{"id":5288,"date":"2025-08-30T00:00:00","date_gmt":"2025-08-30T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/sff-8636-vs-cmis-qsfp-modules-management-interfaces\/"},"modified":"2026-06-22T09:07:06","modified_gmt":"2026-06-22T09:07:06","slug":"sff-8636-vs-cmis-qsfp-modules-management-interfaces","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/sff-8636-vs-cmis-qsfp-modules-management-interfaces","title":{"rendered":"SFF-8636 contro CMIS: l\u2019evoluzione delle interfacce di gestione per i moduli QSFP"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/572c054c2a5746b08b5773dd4f54a0e1.webp\" alt=\"SFF-8636 vs. CMIS\" class=\"wp-image-5287\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/572c054c2a5746b08b5773dd4f54a0e1.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/572c054c2a5746b08b5773dd4f54a0e1-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/572c054c2a5746b08b5773dd4f54a0e1-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/572c054c2a5746b08b5773dd4f54a0e1-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/572c054c2a5746b08b5773dd4f54a0e1-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><span style=\"color: rgb(9, 12, 30);\">\ud83d\udd39 <\/span>Introduzione<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Nel panorama in rapida evoluzione dei trasceivers ottici, le interfacce di gestione svolgono un ruolo cruciale nell\u2019abilitare l\u2019interoperabilit\u00e0, il monitoraggio e la configurazione di moduli ad alta velocit\u00e0. Due standard chiave hanno plasmato questo campo: <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/sff-8636-standard-qsfp-qsfp28-management-interface-guide\/\"><strong>SFF-8636<\/strong><\/a>, che definiva l\u2019interfaccia di gestione per i primi moduli QSFP, e <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/cmis-common-management-interface-specification\/\"><strong>CMIS<br><\/strong><\/a><strong> (Specifiche comuni per l\u2019interfaccia di gestione)<\/strong>, progettata per i trasceivers ad alta velocit\u00e0 di nuova generazione. Questo articolo ne esplora le differenze, la portata e la transizione da SFF-8636 a CMIS.<\/p>\n\n\n\n<hr class=\"wp-block-separator\" \/>\n\n\n\n<h2 class=\"wp-block-heading\" ><span style=\"color: rgb(9, 12, 30);\">\ud83d\udd39 <\/span>Cos\u2019\u00e8 SFF-8636?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">SFF-8636 \u00e8 una specifica che definisce l\u2019interfaccia di gestione per i trasceivers QSFP, basata sul protocollo di comunicazione I\u00b2C. Stabilisce:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>mappe di memoria e registri<\/p><\/li><li><p>Monitoraggio digitale della diagnostica (DDM\/DOM)<\/p><\/li><li><p>identificazione del modulo e segnalazione dello stato<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Applicazioni:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482754.htm\"><strong>QSFP+ (40 G)<br><\/strong><\/a><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/488423.htm\"><strong>QSFP28 (100G)<\/strong><\/a><strong>)<\/strong><\/p><\/li><li><p><strong>Iniziali <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472016.htm\"><strong>QSFP-DD<\/strong><\/a><strong> (200 G\/400 G)<br><\/strong> i moduli hanno adottato anche SFF-8636 per garantire la compatibilit\u00e0 all\u2019indietro.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">SFF-8636 \u00e8 stato fondamentale per la standardizzazione della gestione QSFP, ma con l\u2019aumento delle velocit\u00e0 dati i suoi limiti sono diventati evidenti.<\/p>\n\n\n\n<hr class=\"wp-block-separator\" \/>\n\n\n\n<h2 class=\"wp-block-heading\" ><span style=\"color: rgb(9, 12, 30);\">\ud83d\udd39 <\/span>Cos\u2019\u00e8 CMIS?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>CMIS (Specifiche comuni per l\u2019interfaccia di gestione)<\/strong>, sviluppato dall\u2019OIF e dai partner del settore, \u00e8 il nuovo standard progettato per affrontare la complessit\u00e0 dei moderni moduli ottici ad alta velocit\u00e0. CMIS si basa sulla struttura di SFF-8636 ma introduce funzionalit\u00e0 avanzate quali:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>supporto multi-host e multi-lane<\/p><\/li><li><p>configurazione flessibile delle applicazioni<\/p><\/li><li><p>diagnosi avanzate e gestione dei guasti<\/p><\/li><li><p>scalabilit\u00e0 per <strong>moduli 200G, 400G, 800G e futuri 1,6T<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Applicazioni:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>QSFP-DD<\/strong> (200 G\/400 G)<br><\/p><\/li><li><p><strong>OSFP<\/strong> (400 G\/800 G)<br><\/p><\/li><li><p><strong>COBO<br><\/strong> e altri fattori di forma emergenti<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Oggi, la maggior parte dei <strong>moduli 400G e 800G adotta <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/cmis-common-management-interface-specification\/\"><strong>CMIS<br><\/strong><\/a><strong> come interfaccia di gestione di fatto<\/strong>.