{"id":3818,"date":"2025-09-03T00:00:00","date_gmt":"2025-09-03T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/glossary\/mode-conditioning-patch-cables-how-they-work-in-networks\/"},"modified":"2026-06-22T07:47:30","modified_gmt":"2026-06-22T07:47:30","slug":"mode-conditioning-patch-cables-how-they-work-in-networks","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/mode-conditioning-patch-cables-how-they-work-in-networks","title":{"rendered":"Cos\u2019\u00e8 un cavo patch per condizionamento della modalit\u00e0 e come funziona"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f.webp\" alt=\"What Are Mode Conditioning Patch Cables\" class=\"wp-image-3815\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Hai mai installato un transceiver ottico Gigabit LX o 10G LR e riscontrato errori inaspettati, elevata attenuazione o collegamenti instabili? La causa potrebbe non essere il tuo equipaggiamento, ma una fondamentale incompatibilit\u00e0 tra i tipi di cavo in fibra ottica utilizzati. \u00c8 qui che entra in gioco un piccolo ma potente eroe: il <strong>cavo patch per condizionamento della modalit\u00e0 (MCP)<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In questa guida, chiariremo <strong>cos\u2019\u00e8 un cavo patch per condizionamento della modalit\u00e0<\/strong>, perch\u00e9 \u00e8 essenziale in determinati scenari di rete e come pu\u00f2 salvarti da una miriade di problemi di connettivit\u00e0. Esploreremo inoltre come interagisce con componenti ad alte prestazioni come <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>I transceiver ottici LINK-PP<\/strong><\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Punti Chiave<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>I cavi patch per condizionamento della modalit\u00e0<\/strong> consentono ai dispositivi monomodali di utilizzare fibre multimodali. Risolvono problemi di segnale come il ritardo differenziale tra le modalit\u00e0.<\/p><\/li><li><p>Questi cavi migliorano il segnale e riducono gli errori. Ci\u00f2 rende le reti pi\u00f9 veloci e affidabili, in particolare per Ethernet Gigabit.<\/p><\/li><li><p>I cavi presentano una sezione speciale monomodale che sposta il segnale luminoso per ridurre la distorsione e migliorare il trasferimento dei dati.<\/p><\/li><li><p>Collegare sempre l\u2019estremit\u00e0 monomodale al transceiver e l\u2019estremit\u00e0 multimodale all\u2019impianto in fibra per evitare problemi di rete.<\/p><\/li><li><p>Pulire i connettori prima dell\u2019uso. Non piegare i cavi bruscamente. Verificare la connessione dopo l\u2019installazione per mantenere la rete performante.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Perch\u00e9 abbiamo bisogno di un \u201ccavo speciale\u201d? Il problema multimodale vs. monomodale<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Per comprendere la soluzione, dobbiamo prima analizzare il problema. I cavi in fibra ottica sono principalmente di due tipi:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/om1-om2-om3-om4-om5-multimode-fiber-guide\/\"><strong>Fibra multimodale (MMF)<\/strong><\/a><strong>:<\/strong> Ha un nucleo pi\u00f9 grande, che consente a pi\u00f9 modalit\u00e0 luminose (percorsi) di propagarsi. \u00c8 progettato per applicazioni a breve distanza e ad alta larghezza di banda all\u2019interno di edifici o campus. I tipi pi\u00f9 comuni sono <strong>OM1, OM2, OM3 e OM4<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/what-is-single-mode-fiber-and-how-does-it-work\/\"><strong>Fibra monomodale (SMF)<\/strong><\/a><strong>:<\/strong> Ha un nucleo molto pi\u00f9 piccolo, che consente la propagazione di una sola modalit\u00e0 luminosa in linea retta. \u00c8 progettato per comunicazioni su lunga distanza, ad esempio tra citt\u00e0.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Il problema sorge quando si tenta di collegare un <strong>transceiver a lunga portata (LX\/LR)<\/strong> (progettato per fibre monomodali, SMF) a una <strong>Fibra multimodale (MMF)<\/strong> impianto di cavi. Questo \u00e8 comune negli edifici obsoleti cablati con fibre multimodali (MMF) che devono connettersi a un nuovo backbone in fibra monomodale (SMF).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La luce laser del transceiver LX\/LR entra nel grande nucleo della fibra multimodale (MMF). Ci\u00f2 pu\u00f2 causare un fenomeno denominato <strong>Ritardo differenziale di modo (DMD)<\/strong>, in cui gli impulsi luminosi si allargano e si distorcono durante la propagazione, causando jitter, errori e addirittura il completo guasto del collegamento. Ci\u00f2 risulta particolarmente problematico con <strong>fibre OM3 e OM4<\/strong> and <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475586.htm\"><strong>moduli 10G LR<\/strong><\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Come funziona un cavo patch di condizionamento del modo?<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"318\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028.webp\" alt=\"Mode Conditioning Patch Cables\" class=\"wp-image-3816\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028-300x80.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028-1024x271.