{"id":7179,"date":"2026-05-11T00:00:00","date_gmt":"2026-05-11T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/glossary\/what-is-fcoe-fibre-channel-over-ethernet\/"},"modified":"2026-06-22T03:31:42","modified_gmt":"2026-06-22T03:31:42","slug":"what-is-fcoe-fibre-channel-over-ethernet","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-fcoe-fibre-channel-over-ethernet","title":{"rendered":"Cos\u2019\u00e8 FCoE (Fibre Channel over Ethernet)? Guida completa"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"628\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a4d501215dba4d74bd9e3c85ee864941.jpg\" alt=\"What Is FCoE Fibre Channel over Ethernet? A Complete Guide\" class=\"wp-image-7170\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a4d501215dba4d74bd9e3c85ee864941.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a4d501215dba4d74bd9e3c85ee864941-300x157.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a4d501215dba4d74bd9e3c85ee864941-1024x536.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a4d501215dba4d74bd9e3c85ee864941-768x402.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a4d501215dba4d74bd9e3c85ee864941-18x9.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">I moderni data center non gestiscono pi\u00f9 soltanto il traffico Ethernet tradizionale. L\u2019infrastruttura aziendale odierna deve supportare contemporaneamente applicazioni cloud, piattaforme di virtualizzazione, carichi di lavoro AI e reti di storage ad alta velocit\u00e0, mantenendo al contempo bassa latenza, scalabilit\u00e0 ed efficienza operativa. Con l\u2019aumento dei requisiti di prestazioni dello storage, le organizzazioni hanno iniziato a cercare modi per semplificare la complessit\u00e0 derivante dalla gestione di infrastrutture LAN e SAN separate.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c8 qui che <strong>FCoE (Canale Fibre su Ethernet)<\/strong> divenne una tecnologia di rete importante.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">FCoE \u00e8 un protocollo di rete convergente che incapsula frame Fibre Channel nativi all\u2019interno di pacchetti Ethernet, consentendo al traffico di storage e al traffico di rete standard di condividere la stessa infrastruttura fisica Ethernet. Invece di mantenere switch Fibre Channel, adattatori e cablaggi indipendenti affiancati alle reti Ethernet, i data center possono trasportare entrambi i tipi di traffico attraverso un ambiente Ethernet ad alta velocit\u00e0 unificato.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In termini semplici, FCoE combina l'affidabilit\u00e0 e le capacit\u00e0 di storage delle tradizionali SAN Fibre Channel con la flessibilit\u00e0 e la scalabilit\u00e0 delle reti Ethernet.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La tecnologia fu originariamente sviluppata per ridurre:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>La complessit\u00e0 del cablaggio nel data center<\/p><\/li>\n\n\n\n<li><p>I costi hardware e infrastrutturali<\/p><\/li>\n\n\n\n<li><p>I requisiti di alimentazione e raffreddamento<\/p><\/li>\n\n\n\n<li><p>Il sovraccarico di gestione della rete<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Allo stesso tempo, FCoE preserva molte delle caratteristiche richieste dagli ambienti enterprise di storage, tra cui prestazioni deterministiche, bassa latenza e comportamento di trasporto senza perdite.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A differenza di protocolli come iSCSI o <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-nvme-non-volatile-memory-express\/\">NVMe<\/a>\/TCP, FCoE non converte il traffico di storage in <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/tcp-ip-model-network-communication-layers-and-data-exchange\/\">TCP\/IP<\/a> pacchetti. Invece, mantiene intatto il protocollo Fibre Channel trasportandolo su Ethernet tramite meccanismi specializzati quali <strong>Data Center Bridging (DCB)<\/strong> and <strong>Controllo del flusso prioritario (PFC)<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Di conseguenza, FCoE \u00e8 stato ampiamente adottato nelle architetture convergenti <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/what-is-a-data-center\/\">centro dati<\/a> da fornitori quali Cisco, Dell EMC, Brocade, NetApp e VMware, soprattutto durante la transizione dalle tradizionali infrastrutture Fibre Channel verso reti di storage basate su Ethernet.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Un altro aspetto importante di FCoE \u00e8 il suo stretto legame con la moderna connettivit\u00e0 ottica Ethernet. Poich\u00e9 FCoE opera sui livelli fisici Ethernet, utilizza tipicamente moduli Ethernet standard <a target=\"\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">trasceivers ottici<\/a> quali:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a href=\"https:\/\/www.l-p.com\/store-26192-10g-sfp.htm\" target=\"_self\">SFP+ 10G<\/a> Moduli SR\/LR<\/p><\/li>\n\n\n\n<li><p><a href=\"https:\/\/www.l-p.com\/store-26225-25g-sfp28.htm\" target=\"_self\">SFP28 25G<\/a> moduli<br><\/p><\/li>\n\n\n\n<li><p><a href=\"https:\/\/www.l-p.com\/store-26153-40g-qsfp.htm\" target=\"_self\">QSFP+ 40G<\/a> moduli<br><\/p><\/li>\n\n\n\n<li><p><a href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\" target=\"_self\">Moduli ottici 100G QSFP28<\/a> moduli<br><\/p><\/li>\n\n\n\n<li><p>Soluzioni di cablaggio ad alta velocit\u00e0 DAC e AOC<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ci\u00f2 crea un forte collegamento tra le strategie di implementazione di FCoE e la selezione, la compatibilit\u00e0 e l\u2019interoperabilit\u00e0 dei moduli ottici nel data center.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In questa guida, imparerai:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Cos\u2019\u00e8 FCoE \u2013 Fibre Channel over Ethernet<\/p><\/li>\n\n\n\n<li><p>Come funziona FCoE all\u2019interno dei moderni data center<\/p><\/li>\n\n\n\n<li><p>Il rapporto tra FCoE e i transceiver ottici<\/p><\/li>\n\n\n\n<li><p>Il confronto tra FCoE, Fibre Channel, Ethernet e iSCSI<\/p><\/li>\n\n\n\n<li><p>Quali moduli ottici sono comunemente utilizzati nelle reti FCoE<\/p><\/li>\n\n\n\n<li><p>I vantaggi, i limiti e gli scenari di utilizzo reali di FCoE<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Che tu sia un ingegnere di rete, un system integrator, un architetto di storage o un acquirente di transceiver ottici, comprendere FCoE rimane fondamentale per progettare infrastrutture convergenti efficienti e ad alte prestazioni negli attuali ambienti enterprise.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u2705 Cos\u2019\u00e8 FCoE \u2013 Fibre Channel over Ethernet?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">FCoE (Fibre Channel over Ethernet) \u00e8 una tecnologia di rete di storage che consente al traffico Fibre Channel nativo di essere trasmesso su reti Ethernet ad alta velocit\u00e0. Invece di utilizzare un\u2019infrastruttura SAN Fibre Channel completamente separata, con switch, adattatori e cablaggi dedicati, FCoE incapsula i frame Fibre Channel all\u2019interno di frame Ethernet, permettendo sia al traffico di storage sia al traffico LAN standard di operare sulla stessa infrastruttura di rete convergente. L\u2019obiettivo di FCoE non \u00e8 sostituire Fibre Channel in s\u00e9, ma semplificare l\u2019architettura del data center unendo storage e rete Ethernet in un unico ambiente di trasporto, preservando al contempo la bassa latenza, l'affidabilit\u00e0 e le caratteristiche di trasporto senza perdite richieste dai sistemi enterprise di storage.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e13d321e17314b978591358eb9ec9a37.jpg\" alt=\"What Is FCoE Fibre Channel over Ethernet?\" class=\"wp-image-7171\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e13d321e17314b978591358eb9ec9a37.