{"id":3568,"date":"2025-11-28T00:00:00","date_gmt":"2025-11-28T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/pcs-pma-pmd-work-together\/"},"modified":"2026-06-22T04:34:01","modified_gmt":"2026-06-22T04:34:01","slug":"pcs-pma-pmd-work-together","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/pcs-pma-pmd-work-together","title":{"rendered":"Hoe de PCS-, PMA- en PMD-Ethernet-PHY-lagen samenwerken"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d23fa6e6358741de8a06b78eb2e16176.webp\" alt=\"How PCS, PMA, and PMD Work Together\" class=\"wp-image-3564\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d23fa6e6358741de8a06b78eb2e16176.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d23fa6e6358741de8a06b78eb2e16176-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d23fa6e6358741de8a06b78eb2e16176-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d23fa6e6358741de8a06b78eb2e16176-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d23fa6e6358741de8a06b78eb2e16176-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Moderne, hoge-snelheidsethernet\u201410G, 25G, 40G, 100G en hoger\u2014steunt op een gelaagde architectuur die garandeert dat gegevens betrouwbaar van de MAC-laag naar het fysieke transmissiemedium kunnen worden overgebracht. Onder deze lagen, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/pcs-physical-coding-sublayer-ethernet-explained\/\"><strong>PCS (Fysieke coderingsonderlaag)<\/strong><\/a>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/pma-physical-medium-attachment-ethernet-explained\/\"><strong>PMA (Aansluiting op het fysieke medium)<\/strong><\/a>, en <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/what-is-physical-medium-dependent-pmd\/\"><strong>PMD (Op het fysieke medium afhankelijk)<\/strong><\/a> vormen de kern van de fysieke laag (PHY-stack).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Hoewel nauw met elkaar verbonden, verricht elke laag een afzonderlijke functie. Het begrijpen van hoe zij samenwerken, is essentieel voor netwerkengineers, ontwerpers van optische modules en iedereen die ethernettransceivers of connectiviteitshardware beoordeelt.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Wat elke laag doet<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" ><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/pcs-physical-coding-sublayer-ethernet-explained\/\">PCS \u2014 Fysieke coderingsonderlaag<\/a><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">De PCS verwerkt <strong>gegevenscodering, blokuitlijning, kanaalverdeling en foutdetectie<\/strong>.<br\/>Belangrijke verantwoordelijkheden omvatten:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Codeerschema\u2019s (8b\/10b, 64b\/66b, 256b\/257b)<\/p><\/li><li><p>Kanaalstriping en -deskewing (voor multi-kanaals ethernet)<\/p><\/li><li><p>Woorduitlijning en frameafbakening<\/p><\/li><li><p>Foutbewaking (BER, blokfout)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>De PCS zet MAC-laaggegevens om in een gecodeerde bitstroom<\/strong> geschikt voor hoge-snelheidsserialisatie.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" ><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/pma-physical-medium-attachment-ethernet-explained\/\">PMA \u2014 Fysieke mediumaansluiting<\/a><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">De PMA is verantwoordelijk voor <strong>serialisatie\/deserialisatie<\/strong>, <strong>klokherstel<\/strong>, en <strong>elektrische aanpassing<\/strong> tussen PCS en PMD.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Haar belangrijkste functies:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/serdes-interfaces-high-speed-data-transfer-and-signal-integrity\/\"><strong>SerDes<\/strong><\/a> (parallel-naar-serial en serial-naar-parallel conversie)<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/clock-and-data-recovery-in-modern-communication-systems\/\"><strong>CDR<\/strong><\/a> (klok- en gegevensherstel)<\/p><\/li><li><p>Het genereren van stabiele, hoge-snelheidsbitstromen voor transmissie<\/p><\/li><li><p>Het combineren van meerdere kanalen (bijv. 4\u00d725G \u2192 100G)<\/p><\/li><li><p>Het afhandelen van de elektrische PHY-interface binnen een transceiver<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>De PMA zorgt ervoor dat het signaal schoon, gesynchroniseerd en klaar is voor transmissie via het medium.