{"id":5417,"date":"2025-08-16T00:00:00","date_gmt":"2025-08-16T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/100g-qsfp28-optical-transceivers-selection-guide\/"},"modified":"2026-06-22T09:08:37","modified_gmt":"2026-06-22T09:08:37","slug":"100g-qsfp28-optical-transceivers-selection-guide","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/100g-qsfp28-optical-transceivers-selection-guide","title":{"rendered":"Guida completa alla scelta dei trasmettitori ottici QSFP28 da 100G: SR4, LR4, CWDM4 e altro ancora"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a117d9c4ef2b4fb1ba276f80e39727aa.webp\" alt=\"100g qsfp28 transceivers\" class=\"wp-image-5415\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a117d9c4ef2b4fb1ba276f80e39727aa.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a117d9c4ef2b4fb1ba276f80e39727aa-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a117d9c4ef2b4fb1ba276f80e39727aa-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a117d9c4ef2b4fb1ba276f80e39727aa-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a117d9c4ef2b4fb1ba276f80e39727aa-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><span class=\"qc-p1-tag\">Quando scegli un <\/span><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><span class=\"qc-p1-tag\"><strong>transceiver 100G QSFP28<\/strong><\/span><\/a><span class=\"qc-p1-tag\">, considera le esigenze della tua rete. Verifica elementi importanti come la compatibilit\u00e0, la distanza che i dati devono percorrere, il tipo di fibra, il tipo di connettore, l\u2019ambiente di utilizzo e la compatibilit\u00e0 futura. Scegliere transceiver ottici QSFP28 adatti al tuo sistema garantisce prestazioni ottimali della rete e protegge il tuo investimento. <\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">Questa guida definitiva chiarisce ogni dubbio, analizzando tutte le principali opzioni QSFP28 da 100 G \u2013 da <\/span><span class=\"qc-p1-tag\"><strong>SR4<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\"> and <\/span><span class=\"qc-p1-tag\"><strong>LR4<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\"> a <\/span><span class=\"qc-p1-tag\"><strong>CWDM4<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">, <\/span><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/100g-single-lambda-transceivers-benefits-upgrades-performance\/\"><span class=\"qc-p1-tag\"><strong>Singolo lambda<\/strong><\/span><\/a><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">, e oltre \u2013 per aiutarti a prendere una decisione informata per il tuo <\/span><span class=\"qc-p1-tag\"><strong>\ud83d\udd0d L'Eroe Non Cantato: Trasmettitori Ottici nelle Reti LTE<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\"> .<\/span><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Che cos\u2019\u00e8 un modulo ottico QSFP28?<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">The <strong>QSFP28 (Quad Small Form-factor Pluggable 28)<\/strong> \u00e8 il fattore di forma standard di settore per l\u2019Ethernet da 100 Gigabit (100GbE) e per gli interconnessioni ad alta velocit\u00e0 nei data center. Integra quattro corsie operative a 25 Gbps o una singola corsia ad alta velocit\u00e0 in un modulo compatto e hot-pluggable.<\/span><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Demistificare le tue opzioni QSFP28 da 100 G: analisi tecnica<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p style=\"margin: 0px 0px 4px;\"><strong>100G-SR4 (corto raggio)<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>Tecnologia:<br><\/strong> Fibra multimodale parallela (MMF) con 4 corsie (4\u00d725G NRZ).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Portata:<br><\/strong> Fino a 70 m (MMF OM3), 100 m (MMF OM4) o 150 m (MMF OM5).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Tipo di fibra:<\/strong> Richiede <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/mpo-connectors-differences-8-12-16-24-fiber-comparison\/\"><strong>MTP\/MPO-12<\/strong><\/a> connettore. Utilizza 4 fibre per la trasmissione (Tx) e 4 fibre per la ricezione (Rx) <strong>(8 fibre in totale)<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Ideali per:<\/strong> <strong>Commutazione top-of-rack<\/strong>, <strong>collegamenti intra-data center<br><\/strong>, connettivit\u00e0 server-to-leaf all\u2019interno di rack o file mediante <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/om1-om2-om3-om4-om5-multimode-fiber-guide\/\"><strong>cablaggio in fibra multimodale<\/strong><\/a>. Economico per brevi distanze.