{"id":3741,"date":"2025-11-21T00:00:00","date_gmt":"2025-11-21T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/scalable-spine-leaf-fabric-high-density-optical-transceivers\/"},"modified":"2026-05-26T06:23:30","modified_gmt":"2026-05-26T06:23:30","slug":"scalable-spine-leaf-fabric-high-density-optical-transceivers","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/scalable-spine-leaf-fabric-high-density-optical-transceivers","title":{"rendered":"Costruire una rete spine-leaf scalabile e il ruolo dei transceiver ottici ad alta densit\u00e0"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9d8679d2ef814cd08c89a686bd5dd9b1.webp\" alt=\"Building a Scalable Spine-Leaf Fabric and the Role of High-Density Optical Transceivers\" class=\"wp-image-3739\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9d8679d2ef814cd08c89a686bd5dd9b1.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9d8679d2ef814cd08c89a686bd5dd9b1-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9d8679d2ef814cd08c89a686bd5dd9b1-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9d8679d2ef814cd08c89a686bd5dd9b1-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9d8679d2ef814cd08c89a686bd5dd9b1-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Nell\u2019era del cloud computing, dell\u2019intelligenza artificiale e dell\u2019analisi in tempo reale, la tradizionale rete data center a tre livelli cede sotto la pressione. Per ottenere la bassa latenza, l\u2019elevata larghezza di banda e la scalabilit\u00e0 senza sforzo richieste dalle applicazioni moderne, gli architetti si sono rivolti alla <strong>topologia a rete spine-leaf<\/strong>. Ma cosa rende veramente viva questa elegante architettura? La risposta risiede negli eroi silenziosi del data center: <strong>interruttori ad alta densit\u00e0 <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>trasceivers ottici<\/strong><\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Questo articolo approfondisce il motivo per cui questi piccoli componenti rappresentano il perno critico per costruire una rete data center robusta e scalabile.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Punti Chiave<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Scopri di pi\u00f9 su <strong>architettura spine-leaf<\/strong>. Semplifica i percorsi di rete. Puoi espanderti facilmente collegando ogni switch leaf a tutti gli switch spine.<\/p><\/li><li><p>Scegli gli switch e le porte giusti. Gli switch ad alta densit\u00e0 occupano meno spazio e offrono maggiore larghezza di banda. Ci\u00f2 favorisce una crescita efficiente della tua rete.<\/p><\/li><li><p>Pensa alla crescita futura. Lascia alcune porte libere. Utilizza switch modulari per aggiungere altri dispositivi in seguito. Puoi aggiungere connessioni man mano che le tue esigenze cambiano.<\/p><\/li><li><p>Usa transceiver ottici ad alta densit\u00e0. Aumentano la larghezza di banda e riducono il disordine dei cavi. Gli aggiornamenti risultano pi\u00f9 semplici. La tua rete rimane veloce e funziona correttamente.<\/p><\/li><li><p>Applica le best practice durante la configurazione. Tieni i cavi ordinati. Monitora le prestazioni della tua rete. Assicurati che tutti i componenti operino in sinergia. Ci\u00f2 garantisce una rete solida e facilmente scalabile.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Che cos\u2019\u00e8 un\u2019architettura spine-leaf?<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Prima di addentrarci nell\u2019hardware, chiariamo le basi. Un\u2019architettura spine-leaf, nota anche come rete Clos, \u00e8 una progettazione a due livelli che elimina i colli di bottiglia dei modelli gerarchici obsoleti.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Switch leaf (livello di accesso):<\/strong> Ogni switch leaf \u00e8 connesso a tutti gli switch spine. Questi costituiscono i punti di accesso ai quali server, sistemi di storage e altri endpoint si collegano alla rete.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Switch spine (La struttura portante):<\/strong> Gli switch spine formano il nucleo della rete. Il loro unico scopo \u00e8 interconnettere tutti gli switch leaf.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Questo design garantisce che qualsiasi server possa comunicare con qualsiasi altro server in soli due hop: attraverso un leaf, fino a uno spine e quindi verso un altro leaf. Ci\u00f2 comporta una latenza bassa e prevedibile e una rete non bloccante, in cui la larghezza di banda pu\u00f2 essere scalata semplicemente aggiungendo ulteriori switch spine o leaf. Per le organizzazioni che intendono implementare una<br> <strong>progettazione di data center a prova di futuro<br><\/strong>, questa topologia non \u00e8 pi\u00f9 opzionale; \u00e8 essenziale.<br>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 L\u2019imperativo della scalabilit\u00e0 nei moderni data center<br><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le forze trainanti del passaggio alla topologia spine-leaf sono implacabili. I carichi di lavoro stanno diventando sempre pi\u00f9 dinamici e il traffico east-west (comunicazione tra server all\u2019interno del data center) domina ormai quello north-south.