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e13d321e17314b978591358eb9ec9a37-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e13d321e17314b978591358eb9ec9a37-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e13d321e17314b978591358eb9ec9a37-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e13d321e17314b978591358eb9ec9a37-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Definizione semplice di FCoE<\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 239px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"239\"><p>Term<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Definizione<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"239\"><p>FCoE<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibre Channel su Ethernet<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"239\"><p>Scopo principale<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Trasportare il traffico di storage Fibre Channel su Ethernet<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"239\"><p>Funzione principale<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Incapsulare i frame FC all\u2019interno di frame Ethernet<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"239\"><p>Beneficio principale<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Infrastruttura LAN e SAN convergente<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"239\"><p>Ambiente tipico<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Data center enterprise e reti di storage<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"239\"><p>Velocit\u00e0 comuni<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Ethernet 10G, 25G, 40G e 100G<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"239\"><p>Requisito fondamentale<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Ethernet senza perdite mediante Data Center Bridging (DCB)<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Cosa significa FCoE<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">FCoE sta per:<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>Fibre Channel su Ethernet<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">Il nome descrive direttamente il funzionamento della tecnologia:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Fibre Channel (FC)<\/strong> \u00e8 il protocollo tradizionale di rete di storage ad alte prestazioni utilizzato negli ambienti SAN (Storage Area Network).<\/p><\/li>\n\n\n\n<li><p><strong>Su Ethernet<\/strong> significa che tali frame Fibre Channel vengono trasportati attraverso l\u2019infrastruttura Ethernet anzich\u00e9 attraverso reti fisiche Fibre Channel dedicate.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c8 importante sottolineare che FCoE non converte Fibre Channel in traffico TCP\/IP. Il protocollo Fibre Channel originale rimane intatto durante tutta la trasmissione. FCoE modifica semplicemente il livello di trasporto, passando dai cablaggi e dagli switch Fibre Channel nativi al trasporto basato su Ethernet.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Perch\u00e9 esiste FCoE<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Tradizionalmente, i data center enterprise hanno mantenuto due infrastrutture di rete completamente separate:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 305px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"305\"><p>Tipo di rete<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Scopo<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"305\"><p>Ethernet <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/local-area-network-lan-modern-networking-fast-secure-connections\/\">LAN<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Traffico dati e applicativo standard<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"305\"><p>Fibre Channel <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-you-should-know-about-storage-area-network-san\/\">SAN<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Traffico di storage<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Questa architettura ha aumentato:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>La complessit\u00e0 del cablaggio<\/p><\/li>\n\n\n\n<li><p>Il numero di switch<\/p><\/li>\n\n\n\n<li><p>I requisiti di adattatori<\/p><\/li>\n\n\n\n<li><p>Consumo energetico<\/p><\/li>\n\n\n\n<li><p>Le esigenze di raffreddamento<\/p><\/li>\n\n\n\n<li><p>I costi infrastrutturali<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">FCoE \u00e8 stato introdotto per risolvere questo problema tramite la convergenza della rete.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Invece di distribuire schede di rete Ethernet (NIC) e schede host Fibre Channel (HBA) separate all\u2019interno di ciascun server, le organizzazioni possono utilizzare un\u2019unica infrastruttura di rete convergente in grado di trasportare entrambi i tipi di traffico simultaneamente.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Questo approccio semplifica la distribuzione su larga scala nei data center, riducendo i costi operativi e migliorando l\u2019efficienza dell\u2019infrastruttura.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Il modo pi\u00f9 semplice per comprendere FCoE<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Il modo pi\u00f9 semplice per comprendere FCoE \u00e8:<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>FCoE consente al traffico di storage Fibre Channel di viaggiare attraverso reti Ethernet.<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">O, ancora pi\u00f9 semplicemente:<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>FCoE = traffico Fibre Channel incapsulato all\u2019interno di frame Ethernet<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">Una rete Fibre Channel tradizionale ha questo aspetto:<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>Server \u2192 Switch FC \u2192 Array di storage<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">Una rete FCoE ha questo aspetto:<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>Server \u2192 Switch Ethernet \u2192 Array di storage<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">In una distribuzione FCoE, la rete Ethernet diventa la piattaforma di trasporto condivisa sia per:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>il normale traffico di rete IP<\/p><\/li>\n\n\n\n<li><p>il traffico di storage aziendale<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Poich\u00e9 i carichi di lavoro di storage sono estremamente sensibili alla perdita di pacchetti e alla latenza, gli ambienti FCoE richiedono generalmente funzionalit\u00e0 Ethernet specializzate, quali:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Data Center Bridging (DCB)<\/p><\/li>\n\n\n\n<li><p>Controllo del flusso prioritario (PFC)<\/p><\/li>\n\n\n\n<li><p>Selezione avanzata della trasmissione (ETS)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Queste tecnologie contribuiscono a creare un ambiente Ethernet privo di perdite, in grado di supportare comunicazioni di storage di livello aziendale.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u2705 Come funziona FCoE in una rete di data center<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">FCoE funziona trasportando il traffico di storage Fibre Channel nativo attraverso reti Ethernet senza convertirlo in TCP\/IP. Invece di utilizzare switch Fibre Channel e cablaggi separati, FCoE incapsula i frame Fibre Channel all\u2019interno di frame Ethernet, consentendo al traffico LAN e SAN di condividere la stessa infrastruttura Ethernet ad alta velocit\u00e0.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/112d2f065da1443a812fea48088a3ae9-1024x576.jpg\" alt=\"How FCoE Works in a Data Center Network\" class=\"wp-image-7172\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/112d2f065da1443a812fea48088a3ae9-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/112d2f065da1443a812fea48088a3ae9-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/112d2f065da1443a812fea48088a3ae9-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/112d2f065da1443a812fea48088a3ae9-18x10.jpg 18w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/112d2f065da1443a812fea48088a3ae9.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Questo modello di rete convergente riduce la complessit\u00e0 hardware mantenendo la bassa latenza e l\u2019affidabilit\u00e0 richieste negli ambienti di storage aziendale.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Frame FC incapsulati in frame Ethernet<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La funzione principale di FCoE \u00e8 l\u2019incapsulamento dei frame Fibre Channel.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Il processo di trasmissione funziona come segue:<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>Frame Fibre Channel<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">A differenza di iSCSI o NVMe\/TCP, FCoE non converte il traffico di archiviazione in pacchetti TCP\/IP. Il protocollo Fibre Channel originale rimane inalterato durante il trasporto.