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Esempio di modello:<\/strong> QSFP28-100G-SR4 <strong>LINK-PP <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473115.htm\"><strong>LQ-M85100-SR4C<\/strong><\/a> (supporta OM3\/OM4\/OM5)<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>100G-PSM4 (4 corsie parallele in fibra monomodale)<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>Tecnologia:<br><\/strong> Fibra monomodale parallela <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/what-is-single-mode-fiber-and-how-does-it-work\/\"><strong>(SMF)<\/strong><\/a> con 4 corsie (4\u00d725G NRZ).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Portata:<br><\/strong> Tipicamente fino a 500 m su SMF standard.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Tipo di fibra:<\/strong> Richiede <strong>MTP\/MPO-12<\/strong> connettore. Utilizza 4 fibre per la trasmissione (Tx) e 4 fibre per la ricezione (Rx) <strong>(8 fibre in totale)<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Ideali per:<\/strong> Collegamenti intra-data center o campus pi\u00f9 lunghi rispetto a SR4, dove l\u2019infrastruttura in fibra monomodale \u00e8 gi\u00e0 presente o preferita per garantire la compatibilit\u00e0 futura. Meno comune rispetto a CWDM4\/LR4 per portate pi\u00f9 lunghe su SMF.<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>100G-LR4 \/ ER4 \/ ZR4 (lungo raggio \/ raggio esteso \/ raggio esteso+)<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>Tecnologia:<br><\/strong> Coarse Wavelength Division Multiplexing <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-cwdm-understanding-coarse-wavelength-division-multiplexing\/\"><strong>(CWDM)<\/strong><\/a> su fibra monomodale duplex. Combina 4 lunghezze d\u2019onda (circa 1295, 1300, 1304, 1309 nm) su 2 fibre (1 Tx, 1 Rx). LR4 \u00e8 lo standard, ER4 offre portata estesa, ZR4 offre la portata massima.<\/p><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>Portata:<br><\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>LR4:<\/strong> fino a 10 km<\/p><\/li><li><p style=\"margin: 0px;\"><strong>ER4:<\/strong> Fino a 40 km<\/p><\/li><li><p style=\"margin: 0px;\"><strong>ZR4:<\/strong> Fino a 80 km+<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px;\"><strong>Tipo di fibra:<\/strong> Utilizza connettori standard <strong>interfaccia duplex LC<br><\/strong> Richiede solo 2 fibre.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Ideali per:<\/strong> <strong>Interconnessione tra data center (DCI)<\/strong>, <strong>reti metropolitane<\/strong>, collegamenti tra edifici, livelli di aggregazione. Fondamentale per <strong>trasmissione ottica su lunga distanza<\/strong>. ER4\/ZR4 sono destinati ad applicazioni specializzate a lunga distanza.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Esempio di modello:<\/strong> LINK-PP QSFP28-100G-LR4 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472118.htm\"><strong>LQ-LW100-LR4C<\/strong><\/a> (10 km), LINK-PP QSFP28-100G-ER4 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472708.htm\"><strong>LQ-LW100-ER4C<\/strong><\/a> (40 km), LINK-PP QSFP28-100G-ZR4 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482513.htm\"><strong>LQ-LW100-ZR4C<\/strong><\/a> (80 km)<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>100G-CWDM4<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>Tecnologia:<br><\/strong> Simile a LR4, utilizza <strong>CWDM<\/strong> su fibra monomodale (SMF) duplex ma con lunghezze d\u2019onda leggermente diverse (1271, 1291, 1311, 1331 nm), ottimizzate per ridurre i costi e il consumo energetico.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Portata:<br><\/strong> Fino a 2 km. Definito dal CWDM4 MSA.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Tipo di fibra:<\/strong> Utilizza connettori standard <strong>interfaccia duplex LC<br><\/strong> Richiede solo 2 fibre.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Ideali per:<\/strong> Soluzione economica per <strong>collegamenti SMF all\u2019interno del data center<\/strong> fino a 2 km (ad esempio, tra edifici in un campus o tra sale dati pi\u00f9 ampie). Alternativa popolare al PSM4 per SMF duplex.