{"id":5436,"date":"2025-08-15T00:00:00","date_gmt":"2025-08-15T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/psm4-vs-cwdm4-which-optical-transceiver-for-your-network\/"},"modified":"2026-06-22T08:25:49","modified_gmt":"2026-06-22T08:25:49","slug":"psm4-vs-cwdm4-which-optical-transceiver-for-your-network","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/psm4-vs-cwdm4-which-optical-transceiver-for-your-network","title":{"rendered":"PSM4 vs. CWDM4: quale trasceiver ottico \u00e8 adatto alla tua rete"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9.webp\" alt=\"100G PSM4 VS CWDM4\" class=\"wp-image-5432\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">La domanda di connettivit\u00e0 100G nei data center e nelle reti aziendali \u00e8 in forte espansione. Scegliere il giusto<br> <strong>trasmettitore ottico<\/strong> <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>(100G QSFP28)<br><\/strong><\/a> \u00e8 fondamentale per prestazioni, costo, scalabilit\u00e0 ed efficienza energetica. Due standard dominanti<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/multi-source-agreements-optical-transceivers\/\"><strong>MSA<\/strong><\/a> (Multi-Source Agreement) sono emersi:<br> <strong>PSM4 (Parallel Single Mode fiber 4 lane)<br><\/strong> and <strong>CWDM4 (Coarse Wavelength Division Multiplexing 4 lane)<br><\/strong>. Sebbene entrambi raggiungano i 100G su 2 km utilizzando fibra monomodale<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/what-is-single-mode-fiber-and-how-does-it-work\/\"><strong>(SMF)<\/strong><\/a>, le loro tecnologie sottostanti e i casi d\u2019uso ideali differiscono significativamente. Comprendere queste differenze tra trasceivers 100G \u00e8 essenziale per ottimizzare le reti dei data center e ridurre i costi degli interconnessioni ottiche.<br>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udd27 PSM4: Potenza della parallelizzazione<br><\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"618\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda.webp\" alt=\"100G PSM4\" class=\"wp-image-5433\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda-300x155.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda-1024x527.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda-768x396.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda-18x9.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">PSM4 (IEEE 802.3bm) adotta un approccio parallelo diretto:<br><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Tecnologia:<br><\/strong> Utilizza 4 corsie ottiche indipendenti (ciascuna a<br> <em>Lunghezza d\u2019onda 1310 nm<\/em>).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fiber:<\/strong> Richiede <strong>8 fibre<\/strong> (4 Tx, 4 Rx) \u2013 tipicamente con connettore MPO-12.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Funzionamento:<br><\/strong> Ogni corsia trasmette contemporaneamente dati a 25 Gbps sulla propria coppia di fibre dedicata.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Forze:<\/strong> Progettazione ottica pi\u00f9 semplice, che potenzialmente comporta costi inferiori dei componenti e un\u2019eccellente isolazione del segnale.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Punti deboli:<br><\/strong> Maggiore consumo di fibre, cavi pi\u00f9 ingombranti.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Ideale per:<br><\/strong> Portata ultra-ravvicinata (\u2264 500 m) all\u2019interno di rack o file, scenari di collegamento diretto ad alta densit\u00e0 in cui il numero di fibre non \u00e8 un vincolo primario. Un affidabile<br> <strong>modulo ottico PSM4<br><\/strong> come il <strong>LINK-PP LQ-M31100-DR4C<br><\/strong> garantisce prestazioni costanti per queste esigenti<br> <strong>applicazioni di ottica parallela<br><\/strong>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83c\udf08 CWDM4: Magia delle lunghezze d\u2019onda<br><\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b.webp\" alt=\"100G CWDM4\" class=\"wp-image-5434\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">CWDM4 (Specifiche MSA) sfrutta la multiplazione ottica per risparmiare fibre:<br><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Tecnologia:<br><\/strong> Utilizza 4 diverse lunghezze d\u2019onda CWDM (~1271 nm, 1291 nm, 1311 nm, 1331 nm) multiplexate su una<br> <em>singolo<\/em> coppia di fibre.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fiber:<\/strong> Richiede soltanto<br> <strong>2 fibre<\/strong> (1 Tx, 1 Rx) \u2013 tipicamente con connettore LC duplex.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Funzionamento:<br><\/strong> Un multiplexer (Mux) combina le 4 lunghezze d\u2019onda sulla fibra di trasmissione; un demultiplexer (Demux) le separa sul lato ricezione.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Forze:<\/strong> Riduce drasticamente il numero di fibre (4\u00d7 meno rispetto al PSM4), cavi pi\u00f9 piccoli, gestione dei cavi pi\u00f9 semplice, connettori LC standard.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Punti deboli:<br><\/strong> Richiede laser e componenti Mux\/Demux pi\u00f9 complessi (e potenzialmente pi\u00f9 costosi).<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Ideale per:<br><\/strong> The <strong>punto ottimale per la maggior parte dei collegamenti 100G su 2 km<br><\/strong> (es. interconnessioni intra-data center, collegamenti campus). \u00c8 la soluzione preferita per<br> <strong>l\u2019efficienza in fibra CWDM4 <\/strong> and <strong>connettivit\u00e0 100G economica<\/strong>. Il <strong>LINK-PP <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472577.htm\"><strong>LQ-CW100-FR4C<\/strong><\/a> \u00e8 progettato per garantire la massima affidabilit\u00e0 in queste reti a divisione di lunghezza d\u2019onda.