{"id":3610,"date":"2025-11-27T00:00:00","date_gmt":"2025-11-27T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/ieee-802-3bs-200g-400g-ethernet-standard\/"},"modified":"2026-06-22T04:37:48","modified_gmt":"2026-06-22T04:37:48","slug":"ieee-802-3bs-200g-400g-ethernet-standard","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/ieee-802-3bs-200g-400g-ethernet-standard","title":{"rendered":"IEEE 802.3bs spiegato: la guida definitiva agli standard Ethernet 200G\/400G"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cdadd3ca56484cc88bc0ac2f25e54134.webp\" alt=\"IEEE 802.3bs-200G\/400G Ethernet Standards\" class=\"wp-image-3606\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cdadd3ca56484cc88bc0ac2f25e54134.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cdadd3ca56484cc88bc0ac2f25e54134-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cdadd3ca56484cc88bc0ac2f25e54134-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cdadd3ca56484cc88bc0ac2f25e54134-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cdadd3ca56484cc88bc0ac2f25e54134-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">La domanda incessante di larghezza di banda, alimentata da <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/che-cose-il-cloud-computing-accesso-server-archiviazione-app-online\/\">elaborazione nel cloud<\/a>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/artificial-intelligence-what-it-is-and-how-it-works-explained\/\">AI<\/a>, insieme alle reti 5G, ha portato le interconnessioni tra i data center a velocit\u00e0 senza precedenti. Al centro di questa trasformazione c'\u00e8 <strong>IEEE 802.3bs<\/strong>, un emendamento fondamentale al quadro generale <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/ieee-802-3-ethernet-standard-explained\/\">IEEE 802.3<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ratificato nel dicembre 2017, lo standard IEEE 802.3bs ha definito in modo specifico le specifiche per <strong>Ethernet a 200 Gigabit (200GbE)<br><\/strong> and <strong>400 Gigabit Ethernet (400GbE)<\/strong>. Questo standard non \u00e8 solo un piccolo passo avanti; rappresenta un cambiamento di paradigma che rende possibile una connettivit\u00e0 ottica scalabile, efficiente dal punto di vista energetico e ad alta densit\u00e0, ormai indispensabile per gli ambienti hyperscale.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Questa guida specialistica offrir\u00e0 un'analisi approfondita degli aspetti tecnici fondamentali dello standard IEEE 802.3bs, esplorando le tecnologie alla base di tale standard e il ruolo fondamentale che esso svolge nell'evoluzione di <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26044-200-400-800g-transceiver-modules.htm\"><strong>transceiver ottici 200G\/400G<\/strong><\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u25b6 Comprendere il mandato fondamentale dello standard IEEE 802.3bs<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">L'obiettivo principale del <strong>IEEE 802.3bs<\/strong> Il compito della task force era quello di fornire <strong>livello fisico (PHY)<\/strong> specifiche e <strong>miglioramenti del livello di controllo dell\u2019accesso al mezzo (MAC)<\/strong> parametri in grado di supportare velocit\u00e0 di trasmissione dati di 200 Gb\/s e 400 Gb\/s su fibra ottica.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Per ottenere questo enorme aumento di velocit\u00e0 rispetto al precedente standard 100GbE (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/what-is-ieee-8023bm-40g-100g-ethernet-standards\/\">IEEE 802.3bm<\/a>\/cd), lo standard ha introdotto due modifiche fondamentali:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Il passaggio alla modulazione PAM4<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"939\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/237b0c2edabc4c95814384632353d425-1024x939.webp\" alt=\"4-level Pulse Amplitude Modulation (PAM4)\" class=\"wp-image-3607\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/237b0c2edabc4c95814384632353d425-1024x939.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/237b0c2edabc4c95814384632353d425-300x275.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/237b0c2edabc4c95814384632353d425-768x704.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/237b0c2edabc4c95814384632353d425-13x12.webp 13w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/237b0c2edabc4c95814384632353d425.webp 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Un fattore chiave per <strong>Ethernet 400G<\/strong> \u00e8 l'adozione di <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\"><strong>Modulazione di ampiezza a impulsi a 4 livelli (PAM4)<\/strong><\/a> segnalazione. Le precedenti velocit\u00e0 Ethernet, compresa quella a 100G, si basavano prevalentemente sulla codifica Non-Return-to-Zero (NRZ), che trasmette 1 bit per simbolo utilizzando due livelli di segnale distinti (alto\/basso).