{"id":3568,"date":"2025-11-28T00:00:00","date_gmt":"2025-11-28T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/pcs-pma-pmd-work-together\/"},"modified":"2026-06-22T04:34:01","modified_gmt":"2026-06-22T04:34:01","slug":"pcs-pma-pmd-work-together","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/pcs-pma-pmd-work-together","title":{"rendered":"Come funzionano insieme i livelli PCS, PMA e PMD della PHY Ethernet"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d23fa6e6358741de8a06b78eb2e16176.webp\" alt=\"How PCS, PMA, and PMD Work Together\" class=\"wp-image-3564\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d23fa6e6358741de8a06b78eb2e16176.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d23fa6e6358741de8a06b78eb2e16176-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d23fa6e6358741de8a06b78eb2e16176-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d23fa6e6358741de8a06b78eb2e16176-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d23fa6e6358741de8a06b78eb2e16176-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019odierna Ethernet ad alta velocit\u00e0\u201410G, 25G, 40G, 100G e oltre\u2014si basa su un\u2019architettura a strati che garantisce il trasferimento affidabile dei dati dal livello MAC al mezzo fisico di trasmissione. Tra questi strati, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/pcs-physical-coding-sublayer-ethernet-explained\/\"><strong>PCS (sottolivello di codifica fisica)<\/strong><\/a>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/pma-physical-medium-attachment-ethernet-explained\/\"><strong>PMA (attacco al mezzo fisico)<\/strong><\/a>, and <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-physical-medium-dependent-pmd\/\"><strong>PMD (dipendenza dal mezzo fisico)<\/strong><\/a> costituiscono il nucleo dello stack del livello fisico (PHY).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pur essendo strettamente correlati, ciascuno strato svolge una funzione distinta. Comprendere come operano congiuntamente \u00e8 essenziale per gli ingegneri di rete, i progettisti di moduli ottici e chiunque valuti transceiver Ethernet o hardware di connettivit\u00e0.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Funzioni di ciascuno strato<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" ><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/pcs-physical-coding-sublayer-ethernet-explained\/\">PCS \u2014 Sottolivello di codifica fisica<\/a><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Il PCS gestisce <strong>la codifica dei dati, l\u2019allineamento dei blocchi, la distribuzione sui lane e il rilevamento degli errori<\/strong>.<br\/>Principali responsabilit\u00e0:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>schemi di codifica (8b\/10b, 64b\/66b, 256b\/257b)<\/p><\/li><li><p>striping e deskew dei lane (per Ethernet multi-lane)<\/p><\/li><li><p>allineamento delle parole e delimitazione dei frame<\/p><\/li><li><p>monitoraggio degli errori (BER, errore di blocco)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Il PCS converte i dati del livello MAC in un flusso di bit codificato<\/strong> adatto alla serializzazione ad alta velocit\u00e0.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" ><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/pma-physical-medium-attachment-ethernet-explained\/\">PMA \u2014 Attacco al mezzo fisico<\/a><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Il PMA \u00e8 responsabile della <strong>serializzazione\/deserializzazione<\/strong>, <strong>Recupero dell\u2019orologio<\/strong>, and <strong>adattamento elettrico<\/strong> tra PCS e PMD.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le sue principali funzioni:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/serdes-interfaces-high-speed-data-transfer-and-signal-integrity\/\"><strong>SerDes<br><\/strong><\/a> (conversione parallelo-seriale e seriale-parallelo)<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/clock-and-data-recovery-in-modern-communication-systems\/\"><strong>CDR<\/strong><\/a> (recupero di clock e dati)<\/p><\/li><li><p>Generazione di flussi di bit ad alta velocit\u00e0 stabili per la trasmissione<\/p><\/li><li><p>Combinazione di pi\u00f9 lane (es. 4\u00d725G \u2192 100G)<\/p><\/li><li><p>Gestione dell\u2019interfaccia elettrica PHY all\u2019interno di un transceiver<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Il PMA garantisce che il segnale sia pulito, sincronizzato e pronto per la trasmissione sul mezzo.