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83e\udd4a Confronto diretto: PSM4 vs. CWDM4 \u2013 Le differenze chiave<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Caratteristica<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>PSM4 (100G-PSM4)<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4 (100G-CWDM4)<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Vincitore per\u2026<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Tecnologia<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 corsie parallele a 1310 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 corsie WDM (1271\/1291\/1311\/1331 nm)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Semplicit\u00e0 (PSM4) \/ Efficienza fibra (CWDM4)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Numero di fibre<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>8 fibre<\/strong> (MPO-12)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>2 fibre<\/strong> (LC Duplex)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4<\/strong> (Risparmi significativi)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Reach<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fino a 500 m (ottimale), 2 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fino a 2 km (standard)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Pareggio (entrambi supportano 2 km; PSM4 \u00e8 migliore \u2264 500 m)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Connettore<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>MPO-12\/APC<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>LC duplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4<\/strong> (Standard, gestione pi\u00f9 semplice)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Complessit\u00e0 del laser<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Pi\u00f9 semplice (4\u00d7 stessa \u03bb)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Pi\u00f9 complessa (4\u00d7 \u03bb diverse, multiplexing\/demultiplexing)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>PSM4<br><\/strong> (Potenzialmente costo inferiore)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Ingombro del cavo<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Maggiore (cavo pi\u00f9 spesso)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Minore (cavo pi\u00f9 sottile)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Caso d'uso principale<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Breve portata, alta densit\u00e0<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Interconnessione inter-data center (ICI) e interconnessione data center (DCI) standard a 2 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Dipende dalla distanza e dalle esigenze della fibra<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Fattore costo (componenti)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Potenzialmente laser meno costoso<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Potenzialmente laser + multiplexer\/demultiplexer pi\u00f9 costosi<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Dipendente dal contesto<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Fattore costo (infrastruttura)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Maggiore (pi\u00f9 fibra\/cablaggio)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Lower<\/strong> (Meno fibra\/cablaggio)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4<\/strong> (Costo complessivo dell\u2019infrastruttura)<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83c\udfc6 Scelta del vincitore: PSM4 o CWDM4?<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px 0px 4px;\"><strong>Scegli PSM4 se:<\/strong><\/p><ul><li><p style=\"margin: 0px;\">I tuoi collegamenti sono <strong>molto brevi (\u2264 500 m)<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>l\u2019infrastruttura in fibra \u00e8 abbondante ed economica<\/strong>, e l\u2019ingombro del cavo non rappresenta un problema rilevante.<\/p><\/li><li><p style=\"margin: 0px;\">Dai priorit\u00e0 a potenziali <strong>risparmi sui costi dei componenti<\/strong> rispetto all\u2019efficienza della fibra <em>per specifiche implementazioni a breve portata<\/em>.<\/p><\/li><li><p style=\"margin: 0px;\">\u00c8 necessario<br> <strong>ottiche parallele ad alta densit\u00e0<\/strong> all\u2019interno di uno spazio ristretto.<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>Scegli CWDM4 se (la scelta pi\u00f9 comune):<\/strong><\/p><ul><li><p style=\"margin: 0px;\">I tuoi collegamenti sono <strong>fino a 2 km<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>La conservazione della fibra \u00e8 fondamentale<\/strong> (consente risparmi significativi in termini di costi e complessit\u00e0).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Gestione dei cavi pi\u00f9 semplice<br><\/strong> si preferisce il collegamento LC duplex.<\/p><\/li><li><p style=\"margin: 0px;\">Hai bisogno di una <strong>soluzione standard e ampiamente interoperabile<\/strong> per interconnessioni tra data center (DCI) o collegamenti backbone aziendali.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Il costo complessivo dell\u2019infrastruttura<\/strong> (fibra + cablaggio + gestione) \u00e8 un fattore determinante.