<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>NRZ:<\/strong> 2 livelli, 1 bit per simbolo.<\/p><\/li>\n\n\n\n<li><p><strong>PAM4:<\/strong> 4 livelli di segnale distinti, che trasmettono 2 bit per simbolo (00, 01, 10, 11).<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Raddoppiando la quantit\u00e0 di informazioni trasportate per simbolo, il PAM4 raddoppia di fatto la velocit\u00e0 di trasmissione in bit per una data velocit\u00e0 in baud (velocit\u00e0 di simbolo). Ad esempio, una corsia che opera a 26,56 Gbaud con NRZ fornisce circa 25 Gb\/s, ma con il PAM4 fornisce <strong>50 Gb\/s<\/strong>. Questa efficienza \u00e8 fondamentale per realizzare <strong>Ethernet 200G\/400G<\/strong> senza richiedere un aumento lineare e non scalabile della larghezza di banda elettrica e del consumo energetico.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Correzione degli errori in avanti (FEC) obbligatoria<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Il compromesso per l'efficienza spettrale del PAM4 \u00e8 una riduzione <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/snr-signal-to-noise-ratio-and-its-impact-on-signal-quality\/\">Rapporto segnale-rumore (SNR)<\/a> a causa della minore differenza di tensione tra i quattro livelli di segnale. Per mantenere il basso tasso di errore binario (BER) necessario per un funzionamento affidabile del data center, <strong>IEEE 802.3bs<\/strong> realizzato <strong>Correzione anticipata degli errori Reed-Solomon (RS-FEC)<\/strong> obbligatorio.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Funzione:<\/strong> Il sistema RS-FEC aggiunge dati ridondanti al segnale trasmesso, consentendo al ricevitore di rilevare e correggere un certo numero di errori senza necessit\u00e0 di ritrasmissione.<\/p><\/li>\n\n\n\n<li><p><strong>Significato:<\/strong> <a href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/fec-correzione-degli-errori-in-avanti-nelle-comunicazioni-ottiche\/\" target=\"_blank\" rel=\"\">FEC<\/a> \u00e8 un componente fondamentale che compensa il degrado intrinseco del segnale nella trasmissione PAM4 ad alta velocit\u00e0, garantendo l'integrit\u00e0 e la stabilit\u00e0 di <strong>400 GbE<\/strong> link.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u25b6 Specifiche tecniche essenziali del PMD da 200G e 400G<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>IEEE 802.3bs<\/strong> definisce diversi<strong> Dipendente dal mezzo fisico (PMD)<\/strong> specifiche che definiscono il tipo di cavo, la distanza e la tecnologia ottica per i collegamenti sia a 200G che a 400G. Questi standard costituiscono la base per tutti i sistemi conformi <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472016.htm\"><strong>QSFP-DD<\/strong><\/a> and <strong>Ricetrasmettitori ottici OSFP<\/strong>.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/67699e3f6c4c462fa786513cbfd604ce.webp\" alt=\"Transceiver ottici da 200G\/400G\" class=\"wp-image-3608\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/67699e3f6c4c462fa786513cbfd604ce.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/67699e3f6c4c462fa786513cbfd604ce-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/67699e3f6c4c462fa786513cbfd604ce-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/67699e3f6c4c462fa786513cbfd604ce-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/67699e3f6c4c462fa786513cbfd604ce-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup\/><tbody><tr\/><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 179px;\"\/><col style=\"width: 78px;\"\/><col style=\"width: 82px;\"\/><col style=\"width: 154px;\"\/><col style=\"width: 84px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"179\"><p><strong>Standard<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"78\"><p><strong>Tasso<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"82\"><p><strong>Tipo di fibra<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"154\"><p><strong>Corsie \/ Lunghezze d\u2019onda<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"84\"><p><strong>Portata (min.)