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Esempio di modello:<\/strong> LINK-PP QSFP-100G-CWDM4 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472577.htm\"><strong>LQ-CW100-FR4C<\/strong><\/a> (2 km)<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>100G Single Lambda (ad es. FR1\/LR1\/ER1\/DR1\/ZR1)<\/strong><\/p><ul><li><p style=\"margin: 0px 0px 4px;\"><strong>Tecnologia:<br><\/strong> Utilizza una <em>singolo<\/em> lunghezza d\u2019onda ad alta velocit\u00e0 (ad es. 53,125 Gbaud <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\"><strong>modulazione PAM4<\/strong><\/a>) su fibra monomodale (SMF) duplex. Include diverse portate:<\/p><ul><li><p style=\"margin: 0px;\"><strong>FR1 (2 km) \/ LR1 (10 km):<\/strong> Standard comuni.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>DR1 (500 m):<\/strong> Utilizza spesso la lunghezza d\u2019onda 1310 nm.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>ER1 (40 km) \/ ZR1 (80 km+):<\/strong> Varianti a portata estesa.<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px;\"><strong>Portata:<br><\/strong> Variabile (500 m, 2 km, 10 km, 40 km, 80 km+).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Tipo di fibra:<\/strong> Utilizza connettori standard <strong>interfaccia duplex LC<br><\/strong> Richiede solo 2 fibre.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Ideali per:<\/strong> <strong>Architetture di data center di nuova generazione<\/strong>, semplificando l\u2019impianto in fibra (necessari soltanto 2 filamenti di fibra per collegamento) e preparandosi a 400G\/800G (che si basano fortemente su PAM4). Offre <strong>densit\u00e0 di porte significativamente maggiore<\/strong> potenzialit\u00e0. Fondamentale per <strong>una progettazione di rete a prova di futuro<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Esempio di modello:<\/strong> LINK-PP QSFP-100G-DR1 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482616.htm\"><strong>LQ-SM31100-DR1C<\/strong><\/a> (10 km).<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>100G-SWDM4 (Multiplexing a divisione di lunghezza d\u2019onda a corta lunghezza d\u2019onda)<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>Tecnologia:<br><\/strong> Utilizza il multiplexing a divisione di lunghezza d\u2019onda su fibra multimodale (MMF). Combina 4 <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/overview-of-vcsel\/\"><strong>Laser VCSEL.<br><\/strong><\/a>lunghezze d\u2019onda basate su laser (850, 880, 910, 940 nm) su 2 filamenti di fibra (1 in trasmissione, 1 in ricezione).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Portata:<br><\/strong> Fino a 75 m (OM3), 100 m (OM4), 150 m (OM5).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Tipo di fibra:<\/strong> Utilizza connettori standard <strong>interfaccia duplex LC<br><\/strong> Richiede solo 2 fibre.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Ideali per:<\/strong> Sfruttando la cabling MMF duplex LC <strong>esistente<\/strong> per 100G, evitando la necessit\u00e0 di aggiornamenti a connettori MTP\/MPO. Ideale per <strong>strategie di migrazione della fibra<\/strong> dove prevale la MMF duplex.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Esempio di modello:<\/strong> LINK-PP QSFP-100G-SWDM4 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473140.htm\"><strong>LQ-SW100-SR4C<\/strong><\/a> (100 m)<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>100G Bidirezionale (BiDi)<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>Tecnologia:<br><\/strong> Utilizza una <em>singolo<\/em> singolo filamento di fibra. Raggiunge un collegamento full-duplex a 100G trasmettendo e ricevendo su due lunghezze d\u2019onda differenti (ad es. Tx 1330 nm \/ Rx 1270 nm) sullo stesso filamento di fibra.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Portata:<br><\/strong> Tipicamente fino a 10 km o 20 km su SMF.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Tipo di fibra:<\/strong> Utilizza una <strong>connettore LC simplex<\/strong> Richiede un solo filamento di fibra per collegamento.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Ideali per:<\/strong> <strong>Massimizzazione dell\u2019infrastruttura in fibra esistente<\/strong> (raddoppiando la capacit\u00e0), <strong>scenari di esaurimento della fibra<\/strong>, aggiornamenti economici in contesti di scarsit\u00e0 di fibra. Fondamentale per <strong>l\u2019ottimizzazione della capacit\u00e0 della fibra<\/strong>.<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>Moduli dual-rate 100G\/112G<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>Tecnologia:<br><\/strong> TOSA ermetico con <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-lwdm-and-why-important-for-lans\/\"><strong>LAN-WDM<\/strong><\/a> supporto per DFB basato su velocit\u00e0 dati di 25,78 G\/s e 27,95 G\/s.