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Protocollo<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Metodo di trasporto<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Fibre Channel<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fabric FC nativo<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>FCoE<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>FC su Ethernet<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>iSCSI<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SCSI su TCP\/IP<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>NVMe\/TCP<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>NVMe su TCP\/IP<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">CNA, switch e percorso di archiviazione<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un tipico deployment FCoE segue questo percorso:<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>Server \u2192 CNA \u2192 Switch Ethernet \u2192 Archiviazione<\/code><\/pre>\n\n\n\n<h4 class=\"wp-block-heading\">CNA (Adattatore di rete convergente)<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">La CNA combina:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Ethernet <a href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-nic-network-interface-card\/\" target=\"_blank\" rel=\"\">NIC<\/a> funzionalit\u00e0<\/p><\/li>\n\n\n\n<li><p>funzionalit\u00e0 HBA Fibre Channel<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ci\u00f2 consente a un singolo adattatore di gestire sia il traffico di rete che quello di archiviazione.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Switch abilitato FCoE<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Gli switch FCoE supportano tecnologie quali:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Data Center Bridging (DCB)<\/p><\/li>\n\n\n\n<li><p>Controllo del flusso prioritario (PFC)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Questi switch possono anche fungere da:<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>FCF (Fibre Channel Forwarder)<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">che gestisce i servizi Fibre Channel all\u2019interno della rete Ethernet.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Perch\u00e9 DCB \u00e8 richiesto per il trasporto senza perdite<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le reti Ethernet tradizionali sono \u201clossy\u201d, ovvero i pacchetti possono essere scartati in caso di congestione. Il traffico di archiviazione Fibre Channel, tuttavia, richiede un trasporto altamente affidabile e prevedibile.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Per supportare ci\u00f2, FCoE si basa su: Data Center Bridging (DCB)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">DCB potenzia Ethernet con funzionalit\u00e0 progettate per la trasmissione senza perdite.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le tecnologie chiave includono:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 220px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Funzionalit\u00e0 DCB<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Scopo<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>PFC<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Impedisce la perdita di frame<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>ETS<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Alloca la larghezza di banda<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>DCBX<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Scambia le impostazioni di configurazione<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Queste funzionalit\u00e0 aiutano Ethernet a comportarsi pi\u00f9 simile a una rete di archiviazione Fibre Channel.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Come FCoE abilita la rete convergente<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">I data center tradizionali richiedevano spesso connessioni separate per il traffico LAN e SAN:<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>Rete Ethernet + SAN Fibre Channel<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">FCoE consente a entrambi di operare sulla stessa infrastruttura Ethernet:<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>LAN + SAN su Ethernet<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">Ci\u00f2 riduce:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Cablaggio<\/p><\/li>\n\n\n\n<li><p>Numero di adattatori<\/p><\/li>\n\n\n\n<li><p>Complessit\u00e0 degli switch<\/p><\/li>\n\n\n\n<li><p>Consumo energetico<br><\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Moduli ottici Ethernet utilizzati per FCoE<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Poich\u00e9 FCoE opera sui livelli fisici Ethernet, utilizza transceiver ottici Ethernet standard anzich\u00e9 ottiche Fibre Channel native.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I moduli ottici FCoE pi\u00f9 comuni includono:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 221px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"221\"><p>Velocit\u00e0 Ethernet<br><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Moduli tipici<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"221\"><p>10G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SFP+ SR\/LR<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"221\"><p>25G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SFP28 SR\/LR<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"221\"><p>40G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/482749.htm\">QSFP+ SR4<\/a><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"221\"><p>100G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>QSFP28 SR4\/LR4<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Questi moduli trasportano sia il traffico Ethernet che il traffico di archiviazione Fibre Channel incapsulato attraverso la stessa infrastruttura di rete.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u2705 FCoE vs. Fibre Channel vs. Ethernet vs. iSCSI<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">FCoE, Fibre Channel, Ethernet e iSCSI sono tutti utilizzati negli ambienti enterprise di rete e storage, ma svolgono funzioni diverse e impiegano metodi di trasporto differenti.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La distinzione pi\u00f9 semplice \u00e8:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Fibre Channel (FC)<\/strong> \u00e8 un protocollo di rete di storage dedicato<\/p><\/li>\n\n\n\n<li><p><strong>FCoE<\/strong> trasporta il traffico Fibre Channel su Ethernet<\/p><\/li>\n\n\n\n<li><p><strong>Ethernet<\/strong> \u00e8 una tecnologia di rete a uso generale<\/p><\/li>\n\n\n\n<li><p><strong>iSCSI<\/strong> trasporta il traffico di storage su reti TCP\/IP<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Comprendere queste differenze aiuta le organizzazioni a scegliere l\u2019infrastruttura pi\u00f9 adatta in termini di prestazioni, scalabilit\u00e0 e costo.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8c515653ce394d13a830e5bf795a915f.jpg\" alt=\"FCoE vs. Fibre Channel vs. Ethernet vs. iSCSI\" class=\"wp-image-7173\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8c515653ce394d13a830e5bf795a915f.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8c515653ce394d13a830e5bf795a915f-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8c515653ce394d13a830e5bf795a915f-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8c515653ce394d13a830e5bf795a915f-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8c515653ce394d13a830e5bf795a915f-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">FCoE vs. Fibre Channel<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Il tradizionale Fibre Channel utilizza un\u2019infrastruttura SAN dedicata composta da:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>switch FC<\/p><\/li>\n\n\n\n<li><p>HBA FC<\/p><\/li>\n\n\n\n<li><p><a href=\"https:\/\/www.l-p.com\/products\/491877.htm\" target=\"_self\">moduli ottici FC<\/a><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">FCoE semplifica il deployment trasportando frame Fibre Channel su reti Ethernet anzich\u00e9 su fabric FC native.