<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Tecnologia<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"179\"><p><strong>400GBASE-SR16<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"78\"><p>400G<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"82\"><p>MMF (OM4)<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"154\"><p>16 fibre (8 Tx, 8 Rx)<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"84\"><p>100 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibra parallela<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"179\"><p><strong>400GBASE-DR4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"78\"><p>400G<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"82\"><p>SMF<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"154\"><p>4 fibre (4 Tx, 4 Rx)<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"84\"><p>500 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibra parallela (4\u00d7100G)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"179\"><p><strong>400GBASE-FR8<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"78\"><p>400G<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"82\"><p>SMF<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"154\"><p>8 lunghezze d'onda<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"84\"><p>2 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>CWDM \/ LWDM<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"179\"><p><strong>400GBASE-LR8<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"78\"><p>400G<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"82\"><p>SMF<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"154\"><p>8 lunghezze d'onda<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"84\"><p>10 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>CWDM \/ LWDM<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"179\"><p><strong>200GBASE-DR4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"78\"><p>200G<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"82\"><p>SMF<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"154\"><p>4 fibre (4 Tx, 4 Rx)<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"84\"><p>500 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibra parallela (4\u00d750G)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"179\"><p><strong>200GBASE-FR4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"78\"><p>200G<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"82\"><p>SMF<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"154\"><p>4 lunghezze d'onda<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"84\"><p>2 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>CWDM \/ LWDM<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u25b6 Il ruolo fondamentale degli standard 400GBASE-DR4 e 400GBASE-LR8<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Nei moderni data center hyperscale, il <strong>400GBASE-DR4<\/strong> and <strong>400GBASE-LR8<\/strong> specifiche, entrambe definite da <strong>IEEE 802.3bs<\/strong>, sono fondamentali.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>400GBASE-DR4:<\/strong> Utilizza quattro coppie parallele di fibre monomodali (SMF), ciascuna delle quali trasmette a una velocit\u00e0 di 100 Gb\/s utilizzando <a href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\" target=\"_blank\" rel=\"\">trasmettitore PAM4<\/a>. Questo approccio ottico parallelo offre una soluzione economicamente vantaggiosa per distanze fino a 500 m ed \u00e8 ampiamente adottato nelle architetture \u201cspine-and-leaf\u201d all\u2019interno dei data center. \u00c8 importante sottolineare che un ricetrasmettitore 400GBASE-DR4 pu\u00f2 spesso essere <em>scappato<\/em> in quattro collegamenti 100GBASE-DR distinti.<\/p><\/li>\n\n\n\n<li><p><strong>400GBASE-LR8:<\/strong> Leva finanziaria <a href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/wdm-optical-transceiver-module-applications\/\" target=\"_blank\" rel=\"\">la multiplazione a divisione di lunghezza d\u2019onda (WDM)<br><\/a> trasmettendo 8 canali (lunghezze d'onda) a 50 Gb\/s in modalit\u00e0 PAM4 su una singola coppia di fibre, raggiungendo una portata di 10 km. Si tratta dello standard di riferimento per il collegamento di data center geograficamente distanti e punti di aggregazione ad alta densit\u00e0.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u25b6 L'impatto sul business: i ricetrasmettitori ottici da 200G\/400G e il futuro delle reti<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La ratifica di <strong>IEEE 802.3bs<\/strong> ha stimolato direttamente lo sviluppo di moduli ottici innestabili di nuova generazione, in particolare il <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472000.htm\"><strong>QSFP-DD (Quad Small Form-factor Pluggable Double Density)<\/strong><\/a> and <strong>OSFP (Octal Small Form-factor Pluggable)<\/strong> formati.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Questi moduli ospitano i complessi sistemi ottici e <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/digital-signal-processor-functionality-in-optical-transceivers\/\">l\u2019elaborazione digitale del segnale (DSP)<\/a> necessario per implementare la segnalazione PAM4 e l'RS-FEC definiti nella norma. Per i leader del settore come <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/\">LINK-PP<\/a>, il rispetto di <strong>IEEE 802.3bs<\/strong> \u00e8 un requisito imprescindibile, che garantisce l'interoperabilit\u00e0, l'affidabilit\u00e0 e prestazioni sicure.