{"id":5938,"date":"2025-06-16T00:00:00","date_gmt":"2025-06-16T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/cwdm-vs-dwdm-differences-channel-capacity-distance-cost\/"},"modified":"2026-06-22T09:27:35","modified_gmt":"2026-06-22T09:27:35","slug":"cwdm-vs-dwdm-differences-channel-capacity-distance-cost","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/cwdm-vs-dwdm-differences-channel-capacity-distance-cost","title":{"rendered":"Qual \u00e8 la differenza tra CWDM e DWDM?"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ec7c0b712c0d41d28bc4498741296e64.webp\" alt=\"CWDM vs DWDM\" class=\"wp-image-5936\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ec7c0b712c0d41d28bc4498741296e64.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ec7c0b712c0d41d28bc4498741296e64-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ec7c0b712c0d41d28bc4498741296e64-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ec7c0b712c0d41d28bc4498741296e64-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ec7c0b712c0d41d28bc4498741296e64-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Multiplexing a divisione d'onda (<\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/wdm-optical-transceiver-module-applications\/\"><strong>WDM<\/strong><\/a><strong>)<\/strong> ha rivoluzionato le fibre ottiche abilitando pi\u00f9 flussi di dati a viaggiare simultaneamente su una singola fibra. Due varianti dominanti\u2014<strong>CWDM (Multiplexing a divisione di lunghezza d\u2019onda grossolana) <\/strong>and <strong>DWDM (Multiplexing a divisione di lunghezza d\u2019onda densa)<\/strong>\u2014alimentano le reti moderne. La differenza principale tra CWDM e DWDM risiede nella capacit\u00e0 dei canali, nella velocit\u00e0 dei dati e nella portata. Entrambi utilizzano la multiplexing a divisione di lunghezza d\u2019onda, ma CWDM e DWDM offrono caratteristiche distinte. La tabella sottostante confronta le specifiche chiave della multiplexing a divisione di lunghezza d\u2019onda, come lo spaziamento dei canali e l\u2019amplificazione, utilizzando prodotti come <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/483258.htm\">LINK-PP LS-CW5310-20C<\/a> and <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/488746.htm\">LINK-PP LS-DW3210-40I<\/a> Moduli ottici.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Caratteristica<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>CWDM<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>DWDM<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Spaziatura dei canali<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>20 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>0,8 nm (100 GHz), 0,4 nm (50 GHz)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Numero di canali<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fino a 18<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>40\u2013160<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Distanza di trasmissione<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>tratti brevi a medi<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>trasmissione su lunga distanza<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Laser di modulazione<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>DFB non refrigerato<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>EML refrigerato\/tunable<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Consumo energetico<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>0,5 W per modulo<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 W per modulo<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Capacit\u00e0 di amplificazione<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>No<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Yes<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >Punti chiave<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>CWDM<\/strong> offre una soluzione economica e semplice per distanze brevi o medie con esigenze moderate di dati, rendendola ideale per reti metropolitane e aziendali.<\/p><\/li><li><p><strong>DWDM<\/strong> supporta una capacit\u00e0 di dati molto pi\u00f9 elevata e distanze maggiori, utilizzando tecnologie avanzate adatte a reti di backbone e a lunga distanza che richiedono scalabilit\u00e0 e alte prestazioni.<\/p><\/li><li><p>La scelta tra CWDM e DWDM dipende dalla distanza della vostra rete, dai requisiti di capacit\u00e0, dal budget e dai piani di crescita futura, per garantire la migliore corrispondenza e il massimo valore.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >CWDM vs DWDM<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/980ea5a903da45debe19da9ef0ef606c.webp\" alt=\"CWDM vs DWDM\" class=\"wp-image-5937\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/980ea5a903da45debe19da9ef0ef606c.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/980ea5a903da45debe19da9ef0ef606c-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/980ea5a903da45debe19da9ef0ef606c-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/980ea5a903da45debe19da9ef0ef606c-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/980ea5a903da45debe19da9ef0ef606c-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Spaziatura dei canali e capacit\u00e0 in lunghezza d\u2019onda<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>CWDM<\/strong>: Utilizza <strong>spaziatura di 20 nm<\/strong> su uno spettro ampio (1270\u20131610 nm), supportando fino a <strong>18 canali<\/strong>. Questa spaziatura ampia consente l\u2019uso di laser non refrigerati e filtri pi\u00f9 semplici, riducendo notevolmente i costi.