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 194px;\"\/><col style=\"width: 222px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"194\"><p>Caratteristica<\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"222\"><p>Fibre Channel<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>FCoE<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"194\"><p>Rete di trasporto<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"222\"><p>Fabric FC nativo<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Ethernet<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"194\"><p>Infrastruttura<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"222\"><p>SAN separata<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>LAN + SAN convergenti<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"194\"><p>Moduli ottici<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"222\"><p>Ottica FC<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Ottica Ethernet<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"194\"><p>Protocollo<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"222\"><p>FC nativo<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>FC incapsulato in Ethernet<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">FCoE preserva il protocollo Fibre Channel modificando per\u00f2 il livello di trasporto in Ethernet.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">FCoE vs. Ethernet<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ethernet \u00e8 progettato per la comunicazione dati generica, mentre FCoE \u00e8 ottimizzato per il traffico di storage.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A differenza dell\u2019Ethernet standard, FCoE richiede tecnologie di trasporto senza perdite quali:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Data Center Bridging (DCB)<\/p><\/li>\n\n\n\n<li><p>Controllo del flusso prioritario (PFC)<\/p><\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Caratteristica<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Ethernet<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>FCoE<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Scopo<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Networking generale<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Networking di storage<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Perdita di pacchetti<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Ammesso<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Controllato<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Tipo di trasporto<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Frame Ethernet<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>FC su Ethernet<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Richiede DCB<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>No<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Yes<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">In termini semplici:<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>FCoE utilizza l\u2019infrastruttura Ethernet per il networking di storage.<\/code><\/pre>\n\n\n\n<h3 class=\"wp-block-heading\">FCoE vs. iSCSI<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Sia FCoE che iSCSI trasportano il traffico di storage su Ethernet, ma utilizzano protocolli diversi.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>iSCSI<\/strong> utilizza TCP\/IP<\/p><\/li>\n\n\n\n<li><p><strong>FCoE<\/strong> preserva la comunicazione Fibre Channel nativa<\/p><\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Caratteristica<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>FCoE<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>iSCSI<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Protocollo<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibre Channel<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>TCP\/IP<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Trasporto<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>FC su Ethernet<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SCSI su TCP\/IP<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Tipo di rete<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Ethernet senza perdite<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Ethernet standard<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Latenza<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lower<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Maggiore<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Complessit\u00e0 di deployment<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Maggiore<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lower<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">iSCSI \u00e8 generalmente pi\u00f9 semplice e meno costoso da implementare, mentre FCoE \u00e8 comunemente utilizzato negli ambienti enterprise SAN che richiedono bassa latenza e integrazione con l\u2019infrastruttura Fibre Channel esistente.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Differenze nei moduli ottici<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le reti Fibre Channel tradizionali utilizzano moduli ottici FC dedicati quali:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>FC SFP+ 8G<\/p><\/li>\n\n\n\n<li><p>FC SFP+ 16G<\/p><\/li>\n\n\n\n<li><p>FC SFP28 32G<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Le reti FCoE utilizzano transceiver ottici Ethernet standard, tra cui:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>10G <a href=\"https:\/\/www.l-p.com\/products\/475415.htm\" target=\"_self\">SFP+ SR<\/a>\/LR<\/p><\/li>\n\n\n\n<li><p>SFP28 25G<\/p><\/li>\n\n\n\n<li><p>QSFP+ 40G<\/p><\/li>\n\n\n\n<li><p>Moduli ottici 100G QSFP28<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Poich\u00e9 FCoE opera sui livelli fisici Ethernet, sono richiesti moduli ottici Ethernet anzich\u00e9 ottiche Fibre Channel native.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u2705 Moduli ottici comuni utilizzati nelle reti FCoE<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Poich\u00e9 FCoE opera sui livelli fisici Ethernet, utilizza transceiver ottici Ethernet standard anzich\u00e9 ottiche Fibre Channel native. La scelta del modulo ottico dipende da fattori quali la velocit\u00e0 della rete, la distanza di trasmissione, la compatibilit\u00e0 con lo switch e l\u2019architettura del data center.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/150dcdba1f2c4ce5a772dd43a7328e33.jpg\" alt=\"Common Optical Modules Used in FCoE Networks\" class=\"wp-image-7174\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/150dcdba1f2c4ce5a772dd43a7328e33.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/150dcdba1f2c4ce5a772dd43a7328e33-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/150dcdba1f2c4ce5a772dd43a7328e33-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/150dcdba1f2c4ce5a772dd43a7328e33-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/150dcdba1f2c4ce5a772dd43a7328e33-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Nella maggior parte delle implementazioni, le reti FCoE privilegiano:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Basso ritardo<\/p><\/li>\n\n\n\n<li><p>Prestazioni stabili del collegamento<\/p><\/li>\n\n\n\n<li><p>Elevata interoperabilit\u00e0<\/p><\/li>\n\n\n\n<li><p>Compatibilit\u00e0 con gli switch enterprise<\/p><\/li>\n\n\n\n<li><p>Funzionamento affidabile di Ethernet senza perdite<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">I seguenti moduli ottici sono comunemente utilizzati negli ambienti FCoE moderni.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Moduli 10G SFP+ per implementazioni FCoE classiche<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019Ethernet 10G \u00e8 stata la piattaforma pi\u00f9 diffusa durante la fase iniziale di crescita di FCoE, in particolare nelle implementazioni enterprise basate su server blade e infrastrutture convergenti.