{"id":3578,"date":"2025-11-28T00:00:00","date_gmt":"2025-11-28T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/glossary\/what-is-physical-medium-dependent-pmd\/"},"modified":"2026-06-22T04:35:06","modified_gmt":"2026-06-22T04:35:06","slug":"what-is-physical-medium-dependent-pmd","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-physical-medium-dependent-pmd","title":{"rendered":"PMD (Physical Medium Dependent): Guida Pratica per i Link Ottici"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe.webp\" alt=\"PMD (Physical Medium Dependent)\" class=\"wp-image-3574\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>Dipendente dal mezzo fisico (PMD)<\/strong> Il sottolivello \u00e8 uno degli elementi pi\u00f9 importanti del livello fisico Ethernet, eppure \u00e8 spesso frainteso. Il PMD definisce come i bit vengono fisicamente trasmessi e ricevuti su un determinato mezzo: fibra monomodale, fibra multimodale, rame con connessione diretta o backplane elettrico.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Per progettisti di rete, ingegneri di test e team di approvvigionamento, comprendere il PMD \u00e8 essenziale perch\u00e9 le specifiche PMD influenzano direttamente <strong>l\u2019interoperabilit\u00e0<\/strong>, <strong>alla portata<\/strong>, <strong>integrit\u00e0 del segnale<\/strong>, and <strong>la scelta dei transceiver<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Questa guida fornisce una spiegazione professionale e conforme agli standard del PMD, inclusi i parametri da valutare nella selezione di <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">trasceivers ottici<\/a> moduli quali SFP, SFP+ e QSFP.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Che cos\u2019\u00e8 il sottolivello Physical Medium Dependent (PMD)?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>Dipendente dal mezzo fisico (PMD)<\/strong> Il sottolivello \u00e8 il blocco funzionale pi\u00f9 basso del <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/ieee-802-3-ethernet-standard-explained\/\">IEEE 802.3<\/a> PHY. Definisce le <strong>caratteristiche ottiche o elettriche<\/strong> necessarie per una trasmissione corretta sul mezzo scelto.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nei prodotti reali, il PMD corrisponde all\u2019interfaccia front-end di un transceiver ottico: il suo laser, il fotodiodo ricevitore, la circuitazione di modulazione e i componenti correlati.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Cosa controlla il PMD<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>La lunghezza d\u2019onda ottica e la larghezza spettrale<\/p><\/li><li><p>La potenza media in trasmissione (Tx) e le condizioni di emissione<\/p><\/li><li><p>La sensibilit\u00e0 del ricevitore (Rx) e i limiti di sovraccarico<\/p><\/li><li><p>Ottico <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/optical-transceiver-return-loss-back-reflection-guide\/\">La perdita di ritorno<\/a> e il rapporto di estinzione<\/p><\/li><li><p>Il tipo di fibra supportato e la distanza del collegamento<\/p><\/li><li><p>Le maschere dell\u2019occhio di trasmissione\/ricerca elettrica (per PHY elettrici)<\/p><\/li><li><p>Le definizioni dei punti di misura per le verifiche di conformit\u00e0<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Il PMD funge da <strong>ponte tra la logica PHY standardizzata e il mondo fisico<\/strong>, garantendo che i transceiver di diversi fornitori possano interoperare sullo stesso impianto in fibra.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f PMD rispetto ad altri sottolivelli PHY<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019architettura PHY Ethernet include tipicamente:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/pcs-physical-coding-sublayer-ethernet-explained\/\"><strong>PCS (sottolivello di codifica fisica)<\/strong> <\/a>\u2014 codifica, 64b\/66b, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/fec-forward-error-correction-in-optical-communication\/\">FEC<\/a>, e distribuzione dei canali<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/pma-physical-medium-attachment-ethernet-explained\/\"><strong>PMA (attacco al mezzo fisico)<\/strong><\/a> \u2014 serializzazione\/deserializzazione, recupero del clock<\/p><\/li><li><p><strong>PMD (dipendenza dal mezzo fisico)<\/strong> \u2014 parametri ottici\/elettrici specifici del mezzo<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Il PMD \u00e8 la porzione direttamente legata al budget ottico e al tipo di mezzo.<br\/>Un singolo MAC pu\u00f2 supportare pi\u00f9 PMD (ad esempio SR, LR, ER), ciascuno ottimizzato per una portata o un mezzo diverso.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Perch\u00e9 il PMD \u00e8 importante nelle reti reali<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34.webp\" alt=\"Why PMD Matters in Real Networks\" class=\"wp-image-3575\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Interoperabilit\u00e0 garantita<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Solo i moduli conformi alle stesse specifiche PMD si collegano in modo affidabile. Lunghezza d'onda, livelli di potenza e sensibilit\u00e0 devono essere conformi ai requisiti IEEE.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Portata del collegamento prevedibile<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">I parametri PMD definiscono il budget di perdita del collegamento. Se un modulo specifica una potenza di trasmissione (Tx) compresa tra \u20133 dBm e +3 dBm e una sensibilit\u00e0 di ricezione (Rx) di \u201314 dBm, il budget ottico utilizzabile \u00e8 calcolato a partire da questi valori.