom LINK-PP 100G PSM4-optische modules kiezen?<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"608\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39cdcc49922c4d8ebdd258250cf678e9-1024x608.webp\" alt=\"LINK-PP 100G PSM4 Solutions\" class=\"wp-image-5406\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39cdcc49922c4d8ebdd258250cf678e9-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39cdcc49922c4d8ebdd258250cf678e9-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39cdcc49922c4d8ebdd258250cf678e9-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39cdcc49922c4d8ebdd258250cf678e9-18x12.webp 18w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39cdcc49922c4d8ebdd258250cf678e9.webp 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Wanneer betrouwbaarheid, prestaties en waarde van essentieel belang zijn, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.link-pp.com\/\"><strong>LINK-PP<\/strong><\/a> onderscheidt het zich. Onze <strong>100G PSM4 QSFP28-transceivers<\/strong> zijn ontworpen voor uitmuntendheid:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Gegarandeerde compatibiliteit:<\/strong> Zorgvuldig getest voor naadloze werking met belangrijke OEM-switches (Cisco, Juniper, Arista, enz.). Vermijd de risico\u2019s van generieke modules.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Uitstekende kwaliteit &amp; betrouwbaarheid:<\/strong> Vervaardigd volgens de hoogste normen, wat een lage <strong>bitfoutpercentages <\/strong><a href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/understanding-what-is-bit-error-rate\/\" target=\"_self\"><strong>(BER)<\/strong><\/a> en lange levensduur garandeert \u2013 ideaal voor <strong>missie-kritieke datacenterkoppelingen<\/strong>.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Uitgebreid bereik:<\/strong> Onze <strong>LINK-PP <\/strong><a href=\"https:\/\/www.l-p.com\/products\/488422.htm\" target=\"_blank\" rel=\"\"><strong>LQ-M31100-FR4C<\/strong><\/a> model bereikt betrouwbaar <strong>tot 2 km<\/strong> over enkelmodusvezel, waardoor de implementatie flexibeler wordt.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Kostenbesparingen:<\/strong> Ervaar aanzienlijke <strong>CAPEX-verlaging<\/strong> zonder in te boeten op prestaties of stabiliteit.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Uitgebreide garantie en ondersteuning:<\/strong> Ondersteund door toonaangevende industrieondersteuning en garantie.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ontgrendel uw 100G-potentie met LINK-PP!<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Optimaliseer uw datacenterfabric met hoogwaardige, kosteneffectieve <strong>100G-connectiviteits<\/strong>. Of u nu nieuwe infrastructuur implementeert of bestaande koppelingen upgradet, <strong>LINK-PP\u2019s 100G PSM4-transceivers<\/strong> bieden de betrouwbare, lage-latentiebasis die u nodig hebt.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Klaar om LINK-PP 100G PSM4-modules te verkennen?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u27a1\ufe0f <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/488422.htm\"><strong>LQ-M31100-FR4C (2 km)<\/strong><\/a><br>\u27a1\ufe0f <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/488423.htm\"><strong>LQ-M31100-LR4C (10 km)<\/strong><\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\ud83d\udcdd Veelgestelde vragen<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Wat betekent PSM4?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PSM4 staat voor \u201cParallel Single Mode 4-lane\u201d. De transceiver gebruikt vier vezels om gegevens te verzenden. Het gebruikt ook vier vezels om gegevens te ontvangen. Elk kanaal verplaatst 25 Gbps.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Kan QSFP28 100G PSM4 werken met bestaande enkelmodusvezel?<\/h3>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Ja, QSFP28 100G PSM4-transceivers werken met standaard enkelmodusvezel (OS2). Veel datacenters gebruiken al dit vezeltype. Dit maakt upgrades eenvoudig en bespaart geld.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">Hoe bewaakt u de gezondheid van een PSM4-transceiver?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Netwerkbeheerders gebruiken Digitale Diagnostische Bewaking, ook wel DDM genoemd. DDM toont onder andere temperatuur, spanning en signaalsterkte. Dit helpt hen problemen vroegtijdig te detecteren en op te lossen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Welke connector gebruikt de QSFP28 100G PSM4?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>De transceiver gebruikt een MPO\/MTP-12-connector.<\/p><\/li>\n\n\n\n<li><p>Deze connector bevat twaalf vezels in \u00e9\u00e9n rij.<\/p><\/li>\n\n\n\n<li><p>Acht vezels verzenden gegevens; vier zijn niet in gebruik.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Is de QSFP28 100G PSM4 hot-pluggable?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ja, u kunt de transceiver inbrengen of verwijderen zonder het apparaat uit te schakelen. Dit zorgt ervoor dat het netwerk blijft functioneren tijdens upgrades of reparaties.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Zie ook<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/100g-qsfp28-optical-transceivers-selection-guide\/\">Verken 100G QSFP28-optische transceivers: SR4, LR4, CWDM4, PSM4 en meer<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/psm4-vs-cwdm4-which-optical-transceiver-for-your-network\/\">PSM4 versus CWDM4: wat zijn de verschillen?<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/100g-single-lambda-vs-4-channel-optical-modules-comparison\/\">100G Single Lambda versus 4-golflengte-optische modules: belangrijke verschillen<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/100g-optical-transceiver-form-factors-guide\/\">Vormfactoren van 100G-optische transceivers: QSFP28, CFP, CFP2, CFP4?<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>QSFP28 100G PSM4-transceivers bieden hoge snelheid en kosteneffectieve 100G Ethernet over enkelmodus-glasvezel, ideaal voor datacenters en bedrijfsnetwerken.<\/p>","protected":false},"author":1,"featured_media":5405,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13],"class_list":["post-5407","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts\/5407","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/comments?post=5407"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts\/5407\/revisions"}],"predecessor-version":[{"id":11245,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts\/5407\/revisions\/11245"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/media\/5405"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/media?parent=5407"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/categories?post=5407"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/tags?post=5407"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}