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I moduli ottici FCoE 10G pi\u00f9 comuni includono:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Tipo di modulo<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Tipo di fibra<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Portata tipica<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/476059.htm\">10GBASE-SR<\/a> SFP+<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibra multimodale (OM3\/OM4)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fino a 300 m<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/475586.htm\">10GBASE-LR<\/a> SFP+<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibra monomodale (OS2)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fino a 10 km<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">I moduli 10G SFP+ sono comunemente utilizzati con:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Cisco UCS<\/p><\/li>\n\n\n\n<li><p>Ambienti VMware<\/p><\/li>\n\n\n\n<li><p>Convergenza SAN enterprise<\/p><\/li>\n\n\n\n<li><p><a href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/what-is-a-tor-top-of-rack-switch\/\" target=\"_blank\" rel=\"\">Top-of-rack<\/a> Commutazione ToR (Top-of-Rack)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Per connessioni brevi all\u2019interno dello stesso rack, molte implementazioni utilizzano anche:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Cavi DAC 10G<\/p><\/li>\n\n\n\n<li><p>Cavi AOC 10G<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">per ridurre costi e consumo energetico.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Moduli 25G SFP28 per reti convergenti pi\u00f9 recenti<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Con l\u2019aumento dei requisiti di larghezza di banda nei data center, molte organizzazioni hanno migrato dall\u2019Ethernet 10G a quella 25G.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I moduli 25G SFP28 offrono:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Larghezza di banda superiore<\/p><\/li>\n\n\n\n<li><p>Maggiore efficienza per lane<\/p><\/li>\n\n\n\n<li><p>Costo inferiore per gigabit<\/p><\/li>\n\n\n\n<li><p>Migliorata scalabilit\u00e0<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Le opzioni pi\u00f9 comuni includono:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Tipo di modulo<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Tipo di fibra<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Portata tipica<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/473141.htm\">25GBASE-SR<\/a> SFP28<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibra multimodale<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fino a 100 m<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/476046.htm\">25GBASE-LR<\/a> SFP28<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibra monomodale<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fino a 10 km<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Le implementazioni FCoE 25G sono comuni in:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Data center enterprise moderni<\/p><\/li>\n\n\n\n<li><p>Reti di storage virtualizzate<\/p><\/li>\n\n\n\n<li><p>Ambienti server ad alta densit\u00e0<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Moduli 40G QSFP+ per collegamenti ad alta densit\u00e0<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">I moduli 40G QSFP+ sono spesso utilizzati per aggregazione e collegamenti uplink tra switch nelle infrastrutture FCoE convergenti.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I moduli tipici includono:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Tipo di modulo<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Tipo di fibra<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Portata tipica<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/482750.htm\">40GBASE-SR4<\/a> QSFP+<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibra multimodale<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fino a 150 m<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/482487.htm\">40GBASE-LR4<br><\/a> QSFP+<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibra monomodale<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fino a 10 km<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Questi moduli vengono comunemente impiegati in:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>architetture spine-leaf<\/p><\/li>\n\n\n\n<li><p>Livelli di aggregazione<\/p><\/li>\n\n\n\n<li><p>Interconnessioni tra switch ad alta densit\u00e0<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">I collegamenti 40G possono consolidare pi\u00f9 connessioni server a bassa velocit\u00e0 in un numero minore di uplink ad alta larghezza di banda.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Moduli 100G QSFP28 per i backbone dei data center moderni<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019Ethernet 100G viene sempre pi\u00f9 utilizzata nelle infrastrutture convergenti su larga scala e nei backbone dei data center moderni.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I moduli ottici FCoE 100G pi\u00f9 comuni includono:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Tipo di modulo<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Tipo di fibra<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Portata tipica<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/473115.htm\">100GBASE-SR4<\/a> QSFP28<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibra multimodale<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fino a 100 m<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/488423.htm\">100GBASE-LR4<br><\/a> QSFP28<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibra monomodale<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fino a 10 km<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">I moduli 100G QSFP28 sono ideali per:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Commutazione centrale nel data center<\/p><\/li>\n\n\n\n<li><p>Reti di storage ad alte prestazioni<\/p><\/li>\n\n\n\n<li><p>Infrastruttura su scala cloud<\/p><\/li>\n\n\n\n<li><p>Grandi cluster di virtualizzazione<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Questi collegamenti a velocit\u00e0 pi\u00f9 elevata aiutano a supportare l\u2019aumento dei volumi di traffico di storage riducendo contemporaneamente i requisiti complessivi di densit\u00e0 delle porte.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Opzioni DAC e AOC per collegamenti a breve distanza<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">In molti deployment FCoE, specialmente all\u2019interno di un rack o tra rack adiacenti, le soluzioni DAC e AOC sono spesso pi\u00f9 convenienti dal punto di vista economico rispetto ai tradizionali trasceivers ottici.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">DAC (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/what-is-breakout-dac-and-why-breakout-dac-matters\/\">Rame ad attacco diretto<\/a>)<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">I cavi DAC sono cavi in rame passivi o attivi con connettori integrati.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I vantaggi includono:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Costo inferiore<\/p><\/li>\n\n\n\n<li><p>Latenza molto bassa<br><\/p><\/li>\n\n\n\n<li><p>Riduzione del consumo energetico<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Applicazioni tipiche:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Collegamenti da server a switch<\/p><\/li>\n\n\n\n<li><p>Collegamenti brevi top-of-rack<\/p><\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">AOC (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/aoc-explained-active-optical-cable-benefits-uses-advancements-guide\/\">cavo ottico attivo<\/a>)<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Gli AOC combinano fibra ottica con tecnologia di trasceiver integrata.