<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" ><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-physical-medium-dependent-pmd\/\">PMD \u2014 Dipendenza dal mezzo fisico<\/a><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Il PMD \u00e8 lo strato che interagisce direttamente con il <strong>mezzo fisico di trasmissione effettivo<\/strong>, come fibra ottica, rame, DAC o AOC.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Il PMD include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>trasmettitori\/ricevitori ottici (es. laser, fotodiodi)<\/p><\/li><li><p>driver e amplificatori elettrici<\/p><\/li><li><p>selezione della lunghezza d\u2019onda<\/p><\/li><li><p>controllo della potenza di emissione e della sensibilit\u00e0<\/p><\/li><li><p>parametri specifici del mezzo (fibra OM3\/OM4, coppie di rame da 100 ohm, ecc.)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Il PMD converte il segnale elettrico proveniente dal PMA in segnali ottici o in rame che viaggiano sul collegamento fisico.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Come PCS, PMA e PMD operano congiuntamente<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8f686013e096433f9a02240754eb8dec.webp\" alt=\"PCS, PMA, and PMD Work Together\" class=\"wp-image-3565\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8f686013e096433f9a02240754eb8dec.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8f686013e096433f9a02240754eb8dec-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8f686013e096433f9a02240754eb8dec-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8f686013e096433f9a02240754eb8dec-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8f686013e096433f9a02240754eb8dec-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Il flusso dei dati attraverso lo stack PHY segue questa pipeline:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Passo 1: Il PCS codifica e organizza i dati<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">I dati provenienti dal MAC sono:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Codificati (64b\/66b o altri)<\/p><\/li><li><p>Distribuiti nei lane (se multi-lane)<\/p><\/li><li><p>Allineati e bloccati a livello di blocco<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Questo prepara i dati per la serializzazione ad alta velocit\u00e0, mantenendo l\u2019integrit\u00e0 del segnale.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Passo 2: Il PMA converte e sincronizza il flusso di bit<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PMA:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Serializza i dati codificati dal PCS in un flusso continuo di bit<\/p><\/li><li><p>Recupera il timing del clock dai dati in ingresso<\/p><\/li><li><p>Applica <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/serdes-interfaces-high-speed-data-transfer-and-signal-integrity\/\">SerDes<br><\/a> equalizzazione e ritiming<\/p><\/li><li><p>Garantisce il bonding dei lane per protocolli multi-lane (XLAUI, CAUI-4, ecc.)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Questo stabilizza il segnale prima della trasmissione.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Passo 3: Il PMD invia il segnale attraverso il mezzo<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Il livello PMD:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Converte i segnali elettrici in segnali ottici (mediante laser\/fotodiodo)<\/p><\/li><li><p>Oppure adatta le uscite elettriche per rame (BASE-T, DAC)<\/p><\/li><li><p>Controlla i formati di modulazione (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/understanding-non-return-to-zero-in-digital-communication\/\">NRZ<\/a>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\">trasmettitore PAM4<\/a>)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Sul lato ricezione, il PMD inverte il processo e restituisce segnali elettrici puliti al PMA.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Perch\u00e9 questi livelli sono importanti<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Per le prestazioni del transceiver ottico<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Questi livelli determinano:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>La velocit\u00e0 massima dei dati<\/p><\/li><li><p>La capacit\u00e0 di distanza del collegamento<\/p><\/li><li><p>Le prestazioni in termini di errore (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/understanding-what-is-bit-error-rate\/\">BER<\/a>)<\/p><\/li><li><p>Latenza<\/p><\/li><li><p>Efficienza energetica<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Il PMA e il PMD sono particolarmente critici nei <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/488452.htm\"><strong>100G<\/strong><\/a><strong>\/<\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473139.htm\"><strong>200G<\/strong><\/a><strong>\/<\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472016.htm\"><strong>400G<\/strong><\/a><strong> transceiver PAM4<\/strong>, dove il recupero del clock e la modulazione ottica richiedono un DSP avanzato.