{"id":3516,"date":"2025-12-02T00:00:00","date_gmt":"2025-12-02T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/ieee-802-3cd-50g-100g-200g-pam4-ethernet\/"},"modified":"2026-06-22T08:57:41","modified_gmt":"2026-06-22T08:57:41","slug":"ieee-802-3cd-50g-100g-200g-pam4-ethernet","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/ieee-802-3cd-50g-100g-200g-pam4-ethernet","title":{"rendered":"IEEE 802.3cd uitgelegd: 50G-, 100G- en 200G-Ethernet met PAM4"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540.webp\" alt=\"What Is IEEE 802.3cd?\" class=\"wp-image-3513\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Wat is IEEE 802.3cd?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">IEEE 802.3cd is de Ethernet-standaard die de fysieke laag (PHY) en <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/what-is-physical-medium-dependent-pmd\/\">Fysieke mediumafhankelijke laag (PMD)<\/a> specificaties definieert voor <strong>50 GbE, 100 GbE en 200 GbE<\/strong> netwerken met behulp van <strong>50G PAM4-lanes<\/strong>. De standaard werd in 2018 afgerond en introduceerde single-lane 50G-signaleren en multi-lane-combinaties (2\u00d750G en 4\u00d750G), waardoor schaalbare high-speed Ethernet mogelijk wordt met verbeterde poorteffici\u00ebntie en lagere kosten per bit.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">De standaard speelt een centrale rol in moderne datacenters, waar PAM4-optische transceivers\u2014met name <strong>SFP56, <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491591.htm\"><strong>QSFP28<\/strong><\/a><strong>, QSFP56 en QSFP-DD<\/strong>\u2014op grote schaal worden ingezet in migratiepaden van 25G naar 200G.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Waarom IEEE 802.3cd PAM4-modulatie gebruikt<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Een kenmerkende eigenschap van 802.3cd is de overgang van NRZ (PAM2) naar <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\"><strong>PAM4<\/strong> modulatie<\/a>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Belangrijkste voordelen van PAM4<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Hogere gegevensdichtheid:<\/strong> PAM4 codeert twee bits per symbool, waardoor de doorvoer effectief binnen dezelfde bandbreedte wordt verdubbeld.<\/p><\/li><li><p><strong>Haalbaarheid van single-lane 50G:<\/strong> Bereikt 50 Gb\/s per lane bij ongeveer 50 GBd symboolfrequentie.<\/p><\/li><li><p><strong>Betere schaalbaarheid:<\/strong> Maakt bandwidthuitbreiding van 50G \u2192 100G \u2192 200G mogelijk zonder herontwerp van poortformaat.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Met PAM4 kon Ethernet evolueren met vertrouwde moduleformaten terwijl veel hogere totaalsnelheden werden ondersteund.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc PMD\u2019s en interface-typen gedefinieerd onder IEEE 802.3cd<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >50 GbE PMD\u2019s<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>50GBASE-SR<\/strong> \u2013 Kortbereik multimodevezel met gebruik van \u00e9\u00e9n 50G PAM4-lane.<\/p><\/li><li><p><strong>50GBASE-FR<\/strong> \u2013 Enkelmodusvezel, meestal tot 2 km.<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491591.htm\"><strong>50GBASE-LR<\/strong><\/a> \u2013 SMF met bereik van 10 km voor campus- en metrotoepassingen.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >100 GbE PMD\u2019s (2\u00d750G)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>100GBASE-FR2<\/strong> \u2013 Twee PAM4-lanes over SMF, matig bereik.<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491583.htm\"><strong>100GBASE-LR2<\/strong><\/a> \u2013 Twee-lane langbereik SMF-toepassingen.<\/p><\/li><li><p><strong>100GBASE-DR\/DR2<\/strong> \u2013 Geoptimaliseerd voor kort- tot middellang bereik SMF-koppelingen in datacenters.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >200 GbE PMD\u2019s (4\u00d750G)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473139.htm\"><strong>200GBASE-SR4<\/strong><\/a> \u2013 Vier 50G-lanes op parallelle MMF; ideaal voor hoge-dichtheid leaf\/spine-connectiviteit.<\/p><\/li><li><p><strong>200GBASE-FR4 \/ LR4<\/strong> \u2013 Vier-lane SMF-oplossingen die respectievelijk bereiken van 2 km en 10 km mogelijk maken.