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I vantaggi includono:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Maggiore portata rispetto ai DAC<\/p><\/li>\n\n\n\n<li><p>Minore peso del cavo<\/p><\/li>\n\n\n\n<li><p>Maggiore <a href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-electromagnetic-interference\/\" target=\"_blank\" rel=\"\">EMI<\/a> resistenza<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Applicazioni tipiche:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Collegamenti tra rack<\/p><\/li>\n\n\n\n<li><p>Collegamenti ad alta velocit\u00e0 a media distanza<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Scelta del modulo ottico appropriato per FCoE<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Nella selezione di moduli ottici per reti FCoE, i fattori da considerare con attenzione includono:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 309px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"309\"><p>Fattore di selezione<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Importanza<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"309\"><p>Compatibilit\u00e0 dello switch<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Garantisce l\u2019interoperabilit\u00e0<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"309\"><p>Distanza di trasmissione<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Determina il tipo di modulo<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"309\"><p>Velocit\u00e0 della rete<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Corrisponde ai requisiti di larghezza di banda<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"309\"><p>Tipo di fibra<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/smf-optical-transceiver-vs-mmf-optical-transceiver-guide\/\">MMF vs. SMF<\/a><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"309\"><p>Latenza e stabilit\u00e0<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fondamentale per il traffico di storage<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"309\"><p>Supporto dell\u2019ambiente DCB<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Necessario per un funzionamento FCoE affidabile<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Poich\u00e9 gli ambienti FCoE sono estremamente sensibili all'affidabilit\u00e0 della rete, si preferiscono generalmente trasceivers ottici Ethernet enterprise-grade con prestazioni stabili e ampia compatibilit\u00e0 con gli switch.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u2705 Requisiti chiave per le prestazioni e la stabilit\u00e0 FCoE<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Gli ambienti FCoE sono pi\u00f9 sensibili alla qualit\u00e0 della rete rispetto alle reti Ethernet standard, poich\u00e9 il traffico di storage richiede una latenza prevedibile, una consegna affidabile e un funzionamento stabile a lungo termine. Sebbene FCoE utilizzi l\u2019infrastruttura Ethernet, i deployment enterprise richiedono generalmente standard pi\u00f9 elevati per la configurazione degli switch, la qualit\u00e0 dei moduli ottici e l\u2019interoperabilit\u00e0 complessiva della rete.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e30060e2a49b4c7d94e0e3b8ae8d333f.jpg\" alt=\"Key Requirements for FCoE Performance and Stability\" class=\"wp-image-7175\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e30060e2a49b4c7d94e0e3b8ae8d333f.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e30060e2a49b4c7d94e0e3b8ae8d333f-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e30060e2a49b4c7d94e0e3b8ae8d333f-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e30060e2a49b4c7d94e0e3b8ae8d333f-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e30060e2a49b4c7d94e0e3b8ae8d333f-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Per mantenere prestazioni FCoE stabili, le organizzazioni devono concentrarsi su diversi fattori critici di deployment.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">DCB ed Ethernet senza perdite<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Uno dei requisiti pi\u00f9 importanti per FCoE \u00e8: Ethernet senza perdite<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le reti Ethernet tradizionali consentono la perdita di pacchetti durante la congestione, ma il traffico di storage Fibre Channel \u00e8 progettato per un trasporto altamente affidabile.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Per supportare questo comportamento, FCoE si basa su: Data Center Bridging (DCB)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">DCB \u00e8 un insieme di miglioramenti apportati all\u2019Ethernet che contribuiscono a creare un ambiente pi\u00f9 prevedibile e privo di perdite.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le principali tecnologie DCB includono:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 350px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"350\"><p>Tecnologia<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Funzione<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"350\"><p>Controllo del flusso prioritario (PFC)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Impedisce la perdita di frame durante la congestione<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"350\"><p>Selezione avanzata della trasmissione (ETS)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Alloca la larghezza di banda tra le classi di traffico<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"350\"><p>DCBX<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Scambia informazioni sulla configurazione DCB<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Senza una configurazione DCB adeguata, il traffico di storage FCoE potrebbe subire instabilit\u00e0, problemi di congestione o perdita di pacchetti.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Bassa latenza e basso tasso di errore<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Il traffico di storage \u00e8 altamente sensibile alle variazioni di latenza e agli errori di trasmissione.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Per un funzionamento stabile di FCoE, le reti devono mantenere:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Basso ritardo<\/p><\/li>\n\n\n\n<li><p>Basso jitter<\/p><\/li>\n\n\n\n<li><p>Bassa <a href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/understanding-what-is-bit-error-rate\/\" target=\"_blank\" rel=\"\">il tasso di errore su bit<\/a> (BER)<\/p><\/li>\n\n\n\n<li><p>Qualit\u00e0 stabile del segnale ottico<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Collegamenti di scarsa qualit\u00e0 possono causare:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Ritrasmissioni di frame<\/p><\/li>\n\n\n\n<li><p>Degradazione delle prestazioni<\/p><\/li>\n\n\n\n<li><p>Interruzioni nell\u2019accesso allo storage<\/p><\/li>\n\n\n\n<li><p>Instabilit\u00e0 del link<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Per questo motivo, i deployment enterprise di FCoE privilegiano tipicamente moduli ottici Ethernet di alta qualit\u00e0 e infrastrutture cablate affidabili.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Compatibilit\u00e0 dello switch<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">FCoE richiede switch Ethernet che supportino:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>DCB<\/p><\/li>\n\n\n\n<li><p>PFC<\/p><\/li>\n\n\n\n<li><p>Funzionalit\u00e0 di inoltro FCoE<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Le piattaforme enterprise pi\u00f9 comuni includono:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Cisco Nexus<\/p><\/li>\n\n\n\n<li><p>Dell EMC<\/p><\/li>\n\n\n\n<li><p>Brocade<\/p><\/li>\n\n\n\n<li><p>HPE<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">La compatibilit\u00e0 \u00e8 particolarmente importante perch\u00e9 alcuni switch applicano politiche rigorose di convalida dei transceiver tramite controlli EEPROM e requisiti di codifica del produttore.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In molti ambienti di produzione, l\u2019uso di moduli ottici non supportati pu\u00f2 provocare:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Messaggi di avviso<\/p><\/li>\n\n\n\n<li><p>Malfunzionamenti della connessione<\/p><\/li>\n\n\n\n<li><p>Riduzione della stabilit\u00e0<\/p><\/li>\n\n\n\n<li><p>Disattivazione delle funzioni di monitoraggio<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Interoperabilit\u00e0 dei moduli e certificazione del produttore<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Sebbene FCoE utilizzi transceiver ottici Ethernet standard, l\u2019interoperabilit\u00e0 rimane fondamentale nelle reti enterprise di storage.