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Per gli integratori di sistema<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Una chiara comprensione delle interazioni tra PCS-PMA-PMD aiuta a:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Selezionare componenti compatibili <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26155-1g-sfp.htm\">SFP<\/a>\/<a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491483.htm\">moduli QSFP<\/a><\/p><\/li><li><p>Risolvere problemi relativi al collegamento ottico<\/p><\/li><li><p>Assicurare una corretta mappatura dei lane (ad es. breakout)<\/p><\/li><li><p>Diagnosticare errori di codifica o di allineamento<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >Come l\u2019hardware LINK-PP supporta la stabilit\u00e0 di PCS\/PMA\/PMD<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">LINK-PP fornisce componenti magnetici Ethernet, accessori per transceiver ottici e componenti di connettivit\u00e0 ad alte prestazioni progettati per:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Bassa perdita d\u2019inserzione e alta integrit\u00e0 del segnale (supporta le prestazioni SerDes del PMA)<\/p><\/li><li><p>Suppressione delle interferenze elettromagnetiche (EMI) per operazioni stabili di PCS\/PMA<\/p><\/li><li><p>Caratteristiche elettriche robuste per collegamenti a lunga distanza<\/p><\/li><li><p>Compatibilit\u00e0 con i principali OEM di networking<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Connettori di alta qualit\u00e0, magnetics RJ45 e componenti ottici contribuiscono a mantenere <strong>la chiarezza del segnale su tutti i sottolivelli PHY<\/strong>, garantendo un funzionamento affidabile dalla codifica PCS alla trasmissione PMD.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9240db12025d485c8973a6532e9fb4d7.jpg\" alt=\"LINK-PP Solutions\" class=\"wp-image-3566\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9240db12025d485c8973a6532e9fb4d7.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9240db12025d485c8973a6532e9fb4d7-300x178.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9240db12025d485c8973a6532e9fb4d7-1024x608.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9240db12025d485c8973a6532e9fb4d7-768x456.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9240db12025d485c8973a6532e9fb4d7-18x12.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >Conclusione<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>PCS, PMA e PMD lavorano insieme come tre livelli sincronizzati del PHY Ethernet<\/strong>, formando la pipeline essenziale che consente ai dati ad alta velocit\u00e0 di viaggiare in modo pulito e affidabile attraverso reti in fibra ottica e rame.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/pcs-physical-coding-sublayer-ethernet-explained\/\">PCS<\/a> gestisce <strong>codifica e allineamento<\/strong><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/pma-physical-medium-attachment-ethernet-explained\/\">PMA<\/a> gestisce <strong>serializzazione e temporizzazione<\/strong><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-physical-medium-dependent-pmd\/\">PMD<\/a> gestisce <strong>trasmissione specifica del mezzo<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Comprendere i loro ruoli \u00e8 fondamentale nella valutazione di moduli ottici ad alta velocit\u00e0, progetti di rete o prestazioni del livello fisico.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >FAQ<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Qual \u00e8 la differenza tra PCS, PMA e PMD nell\u2019Ethernet?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PCS (Physical Coding Sublayer) gestisce la codifica dei dati, l\u2019allineamento dei blocchi, la distribuzione dei lane e il rilevamento degli errori.<br\/>PMA (Physical Medium Attachment) esegue la serializzazione\/deserializzazione (SerDes) e il recupero del clock.<br\/>PMD (Physical Medium Dependent) interagisce con il mezzo fisico effettivo \u2014 inviando e ricevendo segnali elettrici o ottici.<\/p>\n\n\n\n<hr class=\"wp-block-separator\" \/>\n\n\n\n<h3 class=\"wp-block-heading\" >Perch\u00e9 PCS, PMA e PMD devono lavorare insieme?