<br>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I principali fattori trainanti includono:<br><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Infrastruttura iperconvergente (HCI):<br><\/strong> Richiede connessioni ad alta larghezza di banda e bassa latenza tra i nodi.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Intelligenza artificiale e apprendimento automatico (AI\/ML):<br><\/strong> I cluster AI\/ML richiedono flussi di dati massicci e ininterrotti tra<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-a-gpu-graphics-processing-units\/\"><strong>GPU<\/strong><\/a>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Analisi dei Big Data:<br><\/strong> L\u2019elaborazione di enormi insiemi di dati comporta una comunicazione costante tra nodi di calcolo e di archiviazione.<br>.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Una rete scalabile non riguarda soltanto l\u2019aggiunta di ulteriori switch; si tratta piuttosto di garantire che il livello fisico\u2014cablaggio e transceiver\u2014possa supportare tale crescita senza dover effettuare una sostituzione completa. \u00c8 qui che la scelta di<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>trasmettitore ottico<\/strong><\/a><strong> <\/strong>diventa una decisione strategica.<br>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 La spina dorsale della connettivit\u00e0: transceiver ottici ad alta densit\u00e0<br><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>architettura spine-leaf<\/strong>\u2018La bellezza di <em>questo design<\/em> risiede nella sua semplicit\u00e0, ma la sua fattibilit\u00e0 dipende dalle interconnessioni. Poich\u00e9 ogni switch leaf \u00e8 collegato a tutti gli switch spine, il numero di porte fisiche e cavi cresce in modo esponenziale. \u00c8 qui che<br> <strong>i transceiver ottici ad alta densit\u00e0<br><\/strong> dimostrano il loro valore.<br>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sono fondamentali per diversi motivi:<br><\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p style=\"margin: 0px;\"><strong>Densit\u00e0 delle porte e scalabilit\u00e0:<br><\/strong> I transceiver ad alta densit\u00e0 (ad esempio QSFP-DD e OSFP) concentrano maggiore larghezza di banda in un form factor pi\u00f9 ridotto. Un singolo slot di switch pu\u00f2 gestire pi\u00f9 connessioni, consentendo di aggiungere ulteriori switch spine o leaf senza aumentare l\u2019ingombro fisico.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Requisiti di larghezza di banda:<\/strong> Poich\u00e9 gli switch di livello leaf aggregano il traffico da numerosi server, i collegamenti ascendenti verso lo spine devono gestire una larghezza di banda immensa. I transceiver moderni che supportano 100G, 400G e ora 800G sono obbligatori per evitare colli di bottiglia.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Efficienza energetica e di raffreddamento:<\/strong> I transceiver pi\u00f9 recenti sono progettati per una migliore efficienza energetica per gigabit. In una fabric con centinaia o migliaia di questi moduli, l\u2019ottimizzazione <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/power-consumption-optimization-optical-edge-computing\/\"><strong>consumo energetico<\/strong><\/a> e la dissipazione del calore sono fondamentali per le spese operative (OpEx).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Flessibilit\u00e0 e portata:<\/strong> I transceiver ottici consentono un mix di tipi di cavo (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/what-is-single-mode-fiber-and-how-does-it-work\/\"><strong>Fibra monomodale<\/strong><\/a> per portate lunghe, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/om1-om2-om3-om4-om5-multimode-fiber-guide\/\"><strong>Fibra multimodale<\/strong><\/a> per portate brevi) e distanze, offrendo la flessibilit\u00e0 necessaria in ambienti eterogenei di data center.<\/p><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">La scelta del transceiver appropriato non \u00e8 semplicemente un compito di approvvigionamento; \u00e8 parte integrante della <strong>ottimizzazione delle prestazioni del data center<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Approfondimento sui moduli ottici: alimentare la fabric<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"719\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/94c0e92ed84949c282df30a4f5cec15b.jpg\" alt=\"optical transceivers\" class=\"wp-image-3740\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/94c0e92ed84949c282df30a4f5cec15b.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/94c0e92ed84949c282df30a4f5cec15b-300x180.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/94c0e92ed84949c282df30a4f5cec15b-1024x614.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/94c0e92ed84949c282df30a4f5cec15b-768x460.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/94c0e92ed84949c282df30a4f5cec15b-18x12.