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nella scelta dei moduli ottici per i deployment FCoE, le organizzazioni valutano tipicamente:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 331px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"331\"><p>Requisito<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Importanza<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"331\"><p>Compatibilit\u00e0 del fornitore<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Garantisce il riconoscimento da parte dello switch<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"331\"><p>Monitoraggio DOM\/DDM stabile<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Supporta la risoluzione dei problemi<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"331\"><p>Prestazioni di basso BER<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Migliora l'affidabilit\u00e0 dello storage<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"331\"><p>Stabilit\u00e0 termica<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Supporta il funzionamento a lungo termine<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"331\"><p>Qualifica enterprise<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Riduce il rischio di deployment<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Per questo motivo, molti data center preferiscono:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a href=\"https:\/\/www.l-p.com\/products\/475753.htm\" target=\"_self\">Moduli compatibili Cisco<\/a><\/p><\/li>\n\n\n\n<li><p><a href=\"https:\/\/www.l-p.com\/products\/475779.htm\" target=\"_self\">Moduli compatibili Dell<\/a><\/p><\/li>\n\n\n\n<li><p><a href=\"https:\/\/www.l-p.com\/products\/476749.htm\" target=\"_self\">Moduli compatibili Brocade<\/a><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">invece di transceiver generici non certificati.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Negli ambienti FCoE, l\u2019interoperabilit\u00e0 stabile \u00e8 spesso pi\u00f9 importante del semplice raggiungimento della connettivit\u00e0 del collegamento.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u2705 FAQ su FCoE (Fibre Channel over Ethernet)<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/77b2894c0f654dff8689be0ee0b65d46.jpg\" alt=\"FAQ About FCoE Fibre Channel over Ethernet\" class=\"wp-image-7176\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/77b2894c0f654dff8689be0ee0b65d46.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/77b2894c0f654dff8689be0ee0b65d46-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/77b2894c0f654dff8689be0ee0b65d46-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/77b2894c0f654dff8689be0ee0b65d46-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/77b2894c0f654dff8689be0ee0b65d46-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">FCoE \u00e8 ancora utilizzato oggi?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00ec. FCoE \u00e8 ancora utilizzato in molti data center aziendali, in particolare negli ambienti che si basano gi\u00e0 sull\u2019infrastruttura SAN Fibre Channel e sulle architetture di rete convergente.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sebbene tecnologie pi\u00f9 recenti come NVMe\/TCP e <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/rdma-over-converged-ethernet-fast-low-latency-data-transfer\/\">RoCE<\/a> stiano diventando sempre pi\u00f9 comuni negli ambienti cloud e iperscalabili, FCoE rimane rilevante per:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Reti di storage enterprise<\/p><\/li>\n\n\n\n<li><p>distribuzioni Cisco UCS<\/p><\/li>\n\n\n\n<li><p>data center virtualizzati<\/p><\/li>\n\n\n\n<li><p>infrastrutture LAN e SAN convergenti<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">FCoE richiede moduli ottici speciali?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No. FCoE utilizza tipicamente moduli ottici Ethernet standard anzich\u00e9 ottiche Fibre Channel dedicate.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I transceiver ottici FCoE pi\u00f9 comuni includono:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>10G SFP+ SR\/LR<\/p><\/li>\n\n\n\n<li><p>25G SFP28 SR\/LR<\/p><\/li>\n\n\n\n<li><p>QSFP+ 40G<\/p><\/li>\n\n\n\n<li><p>Moduli ottici 100G QSFP28<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Tuttavia, gli ambienti enterprise FCoE richiedono spesso:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>maggiore compatibilit\u00e0 con gli switch<\/p><\/li>\n\n\n\n<li><p>tassi di errore inferiori<\/p><\/li>\n\n\n\n<li><p>funzionamento stabile di DCB<\/p><\/li>\n\n\n\n<li><p>interoperabilit\u00e0 affidabile<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Pertanto, sono generalmente preferiti i moduli ottici Ethernet di livello enterprise.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">FCoE \u00e8 la stessa cosa di Fibre Channel?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No. FCoE e Fibre Channel sono tecnologie strettamente correlate, ma non identiche.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Il tradizionale Fibre Channel utilizza un\u2019infrastruttura SAN FC dedicata, mentre FCoE trasporta il traffico Fibre Channel attraverso reti Ethernet.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La differenza fondamentale \u00e8:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Tecnologia<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Rete di trasporto<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Fibre Channel<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fabric FC nativo<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>FCoE<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Ethernet<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">FCoE preserva il protocollo Fibre Channel nativo modificando solo il livello fisico di trasporto in Ethernet.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Gli switch Ethernet standard possono supportare FCoE?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Non sempre.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">FCoE richiede switch Ethernet che supportino:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Data Center Bridging (DCB)<\/p><\/li>\n\n\n\n<li><p>Controllo del flusso prioritario (PFC)<\/p><\/li>\n\n\n\n<li><p>funzionalit\u00e0 di inoltro FCoE<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Gli switch Ethernet standard non gestiti non supportano tipicamente queste funzionalit\u00e0.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Gli switch enterprise comunemente utilizzati per FCoE includono:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Cisco Nexus<\/p><\/li>\n\n\n\n<li><p>switch Dell EMC<\/p><\/li>\n\n\n\n<li><p>switch data center Brocade<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Queste piattaforme sono progettate per supportare l\u2019ambiente Ethernet senza perdite necessario per un traffico di storage FCoE stabile.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u2705 Quando utilizzare il protocollo FCoE<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">FCoE \u00e8 stato sviluppato per semplificare le reti di storage aziendali integrando il traffico SAN Fibre Channel e il traffico LAN Ethernet in un\u2019unica infrastruttura convergente. Sebbene le nuove tecnologie di storage basate su Ethernet continuino a evolversi, FCoE rimane ancora valido in specifici ambienti aziendali in cui sono fondamentali bassa latenza, affidabilit\u00e0 dello storage e integrazione con la SAN.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0311b7ab9ce3430c933a1a711a295c1e.jpg\" alt=\"When to Use FCoE Protocol\" class=\"wp-image-7177\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0311b7ab9ce3430c933a1a711a295c1e.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0311b7ab9ce3430c933a1a711a295c1e-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0311b7ab9ce3430c933a1a711a295c1e-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0311b7ab9ce3430c933a1a711a295c1e-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0311b7ab9ce3430c933a1a711a295c1e-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">La scelta migliore per la distribuzione dipende da fattori quali l\u2019infrastruttura esistente, i requisiti di scalabilit\u00e0, la complessit\u00e0 operativa e la strategia a lungo termine del data center.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Scenari di applicazione ottimale per FCoE<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">FCoE \u00e8 particolarmente adatto alle organizzazioni che gi\u00e0 gestiscono ambienti di storage Fibre Channel ma desiderano ridurre la complessit\u00e0 dell\u2019infrastruttura e il sovraccarico dei cablaggi.