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Portata:<br><\/strong> Tipicamente fino a 10 km su SMF<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Tipo di fibra:<\/strong> Utilizza connettori standard <strong>interfaccia duplex LC<br><\/strong> Richiede solo 2 fibre.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Ideali per:<\/strong> Collegamenti Ethernet 100GBASE-LR4, interconnessioni Infiniband QDR e DDR, connessioni telecom client-side a 100G.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Esempio di modello:<\/strong> LINK-PP <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/488452.htm\"><strong>LQ-LW112-LR4C<\/strong><\/a>.<\/p><\/li><\/ul><\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5d7fcaaefde14dedb89f4bc7ecd50005.webp\" alt=\"100g qsfp28 module\" class=\"wp-image-5416\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5d7fcaaefde14dedb89f4bc7ecd50005.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5d7fcaaefde14dedb89f4bc7ecd50005-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5d7fcaaefde14dedb89f4bc7ecd50005-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5d7fcaaefde14dedb89f4bc7ecd50005-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5d7fcaaefde14dedb89f4bc7ecd50005-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Confronto dei trasceivers 100G QSFP28 a colpo d\u2019occhio<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Tipo di modulo<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Tecnologia<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Lunghezza d\u2019onda<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Tipo di fibra e connettore<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Portata massima<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Applicazione chiave<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G-SR4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4\u00d725G NRZ (MMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>850nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>MMF \/ MPO-12<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>70 m \u2013 150 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Collegamenti brevi all\u2019interno del data center, switching ToR<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G-PSM4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4\u00d725G NRZ (SMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1310 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SMF \/ MPO-12<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>500 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Collegamenti medi all\u2019interno del data center\/campus (paralleli)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G-LR4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4\u00d725G LWDM<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~1295\u20131310 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SMF \/ LC Duplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Interconnessione data center (DCI), rete metropolitana (Metro), collegamenti tra edifici<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G-ER4\/ZR4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4\u00d725G LWDM<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~1295\u20131310 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SMF \/ LC Duplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>40 km \/ 80 km+<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>DCI a lunga distanza, rete metropolitana<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G-CWDM4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4\u00d725G CWDM<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1271\u20131331 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SMF \/ LC Duplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>2 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SMF all\u2019interno del data center: soluzione economica<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G a singolo lambda<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1\u00d7100G PAM4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1310 nm (ad esempio)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SMF \/ LC Duplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>500 m \u2013 80 km+<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Data center di nuova generazione, semplificazione della