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Per apprezzarne appieno il ruolo, dobbiamo esaminare pi\u00f9 da vicino i <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>Moduli ottici<\/strong><\/a> transceiver stessi. Un transceiver ottico \u00e8 un dispositivo che trasmette e riceve dati, convertendo i segnali elettrici provenienti dallo switch in segnali ottici per <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/fiber-optic-cable-what-it-is-and-how-it-works-explained\/\"><strong>cavi ottici<\/strong><\/a>, e viceversa.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Principali tipi di transceiver in una fabric spine-leaf:<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Forma fisica<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Velocit\u00e0 tipiche<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Utilizzo comune in spine-leaf<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Vantaggio chiave<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>SFP28<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>25G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Server \u2192 Leaf<\/strong> collegamenti<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Economico per il livello di accesso<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>QSFP28<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>100G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Leaf \u2192 Spine<\/strong> collegamenti di uplink<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Alta densit\u00e0, ampiamente adottato<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>QSFP-DD<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>400G, 800G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Spine \u2192 Leaf ad alta densit\u00e0<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Compatibilit\u00e0 retroattiva, a prova di futuro<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>OSFP<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>400G, 800G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Nuclei spine di nuova generazione<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Maggiore potenza per ottiche esigenti<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Quando si selezionano moduli per una rete a maglia scalabile, gli architetti di rete devono dare priorit\u00e0 all\u2019interoperabilit\u00e0, al basso consumo energetico e alle funzionalit\u00e0 diagnostiche come <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/ddm-dom-in-optical-transceivers\/\"><strong>Monitoraggio delle diagnostica digitale (DDM)<\/strong><\/a>. \u00c8 qui che fare affidamento su un fornitore tecnologico affidabile fa tutta la differenza.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ad esempio,<br>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.link-pp.com\/\"><strong>LINK-PP<\/strong><\/a> offre una serie di transceiver ottici ad alte prestazioni e conformi, progettati appositamente per ambienti spine-leaf esigenti. Una soluzione di rilievo per molte implementazioni \u00e8 il <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/470377.htm\"><strong>LINK-PP 400G-QSFP-DD-DR4<\/strong><\/a> transceiver. Questo modulo \u00e8 ideale per <strong>interconnessioni spine ad alta densit\u00e0<\/strong>, supportando 400G su 500 m di fibra monomodale con integrit\u00e0 del segnale eccezionale e basso consumo energetico. Integrando tali <strong>moduli QSFP-DD ad alta densit\u00e0<\/strong>, le aziende possono efficacemente <strong>ridurre la latenza di rete<br><\/strong> e costruire una solida base per la crescita.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Best practice per l\u2019implementazione<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Costruire una rete a maglia di successo va ben oltre l\u2019acquisto dei componenti pi\u00f9 veloci. Ecco alcune considerazioni fondamentali:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Pianificare la crescita:<\/strong> Progettare la rete a maglia iniziale con una capacit\u00e0 di porte libere pari ad almeno il 30\u201340% sia sul livello spine che su quello leaf, per consentire espansioni future.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Standardizzare i transceiver:<\/strong> L\u2019uso di moduli coerenti e indipendenti dal fornitore, provenienti da produttori come <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.link-pp.com\/\"><strong>LINK-PP<\/strong><\/a> semplifica la gestione delle scorte, riduce i problemi di compatibilit\u00e0 e abbassa i costi.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Adottare l\u2019automazione:<\/strong> Con la crescita della rete a maglia, la gestione manuale diventa impossibile. Utilizzare strumenti di automazione di rete per gestire le configurazioni e monitorare lo stato dei transceiver su migliaia di collegamenti.