{"id":5125,"date":"2025-09-10T00:00:00","date_gmt":"2025-09-10T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/qsfp-40g-fr4-meaning-benefits-network-future-proof\/"},"modified":"2026-06-22T07:28:49","modified_gmt":"2026-06-22T07:28:49","slug":"qsfp-40g-fr4-meaning-benefits-network-future-proof","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/qsfp-40g-fr4-meaning-benefits-network-future-proof","title":{"rendered":"QSFP+ 40G FR4 spiegato: la tua guida definitiva alle ottiche parallele 4\u00d710G"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8e33a45f15b14fecb912b5b290bdc1b4.webp\" alt=\"What is qsfp+ 40g FR4 and why does it matter\" class=\"wp-image-5123\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8e33a45f15b14fecb912b5b290bdc1b4.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8e33a45f15b14fecb912b5b290bdc1b4-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8e33a45f15b14fecb912b5b290bdc1b4-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8e33a45f15b14fecb912b5b290bdc1b4-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8e33a45f15b14fecb912b5b290bdc1b4-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Nel mondo ad alta velocit\u00e0 dei data center e delle reti aziendali, la richiesta di larghezza di banda \u00e8 in costante aumento. La scelta del giusto transceiver ottico \u00e8 fondamentale per costruire un\u2019infrastruttura di rete scalabile, efficiente ed economica. Tra le varie opzioni disponibili, il<br> <strong>QSFP+ 40G FR4<br><\/strong> si distingue come soluzione fondamentale per ottenere connettivit\u00e0 40G.<br>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ma cos\u2019\u00e8 esattamente e perch\u00e9 \u00e8 cos\u00ec importante? Questa guida completa analizzer\u00e0 la tecnologia, le specifiche e i vantaggi del<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482435.htm\"><strong>transceiver QSFP+ 40G FR4<br><\/strong><\/a>, un componente chiave per le moderne applicazioni<br> <strong>Ethernet 40G<\/strong> e Fibre Channel.<br>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2699\ufe0f Analisi del nome: QSFP+ 40G FR4<br><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Iniziamo decodificando il nome stesso, che ne rivela le caratteristiche fondamentali:<br><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>QSFP+<\/strong>: sta per<br> <strong>Quad (Q) Small Form-factor Pluggable Plus<br><\/strong>. Ci\u00f2 significa che si tratta di un modulo compatto e hot-pluggable in grado di supportare<br> <strong>quattro canali indipendenti<br><\/strong> di trasmissione e ricezione dati. \u00c8 un\u2019evoluzione del fattore di forma SFP+, progettato per densit\u00e0 e velocit\u00e0 pi\u00f9 elevate.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>40G<\/strong>: Indica la velocit\u00e0 dati totale del modulo, pari a<br> <strong>40 gigabit al secondo<br><\/strong>. Con quattro canali, ciascuno opera a 10 Gbps.<br>.<\/p><\/li><li><p style=\"margin: 0px 0px 8px;\"><strong>FR<\/strong>: sta per<br> <strong>Multiplexing a divisione di lunghezza d\u2019onda grossolana a 4 lunghezze d\u2019onda (4-Wavelength Coarse Wavelength Division Multiplexing)<br> <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-cwdm-understanding-coarse-wavelength-division-multiplexing\/\"><strong>(CWDM)<\/strong><\/a>. Utilizza quattro segnali laser distinti a lunghezze d\u2019onda specifiche (1271 nm, 1291 nm, 1311 nm e 1331 nm) trasmessi su una<br><strong> Fibra monomodale <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/what-is-single-mode-fiber-and-how-does-it-work\/\"><strong>(SMF)<\/strong><\/a>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>4<\/strong>: Rappresenta i<br> <strong>4 canali<br><\/strong> da 10 G, che vengono multiplati per creare un singolo collegamento da 40 G.<br>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2699\ufe0f Come funziona un transceiver QSFP+ 40G FR4?<br><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Il funzionamento di FR4 si basa sulla tecnologia CWDM. \u00c8 fondamentale comprendere che un<br> <strong>singolo modulo QSFP+ 40G FR4 \u00e8 unidirezionale<br><\/strong>\u2014trasmette o riceve il segnale multiplato. Un collegamento completo richiede due moduli: uno a ciascuna estremit\u00e0 del collegamento in fibra.<br>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Di seguito una spiegazione semplificata del processo di comunicazione tra due switch:<br><\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p style=\"margin: 0px 0px 8px;\"><strong>Estremit\u00e0 di trasmissione (Switch A):<br><\/strong><\/p><ul><li><p style=\"margin: 0px;\">Il transceiver (<br><strong>LINK-PP <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482435.htm\"><strong>LQ-CW40-FR4C<\/strong><\/a>) riceve quattro lane elettriche da 10 G provenienti dallo Switch A.<br>.<\/p><\/li><li><p style=\"margin: 0px;\">Quattro laser separati a retroazione distribuita (DFB)<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/dfb-laser-definition\/\"><strong>convertono ciascun segnale elettrico in una specifica lunghezza d\u2019onda ottica (1271 nm, 1291 nm, 1311 nm, 1331 nm).<\/strong><\/a> convert each electrical signal into a specific optical wavelength (1271nm, 1291nm, 1311nm, 1331nm).<\/p><\/li><li><p style=\"margin: 0px;\">Un multiplexer (MUX) integrato combina questi quattro segnali ottici su un singolo filamento di fibra monomodale (SMF) per la trasmissione.