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I tipici scenari di distribuzione FCoE includono:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Data center aziendali con infrastruttura SAN FC esistente<\/p><\/li>\n\n\n\n<li><p>Ambienti di rete convergente Cisco UCS<\/p><\/li>\n\n\n\n<li><p>Cluster di server virtualizzati<\/p><\/li>\n\n\n\n<li><p>Architetture di server blade<\/p><\/li>\n\n\n\n<li><p>Deployments rack ad alta densit\u00e0<\/p><\/li>\n\n\n\n<li><p>Organizzazioni che migrano dall\u2019FC tradizionale verso infrastrutture basate su Ethernet<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">FCoE risulta particolarmente utile quando le aziende vogliono preservare le prestazioni dello storage Fibre Channel semplificando al contempo il deployment fisico della rete.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I suoi principali vantaggi includono:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Riduzione dei cavi<\/p><\/li>\n\n\n\n<li><p>Minor numero di adattatori e porte di switch<\/p><\/li>\n\n\n\n<li><p>Una gestione semplificata dell\u2019infrastruttura<\/p><\/li>\n\n\n\n<li><p>Minori requisiti di alimentazione e raffreddamento<\/p><\/li>\n\n\n\n<li><p>Connettivit\u00e0 ottica Ethernet condivisa<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Poich\u00e9 FCoE opera sui livelli fisici Ethernet, le organizzazioni possono inoltre sfruttare transceiver ottici Ethernet standard come:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a href=\"https:\/\/www.l-p.com\/products\/477539.htm\" target=\"_self\">SFP+ da 10G LINK-PP<\/a><\/p><\/li>\n\n\n\n<li><p><a href=\"https:\/\/www.l-p.com\/products\/491478.htm\" target=\"_self\">Moduli 25G SFP28<\/a><\/p><\/li>\n\n\n\n<li><p><a href=\"https:\/\/www.l-p.com\/products\/491484.htm\" target=\"_self\">Moduli QSFP+<\/a><\/p><\/li>\n\n\n\n<li><p><a href=\"https:\/\/www.l-p.com\/products\/472118.htm\" target=\"_self\">Moduli QSFP28<\/a><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">per le implementazioni di reti convergenti.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Quando Fibre Channel \u00e8 ancora la scelta pi\u00f9 indicata<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Fibre Channel tradizionale rimane una solida opzione per ambienti SAN aziendali altamente specializzati che privilegiano massima stabilit\u00e0, prestazioni deterministiche e consolidate pratiche operative.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le SAN native FC sono ancora comunemente utilizzate in:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Reti di storage aziendali di grandi dimensioni<\/p><\/li>\n\n\n\n<li><p>Sistemi di database mission-critical<\/p><\/li>\n\n\n\n<li><p>Istituzioni finanziarie<\/p><\/li>\n\n\n\n<li><p>Ambienti SAN legacy<\/p><\/li>\n\n\n\n<li><p>Reti di storage ad alte prestazioni<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">I vantaggi di Fibre Channel tradizionale includono:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Un ecosistema SAN maturo<\/p><\/li>\n\n\n\n<li><p>Isolamento dedicato dello storage<\/p><\/li>\n\n\n\n<li><p>Prestazioni estremamente prevedibili<\/p><\/li>\n\n\n\n<li><p>Affidabilit\u00e0 a lungo termine comprovata<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Tuttavia, l\u2019infrastruttura FC richiede tipicamente:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Switch FC separati<\/p><\/li>\n\n\n\n<li><p>Moduli ottici FC dedicati<\/p><\/li>\n\n\n\n<li><p>Cablaggio SAN indipendente<\/p><\/li>\n\n\n\n<li><p>Maggiore complessit\u00e0 di implementazione<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Per le organizzazioni fortemente investite nelle esistenti architetture Fibre Channel, proseguire con FC nativo pu\u00f2 ancora rappresentare l\u2019opzione pi\u00f9 pratica.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Quando iSCSI o NVMe\/TCP potrebbero essere una scelta migliore<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">In molti ambienti cloud e hyperscale moderni, le organizzazioni scelgono sempre pi\u00f9 protocolli di storage basati su IP, quali:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>iSCSI<\/p><\/li>\n\n\n\n<li><p>NVMe\/TCP<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">invece di FCoE.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Questi protocolli sono spesso preferiti perch\u00e9:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Operano su reti Ethernet standard<\/p><\/li>\n\n\n\n<li><p>Richiedono una configurazione meno specializzata<\/p><\/li>\n\n\n\n<li><p>Semplificano l\u2019implementazione su larga scala<\/p><\/li>\n\n\n\n<li><p>Si integrano facilmente con l\u2019infrastruttura cloud<\/p><\/li>\n\n\n\n<li><p>Riducono la complessit\u00e0 operativa<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">iSCSI \u00e8 comunemente scelto per:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Storage per piccole e medie imprese<\/p><\/li>\n\n\n\n<li><p>Deployments sensibili ai costi<\/p><\/li>\n\n\n\n<li><p>Virtualizzazione generica<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">NVMe\/TCP sta diventando sempre pi\u00f9 importante per:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Storage flash ad alta velocit\u00e0<\/p><\/li>\n\n\n\n<li><p>Infrastrutture per l\u2019intelligenza artificiale<\/p><\/li>\n\n\n\n<li><p>Data center moderni software-defined<\/p><\/li>\n\n\n\n<li><p>Architetture cloud scalabili<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Rispetto a FCoE, queste tecnologie offrono generalmente modelli di implementazione pi\u00f9 semplici e un\u2019adozione pi\u00f9 ampia nell\u2019ecosistema in ambienti pi\u00f9 recenti.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Considerazioni finali<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">FCoE rimane una tecnologia importante nell\u2019evoluzione delle reti data center convergenti. Esso colma il divario tra l\u2019infrastruttura SAN Fibre Channel tradizionale e le moderne architetture basate su Ethernet, consentendo al traffico di storage e al traffico di rete di condividere lo stesso ambiente fisico Ethernet.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sebbene le nuove tecnologie di networking per lo storage continuino a diffondersi, FCoE offre ancora un valore reale negli ambienti aziendali che richiedono:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Compatibilit\u00e0 con Fibre Channel<\/p><\/li>\n\n\n\n<li><p>Networking convergente<\/p><\/li>\n\n\n\n<li><p>Comunicazione di storage a bassa latenza<\/p><\/li>\n\n\n\n<li><p>Implementazione semplificata dell\u2019infrastruttura<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Per un funzionamento stabile di FCoE, la selezione di transceiver ottici Ethernet affidabili e di hardware di rete compatibile \u00e8 fondamentale.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Se state realizzando o aggiornando una rete di storage Ethernet convergente, il <a target=\"\" rel=\"\" href=\"https:\/\/www.l-p.com\/\">Negozio ufficiale LINK-PP<\/a> offre transceiver ottici di livello enterprise, soluzioni DAC\/AOC e prodotti per la connettivit\u00e0 ad alta velocit\u00e0 progettati per gli ambienti moderni di data center e di networking FCoE.<\/p>","protected":false},"excerpt":{"rendered":"<p>Scopri cos\u2019\u00e8 FCoE (Fibre Channel over Ethernet), come funziona e come si relaziona con i moduli ottici, DCB e le reti data center ad alte prestazioni.<\/p>","protected":false},"author":1,"featured_media":7178,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[27],"tags":[13,14,16,18,26],"class_list":["post-7179","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-glossary","tag-100g-modules","tag-10g-sfp-transceivers","tag-link-pp-25g-sfp28-optical-modules","tag-40g-qsfp-transceivers","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/7179","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/comments?post=7179"}],"version-history":[{"count":5,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/7179\/revisions"}],"predecessor-version":[{"id":10698,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/7179\/revisions\/10698"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media\/7178"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media?parent=7179"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/categories?post=7179"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/tags?post=7179"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}