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Prestare attenzione alla gestione dei cavi:<\/strong> Una rete a maglia ad alta densit\u00e0 implica un campo di patching altrettanto denso. Investire in soluzioni adeguate per la gestione dei cavi garantisce un buon flusso d\u2019aria e facilita la manutenzione, elementi critici per <strong>l\u2019efficienza del data center<\/strong>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Conclusione: Garantirsi il futuro con la giusta fondazione<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Un\u2019architettura spine-leaf scalabile rappresenta la pianta definitiva per il data center moderno. Tuttavia, le sue prestazioni e la sua scalabilit\u00e0 dipendono direttamente dalla qualit\u00e0 e dalle capacit\u00e0 dei transceiver ottici che ne costituiscono il tessuto connettivo. Dando priorit\u00e0 a <strong>interruttori ad alta densit\u00e0 <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>trasceivers ottici<\/strong><\/a> fin dalle prime fasi, le organizzazioni possono costruire una rete non solo potente gi\u00e0 oggi, ma anche sufficientemente agile da abbracciare le tecnologie di domani.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Investire in componenti affidabili e ad alte prestazioni provenienti da leader del settore come <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.link-pp.com\/\"><strong>LINK-PP<\/strong><\/a> non \u00e8 un semplice accessorio: \u00e8 un imperativo strategico per realizzare una rete di data center veramente <strong>scalabile ed efficiente<\/strong>. Nella pianificazione del prossimo aggiornamento di rete, ricordate che il percorso verso una rete a maglia fluida e ad alta velocit\u00e0 \u00e8 illuminato dalle fibre ottiche.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Domande frequenti<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Che cos\u2019\u00e8 una rete a maglia spine-leaf?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Una rete a maglia spine-leaf collega server e switch all\u2019interno di un data center. Gli switch leaf sono collegati agli switch spine. Questa configurazione garantisce percorsi dati rapidi e rende facile aggiungere nuovi componenti.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Perch\u00e9 scegliere transceiver ottici ad alta densit\u00e0?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">I transceiver ottici ad alta densit\u00e0 permettono di collegare pi\u00f9 dispositivi in uno spazio ridotto. Si ottengono velocit\u00e0 superiori e si risparmia spazio negli armadi rack. La rete pu\u00f2 supportare pi\u00f9 utenti e crescere facilmente.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Come si pianifica la crescita futura della rete?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Si lasciano alcune porte libere per utilizzi successivi. Si utilizzano switch modulari che consentono di aggiungerne altri. Si scelgono cavi compatibili con gli aggiornamenti. Si monitora il traffico di rete e si aggiungono nuovi collegamenti quando necessario.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Consiglio: Verificare sempre la compatibilit\u00e0 dei propri switch con i nuovi transceiver prima dell\u2019acquisto.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >Quali problemi possono risolvere le ottiche ad alta densit\u00e0?<\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Problema<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Soluzione<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Disordine dei cavi<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Si necessitano meno cavi<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Spazio limitato negli armadi rack<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Si ottengono pi\u00f9 connessioni<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Aggiornamenti lenti<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u00c8 possibile sostituire i transceiver<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Le ottiche ad alta densit\u00e0 aiutano a ottimizzare spazio, velocit\u00e0 e aggiornamenti.<\/p>","protected":false},"excerpt":{"rendered":"<p>Costruisci una rete spine-leaf scalabile con transceiver ottici ad alta densit\u00e0 per una crescita efficiente, un\u2019ampia larghezza di banda e una semplificazione dell\u2019espansione del data center.<\/p>","protected":false},"author":1,"featured_media":3739,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13,14,17,24,26],"class_list":["post-3741","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules","tag-10g-sfp-transceivers","tag-400g-optical-modules","tag-link-pp","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/3741","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/comments?post=3741"}],"version-history":[{"count":1,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/3741\/revisions"}],"predecessor-version":[{"id":8002,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/3741\/revisions\/8002"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media\/3739"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media?parent=3741"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/categories?post=3741"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/tags?post=3741"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}