<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" ><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/what-is-physical-medium-dependent-pmd\/\">PMD \u2014 Fysiek mediumafhankelijk<\/a><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">De PMD is de laag die direct interageert met het <strong>werkelijke transmissiemedium<\/strong>, zoals glasvezel, koper, DAC of AOC.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">De PMD omvat:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Optische zenders\/ontvangers (bijv. lasers, fotodiodes)<\/p><\/li><li><p>Elektrische drivers en versterkers<\/p><\/li><li><p>Golflengtekeuze<\/p><\/li><li><p>Uitzendvermogen- en gevoeligheidsregeling<\/p><\/li><li><p>Mediumspecifieke parameters (OM3\/OM4-glasvezel, 100-ohm koperparen, enz.)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>De PMD zet het elektrische signaal van de PMA om in optische of kopergebaseerde signalen die via de fysieke verbinding reizen.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Hoe PCS, PMA en PMD samenwerken<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8f686013e096433f9a02240754eb8dec.webp\" alt=\"PCS, PMA, and PMD Work Together\" class=\"wp-image-3565\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8f686013e096433f9a02240754eb8dec.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8f686013e096433f9a02240754eb8dec-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8f686013e096433f9a02240754eb8dec-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8f686013e096433f9a02240754eb8dec-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8f686013e096433f9a02240754eb8dec-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">De gegevensstroom door de PHY-stack volgt deze pijplijn:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Stap 1: PCS codeert en organiseert gegevens<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Gegevens van de MAC zijn:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Gecodeerd (64b\/66b of andere)<\/p><\/li><li><p>Verdeeld over lanes (indien multi-lane)<\/p><\/li><li><p>Uitgelijnd en blok-gesynchroniseerd<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Dit bereidt de gegevens voor op high-speed serialisatie terwijl de signaalintegriteit wordt behouden.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Stap 2: PMA converteert en synchroniseert de bitstroom<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PMA:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Serialiseert de PCS-gecodeerde gegevens naar een continue bitstroom<\/p><\/li><li><p>Herstelt de kloktiming uit de binnenkomende gegevens<\/p><\/li><li><p>Past toe: <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/serdes-interfaces-high-speed-data-transfer-and-signal-integrity\/\">SerDes<\/a> equalisatie en retiming<\/p><\/li><li><p>Zorgt voor lane bonding bij multi-lane protocollen (XLAUI, CAUI-4, enz.)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Dit stabiliseert het signaal v\u00f3\u00f3r verzending.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Stap 3: PMD zendt het signaal via het medium<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">De PMD-laag:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Converteert elektrische signalen naar optische signalen (via laser\/fotodiode)<\/p><\/li><li><p>Of past elektrische uitgangen aan voor koper (BASE-T, DAC)<\/p><\/li><li><p>Regelt modulatieformaten (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/understanding-non-return-to-zero-in-digital-communication\/\">NRZ<\/a>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\">PAM4<\/a>)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Aan de ontvangzijde keert de PMD dit proces om en levert schone elektrische signalen terug aan de PMA.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Waarom deze lagen belangrijk zijn<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Voor prestaties van optische transceivers<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Deze lagen bepalen:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Maximale datarate<\/p><\/li><li><p>Mogelijke koppelafstand<\/p><\/li><li><p>Foutprestaties (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/understanding-what-is-bit-error-rate\/\">BER<\/a>)<\/p><\/li><li><p>Latentie<\/p><\/li><li><p>Energie-effici\u00ebntie<br><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">PMA en PMD zijn bijzonder kritisch