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Questi tre strati formano l\u2019intera pipeline PHY Ethernet. Il PCS prepara i dati, il PMA li converte in flussi di bit serializzati e il PMD li trasmette su rame o fibra. Solo lavorando insieme il PHY pu\u00f2 mantenere la sincronizzazione temporale, l\u2019integrit\u00e0 del segnale e l\u2019interoperabilit\u00e0 su collegamenti ad alta velocit\u00e0.<\/p>\n\n\n\n<hr class=\"wp-block-separator\" \/>\n\n\n\n<h3 class=\"wp-block-heading\" >Ogni velocit\u00e0 Ethernet utilizza PCS, PMA e PMD?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00ec. Indipendentemente dalla velocit\u00e0 \u2014 1G, 10G, 25G, 100G o 400G \u2014 questi blocchi sono presenti nell\u2019architettura PHY Ethernet. Le loro implementazioni interne possono variare (ad esempio, schemi di codifica diversi o corsie SerDes diverse), ma la struttura funzionale rimane costante.<\/p>\n\n\n\n<hr class=\"wp-block-separator\" \/>\n\n\n\n<h3 class=\"wp-block-heading\" >In che modo il PCS influisce sulla stabilit\u00e0 e sulle prestazioni del collegamento?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Il PCS migliora la robustezza del collegamento mediante:<br\/>\u2022 la codifica a blocchi (ad esempio, 64b\/66b, 256b\/257b)<br\/>\u2022 l\u2019aggiunta di intestazioni di sincronizzazione<br\/>\u2022 l\u2019abilitazione della distribuzione su corsie e della correzione dello skew<br\/>\u2022 la fornitura del rilevamento degli errori (ad esempio, CRC\/FEC)<br\/>Queste funzioni riducono il tasso di errore sui bit e supportano una trasmissione affidabile su lunghe distanze e ad alta velocit\u00e0.<\/p>\n\n\n\n<hr class=\"wp-block-separator\" \/>\n\n\n\n<h3 class=\"wp-block-heading\" >Qual \u00e8 il ruolo del PMA nei transceiver ottici?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">In <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">Moduli SFP, SFP+, SFP28, QSFP+ e QSFP28<\/a>, il livello PMA include i circuiti SerDes e di recupero del clock che abbinano le corsie elettriche lato host ai driver ottici. Garantisce l\u2019accuratezza temporale, l\u2019allineamento delle corsie dati e la conversione senza soluzione di continuit\u00e0 tra dominio elettrico e dominio ottico.<\/p>\n\n\n\n<hr class=\"wp-block-separator\" \/>\n\n\n\n<h3 class=\"wp-block-heading\" >Il PMD \u00e8 utilizzato solo per la fibra ottica?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No. Il PMD si applica sia alla fibra sia al rame.<br\/>\u2022 Nei transceiver ottici, il PMD include laser, fotodiodi e circuiti di modulazione.<br\/>\u2022 Nelle interfacce in rame (ad esempio, BASE-T), il PMD include front-end analogici, trasformatori e <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-17492-integrated-rj45-connector.htm\">connessioni RJ45<\/a>.<br\/>Il suo compito \u00e8 sempre accoppiare i segnali PHY con il mezzo fisico.<\/p>\n\n\n\n<hr class=\"wp-block-separator\" \/>\n\n\n\n<h3 class=\"wp-block-heading\" >In che modo questi strati influenzano la compatibilit\u00e0 dei moduli?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Per garantire l\u2019interoperabilit\u00e0, la codifica PCS, il comportamento SerDes del PMA e le specifiche ottiche\/elettriche del PMD devono conformarsi a <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/ieee-802-3-ethernet-standard-explained\/\">Standard IEEE 802.3<\/a>. Ci\u00f2 assicura che i transceiver \u2014 anche di marche diverse \u2014 funzionino senza problemi con switch, router e schede di rete (NIC), purch\u00e9 condividano lo stesso standard.<\/p>","protected":false},"excerpt":{"rendered":"<p>Scopri come PCS, PMA e PMD operano congiuntamente all'interno della PHY Ethernet, abilitando una trasmissione dati ad alta velocit\u00e0 affidabile su reti in fibra ottica e in rame.<\/p>","protected":false},"author":1,"featured_media":3567,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[22,24,26],"class_list":["post-3568","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-integrated-rj45-connectors","tag-link-pp","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/3568","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/comments?post=3568"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/3568\/revisions"}],"predecessor-version":[{"id":10824,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/3568\/revisions\/10824"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media\/3567"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media?parent=3568"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/categories?post=3568"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/tags?post=3568"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}