{"id":5040,"date":"2025-09-16T11:12:00","date_gmt":"2025-09-16T11:12:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/sff-transceiver-vs-1x9-transceiver-comparison-guide\/"},"modified":"2026-06-22T09:05:33","modified_gmt":"2026-06-22T09:05:33","slug":"sff-transceiver-vs-1x9-transceiver-comparison-guide","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/sff-transceiver-vs-1x9-transceiver-comparison-guide","title":{"rendered":"Transceiver SFF rispetto a 1\u00d79: una guida alle fibre ottiche legacy"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1312\" height=\"736\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3577e951f87e44bea06c7d67db2922bf.webp\" alt=\"SFF Transceiver vs 1X9 Transceiver\" class=\"wp-image-5038\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3577e951f87e44bea06c7d67db2922bf.webp 1312w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3577e951f87e44bea06c7d67db2922bf-300x168.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3577e951f87e44bea06c7d67db2922bf-1024x574.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3577e951f87e44bea06c7d67db2922bf-768x431.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3577e951f87e44bea06c7d67db2922bf-18x10.webp 18w\" sizes=\"(max-width: 1312px) 100vw, 1312px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Navigare nel mondo delle <strong>infrastruttura in fibra ottica obsoleta<\/strong> pu\u00f2 essere un\u2019operazione complessa. Tra i vari componenti, due formati di trascevitori saldati generano spesso confusione: il <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/understanding-what-is-sff-transceiver\/\"><strong>SFF (Fattore di forma ridotto)<\/strong><\/a> e la <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/1x9-transceiver-optical-network-guide\/\"><strong>trascevitore 1\u00d79<\/strong><\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sebbene le moderne <strong>ottiche hot-pluggable<\/strong> come SFP e QSFP dominino attualmente i data center, comprendere queste tecnologie pi\u00f9 vecchie, montate direttamente sulla scheda, \u00e8 fondamentale per la manutenzione e l\u2019aggiornamento delle attrezzature di rete esistenti. Questa guida distinguer\u00e0 chiaramente tra moduli SFF e 1\u00d79, evidenziandone le principali differenze per aiutarvi a prendere decisioni informate riguardo alle esigenze della vostra rete obsoleta.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Il classico lavoro quotidiano: il trascevitore 1\u00d79<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-30686-1x9-optical-transceiver.htm\"><strong>trascevitore 1\u00d79<\/strong><\/a> \u00e8 uno dei primi formati standardizzati di modulo ottico. Il suo nome deriva dall\u2019interfaccia fisica: una singola fila di <strong>9 pin<\/strong> per la saldatura diretta sulla scheda madre del sistema <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-pcb-printed-circuit-board\/\"><strong>(PCB)<\/strong><\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caratteristiche principali del 1\u00d79:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Progettazione montata sulla scheda:<\/strong> Si tratta di un <strong>modulo da saldare<\/strong>, fissato in modo permanente alla scheda ospite. Non \u00e8 inseribile n\u00e9 sostituibile a caldo.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Ingombro maggiore:<\/strong> \u00c8 relativamente ingombrante secondo gli standard moderni, con conseguente densit\u00e0 di porte inferiore su una scheda di linea.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Funzionalit\u00e0 semplice:<\/strong> Supporta tipicamente funzioni essenziali con diagnosi limitate, spesso solo un\u2019uscita di perdita di segnale (LOS).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Applicazioni principali:<\/strong> Presente prevalentemente in apparecchiature di rete molto vecchie, come hub, switch e router, che supportano <strong>Fast Ethernet (100BASE-FX)<\/strong> and <strong>Fibre Channel 1G\/2G<\/strong>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 L\u2019innovatore della densit\u00e0: il trascevitore SFF<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-30687-sff-optical-transceiver.htm\"><strong>trascevitore SFF (Small Form-Factor)<\/strong><\/a> \u00e8 stato sviluppato come successore del 1\u00d79 per risolvere i suoi limiti di dimensioni e densit\u00e0. \u00c8 fondamentale notare che anche il <strong>SFF \u00e8 un modulo da saldare<\/strong>. \u00c8 stato progettato per essere pi\u00f9 piccolo e aprire la strada a funzionalit\u00e0 pi\u00f9 avanzate, portando successivamente alla creazione dello standard <em>inseribile<\/em> SFP (Small Form-factor Pluggable).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caratteristiche principali del SFF:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Saldato, ma pi\u00f9 piccolo:<\/strong> Come il 1\u00d79, anche il SFF \u00e8 <strong>saldato sulla PCB<\/strong>, ma il suo ingombro fisico \u00e8 significativamente ridotto (ad esempio, con configurazioni di pin <strong>2\u00d75, 2\u00d77 o 2\u00d710<\/strong>), consentendo una maggiore densit\u00e0 di porte.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Funzionalit\u00e0 avanzate:<\/strong> Molti moduli SFF integravano il supporto per <strong>Digital Diagnostic Monitoring <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/ddm-dom-in-optical-transceivers\/\"><strong>(DDM o DOM)<\/strong><\/a> secondo lo standard SFF-8472 MSA, fornendo dati in tempo reale essenziali su temperatura, potenza ottica e corrente di polarizzazione del laser.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Applicazioni principali:<\/strong> \u00c8 diventato lo standard per i moduli montati sulla scheda nelle applicazioni <strong>Gigabit Ethernet (1000BASE-SX\/LX\/ZX)<\/strong> su switch, router e schede di interfaccia di rete (NIC), prima dell\u2019adozione diffusa dell\u2019SFP.