{"id":4708,"date":"2025-10-15T11:12:00","date_gmt":"2025-10-15T11:12:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/rdma-over-converged-ethernet-fast-low-latency-data-transfer\/"},"modified":"2026-06-22T06:19:58","modified_gmt":"2026-06-22T06:19:58","slug":"rdma-over-converged-ethernet-fast-low-latency-data-transfer","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/rdma-over-converged-ethernet-fast-low-latency-data-transfer","title":{"rendered":"Ontketen uw netwerk: Een diepe duik in RoCE (RDMA over Converged Ethernet)"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1408\" height=\"768\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/df1f7807f7af4013a163b0d1cbcc4e1f.jpg\" alt=\"What is RDMA over Converged Ethernet\" class=\"wp-image-4706\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/df1f7807f7af4013a163b0d1cbcc4e1f.jpg 1408w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/df1f7807f7af4013a163b0d1cbcc4e1f-300x164.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/df1f7807f7af4013a163b0d1cbcc4e1f-1024x559.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/df1f7807f7af4013a163b0d1cbcc4e1f-768x419.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/df1f7807f7af4013a163b0d1cbcc4e1f-18x10.jpg 18w\" sizes=\"(max-width: 1408px) 100vw, 1408px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">In de huidige data-gedreven wereld, waar microseconden tellen en applicatieprestaties centraal staan, stuiten traditionele netwerkprotocollen op hun grenzen. Stap in <strong>RoCE (RDMA over Converged Ethernet)<\/strong>, een baanbrekende technologie die verbluffende snelheid en ultra-lage latentie biedt voor moderne datacenters. In dit artikel wordt RoCE ontrafeld, worden de twee versies ervan besproken en wordt uitgelegd hoe deze technologie <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/what-is-hpc-high-performance-computing\/\"><strong>high-performance computing (HPC)<\/strong><\/a>, <strong>AI\/ML-workloads<\/strong>, <strong>en cloudinfrastructuur<\/strong>. revolutioneert. We gaan ook dieper in op een cruciale hardwarecomponent: de optische transceiver, en wijzen erop hoe een oplossing als de <strong>LINK-PP 800G QSFP-DD SR8<\/strong> is ontworpen om aan deze extreme eisen te voldoen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Wat is RoCE? Het verminderen van netwerkoverhead<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">In essentie staat RoCE voor <strong>RDMA over Converged Ethernet<\/strong>. Om het te begrijpen, moeten we eerst RDMA uitleggen.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/remote-direct-memory-access-rdma-data-transfer-speed-latency\/\"><strong>RDMA (Remote Direct Memory Access)<\/strong><\/a><strong>:<\/strong> Dit is een technologie waarmee een computer toegang heeft tot geheugen op een externe machine <strong>zonder betrokkenheid van de CPU of het besturingssysteem<\/strong>. Deze \u201ckernel bypass\u201d is de geheime ingredi\u00ebnt die aanzienlijke latentie en CPU-overhead elimineert.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Over Converged Ethernet:<\/strong> RoCE neemt deze krachtige RDMA-functionaliteit en voert deze uit op standaard Ethernet-netwerken. Dit is een groot voordeel, omdat organisaties zo hun bestaande Ethernet-infrastructuur kunnen blijven gebruiken in plaats van te moeten investeren in gespecialiseerde, dure netwerken zoals InfiniBand.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Het belangrijkste voordeel? <strong>Zeer lage latentie en hoge doorvoer.<\/strong> Door de TCP\/IP-stack en de externe CPU te omzeilen, wordt gegevensoverdracht een directe geheugen-naar-geheugenoperatie, waardoor waardevolle CPU-cycli vrijkomen voor de eigenlijke applicatie.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 RoCE v1 versus RoCE v2: wat is het verschil?<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Niet alle <strong>RoCE<\/strong> is niet gelijk. Er zijn twee hoofdversies, en het begrijpen van het verschil is cruciaal voor netwerkontwerp.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Eigenschap<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>RoCE v1 (RoCE)<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>RoCE v2 (Routerbare RoCE)<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Ethernet-type<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Alleen Ethernet-laag 2<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>IP-gebaseerd (UDP), laag 3<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u2013 \u00c9\u00e9n subnet<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Beperkt tot \u00e9\u00e9n laag-2-broadcastdomein (bijv. \u00e9\u00e9n datacenterrack).<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Routbaar over laag-3-IP-netwerken (hele datacenter of tussen datacenters).