bij <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/488452.htm\"><strong>100G<\/strong><\/a><strong>\/<\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473139.htm\"><strong>200G<br><\/strong><\/a><strong>\/<\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472016.htm\"><strong>400G<\/strong><\/a><strong> PAM4-transceivers<\/strong>, waarbij klokherstel en optische modulatie geavanceerde DSP vereisen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Voor systeemintegrators<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Een duidelijk begrip van de interacties tussen PCS-PMA-PMD helpt bij:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Het selecteren van compatibele <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26155-1g-sfp.htm\">SFP<\/a>\/<a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491483.htm\">QSFP-modules<\/a><\/p><\/li><li><p>Het oplossen van problemen met optische koppelingen<\/p><\/li><li><p>Het garanderen van juiste lane-toewijzing (bijv. breakouts)<\/p><\/li><li><p>Het diagnosticeren van coderings- of uitlijningsfouten<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >Hoe LINK-PP-hardware de stabiliteit van PCS\/PMA\/PMD ondersteunt<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">LINK-PP levert Ethernet-magnetische componenten, accessoires voor optische transceivers en hoogwaardige verbindingsonderdelen die zijn ontworpen voor:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Lage inbrengverliezen en hoge signaalintegriteit (ondersteunt PMA SerDes-prestaties)<\/p><\/li><li><p>EMI-onderdrukking voor stabiele PCS\/PMA-werking<\/p><\/li><li><p>Robuuste elektrische kenmerken voor lange afstanden<\/p><\/li><li><p>Compatibiliteit met grote netwerk-OEM\u2019s<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Hoogwaardige connectoren, RJ45-magnetica en optische componenten helpen de <strong>signaalhelderheid over alle PHY-sublagen<\/strong>, te behouden, wat betrouwbare werking garandeert van PCS-codering tot PMD-verzending.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9240db12025d485c8973a6532e9fb4d7.jpg\" alt=\"LINK-PP Solutions\" class=\"wp-image-3566\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9240db12025d485c8973a6532e9fb4d7.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9240db12025d485c8973a6532e9fb4d7-300x178.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9240db12025d485c8973a6532e9fb4d7-1024x608.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9240db12025d485c8973a6532e9fb4d7-768x456.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9240db12025d485c8973a6532e9fb4d7-18x12.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >Conclusie<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>PCS, PMA en PMD werken samen als drie gesynchroniseerde lagen van de Ethernet PHY<\/strong>, waardoor een essenti\u00eble pijplijn ontstaat die het mogelijk maakt dat gegevens met hoge snelheid schoon en betrouwbaar over glasvezel- en kopernetwerken worden verzonden.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/pcs-physical-coding-sublayer-ethernet-explained\/\">PCS<\/a> verwerkt <strong>codering en uitlijning<\/strong><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/pma-physical-medium-attachment-ethernet-explained\/\">PMA<\/a> verwerkt <strong>serialisatie en timing<\/strong><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/what-is-physical-medium-dependent-pmd\/\">PMD<\/a> verwerkt <strong>mediumspecifieke transmissie<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Het begrijpen van hun rollen is fundamenteel bij het beoordelen van optische modules met hoge snelheid, netwerkarchitecturen of fysieke-laagprestaties.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >FAQ<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Wat is het verschil tussen PCS, PMA en PMD in Ethernet?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PCS (Physical Coding Sublayer) verwerkt gegevenscodering, blokuitlijning, lane-verdeling en foutdetectie.<br\/>PMA (Physical Medium Attachment) voert serialisatie\/deserialisatie (SerDes) en klokherstel uit.<br\/>PMD (Physical Medium Dependent) communiceert met het daadwerkelijke fysieke medium \u2014 het uitzenden en ontvangen van elektrische of optische signalen.<\/p>\n\n\n\n<hr class=\"wp-block-separator\" \/>\n\n\n\n<h3 class=\"wp-block-heading\" >Waarom moeten PCS, PMA en PMD samenwerken?