<\/p><\/li><li><p style=\"margin: 0px;\"><span class=\"qc-p1-tag\"><strong>DWDM<\/strong>: Impiega una spaziatura estremamente stretta di <strong>0,8\/0,4 nm<\/strong> (griglia da 100 GHz\/50 GHz) nelle bande C (1525\u20131565 nm) e L (1570\u20131610 nm), consentendo fino a <strong>40\u2013160+ canali<\/strong> per fibra. I laser refrigerati di precisione garantiscono stabilit\u00e0 della lunghezza d\u2019onda per un traffico ad alta densit\u00e0.<\/span><\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Distanza e amplificazione del segnale<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"text-align: left;\"><strong>CWDM<\/strong> \u00e8 ideale per <strong>tratti brevi a medi<\/strong> (fino a circa 70\u201380 km), ma normalmente non pu\u00f2 essere amplificato otticamente a causa della spaziatura ampia.<\/p><\/li><li><p style=\"text-align: left;\"><strong>DWDM<\/strong>, invece, \u00e8 progettato per<strong> La DCF opera fornendo un elevato coefficiente di dispersione negativa che controbilancia la dispersione positiva generata dalla fibra standard di trasmissione. L\u2019obiettivo non \u00e8 semplicemente ridurre la dispersione, ma bilanciare la dispersione totale del collegamento a un livello ottimale per la trasmissione del segnale.<\/strong> trasmissioni a lunga distanza (centinaia o migliaia di chilometri) e supporta l\u2019amplificazione ottica, ad esempio mediante EDFA, nella banda C. <\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Costo ed efficienza energetica<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Il costo \u00e8 un fattore fondamentale nella progettazione di una rete. Le differenze di progettazione e prestazioni tra CWDM e DWDM determinano variazioni significative sia nei costi iniziali che in quelli operativi.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Aspetto<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>CWDM<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>DWDM<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Investimento iniziale<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Pi\u00f9 basso; adatto a reti pi\u00f9 piccole<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Pi\u00f9 alto; adatto a reti su larga scala<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Costi operativi<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Pi\u00f9 bassi; manutenzione e alimentazione pi\u00f9 semplici<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Pi\u00f9 alti; gestione e alimentazione pi\u00f9 complesse<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Complessit\u00e0 dell\u2019equipaggiamento<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Componenti semplici e passivi<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Componenti complessi e attivi<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Il CWDM offre una soluzione economicamente vantaggiosa per espandere la larghezza di banda senza posare nuove fibre. I suoi transceiver e i multiplexer sono meno costosi e il sistema consuma meno energia. Il DWDM richiede un investimento iniziale maggiore a causa dell\u2019equipaggiamento specializzato e dei requisiti di controllo pi\u00f9 stringenti, ma garantisce una capacit\u00e0 e una scalabilit\u00e0 molto superiori.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px 0px 4px;\"><strong>I sistemi CWDM costano circa 50% in meno<\/strong> rispetto al DWDM. I principali risparmi derivano da:<\/p><ul><li><p style=\"margin: 0px;\">Laser non controllati termicamente (0,5 W contro i 4 W del DWDM)<\/p><\/li><li><p style=\"margin: 0px;\">Filtri e unit\u00e0 mux\/demux con tolleranze inferiori.<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px;\"><strong>Il prezzo premium del DWDM<\/strong> riflette la sua ottica complessa, gli amplificatori EDFA e i compensatori di dispersione per portate ultra-lunghe.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Complessit\u00e0<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La complessit\u00e0 influisce sull\u2019installazione, sulla gestione e sul funzionamento a lungo termine. CWDM e DWDM differiscono notevolmente in questo ambito.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>CWDM<\/strong> utilizza componenti passivi e laser non refrigerati, con conseguente minore complessit\u00e0. L\u2019installazione e la manutenzione sono semplici e il sistema richiede meno energia e controllo ambientale.<\/p><\/li><li><p><strong>DWDM<\/strong> prevede un hardware pi\u00f9 complesso, inclusi laser refrigerati e una gestione precisa della temperatura. La stretta spaziatura tra i canali richiede una configurazione accurata e un monitoraggio continuo. I sistemi DWDM richiedono inoltre competenze specializzate per l\u2019installazione e la risoluzione dei problemi.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">La semplicit\u00e0 del CWDM lo rende attraente per le organizzazioni che cercano un\u2019implementazione agevole e un ridotto carico operativo. La complessit\u00e0 del DWDM \u00e8 giustificata dalla sua capacit\u00e0 di fornire elevate prestazioni e supporto per trasmissioni ad alta capacit\u00e0 su lunghe distanze.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Applicazioni<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>CWDM ideale per:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Reti aziendali\/campus<\/strong>: Collegamento di edifici distanti fino a 40 km.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Aggiornamenti orientati al costo<\/strong>: Aggiunta di 4\u20138 canali senza sostituire la fibra.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Internet delle cose industriale (IIoT)<br><\/strong>: Ambienti robusti non controllati termicamente (ad es. pavimenti di fabbrica).<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>DWDM Dominante:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Reti di backbone per telecomunicazioni<\/strong>: Tratte a lunga distanza tra citt\u00e0.