<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Flexibiliteit<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Laag<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Hoog<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Toepassing<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Gesloten, high-performanceclusters.<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Schaalbare, cloud-native omgevingen.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><span class=\"qc-p1-tag\"><strong>Waarom is dit belangrijk?<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(15, 17, 21);\"> Voor de meeste moderne, schaalbare implementaties, <\/span><span class=\"qc-p1-tag\"><strong>is RoCE v2 de definitieve keuze<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(15, 17, 21);\">. Zijn routbare aard maakt hem ideaal voor dynamische cloudomgevingen en is een sleuteltechnologie voor <\/span><span class=\"qc-p1-tag\"><strong>gedecentraliseerde opslag en hyperconverged infrastructuur<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(15, 17, 21);\">.<\/span><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 De pijlers van een succesvolle RoCE-implementatie<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">RoCE implementeren is niet zomaar een kwestie van nieuwe NIC\u2019s aansluiten. Het vereist een zorgvuldig afgestemde omgeving om de beloofde <strong>netwerken met lage latentie<\/strong>. prestaties te bereiken. De drie belangrijkste pijlers zijn:<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p style=\"margin: 0px;\"><strong>Verliesloos Ethernet:<\/strong> RoCE is zeer gevoelig voor pakketverlies. \u00c9\u00e9n verloren pakket kan enorme latentiepieken veroorzaken doordat het protocol wacht op herzending. Dit vereist een <strong>verliesloos netwerkfabric<\/strong>, meestal bereikt via <strong>Data Center Bridging (DCB)<\/strong> technologie\u00ebn, met name <strong>Prioriteitsstroomregeling (PFC)<\/strong>. PFC cre\u00ebert een \u201cverliesloos\u201d virtueel kanaal voor RoCE-verkeer en pauzeert andere verkeerstypen bij congestie.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Geschikte hardware:<\/strong> U hebt RoCE-compatibele netwerkinterfacekaarten (NIC\u2019s) en switches nodig die DCB-functies ondersteunen. De kwaliteit van uw hardware be\u00efnvloedt direct de stabiliteit van de prestaties.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Precieze configuratie:<\/strong> Het implementeren van <strong>Expliciete congestiemelding (ECN)<\/strong> en juiste Quality-of-Service (QoS)-beleidsregels zijn onmisbaar om vlotte gegevensstromen te garanderen in een <strong>high-performance-computing<\/strong> cluster.<\/p><\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 De onderschatte held: optische transceivers in RoCE-netwerken<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/56259c7d67d14f839d95c4409b9280ff.webp\" alt=\"800G Optical Transceiver\" class=\"wp-image-4707\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/56259c7d67d14f839d95c4409b9280ff.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/56259c7d67d14f839d95c4409b9280ff-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/56259c7d67d14f839d95c4409b9280ff-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/56259c7d67d14f839d95c4409b9280ff-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/56259c7d67d14f839d95c4409b9280ff-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Wanneer netwerken met <strong>RoCE<\/strong>, tot het uiterste worden geduwd, moet elk component optimaal zijn. Dit geldt in het bijzonder voor <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>optische transceivers<\/strong><\/a>\u2014de componenten die elektrische signalen omzetten naar licht en vice versa. Een minderwaardige transceiver kan signaalintegriteitsproblemen, jitter en fouten introduceren die RoCE\u2019s lage-latentiedoelstellingen direct ondermijnen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Voor een RoCE-ingeschakeld netwerk dat de hoogste bandbreedte vereist, hebt u transceivers nodig die zijn gebouwd voor betrouwbaarheid en prestaties. Hier wordt het kiezen van een bewezen leverancier cruciaal. Bijvoorbeeld, de <strong>LINK-PP 800G QSFP-DD SR8<\/strong> optische module is specifiek ontworpen voor dergelijke veeleisende toepassingen. Hij ondersteunt een gegevenssnelheid van 800 Gbps over multimodevezel en biedt de immense, schone datastroom die nodig is voor <strong>AI- en machine learning-workloads<\/strong> die op RoCE vertrouwen voor snelle gegevensinvoer en modeltraining.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bij het beoordelen van <strong>welke optische transceiver het beste is voor high-frequency trading of AI-datacenters<\/strong>, zijn belangrijke overwegingen zoals laag stroomverbruik, hoge thermische stabiliteit en volledige naleving van industriestandaarden van doorslaggevend belang. De <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.link-pp.com\/\"><strong>LINK-PP<\/strong><\/a><strong> 800G<\/strong> serie voldoet aan deze strenge eisen en zorgt ervoor dat de fysieke laag van uw netwerk geen bottleneck is.