<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 8px;\"><strong>Trasmissione su fibra:<\/strong><\/p><ul><li><p style=\"margin: 0px;\">Il segnale CWDM combinato viaggia lungo il cavo in fibra ottica monomodale (un filamento di trasmissione).<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 8px;\"><strong>All\u2019estremit\u00e0 di ricezione (Switch B):<\/strong><\/p><ul><li><p style=\"margin: 0px;\">Un altro <strong>LINK-PP LQ-CW40-FR4C<\/strong> modulo riceve il segnale combinato su un filamento di fibra separato.<\/p><\/li><li><p style=\"margin: 0px;\">Un demultiplexer (DEMUX) integrato separa le quattro lunghezze d\u2019onda in ingresso.<\/p><\/li><li><p style=\"margin: 0px;\">I fotorivelatori convertono ciascuna lunghezza d\u2019onda ottica nuovamente in un segnale elettrico, fornendo quattro corsie da 10G allo Switch B.<\/p><\/li><\/ul><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Questo processo avviene in senso inverso per la comunicazione dallo Switch B allo Switch A, richiedendo una seconda coppia di fibre. Pertanto, un collegamento <strong>full-duplex da 40G richiede due filamenti di fibra monomodale (SMF)<\/strong> (uno per Tx\/Rx e uno per Rx\/Tx).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2699\ufe0f QSFP+ 40G FR4 vs. SR4: Tabella di confronto rapido<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La scelta dell\u2019ottica appropriata dipende dal tipo di fibra e dai requisiti di distanza. Il principale concorrente dell\u2019FR4 \u00e8 lo <strong>QSFP+ 40G SR4<br><\/strong>, progettato per fibra multimodale.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Caratteristica<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482435.htm\"><strong>QSFP+ 40G FR4<br><\/strong><\/a><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482749.htm\"><strong>QSFP+ 40G SR4<br><\/strong><\/a><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Tipo di fibra<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Fibra monomodale (SMF)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibra multimodale (MMF \u2013 OM3\/OM4)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Reach<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Portata fino a <strong>2 chilometri<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fino a 100 m (OM3) \/ 150 m (OM4)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Tecnologia<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>CWDM (4 lunghezze d\u2019onda su 1 fibra)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Ottica parallela (4 fibre indipendenti)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Connettore<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>LC duplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Connettore MTP\/MPO da 12 fibre<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Caso d'uso principale<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Collegamenti dati a lunga portata nel data center, DCI<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Collegamenti a corta portata all\u2019interno di un rack o di un\u2019area dati<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Costo della fibra<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Pi\u00f9 elevato (SMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Inferiore (MMF)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Densit\u00e0 cablaggio<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Alto<\/strong> (Utilizza solo 2 fibre per collegamento)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Inferiore (Richiede 8 fibre per collegamento)<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Considerazione chiave:<\/strong> Utilizza <strong>SR4<\/strong> per percorsi brevi ed economici all\u2019interno del proprio data center. Utilizzare <strong>FR4<\/strong> quando \u00e8 necessario coprire distanze pi\u00f9 lunghe (fino a 2 km) tra edifici o su un ampio campus, oppure quando si desidera risparmiare preziosi filamenti di fibra.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2699\ufe0f Applicazioni chiave e vantaggi dei moduli 40G FR4<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>transceiver QSFP+ 40G FR4<br><\/strong> \u00e8 una soluzione versatile per gli architetti di rete moderni.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Interconnessione tra data center (DCI):<\/strong> Ideale per collegare due data center distanti fino a 2 km.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Collegamenti 40G ad alta densit\u00e0 tra switch:<\/strong> Perfetto per creare collegamenti dorsali ad alta velocit\u00e0 tra switch situati in diverse parti di un edificio o di un campus.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Massimizzazione dell\u2019infrastruttura in fibra:<\/strong> La sua capacit\u00e0 di trasportare 40G su soli due filamenti di SMF lo rende estremamente efficiente, posticipando la necessit\u00e0 di costose nuove posature di fibra.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Integrazione nei sistemi CWDM:<\/strong> Pu\u00f2 essere facilmente integrato nell\u2019infrastruttura CWDM esistente per una progettazione flessibile della rete.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2699\ufe0f Cerchi una soluzione 40G FR4 affidabile? Scopri LINK-PP<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7a9b7841c49a4c24b14e5016ad88b1a2.webp\" alt=\"QSFP+ 40G FR4 optical transceiver\" class=\"wp-image-5124\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7a9b7841c49a4c24b14e5016ad88b1a2.