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">3cd definieert elektrische en optische parameters voor deze interfaces, inclusief TDECQ, zender-OMAouter, ontvangergevoeligheid en lane-per-lane BER-doelstellingen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Inzetscenario\u2019s in moderne datacenters<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Single-lane 50G voor servers<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Veel hyperscale- en enterprise-datacenters nemen <strong>50G SFP56<\/strong> interfaces voor server-toegangslinks over, waardoor 25G wordt vervangen als standaard knooppuntbandbreedte.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >100G als uplinklaag<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Met behulp van 2\u00d750G lanes blijven 100G-links een primaire aggregatielaag tussen Top-of-Rack (ToR)- en leaf-switches. <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472577.htm\">100G QSFP28<\/a> of SFP-DD-modules bieden effici\u00ebnte dichtheid en achterwaartse compatibiliteit.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >200G voor leaf-naar-spine-fabrics<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473139.htm\">200G QSFP56<\/a> of QSFP-DD-transceivers ondersteunen vier-lane 50G-architecturen met breakoutflexibiliteit. Een enkele 200G-poort kan worden opgesplitst in <strong>4\u00d750G<\/strong> voor servers of aggregatienodes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Breakoutflexibiliteit<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">De lane-gebaseerde architectuur maakt 802.3cd ideaal voor:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>200G QSFP56 \u2192 4\u00d750G SFP56<\/p><\/li><li><p>100G QSFP28 \u2192 2\u00d750G SFP56<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Dit sluit goed aan bij de volgende generatie overgang van 25G naar 50G voor servers.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Het juiste optische transceivers kiezen voor IEEE 802.3cd<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480.webp\" alt=\"802.3cd-compliant optical transceivers\" class=\"wp-image-3514\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Bij het plannen van een 50G\/100G\/200G-netwerk moet de keuze van transceivers overeenkomen met <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/what-is-physical-medium-dependent-pmd\/\">PMD<\/a> type, vezelbereik en vormfactor van de switchpoort.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Voor IEEE 802.3cd-deployments biedt LINK-PP de volgende productcategorie\u00ebn:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 50G-optische transceivers (SFP56 \/ QSFP28)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Voor single-lane 50GBASE-SR\/FR\/LR en 50G-servertoegang:<br\/>\ud83d\udd17 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27046-50g-qsfp28-sfp56.htm\">https:\/\/www.l-p.com\/store-27046-50g-qsfp28-sfp56.htm<\/a><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 100G-optische transceivers (QSFP28 \/ SFP-DD)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ideaal voor 2\u00d750G-uplinks, 100G-spine-aggregatie en DR\/FR\/LR-toepassingen:<br\/>\ud83d\udd17 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\">https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm<\/a><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 200G-optische transceivers (QSFP-DD \/ QSFP56)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ontworpen voor 4\u00d750G leaf-spine-fabrics en breakoutcompatibiliteit:<br\/>\ud83d\udd17 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26224-200g-qsfp-dd-qsfp56.htm\">https:\/\/www.l-p.com\/store-26224-200g-qsfp-dd-qsfp56.htm<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Deze modules ondersteunen PAM4-signaleren en voldoen aan IEEE-interoperabiliteitsdoelen zoals TDECQ-prestaties, ontvangergevoeligheid en consistentie van lane-BER.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Interoperabiliteits- en validatiechecklist<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Om een betrouwbare 802.3cd-deployment te garanderen, controleren engineers doorgaans:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Het juiste PMD-type<\/strong> (SR, FR, LR, DR) voor linkbudget en bereik.<\/p><\/li><li><p><strong>Overeenkomst van vormfactor<\/strong> (SFP56, QSFP28, QSFP56, QSFP-DD).<\/p><\/li><li><p><strong>Optische vermogensniveaus<\/strong> inclusief OMAouter en gemiddelde zendvermogens.<\/p><\/li><li><p><strong>Ontvangergevoeligheid<\/strong> onder gestresste PAM4-omstandigheden.