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 RoCE in actie: praktijktoepassingen<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Waar maakt deze technologie de grootste impact?<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Hyperconverged Infrastructure (HCI):<\/strong> Platforms zoals VMware vSAN gebruiken RoCE om opslagverkeer tussen knooppunten te versnellen, waardoor I\/O-latentie drastisch wordt verminderd.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>AI en machine learning:<\/strong> Het trainen van complexe modellen vereist het verplaatsen van enorme datasets tussen opslag en GPU-servers. RoCE minimaliseert de overdrachtstijd van gegevens en versnelt de gehele trainingscyclus.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Gedecentraliseerde opslag:<\/strong> Oplossingen zoals NVMe-of (NVMe over Fabrics) gebruiken vaak RoCE als transportlaag, waardoor prestaties vergelijkbaar zijn met lokale opslag vanaf externe opslagarrays.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>High-Frequency Trading (HFT):<\/strong> In de handel telt elke microsecond. RoCE biedt de deterministische, ultra-lage latentie die nodig is voor concurrentievoordeel.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Is RoCE geschikt voor uw datacenter?<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><span class=\"qc-p1-tag\" style=\"color: rgb(15, 17, 21);\"><strong>RoCE<\/strong> is een krachtige tool, maar het vereist expertise om deze correct te implementeren. Als uw toepassingen gevoelig zijn voor latentie en u problemen ondervindt met CPU-bottlenecks door netwerkverwerking, dan is RoCE ongetwijfeld een serieuze evaluatie waard. De prestatiewinst voor geschikte workloads kan transformatief zijn.<\/span><\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Klaar om de kracht van een netwerk van de volgende generatie te ervaren?<\/strong> Het gebruik van RoCE-technologie is essentieel voor het bouwen van een moderne, hoogpresterend datacenter.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Veelgestelde vragen (FAQ)<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Wat is een lossless Ethernet-netwerk?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Een lossless Ethernet-netwerk laat geen datapakketten vallen. U krijgt betrouwbare gegevensoverdracht. RoCE werkt het beste op dit type netwerk. Uw gegevens worden soepel en snel verplaatst.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Welke hardware hebt u nodig voor RoCE?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">U hebt netwerkkaarten nodig die <strong>RDMA<\/strong>. ondersteunen. Uw switches moeten lossless Ethernet-functies ondersteunen, zoals Priority Flow Control (PFC). De meeste moderne datacenterapparatuur ondersteunt RoCE.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Wat maakt RoCE anders dan reguliere Ethernet?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">RoCE stelt u in staat om gegevens rechtstreeks tussen het geheugen van computers te verplaatsen. U slaat de CPU en extra stappen over. Dit levert lagere vertraging en snellere gegevensoverdracht op dan reguliere Ethernet.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Welke problemen kunnen er optreden bij RoCE?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">U kunt problemen ondervinden als uw netwerk pakketten laat vallen. De prestaties kunnen afnemen als u lossless Ethernet niet correct configureert. Controleer uw hardware en instellingen voor optimale resultaten.<\/p>","protected":false},"excerpt":{"rendered":"<p>RDMA over Converged Ethernet maakt snelle, lage-latentie gegevensoverdrachten mogelijk met behulp van standaard Ethernet-hardware, waardoor het CPU-gebruik wordt verlaagd en de netwerkeffici\u00ebntie wordt verbeterd.<\/p>","protected":false},"author":1,"featured_media":4706,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[17,24,26],"class_list":["post-4708","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-400g-optical-modules","tag-link-pp","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts\/4708","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/comments?post=4708"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts\/4708\/revisions"}],"predecessor-version":[{"id":11013,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts\/4708\/revisions\/11013"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/media\/4706"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/media?parent=4708"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/categories?post=4708"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/tags?post=4708"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}