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028-768x204.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028-18x5.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">A <strong>Cavo patch di condizionamento della modalit\u00e0<\/strong> \u00e8 un jumper in fibra duplex <strong>progettato con intelligenza<\/strong> per risolvere questa incompatibilit\u00e0 a livello fisico. \u00c8 talvolta chiamato <em>jumper di condizionamento del modo<\/em>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Il suo funzionamento dipende dalla sua costruzione sul lato di trasmissione (Tx):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\">Un braccio del cavo \u00e8 un connettore standard in <strong>fibra monomodale<\/strong> che si inserisce nel vostro transceiver.<\/p><\/li><li><p style=\"margin: 0px;\">L\u2019altro braccio \u00e8 un <strong>connettore multimodale<\/strong> con una saldatura a fusione sfalsata precisa, posizionata a pochi metri dall\u2019estremit\u00e0.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Questa struttura costringe la luce laser a percorrere inizialmente una breve distanza su fibra monomodale. Successivamente, essa viene iniettata in modo mirato nella <strong>parte centrale del nucleo della fibra multimodale<\/strong> nel punto di saldatura. Quando il segnale entra nell\u2019impianto di cavi MMF esistente, esso risulta gi\u00e0 stabilizzato, eliminando efficacemente l\u2019effetto DMD e consentendo una trasmissione dati pulita e affidabile.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Applicazioni principali e casi d\u2019uso:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\">Connettendo <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476763.htm\"><strong>modulo SFP 1000BASE-LX<\/strong><\/a> a <strong>fibre multimodali OM1\/OM2\/OM3<\/strong> .<\/p><\/li><li><p style=\"margin: 0px;\">Connettendo <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475586.htm\"><strong>moduli SFP+ 10GBASE-LR<\/strong><\/a> a <strong>OM3\/OM4<\/strong> .<\/p><\/li><li><p style=\"margin: 0px;\">Estensione della portata dei transceiver LX\/LR su fibre multimodali (MMF) oltre la distanza tipica limitata dal DMD.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Confronto rapido: cavo patch di condizionamento del modo vs. cavo patch standard<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Caratteristica<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Cavo patch standard<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Cavo patch di condizionamento della modalit\u00e0<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Funzione principale<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Collega tipi di fibra identici (SMF-SMF o MMF-MMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Collega tipi di fibra diversi (transceiver SMF a cavo MMF)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Progettazione interna<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Tipo di fibra uniforme lungo tutto il cavo<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Include una precisa <strong>saldatura a fusione sfalsata<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Caso d\u2019uso<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Connessioni standard, dello stesso tipo<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Aggiornamenti di reti legacy<\/strong>, requisiti specifici del transceiver<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Impedisce il DMD?<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>No<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Yes<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Costo<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lower<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Leggermente superiore<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Integrazione con i transceiver ottici LINK-PP per prestazioni ottimali<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"719\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f.jpg\" alt=\"optical transceivers\" class=\"wp-image-3817\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f-300x180.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f-1024x614.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f-768x460.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f-18x12.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Quando si costruisce una rete affidabile e ad alte prestazioni, ogni componente deve funzionare in armonia. L\u2019uso di un cavo di condizionamento della modalit\u00e0 di qualit\u00e0 \u00e8 fondamentale per sbloccare il pieno potenziale del proprio <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>transceiver ottici<\/strong><\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ad esempio, se si utilizza un <strong>LINK-PP <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475586.htm\"><strong>SFP-10G-LR<br><\/strong><\/a> modulo per collegarsi a un\u2019esistente dorsale multimodale OM3, un cavo patch di condizionamento della modalit\u00e0 non \u00e8 solo raccomandato; spesso \u00e8 obbligatorio per garantire un collegamento stabile. Lo stesso vale per un<strong> <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476763.htm\"><strong>SFP-1G-LX<\/strong><\/a> modulo su un vecchio cavo OM1.