<\/p><\/li><li><p><strong>Lane-BER-doelen<\/strong> en <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/fec-forward-error-correction-in-optical-communication\/\">FEC<\/a> compatibiliteit.<\/p><\/li><li><p><strong>Breakoutmapping<\/strong> bij het combineren van 200G \u2194 50G-eindpunten.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Conclusie<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">IEEE 802.3cd heeft de technische bouwstenen gelegd voor de huidige <strong>50G-, 100G- en 200G-Ethernet<\/strong>, waarbij <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\">PAM4-modulatie<\/a> naar mainstream-implementatie. De op banen gebaseerde architectuur maakt schaalbare, kosteneffici\u00ebnte bandbreedte-upgrades mogelijk, terwijl vertrouwde moduleformaten worden behouden.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Naarmate datacenters voortdurend migreren van 25G en 40G naar snellere netwerken, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473139.htm\">optische transceivers die voldoen aan IEEE 802.3cd<\/a>\u2014zoals de 50G\/100G\/200G-productfamilies van LINK-PP\u2014vormen een betrouwbare basis voor verbindingen van de volgende generatie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Voor gedetailleerde specificaties en productselectie, bekijk <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">LINK-PP\u2019s<\/a> het volledige assortiment IEEE 802.3cd-compatibele transceivers.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Belangrijke optische en elektrische termen in IEEE 802.3cd (mini-woordenlijst)<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2605 TDECQ (Transmitter and Dispersion Eye Closure for PAM4)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">TDECQ is een metriek voor zenderkwaliteit die wordt gebruikt bij PAM4-gebaseerde interfaces. Het kwantificeert hoeveel de optische oogdiagram \u201csluit\u201d nadat het signaal dispersie, ruis en andere kanaalverstooringen heeft ondergaan. Een <strong>lagere TDECQ-waarde<\/strong> geeft een schoner PAM4-signaal aan met een betere linkmarge. IEEE 802.3cd gebruikt TDECQ als primaire vereiste voor 50G-, 100G- en 200G-optische zenders.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2605 OMAouter (Outer Optical Modulation Amplitude)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">OMAouter vertegenwoordigt de <strong>het verschil tussen het hoogste en laagste optische vermogensniveau<\/strong> (niveau 3 en niveau 0) in een PAM4-signaal. Aangezien PAM4 vier discrete niveaus gebruikt, geeft OMAouter een nauwkeuriger weergave van de modulatiediepte dan het gemiddelde vermogen. Een <strong>hogere OMAouter<\/strong> verbetert over het algemeen de gevoeligheid van de ontvanger en draagt bij aan het waarborgen van prestaties die voldoen aan de normen voor 50GBASE-SR\/FR\/LR en multilane varianten.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2605 BER (Bit Error Rate \/ bitfoutenratio)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/understanding-what-is-bit-error-rate\/\">BER<\/a> meet de verhouding tussen foutieve bits en het totale aantal verzonden bits. IEEE 802.3cd specificeert <strong>lane-per-lane BER-doelstellingen<\/strong>, meestal met behulp van een <strong>pre-FEC BER-doelwaarde van 2,4\u00d710\u207b\u2074<\/strong> voor PAM4-lanes. Met sterke Forward Error Correction (zoals KP4 FEC) bereikt de post-FEC BER de betrouwbaarheid die vereist is voor hyperscale- en cloud-datacenternetwerken.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Veelgestelde vragen<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Wat is IEEE 802.3cd?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">IEEE 802.3cd is een Ethernet-standaard die fysieke-laagspecificaties definieert voor <strong>50GbE, 100GbE en 200GbE<\/strong> met behulp van <strong>PAM4-modulatie<\/strong>. Het omvat interfaces zoals <strong>50GBASE-SR\/FR\/LR<\/strong>, <strong>100GBASE-SR2<\/strong>, en <strong>200GBASE-SR4<\/strong>, gericht op moderne datacentrum- en high-performance-netwerkomgevingen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Welk modulatieformaat gebruikt IEEE 802.3cd?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">IEEE 802.3cd vereist <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/what-is-physical-medium-dependent-pmd\/\"><strong>PAM4 (4-niveau pulsamplitudemodulatie)<\/strong><\/a> voor alle 50G-per-lane-interfaces. PAM4 verdubbelt de bitrate per lane ten opzichte van NRZ, terwijl de baudrate hetzelfde blijft, waardoor schaalbare 50G-, 100G- en 200G-Ethernetarchitecturen mogelijk worden.