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Confronto dettagliato tra SFF e 1\u00d79<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1312\" height=\"736\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/928ad0ba2a1348948063d1bf6c9ea491.webp\" alt=\"SFF vs 1x9\" class=\"wp-image-5039\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/928ad0ba2a1348948063d1bf6c9ea491.webp 1312w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/928ad0ba2a1348948063d1bf6c9ea491-300x168.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/928ad0ba2a1348948063d1bf6c9ea491-1024x574.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/928ad0ba2a1348948063d1bf6c9ea491-768x431.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/928ad0ba2a1348948063d1bf6c9ea491-18x10.webp 18w\" sizes=\"(max-width: 1312px) 100vw, 1312px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">La tabella seguente fornisce un chiaro confronto affiancato di questi due formati obsoleti.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Caratteristica<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Trascevitore SFF<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Trascevitore 1\u00d79<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Forma fisica<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Small Form-Factor (ad es. pin 2\u00d75, 2\u00d77)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Singola fila di 9 pin<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Tipo di collegamento<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Saldato sulla PCB<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Saldato sulla PCB<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Hot-pluggable<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u274c No<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u274c No<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Densit\u00e0 di porte<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2705 <strong>Alto<\/strong> (grazie alle dimensioni ridotte)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u274c <strong>Bassa<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Velocit\u00e0 dati tipiche<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fast Ethernet, <strong>Ethernet Gigabit<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fast Ethernet, Fibre Channel<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Diagnostica digitale (DDM\/DOM)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2705 Spesso supportata<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u274c Raramente supportata<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Rilevanza attuale<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Presente in apparecchiature legacy successive<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Presente in apparecchiature legacy pi\u00f9 vecchie<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Scelta del modulo adatto alla vostra applicazione<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La vostra scelta dipende quasi interamente dall\u2019hardware con cui state lavorando.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Avete bisogno di un trascevitore 1\u00d79 se:<\/strong> state riparando o mantenendo apparecchiature legacy molto vecchie progettate originariamente con pin 1\u00d79 saldati sulla scheda madre.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Avete bisogno di un trascevitore SFF se:<\/strong> la scheda madre del vostro dispositivo presenta i footprint per la specifica configurazione di pin SFF (ad es. 2\u00d75 o 2\u00d77). Ad esempio, un <strong>LINK-PP LF5-MM851G-S5IDS<\/strong> sarebbe una scelta perfetta e affidabile per un\u2019applicazione Gigabit multimodale che richiede un <strong>modulo da saldare con pin 2\u00d75<\/strong>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Manutenzione sicura dei sistemi legacy<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Comprendere la distinzione tra questi formati saldati \u00e8 fondamentale per una manutenzione efficace della rete. Reperire moduli di alta qualit\u00e0 e compatibili \u00e8 essenziale per garantire affidabilit\u00e0.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/page\/aboutus.htm\"><strong>LINK-PP<\/strong><\/a> offre componenti ottici conformi allo standard MSA, inclusi formati legacy come <strong>moduli SFF<\/strong>. Con un impegno costante verso qualit\u00e0 e prestazioni, <strong>LINK-PP<\/strong> garantisce che la vostra infrastruttura legacy rimanga operativa ed efficiente.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\ud83d\udc49 Cercate una fonte affidabile per trascevitori legacy SFF o 1\u00d79?<\/strong> <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/page\/contactus.htm\"><strong>Contatta oggi stesso gli esperti LINK-PP<\/strong><\/a> per un controllo di compatibilit\u00e0 e assistenza tecnica. Lasciate che vi aiutiamo a mantenere la vostra rete in funzione senza interruzioni.<\/p>","protected":false},"excerpt":{"rendered":"<p>This guide clarifies the differences between soldered SFF and 1&#215;9 transceiver form factors. Learn their specs, applications, and how to choose for your network.<\/p>","protected":false},"author":1,"featured_media":5038,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[26],"class_list":["post-5040","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/5040","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/comments?post=5040"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/5040\/revisions"}],"predecessor-version":[{"id":11373,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/5040\/revisions\/11373"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media\/5038"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media?parent=5040"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/categories?post=5040"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/tags?post=5040"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}