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Test accurati e conformit\u00e0<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PMD definisce punti di test standardizzati (ad es. TP2, TP3), garantendo che potenza ottica, jitter e diagrammi dell\u2019occhio siano misurati in modo coerente.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Affidabilit\u00e0 nel tempo<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">I moduli con margini PMD pi\u00f9 ampi tollerano meglio l\u2019invecchiamento, le variazioni di temperatura, la contaminazione della fibra e le riflessioni sui connettori rispetto ai moduli realizzati secondo i requisiti minimi.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Parametri PMD chiave da valutare<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ogni specifica PMD include diversi parametri ottici ed elettrici critici. La loro comprensione garantisce una corretta selezione del modulo.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Lunghezza d\u2019onda (\u03bb) e larghezza spettrale<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Valori comuni includono:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/850nm-optical-transceivers-for-short-reach-mmf-transmission\/\"><strong>850nm<\/strong><\/a> \u2014 corto raggio multimodale (SR)<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/1310nm-optical-module-applications-performance-comparison\/\"><strong>1310 nm<\/strong><\/a> \u2014 singolo modo a raggio medio (LR)<\/p><\/li><li><p>Range specifici per le varianti LX, BX, CWDM e DWDM<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">La larghezza spettrale influisce sulle prestazioni relative alla dispersione, specialmente per collegamenti a lunga distanza.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Potenza media del trasmettitore (Tx)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Specifica la potenza di uscita minima e massima.<br\/>Troppo bassa \u2192 il collegamento potrebbe non raggiungere il ricevitore.<br\/>Troppo alta \u2192 potrebbe sovraccaricare i ricevitori o causare effetti non lineari.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Sensibilit\u00e0 e sovraccarico del ricevitore<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Sensibilit\u00e0:<\/strong> livello di potenza pi\u00f9 basso al quale il ricevitore soddisfa i requisiti di BER<\/p><\/li><li><p><strong>Sovraccarico:<\/strong> potenza di ingresso massima prima che si verifichi distorsione del segnale<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Questi due valori definiscono il budget ottico utilizzabile <strong>budget di potenza ottica<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Rapporto di estinzione e perdita di ritorno<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/extinction-ratio-importance-signal-quality-data-reliability\/\"><strong>Rapporto di estinzione<\/strong><\/a> garantisce una distinzione chiara tra i livelli logici \u201c1\u201d e \u201c0\u201d.\u201d<\/p><\/li><li><p><strong>Perdita ottica di ritorno<\/strong> determina la tolleranza alle riflessioni \u2014 fondamentale su tratti lunghi in fibra monomodale.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Tipo di fibra supportata e portata<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le tabelle PMD specificano:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>portata per fibra multimodale OM2\/OM3\/OM4<\/p><\/li><li><p>portata per fibra monomodale G.652\/G.655<\/p><\/li><li><p>lunghezza massima supportata secondo i budget di potenza IEEE<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f PMD nella selezione dei transceiver ottici<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Quando si scelgono moduli ottici per <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/what-is-a-data-center\/\">data center<\/a>, reti industriali o infrastrutture di telecomunicazione, la conferma della conformit\u00e0 PMD garantisce:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Interoperabilit\u00e0 IEEE reale<\/p><\/li><li><p>Portata corretta sulla fibra esistente<\/p><\/li><li><p>Margini di perdita prevedibili<\/p><\/li><li><p>Prestazioni robuste in ambienti con temperature estreme o rumorosi<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ad esempio, la scelta tra <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475415.htm\"><strong>10GBASE-SR<\/strong><\/a>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475586.htm\"><strong>10GBASE-LR<\/strong><\/a>, and <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476054.htm\"><strong>10GBASE-ER<\/strong><\/a> equivale essenzialmente a selezionare diversi PMD ottimizzati per 300 m, 10 km o 40 km.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b.webp\" alt=\"10GBASE-SR, 10GBASE-LR, and 10GBASE-E\" class=\"wp-image-3576\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Tabella riepilogativa di esempio PMD <\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Sostituire i valori con i parametri esatti tratti dal foglio dati del modulo <\/em><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/file\/datasheet\/ls-sm3110-10c.pdf\"><em>SFP+ scelto<\/em><\/a><em>.