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Ondersteunt IEEE 802.3cd achterwaartse compatibiliteit met NRZ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ja, in veel implementaties kunnen PAM4-gebaseerde links co\u00ebxisteren met NRZ-interfaces <strong>mits de hostpoort, de elektrische interface en de optische module zijn ontworpen om gemengde omgevingen te ondersteunen<\/strong>. PAM4 en NRZ kunnen echter niet op \u00e9\u00e9n enkele link met elkaar communiceren; beide uiteinden moeten hetzelfde modulatieformaat gebruiken.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Wat zijn de typische toepassingsgebieden van IEEE 802.3cd?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">IEEE 802.3cd wordt veel gebruikt voor:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>50G-servertoegang (SFP56, QSFP28)<\/p><\/li><li><p>100G-spine-\/aggregatieniveaus<\/p><\/li><li><p>200G-leaf-spine-fabrics<\/p><\/li><li><p>Cloud-, AI\/ML-clusters en hyperscale-netwerken<\/p><\/li><li><p>50G-per-lane uplinks in modulaire architecturen (2\u00d750G, 4\u00d750G)<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Welke optische transceivers zijn conform IEEE 802.3cd?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">IEEE 802.3cd ondersteunt een breed scala aan 50G-, 100G- en 200G-optische modules, waaronder:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>50GBASE-SR\/FR\/LR<\/strong> (SFP56 \/ QSFP28) voor single-lane 50GbE<\/p><\/li><li><p><strong>100GBASE-SR2<\/strong> en 2\u00d750G-breakoutmodules (QSFP28 \/ SFP-DD)<\/p><\/li><li><p><strong>200GBASE-SR4\/DR4\/FR4<\/strong> (QSFP-DD \/ QSFP56)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">LINK-PP<\/a> biedt IEEE 802.3cd-conforme opties voor alle snelheidsklassen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Hoe verhoudt IEEE 802.3cd zich tot IEEE 802.3bs (400G) en 802.3cu?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/knowledge-center\/ieee-802-3bs-200g-400g-ethernet-standard\/\"><strong>3bs<\/strong><\/a> definieert 400GbE en maakt ook gebruik van 50G-lanes, maar richt zich op architecturen met een hoger aantal lanes (bijv. 8\u00d750G).<\/p><\/li><li><p><strong>3cu<\/strong> breidt 100G\/400G uit naar langere-reikwijdte SMF-toepassingen (DR\/FR\/LR).<\/p><\/li><li><p><strong>3cd<\/strong> vult de kloof op voor <strong>single-lane- en multilane 50G-per-lane Ethernet<\/strong>, waardoor schaalbare migratiepaden mogelijk worden van 25G \u2192 50G \u2192 100G\/200G \u2192 400G.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Is IEEE 802.3cd geschikt voor AI\/ML en HPC-workloads van de volgende generatie?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ja. De <strong>50G-per-lane PAM4-architectuur<\/strong> sluit aan bij high-bandwidth fabrics die worden gebruikt in AI-clusters, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/nl\/glossary\/what-is-hpc-high-performance-computing\/\">HPC-systemen<br><\/a>, en grootschalige GPU-netwerken. Het maakt low-latency spine-leaf-topologie\u00ebn mogelijk met flexibele breakoutopties zoals 4\u00d750G of 2\u00d7100G.<\/p>","protected":false},"excerpt":{"rendered":"<p>Leer wat IEEE 802.3cd definieert voor 50G-, 100G- en 200G-Ethernet. Verken PAM4-technologie, belangrijke PMD\u2019s, implementatiegevallen en geschikte LINK-PP-optische transceivers.<\/p>","protected":false},"author":1,"featured_media":3515,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13,24,26],"class_list":["post-3516","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules","tag-link-pp","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts\/3516","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/comments?post=3516"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts\/3516\/revisions"}],"predecessor-version":[{"id":11328,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/posts\/3516\/revisions\/11328"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/media\/3515"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/media?parent=3516"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/categories?post=3516"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/nl\/wp-json\/wp\/v2\/tags?post=3516"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}