<\/p>\n\n\n\n<hr class=\"wp-block-separator\" \/>\n\n\n\n<h2 class=\"wp-block-heading\" ><span style=\"color: rgb(9, 12, 30);\">\ud83d\udd39 <\/span>Principali differenze: SFF-8636 contro CMIS<\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 204px;\"\/><col style=\"width: 264px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"204\"><p>Caratteristica<\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"264\"><p><strong>SFF-8636<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>CMIS<br><\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"204\"><p>Origine<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"264\"><p>gestione QSFP\/QSFP28<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>specifica unificata di nuova generazione<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"204\"><p>Moduli supportati<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"264\"><p>QSFP+, QSFP28, QSFP-DD iniziali<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>QSFP-DD, OSFP, COBO<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"204\"><p>Velocit\u00e0 dati<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"264\"><p>40G \/ 100G (alcuni 200G\/400G)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>200G \/ 400G \/ 800G \/ 1,6T+<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"204\"><p>Flessibilit\u00e0<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"264\"><p>monitoraggio e identificazione di base<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>supporto multi-velocit\u00e0 e multi-applicazione<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"204\"><p>Diagnostica<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"264\"><p>DDM\/DOM standard<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>isolamento avanzato dei guasti e monitoraggio<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<hr class=\"wp-block-separator\" \/>\n\n\n\n<h2 class=\"wp-block-heading\" ><span style=\"color: rgb(9, 12, 30);\">\ud83d\udd39 <\/span>Cronologia dell\u2019evoluzione<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Era 40G\/100G (QSFP+, QSFP28):<\/strong> SFF-8636 come standard di settore.<\/p><\/li><li><p><strong>Primi 200G\/400G (QSFP-DD):<\/strong> compatibilit\u00e0 all\u2019indietro con SFF-8636.<\/p><\/li><li><p><strong>Moderni 400G\/800G (QSFP-DD, OSFP):<\/strong> transizione a CMIS come standard unificato.<\/p><\/li><li><p><strong>Futuri 1,6T e oltre:<\/strong> CMIS continua a essere l\u2019interfaccia scalabile.<\/p><\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator\" \/>\n\n\n\n<h2 class=\"wp-block-heading\" ><span style=\"color: rgb(9, 12, 30);\">\ud83d\udd39 <\/span>Il ruolo di LINK-PP nelle reti ad alta velocit\u00e0<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Presso LINK-PP offriamo un ampio portafoglio di trasceivers ottici e soluzioni di interconnessione progettate per soddisfare le esigenze sia degli standard legacy che di quelli di nuova generazione:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473115.htm\"><strong>moduli QSFP28 da 100G<\/strong><\/a> pienamente conformi all\u2019interfaccia di gestione SFF-8636.<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/470377.htm\"><strong>Moduli QSFP-DD da 400G<\/strong><\/a><strong> e moduli OSFP<\/strong> che supportano CMIS, garantendo la compatibilit\u00e0 con le moderne implementazioni nei data center.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">I nostri prodotti offrono <strong>elevata affidabilit\u00e0, ampia compatibilit\u00e0 ed eccellente rapporto qualit\u00e0-prezzo<\/strong>, aiutando i data center e i fornitori di telecomunicazioni a scalare le proprie reti in modo efficiente.<\/p>\n\n\n\n<hr class=\"wp-block-separator\" \/>\n\n\n\n<h2 class=\"wp-block-heading\" ><span style=\"color: rgb(9, 12, 30);\">\ud83d\udd39 <\/span>Conclusione<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La transizione da <strong>SFF-8636 a CMIS<\/strong> rappresenta un passo importante nell\u2019evoluzione delle interfacce di gestione per i moduli ottici. Sebbene SFF-8636 rimanga fondamentale per i moduli 40G\/100G, CMIS si \u00e8 affermato come nuovo standard di settore per 200G, 400G, 800G e oltre. Questo passaggio garantisce flessibilit\u00e0, scalabilit\u00e0 e diagnosi avanzate essenziali per i data center iperscalabili.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Per le aziende e gli operatori di rete, comprendere questi standard \u00e8 fondamentale per pianificare infrastrutture pronte per il futuro. <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26044-200-400-800g-transceiver-modules.htm\">La linea di prodotti LINK-PP<\/a> supporta entrambi gli standard, fungendo da ponte tra sistemi legacy e implementazioni di nuova generazione.<\/p>","protected":false},"excerpt":{"rendered":"<p>Esplora le differenze tra SFF-8636 e CMIS, due importanti standard di interfaccia di gestione che definiscono i moduli ottici QSFP per data center e reti.<\/p>","protected":false},"author":1,"featured_media":5287,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[26],"class_list":["post-5288","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/5288","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/comments?post=5288"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/5288\/revisions"}],"predecessor-version":[{"id":11383,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/5288\/revisions\/11383"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media\/5287"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media?parent=5288"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/categories?post=5288"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/tags?post=5288"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}