fibra<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G-SWDM4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4\u00d725G WDM (MMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>850\u2013940 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>MMF \/ LC Duplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>75 m \u2013 150 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Sfruttare il cablaggio MMF duplex<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G BiDi<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1\u00d7100G BiDi<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>ad esempio, Tx1330\/Rx1270<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SMF \/ LC simplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10 km \/ 20 km \/ 40 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Esaurimento fibre, singolo filamento<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Doppia velocit\u00e0 (ad esempio LR4)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>100G \/ 112G <\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>LAN-WDM, 1295\u20131309 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SMF \/ LC duplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Dipende dalla modalit\u00e0<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Migrazione e flessibilit\u00e0 di aggregazione<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Scelta del modulo LINK-PP QSFP28 pi\u00f9 adatto: considerazioni chiave<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Distanza richiesta:<\/strong> Questo \u00e8 il fattore principale (SR4 per MMF &lt;150 m, CWDM4 per SMF a 2 km, LR4 per 10 km, ecc.).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Infrastruttura in fibra:<\/strong> Che cosa \u00e8 gi\u00e0 installato (MMF vs SMF, MPO vs LC duplex\/simplex)? SWDM4 utilizza MMF duplex, BiDi utilizza SMF simplex.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Costo:<\/strong> SR4 e CWDM4 sono generalmente meno costosi rispetto a LR4\/ER4 o a Single Lambda. BiDi pu\u00f2 ridurre i costi delle fibre.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Consumo di potenza:<\/strong> CWDM4 e moduli PAM4 pi\u00f9 recenti <strong>(Singolo Lambda)<\/strong> hanno spesso un consumo energetico inferiore rispetto a LR4.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Protezione futura:<\/strong> I moduli Singolo Lambda sono allineati alle tecnologie 400G\/800G che utilizzano <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\"><strong>trasmettitore PAM4<\/strong><\/a>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Esigenze a doppia velocit\u00e0:<\/strong> \u00c8 necessaria ora o in futuro una connettivit\u00e0 4\u00d725G o 4\u00d728G?<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Capacit\u00e0 della fibra:<\/strong> La fibra \u00e8 scarsa? I moduli BiDi raddoppiano efficacemente la capacit\u00e0 della vostra fibra.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Ottimizzate la vostra rete 100G con sicurezza<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Selecting the optimal <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>transceiver 100G QSFP28<\/strong><\/a> \u00e8 fondamentale per raggiungere <strong>reti ad alte prestazioni<\/strong>, <strong>architetture di data center scalabili<\/strong>, and <strong>massimizzare il ROI<\/strong> sulla vostra <strong>infrastruttura in fibra ottica<\/strong>. Comprendendo i punti di forza di ciascuna tecnologia \u2013 dalla convenienza economica dei moduli <strong>100G-SR4<\/strong> per rack fino alle capacit\u00e0 per collegamenti lunghi di <strong>100G-LR4\/ER4<\/strong>, alla magia del risparmio di fibra offerta da <strong>100G-BiDi<\/strong>, o alla prontezza futura dei <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/100g-single-lambda-transceivers-benefits-upgrades-performance\/\"><strong>moduli 100G Singolo Lambda (PAM4)<\/strong><\/a> \u2013 potrete prendere decisioni strategiche allineate alle vostre specifiche <strong>esigenze di progettazione della rete<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pronti a implementare connettivit\u00e0 100G ad alte prestazioni?