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Promuovere l'iper-scalabilit\u00e0 e l'efficienza energetica<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La tecnologia alla base di <strong>3bs<\/strong> affronta direttamente le crescenti sfide operative delle reti su larga scala:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><p><strong>Costo per bit inferiore:<\/strong> Grazie all'utilizzo della segnalazione PAM4 ad alta densit\u00e0, si riduce la necessit\u00e0 di un numero maggiore di componenti paralleli a velocit\u00e0 inferiore, con una conseguente riduzione significativa del costo per bit.<\/p><\/li>\n\n\n\n<li><p><strong>Ottimizzazione dell'alimentazione:<\/strong> L'efficienza intrinseca del PAM4, unita alla progettazione ottimizzata dei ricetrasmettitori, contribuisce a ridurre il consumo energetico per gigabit: un fattore fondamentale per il raffreddamento dei data center di grandi dimensioni.<\/p><\/li>\n\n\n\n<li><p><strong>Protezione futura:<\/strong> <strong>IEEE 802.3bs<\/strong> ha gettato le basi per gli standard futuri (ad esempio, lo standard 802.3ck per trasmissioni elettriche a 100G per corsia), dimostrando la fattibilit\u00e0 della tecnologia PAM4 per interfacce ad altissima velocit\u00e0 e aprendo la strada ai sistemi a 800G e 1,6T.<\/p><\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\">\u25b6 Conclusione: IEEE 802.3bs \u2014 Lo standard che definisce la larghezza di banda moderna<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>IEEE 802.3bs<\/strong> \u00e8 ben pi\u00f9 di un semplice documento tecnico; \u00e8 il modello di riferimento per l'attuale generazione di reti ottiche ad alta velocit\u00e0. L'introduzione del PAM4 e delle specifiche PMD essenziali per la trasmissione a 200G e 400G ha rivoluzionato le interconnessioni utilizzate negli ambienti cloud hyperscale, nei cluster di calcolo per l'intelligenza artificiale e nelle reti di telecomunicazioni core.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Per i tecnici di rete e i responsabili degli acquisti, la scelta di soluzioni conformi <strong>transceiver ottici 200G\/400G<\/strong> \u00e8 l'unica strada per garantire una vera interoperabilit\u00e0 \"plug-and-play\" e una scalabilit\u00e0 a prova di futuro. Affidarsi a prodotti basati su standard consolidati e autorevoli come <strong>IEEE 802.3bs<\/strong> \u00e8 fondamentale per districarsi nella complessit\u00e0 della realizzazione dei data center di nuova generazione.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Sei pronto ad aggiornare la tua dorsale di rete allo standard IEEE 802.3bs?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Scopri la selezione di prodotti affidabili e ad alte prestazioni di LINK-PP <strong>Transceiver ottici da 200G\/400G<\/strong> oggi stesso e assicurati che la tua infrastruttura sia pronta per il futuro dei dati.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udc49 <a target=\"_blank\" rel=\"noopener\" class=\"ng-star-inserted\" href=\"https:\/\/www.l-p.com\/store-26044-200-400-800g-transceiver-modules.htm\"><strong>Scopri i nostri moduli ricetrasmettitori ottici da 200G\/400G<\/strong><\/a><\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup\/><tbody><tr\/><\/tbody>\n<\/table>\n<\/figure>","protected":false},"excerpt":{"rendered":"<p>Approfondisci lo standard IEEE 802.3bs, la base per l\u2019Ethernet moderna a 200G e 400G. Scopri le specifiche, la modulazione PAM4 e come questa tecnologia sta guidando i data center iperscalari con i transceiver ottici. <\/p>","protected":false},"author":1,"featured_media":3609,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[17,24,26],"class_list":["post-3610","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-400g-optical-modules","tag-link-pp","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/3610","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/comments?post=3610"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/3610\/revisions"}],"predecessor-version":[{"id":10831,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/3610\/revisions\/10831"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media\/3609"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media?parent=3610"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/categories?post=3610"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/tags?post=3610"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}