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7a9b7841c49a4c24b14e5016ad88b1a2-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7a9b7841c49a4c24b14e5016ad88b1a2-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7a9b7841c49a4c24b14e5016ad88b1a2-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7a9b7841c49a4c24b14e5016ad88b1a2-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Quando le prestazioni e l\u2019uptime della rete sono fondamentali, la scelta di un transceiver di alta qualit\u00e0 e compatibile \u00e8 obbligatoria. <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/page\/aboutus.htm\"><strong>LINK-PP<\/strong><\/a> produce una gamma di <strong>conforme allo standard MSA<\/strong> transceiver ottici noti per la loro affidabilit\u00e0, prestazioni ed elevata compatibilit\u00e0 con gli switch OEM principali di Cisco, Juniper, Arista e altri.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Per il tuo <strong>40G QSFP+ FR4<\/strong> abbiamo selezionato il seguente prodotto:<br\/><strong>LINK-PP LQ-CW40-FR4C<\/strong><br\/>Questo modulo \u00e8 sottoposto a test rigorosi per garantire piena interoperabilit\u00e0 ed \u00e8 coperto da garanzia a vita, offrendoti tranquillit\u00e0 per i collegamenti di rete critici.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>&gt; &gt; <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/file\/datasheet\/lq-cw40-fr4c.pdf\"><strong>Scopri la scheda tecnica del LINK-PP LQ-CW40-FR4C<\/strong><\/a><strong> &lt;&lt;<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2699\ufe0f Conclusione<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482435.htm\"><strong>transceiver QSFP+ 40G FR4<br><\/strong><\/a> \u00e8 una soluzione sofisticata ed efficiente per reti ad alte prestazioni su distanze medie. Il suo intelligente utilizzo della tecnologia CWDM su fibra monomodale lo rende uno strumento indispensabile per <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/data-center-interconnect-definition-benefits-and-role-of-optical-modules\/\"><strong>data center (DCI)<\/strong><\/a>, massimizzando le risorse in fibra gi\u00e0 esistenti e realizzando infrastrutture di rete scalabili.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Comprendendo il suo ruolo e confrontandolo con SR4, \u00e8 possibile prendere una decisione informata che ottimizzi sia le prestazioni sia i costi per la propria implementazione Ethernet 40G.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2699\ufe0f Domande frequenti (FAQ)<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Che cosa significa QSFP+ 40G FR4?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Si vede \u201cqsfp+\u201d come un tipo di trasmettitore-ricevitore. \u201c40g\u201d indica la velocit\u00e0, pari a 40 gigabit al secondo. \u201cfr4\u201d significa che utilizza quattro lunghezze d\u2019onda su fibra monomodale.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Quali dispositivi sono compatibili con QSFP+ 40G FR4?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c8 possibile utilizzare qsfp+ 40g fr4 in molti switch e server di rete. La maggior parte delle apparecchiature moderne dotate di porte QSFP+ supporta questo trasmettitore-ricevitore.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Qual \u00e8 la distanza massima supportata da QSFP+ 40G FR4?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c8 possibile collegare dispositivi distanti fino a 2 chilometri. Questa portata risulta particolarmente adatta a grandi data center e edifici aziendali.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Quale tipo di fibra \u00e8 necessario per QSFP+ 40G FR4?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c8 necessaria fibra monomodale. Questo tipo di cavo consente di trasmettere dati su lunghe distanze senza perdita di qualit\u00e0.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >In che cosa si differenzia QSFP+ 40G FR4 dai trasmettitori-ricevitori pi\u00f9 vecchi?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Si ottengono maggiore velocit\u00e0, portata pi\u00f9 estesa ed efficienza superiore. Le dimensioni ridotte consentono di risparmiare spazio e potenza negli armadi di rete.<\/p>","protected":false},"excerpt":{"rendered":"<p>Il modulo qsfp+ 40g FR4 offre trasmissione dati ad alta velocit\u00e0 e a lunga portata per reti moderne, migliorando prestazioni, efficienza e scalabilit\u00e0 futura nei data center.<\/p>","protected":false},"author":1,"featured_media":5123,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[18],"class_list":["post-5125","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-40g-qsfp-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/5125","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/comments?post=5125"}],"version-history":[{"count":5,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/5125\/revisions"}],"predecessor-version":[{"id":11153,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/5125\/revisions\/11153"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media\/5123"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media?parent=5125"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/categories?post=5125"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/tags?post=5125"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}