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>LINK-PP offre un portafoglio completo di moduli ottici, <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/multi-source-agreements-optical-transceivers\/\"><strong>conforme allo standard MSA<\/strong><\/a><strong> 100G QSFP28 affidabili<\/strong>, compresi tutti i tipi discussi: <strong>SR4<\/strong>, <strong>LR4<\/strong>, <strong>ER4<\/strong>, <strong>CWDM4<\/strong>, <strong>Singolo Lambda (DR1\/FR1)<\/strong>, <strong>Il modulo SWDM4<\/strong>, <strong>Moduli SFP<\/strong>, and <strong>A doppia velocit\u00e0<\/strong> soluzioni. I nostri trasceiver sono sottoposti a test rigorosi per <strong>l\u2019interoperabilit\u00e0<\/strong> e prestazioni, garantendo un\u2019integrazione senza interruzioni nei vostri <strong>Cisco<\/strong>, <strong>Arista<\/strong>, <strong>Juniper<\/strong>, <strong>switch e router Mellanox<\/strong>, or <strong>Huawei<\/strong> .<\/p>\n\n\n\n<div class=\"alignnone qc-cover-wrapper has-custom-content-position is-position-center\" elementtype=\"div\" useimagebackground=\"false\" imgbg=\"\" imgbgpositionleft=\"50\" imgbgpositiontop=\"50\" overlay=\"#165DFF\" overlayopacity=\"0.8\" contentposition=\"center\" alt=\"\" parallax=\"false\" style=\"border-radius: 12px; padding-left: var(--qc-preset--spacing--60); padding-right: var(--qc-preset--spacing--60); padding-top: var(--qc-preset--spacing--50); padding-bottom: var(--qc-preset--spacing--50); background-color: rgb(245, 245, 245); height: auto;\"><div class=\"qc-cover-wrapper__inner-container\"><div style=\"flex-wrap: wrap; justify-content: center; display: flex;\"><div colmd=\"10\" class=\"col col-md-10\"><p style=\"text-align: center;\"><span class=\"qc-h1-tag\" style=\"color: var(--qc-color5);\">Soluzioni LINK-PP<\/span><\/p><p style=\"text-align: center;\"><strong>Esplorate oggi l\u2019intera gamma di moduli 100G QSFP28!<\/strong><\/p><div class=\"qc-buttons-wrapper\"><div justification=\"center\" class=\"qc-buttons-container is-horizontal is-content-justification-center\" style=\"margin-top: var(--qc-preset--spacing--0); margin-bottom: var(--qc-preset--spacing--0); gap: var(--qc-preset--spacing--40);\"><div link=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\" opennewtab=\"true\" width=\"\" outline=\"false\" class=\"qc-button-wrapper\" style=\"background-color: var(--qc-color1);\"><a class=\"qc-button-container\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\" target=\"_blank\"><span style=\"color: rgb(191, 61, 55);\"><strong>\ud83d\udd0dRichiedi subito<\/strong><\/span><\/a><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Vedi anche<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/100g-optical-transceiver-form-factors-guide\/\">Formati dei moduli ottici transceiver 100G: CFP, CFP2, CFP4, CXP, QSFP28<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/100g-single-lambda-transceivers-benefits-upgrades-performance\/\">Cosa occorre sapere sugli ottici 100G Singolo Lambda<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/100g-single-lambda-vs-4-channel-optical-modules-comparison\/\">Confronto tra moduli ottici da 100 G con singolo lambda e a 4 canali: principali differenze<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/psm4-vs-cwdm4-which-optical-transceiver-for-your-network\/\">Transceiver PSM4 vs. CWDM4: spiegata la differenza fondamentale<\/a><\/p>\n\n\n\n<script>const link1 = document.createElement('link');link1.rel = 'stylesheet';link1.type = 'text\/css';link1.href = 'https:\/\/statics.quickcreator.io\/static\/theme\/css\/qcb-theme-additional.css';const link2 = document.createElement('link');link2.rel = 'stylesheet';link2.type = 'text\/css';link2.href = 'https:\/\/statics.quickcreator.io\/static\/aaapycm22qmuab44\/theme\/css\/qcb-main-theme.css';document.head.appendChild(link1);document.head.appendChild(link2);<\/script>","protected":false},"excerpt":{"rendered":"<p>Scegli il miglior trasmettitore ottico QSFP28 da 100G per la tua rete confrontando compatibilit\u00e0, distanza, tipo di fibra e opzioni di futura evoluzione.<\/p>","protected":false},"author":1,"featured_media":5415,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13],"class_list":["post-5417","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/5417","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/comments?post=5417"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/5417\/revisions"}],"predecessor-version":[{"id":11392,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/5417\/revisions\/11392"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media\/5415"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media?parent=5417"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/categories?post=5417"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/tags?post=5417"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}