<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\ud83d\udca1 Soluzioni LINK-PP: Progettate per prestazioni e valore<\/strong><br\/>Che la tua progettazione di rete 100G richieda l\u2019efficienza parallela di <strong>PSM4<br><\/strong> o la capacit\u00e0 di multiplexing in lunghezza d\u2019onda di <strong>CWDM4<\/strong>,<a target=\"_blank\" rel=\"\" href=\"https:\/\/www.link-pp.com\/\"><strong> LINK-PP<\/strong><\/a> offre soluzioni ad alte prestazioni e conformi allo standard MSA:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Per parallelismo esigente a breve portata:<\/strong> The <strong>i transceiver LINK-PP PSM4<\/strong> offrono prestazioni robuste per ottiche 100G sensibili ai costi in applicazioni dense e a breve distanza.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Per interconnessione efficiente a 2 km:<\/strong> <strong>LINK-PP<\/strong> fornisce affidabilit\u00e0 e basso consumo energetico <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472577.htm\"><strong>100G<\/strong> <strong>dei trasceiver CWDM4<\/strong><\/a> ottimizzato per soluzioni scalabili per data center e reti aziendali ad alta larghezza di banda.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Entrambi i moduli subiscono rigorosi <strong>test sui trasceivers ottici<\/strong> per garantire compatibilit\u00e0, bassa <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/understanding-what-is-bit-error-rate\/\"><strong>tasso di errore sul bit (BER)<\/strong><\/a>, e longevit\u00e0, offrendovi fiducia nella vostra infrastruttura di rete ottica.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Conclusione: ottimizzare il vostro edge ottico<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Comprendere la<br> <strong>differenze tra PSM4 e CWDM4<\/strong> \u00e8 fondamentale per effettuare scelte consapevoli <strong>nella selezione dei trasceivers 100G<\/strong>. Mentre PSM4 offre semplicit\u00e0 per collegamenti paralleli ultra-brevi, <strong>CWDM4 \u00e8 diventato lo standard dominante per i collegamenti 100G su 2 km grazie alla sua superiore efficienza delle fibre, alla gestione pi\u00f9 semplice e ai costi complessivi inferiori dell\u2019infrastruttura.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pronti a ottimizzare il vostro deployment 100G con la giusta soluzione ottica? \ud83d\udd17<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\ud83d\udc49 Esplorate l\u2019intera gamma di moduli QSFP28 ad alte prestazioni e affidabili di LINK-PP, inclusi i nostri trasceivers CWDM4 e PSM4 leader di settore, progettati per offrire massimo valore e tempi di attivit\u00e0 per i vostri collegamenti critici. <\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>Visita la nostra pagina prodotti \u279e<\/strong><\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd FAQ<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Qual \u00e8 la differenza principale tra PSM4 e CWDM4?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PSM4 richiede otto fibre e utilizza connettori MPO\/MTP. Invia i dati in parallelo. CWDM4 richiede solo due fibre e utilizza connettori LC duplex. Invia i dati utilizzando lunghezze d\u2019onda diverse.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>PSM4 \u00e8 adatto per collegamenti brevi. CWDM4 \u00e8 migliore per distanze pi\u00f9 lunghe.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >Quale transceiver \u00e8 pi\u00f9 facile da installare nelle reti esistenti?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">CWDM4 \u00e8 generalmente pi\u00f9 semplice da installare. La maggior parte delle reti utilizza gi\u00e0 connettori LC e cavi a due fibre.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>PSM4 potrebbe richiedere nuove fibre parallele, se non le si possiede gi\u00e0.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Quale opzione \u00e8 pi\u00f9 conveniente dal punto di vista dei costi per distanze brevi?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PSM4 costa spesso meno per collegamenti brevi, se si dispone gi\u00e0 di fibre parallele.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>CWDM4 pu\u00f2 far risparmiare sui cavi per reti nuove o pi\u00f9 estese.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >Entrambi i transceiver PSM4 e CWDM4 supportano gli aggiornamenti futuri della rete?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">CWDM4 \u00e8 migliore per gli aggiornamenti. Utilizza meno fibre, quindi \u00e8 facile aggiungerne altre.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>PSM4 potrebbe richiedere pi\u00f9 spazio man mano che la rete cresce.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Quale transceiver dovrebbe scegliere un data center per collegamenti lunghi?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un data center dovrebbe scegliere CWDM4 per collegamenti fino a 2 chilometri.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>PSM4 \u00e8 ideale per collegamenti brevi all\u2019interno di un edificio.<\/p><\/blockquote>","protected":false},"excerpt":{"rendered":"<p>Confronta PSM4 e CWDM4 per scegliere il trasceiver ottico da 100G pi\u00f9 adatto alla tua rete in base a distanza, cablaggio, costo e esigenze di aggiornamento.<\/p>","protected":false},"author":1,"featured_media":5435,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13],"class_list":["post-5436","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/5436","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/comments?post=5436"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/5436\/revisions"}],"predecessor-version":[{"id":11253,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/5436\/revisions\/11253"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media\/5435"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media?parent=5436"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/categories?post=5436"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/tags?post=5436"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}