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Data center iperscalabili<\/strong>: Interconnessioni 400G+ tra campus.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fronthaul \/ backhaul 5G<\/strong>: Aggregazione ad alta densit\u00e0 per unit\u00e0 di banda base.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Sommario<\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 240px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"240\"><p>Caratteristica<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>CWDM<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>DWDM<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"240\"><p>Spaziatura dei canali<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~20\u202fnm (grossolana)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~0,8\u202fnm (densa)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"240\"><p>Numero massimo di canali<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fino a ~18<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>40\u201396+<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"240\"><p>Distanza<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fino a ~70\u201380\u202fkm, senza amplificazione<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Centinaia o migliaia di km con amplificazione<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"240\"><p>Costo ed energia<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Costo inferiore, laser e filtri non refrigerati<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Costo superiore, richiede refrigerazione e amplificatori<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"240\"><p>Casi d\u2019uso ideali<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Reti metropolitane\/accesso, esigenze di basso numero di canali<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Reti core\/backbone, collegamenti ad alta velocit\u00e0 e lunga distanza<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >Scelta della soluzione appropriata<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Optare per CWDM se si necessita di:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\">Distribuzione rapida per collegamenti \u226480 km.<\/p><\/li><li><p style=\"margin: 0px;\">Scalabilit\u00e0 economica (ad es. aggiunta incrementale di 8 canali).<\/p><\/li><li><p style=\"margin: 0px;\">Compatibilit\u00e0 con switch SFP+ esistenti.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Scegliere DWDM per:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\">Preparazione futura oltre i 100G.<\/p><\/li><li><p style=\"margin: 0px;\">Massimizzazione del ritorno sull\u2019investimento della fibra in condotti congestionati.<\/p><\/li><li><p style=\"margin: 0px;\">Esigenze di lunga distanza\/altissima capacit\u00e0.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >Transceiver ottici LINK\u2011PP: CWDM &amp; DWDM<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">LINK\u2011PP offre moduli di alta qualit\u00e0 progettati specificamente per entrambe le tecnologie:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Trasceivers ottici LINK\u2011PP CWDM:<\/strong> Scopri i trasceivers CWDM, perfetti per applicazioni metro-access che privilegiano semplicit\u00e0 ed economicit\u00e0 \u2192 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm?ca=1484&amp;cv=8851\">Modulo CWDM LINK\u2011PP<\/a>.<\/p><\/li><li><p><strong>Trasceivers ottici LINK\u2011PP DWDM:<\/strong> Offrono un controllo preciso della lunghezza d\u2019onda e una stabilit\u00e0 termica ottimale per implementazioni su rete principale e a lunga distanza \u2192 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm?ca=1484&amp;cv=8852\">Modulo DWDM LINK\u2011PP<\/a>.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Perch\u00e9 gli ingegneri si fidano di LINK-PP<\/strong>:<br\/>\u2705 Diagnostica DOM completa per il monitoraggio in tempo reale dello stato di salute.<br\/>\u2705 Garanzia triennale e interoperabilit\u00e0 multi-vendor (Cisco\/Juniper\/Arista).<br\/>\u2705 Progettazione a bassa latenza per cluster finanziari e per l\u2019IA.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Vedi anche<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/wdm-optical-transceiver-module-applications\/\">Esplorazione della tecnologia WDM e dei suoi utilizzi nelle reti ottiche<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/ddm-dom-nei-ricetrasmettitori-ottici\/\">L\u2019importanza del monitoraggio digitale nei dispositivi trasceivers ottici<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/dwdm-tunable-optical-transceiver-modules\/\">Presentazione della rete LINK-PP e dei suoi membri della comunit\u00e0<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>CWDM vs DWDM: ottica metropolitana a 8 canali economica vs sistemi a lunga distanza ad alta densit\u00e0 con 96+ canali. Scegli i transceiver ottici LINK-PP per entrambe le soluzioni WDM.<\/p>","protected":false},"author":1,"featured_media":5936,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[26],"class_list":["post-5938","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/5938","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/comments?post=5938"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/5938\/revisions"}],"predecessor-version":[{"id":11462,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/5938\/revisions\/11462"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media\/5936"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media?parent=5938"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/categories?post=5938"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/tags?post=5938"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}