<\/em><\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 220px;\"\/><col style=\"width: 214px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Attributo PMD<\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>Valore tipico<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Descrizione<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Lunghezza d\u2019onda<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>1310 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Laser monomodale a lunga portata<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Potenza di trasmissione (min\/max)<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>\u20133 dBm \/ +3 dBm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Intervallo di potenza di emissione<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Sensibilit\u00e0 del ricevitore<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>\u201314 dBm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Potenza minima per la conformit\u00e0 al BER<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Soglia di sovraccarico del ricevitore<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>+1 dBm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Input massimo sicuro<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Reach<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>10 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Dipende dalle perdite della fibra e dai giunti<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Rapporto di estinzione<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>\u2265 3,5 dB<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Qualit\u00e0 di modulazione del laser<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Verifica e conformit\u00e0 PMD<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Una verifica PMD ben definita garantisce un\u2019interoperabilit\u00e0 affidabile.<br\/>Le misurazioni principali includono:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Potenza ottica presso il trasmettitore e il ricevitore<\/p><\/li><li><p>Conformit\u00e0 alla maschera dell\u2019occhio<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/jitter-in-optics-causes-effects-measurement-reduction\/\">Jitter<\/a> e margine di rumore<\/p><\/li><li><p>Verifica a punti di temperatura definiti<\/p><\/li><li><p>Conferma della sensibilit\u00e0 del ricevitore in condizioni stressate<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Queste misurazioni sono allineate alle procedure di conformit\u00e0 IEEE.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Risoluzione dei problemi legati a malfunzionamenti PMD<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Potenza ricevuta bassa<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Controllare la pulizia dei connettori, le perdite di fibra inaspettate o un\u2019eccessiva presenza di patch.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Instabilit\u00e0 del collegamento su tratti lunghi<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Verificare l\u2019invecchiamento della potenza di trasmissione (Tx) o una sensibilit\u00e0 marginale: il budget ottico potrebbe essere troppo ristretto.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Le fibre multimodali raggiungono distanze inferiori a quelle previste<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Verificare la compatibilit\u00e0 OM3\/OM4; le limitazioni di larghezza di banda dipendono dal mezzo.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Conclusione<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>Dipendente dal mezzo fisico (PMD)<\/strong> Il sottolivello \u00e8 uno dei concetti fondamentali alla base dell\u2019interoperabilit\u00e0 del livello fisico Ethernet. Specificando lunghezza d\u2019onda ottica, intervalli di potenza, sensibilit\u00e0, portata e punti di prova, il PMD garantisce che i transceiver di diversi produttori operino in modo prevedibile sulla stessa infrastruttura in fibra.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Per le organizzazioni che implementano o aggiornano reti, comprendere il PMD \u00e8 fondamentale per selezionare i moduli ottici appropriati e progettare un collegamento affidabile, conforme agli standard e pronto per il futuro.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>i transceiver ottici LINK-PP<\/strong><\/a> includono specifiche PMD chiaramente definite, rendendoli scelte eccellenti per progetti di rete robusti e allineati agli standard.<\/p>","protected":false},"excerpt":{"rendered":"<p>Il Physical Medium Dependent (PMD) definisce le regole ottiche e elettroniche di un PHY \u2013 lunghezza d'onda, potenza, distanza e punti di prova. Comprendi le specifiche PMD e come guidano la selezione dei trasmettitori.<\/p>","protected":false},"author":1,"featured_media":3577,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[27],"tags":[24,26],"class_list":["post-3578","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-glossary","tag-link-pp","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/3578","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/comments?post=3578"}],"version-history":[{"count":5,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/3578\/revisions"}],"predecessor-version":[{"id":10826,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/3578\/revisions\/10826"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media\/3577"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media?parent=3578"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/categories?post=3578"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/tags?post=3578"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}