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Consiglio professionale:<\/strong> Controllare sempre il datasheet del proprio <strong>trasceiver compatibile LINK-PP<\/strong>. Indicher\u00e0 il tipo di fibra richiesto e spesso menzioner\u00e0 esplicitamente la necessit\u00e0 di un cavo patch di condizionamento della modalit\u00e0 quando ci si collega a fibre multimodali (MMF). L\u2019implementazione corretta di questa configurazione \u00e8 una best practice per la <strong>affidabilit\u00e0 della rete<\/strong> e per ridurre al minimo i <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/understanding-what-is-bit-error-rate\/\"><strong>tassi di errore sul bit (BER)<\/strong><\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 \u00c8 necessario? Punti chiave<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>\u00c8 necessario un cavo patch di condizionamento della modalit\u00e0 se:<\/strong> Si collega un <strong>transceiver a lunga distanza (LX, LR, ER)<\/strong> SFP, SFP+ o GBIC a un <strong>Fibra multimodale (MMF)<\/strong> tratto di cavo.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Non \u00e8 necessario se:<\/strong> Si collega un transceiver allo stesso tipo di fibra per cui \u00e8 stato progettato (ad esempio, LX a fibra monomodale SMF oppure SX a fibra multimodale MMF).<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Investire nella giusta infrastruttura cablata garantisce che la rete funzioni in modo efficiente, riduce i tempi di inattivit\u00e0 e protegge l\u2019investimento in hardware di qualit\u00e0 come <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>moduli ottici LINK-PP<\/strong><\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Domande frequenti<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Qual \u00e8 la funzione principale di un cavo patch per il condizionamento della modalit\u00e0?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un cavo patch per il condizionamento della modalit\u00e0 consente ai trascevitori in fibra monomodale di funzionare con fibre multimodali. Aiuta a ridurre i problemi di segnale come il ritardo differenziale di modalit\u00e0. Ci\u00f2 garantisce il flusso regolare dei dati nelle reti con fibre miste.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00c8 possibile utilizzare un cavo patch per il condizionamento della modalit\u00e0 con qualsiasi sistema ottico in fibra?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No, questi cavi funzionano al meglio quando si collegano dispositivi in fibra monomodale a fibre multimodali. Non sono utili nei sistemi che impiegano esclusivamente fibra monomodale o esclusivamente fibra multimodale.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Come si riconosce quale estremit\u00e0 del cavo \u00e8 monomodale?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La maggior parte dei cavi presenta un connettore giallo o un\u2019etichetta sull\u2019estremit\u00e0 monomodale. Gli utenti devono sempre verificare tali indicazioni prima di collegare il cavo.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Cosa succede se il cavo viene installato al contrario?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Se qualcuno collega il cavo in modo invertito, la rete potrebbe non funzionare. Il segnale potrebbe indebolirsi o andare perso. Collegare sempre l\u2019estremit\u00e0 monomodale al trascevitore.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >I cavi patch per il condizionamento della modalit\u00e0 supportano reti ad alta velocit\u00e0?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00ec, questi cavi supportano collegamenti ad alta velocit\u00e0 come Gigabit Ethernet e 10 Gigabit Ethernet. Contribuiscono a mantenere i segnali chiari e forti nelle reti veloci.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Consiglio: testare sempre il collegamento dopo aver installato un cavo patch per il condizionamento della modalit\u00e0 per assicurarsi che la connessione funzioni correttamente.<\/p><\/blockquote>","protected":false},"excerpt":{"rendered":"<p>I cavi patch per condizionamento della modalit\u00e0 consentono ai dispositivi monomodali di funzionare con fibre multimodali, riducendo la distorsione del segnale e il ritardo differenziale di modalit\u00e0 nelle reti.<\/p>","protected":false},"author":1,"featured_media":3815,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[27],"tags":[26],"class_list":["post-3818","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-glossary","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/3818","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/comments?post=3818"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/3818\/revisions"}],"predecessor-version":[{"id":11185,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/3818\/revisions\/11185"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media\/3815"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media?parent=3818"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/categories?post=3818"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/tags?post=3818"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}