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Deze drie lagen vormen de volledige Ethernet-PHY-pijplijn. De PCS bereidt gegevens voor, de PMA zet deze om in geserialiseerde bitstromen en de PMD verzendt deze over koper of glasvezel. Alleen door samen te werken kan de PHY de tijdsynchronisatie, signaalintegriteit en interoperabiliteit op high-speed-koppelingen behouden.<\/p>\n\n\n\n<hr class=\"wp-block-separator\" \/>\n\n\n\n<h3 class=\"wp-block-heading\" >Gebruikt elke Ethernet-snelheid PCS, PMA en PMD?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ja. Ongeacht de snelheid\u20141G, 10G, 25G, 100G of 400G\u2014zijn deze blokken aanwezig in de Ethernet-PHY-architectuur. Hun interne implementaties kunnen vari\u00ebren (bijv. verschillende coderingsschema\u2019s of SerDes-lanes), maar de functionele structuur blijft consistent.<\/p>\n\n\n\n<hr class=\"wp-block-separator\" \/>\n\n\n\n<h3 class=\"wp-block-heading\" >Hoe be\u00efnvloedt de PCS de koppelingstabiliteit en prestaties?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">De PCS verbetert de koppelingstevigheid door:<br\/>\u2022 blokcodering uit te voeren (bijv. 64b\/66b, 256b\/257b)<br\/>\u2022 synchronisatieheaders toe te voegen<br\/>\u2022 laneverdeling en -ontvertraging (deskew) mogelijk te maken<br\/>\u2022 foutdetectie te bieden (bijv. CRC\/FEC)<br\/>Deze functies verminderen de bitfoutratio en ondersteunen betrouwbare transmissie op lange afstand en met hoge snelheid.<\/p>\n\n\n\n<hr class=\"wp-block-separator\" \/>\n\n\n\n<h3 class=\"wp-block-heading\" >Welke rol speelt de PMA in optische transceivers?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">In <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">SFP-, SFP+-, SFP28-, QSFP+- en QSFP28-modules<\/a>, bevat de PMA-laag de SerDes- en klokherstelcircuits die de elektrische lanes aan de hostzijde afstemmen op optische stuurcircuits. Zij waarborgt de nauwkeurigheid van de tijdsynchronisatie, de uitlijning van de datalanes en een naadloze conversie tussen het elektrische en optische domein.<\/p>\n\n\n\n<hr class=\"wp-block-separator\" \/>\n\n\n\n<h3 class=\"wp-block-heading\" >Wordt de PMD alleen gebruikt voor optische vezel?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Nee. De PMD wordt zowel voor vezel als voor koper gebruikt.<br\/>\u2022 In optische transceivers omvat de PMD lasers, fotodiodes en modulatiecircuits.<br\/>\u2022 In koperinterfaces (bijv. BASE-T) omvat de PMD analoge front-ends, transformatoren en <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-17492-integrated-rj45-connector.htm\">RJ45-aansluitingen<\/a>.<br\/>Haar taak is altijd om PHY-signalen met het fysieke medium te koppelen.<\/p>\n\n\n\n<hr class=\"wp-block-separator\" \/>\n\n\n\n<h3 class=\"wp-block-heading\" >Hoe be\u00efnvloeden deze lagen de modulecompatibiliteit?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Voor interoperabiliteit moeten de PCS-codering, het PMA-SerDes-gedrag en de PMD-optische\/elektrische specificaties voldoen aan <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/ieee-802-3-ethernet-standard-explained\/\">IEEE 802.3-normen<\/a>. Dit garandeert dat transceivers\u2014zelfs van verschillende merken\u2014naadloos werken met switches, routers en NIC\u2019s, mits zij dezelfde standaard delen.<\/p>","protected":false},"excerpt":{"rendered":"<p>Leer hoe PCS, PMA en PMD samenwerken binnen de Ethernet-PHY om betrouwbare, hoge-snelheidsgegevensoverdracht over glasvezel- en kopernetwerken mogelijk te maken.<\/p>","protected":false},"author":1,"featured_media":3567,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[22,24,26],"class_list":["post-3568","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-integrated-rj45-connectors","tag-link-pp","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts\/3568","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/comments?post=3568"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts\/3568\/revisions"}],"predecessor-version":[{"id":10824,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts\/3568\/revisions\/10824"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/media\/3567"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/media?parent=3568"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/categories?post=3568"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/tags?post=3568"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}