{"id":3539,"date":"2025-12-01T00:00:00","date_gmt":"2025-12-01T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/glossary\/fmmu-ethercat-fieldbus-memory-management-unit-guide\/"},"modified":"2026-06-22T04:30:14","modified_gmt":"2026-06-22T04:30:14","slug":"fmmu-ethercat-fieldbus-memory-management-unit-guide","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/fmmu-ethercat-fieldbus-memory-management-unit-guide","title":{"rendered":"FMMU Spiegato: L'Unit\u00e0 Centrale del Gestione della Memoria nel EtherCAT"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b3640423b8524db9adc3f9275a6cfda1.webp\" alt=\"What Is FMMU (Fieldbus Memory Management Unit) in EtherCAT? A Complete Technical Guide\" class=\"wp-image-3534\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b3640423b8524db9adc3f9275a6cfda1.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b3640423b8524db9adc3f9275a6cfda1-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b3640423b8524db9adc3f9275a6cfda1-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b3640423b8524db9adc3f9275a6cfda1-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b3640423b8524db9adc3f9275a6cfda1-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Nell\u2019automazione industriale moderna, lo scambio di dati in tempo reale \u00e8 essenziale per ottenere un controllo rapido, sincronizzato e altamente affidabile. <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/ethercat-definitive-guide-realtime-industrial-ethernet\/\">EtherCAT<\/a>\u2014una delle principali tecnologie Industrial Ethernet\u2014raggiunge le sue eccezionali prestazioni grazie a diverse innovazioni architettoniche. Tra queste, il <strong>FMMU (Unit\u00e0 di gestione della memoria per fieldbus)<\/strong> svolge un ruolo centrale.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Questo articolo fornisce una spiegazione chiara e tecnicamente accurata di cos\u2019\u00e8 l\u2019FMMU, del perch\u00e9 \u00e8 importante e di come consente ad EtherCAT di garantire comunicazioni in tempo reale a livello di microsecondi. Presentiamo inoltre come <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">i moduli trasceivers in fibra ottica SFP di LINK-PP <\/a>supportano senza soluzione di continuit\u00e0 reti EtherCAT ad alta velocit\u00e0.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Cos\u2019\u00e8 l\u2019FMMU in EtherCAT?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>FMMU (Unit\u00e0 di gestione della memoria per fieldbus)<\/strong> \u00e8 un meccanismo hardware integrato in ogni dispositivo slave EtherCAT che mappa <strong>gli indirizzi logici dei dati di processo provenienti dal master EtherCAT<\/strong> agli <strong>indirizzi fisici della memoria dei singoli nodi slave<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In termini semplici:<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>L\u2019FMMU consente al master EtherCAT di accedere ai dati distribuiti su pi\u00f9 dispositivi slave come se fossero un unico blocco continuo di memoria.<\/strong><\/p><\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">Questo meccanismo \u00e8 fondamentale per l\u2019elaborazione dati \u201con-the-fly\u201d ad alta velocit\u00e0 di EtherCAT, abilitando una comunicazione fieldbus deterministica e a bassa latenza.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Perch\u00e9 EtherCAT necessita di un FMMU?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">I tradizionali sistemi fieldbus richiedono spesso che il master comunichi con ciascun nodo separatamente, causando:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Latenza maggiore<\/p><\/li><li><p>Sovraccarico comunicativo aumentato<\/p><\/li><li><p>Frequenze di aggiornamento inferiori<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">EtherCAT risolve questo problema adottando un approccio diverso:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2714 Il frame EtherCAT transita sequenzialmente attraverso tutti gli slave.<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ogni slave legge e scrive solo i dati che gli appartengono.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2714 L\u2019FMMU garantisce che i dati vengano posizionati nella corretta posizione logica.<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Il risultato \u00e8 uno scambio dati ciclico estremamente efficiente.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >I principali vantaggi abilitati dall\u2019FMMU:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Spazio di indirizzamento logico continuo<\/strong> per il master<\/p><\/li><li><p><strong>Mappatura precisa a livello di byte<\/strong><\/p><\/li><li><p><strong>Elaborazione \u201czero-copy\u201d, in tempo reale<\/strong><\/p><\/li><li><p><strong>Tempi di ciclo ultra-bassi (inferiori a 100 \u03bcs)<\/strong><\/p><\/li><li><p><strong>Utilizzo elevato della larghezza di banda (vicino al 100%)<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Questo \u00e8 uno dei motivi principali per cui <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/ethercat-definitive-guide-realtime-industrial-ethernet\/\">EtherCAT<\/a> \u00e8 adatto a:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Controllo del moto<\/p><\/li><li><p>Robotica<\/p><\/li><li><p>Azionamenti servo ad alta velocit\u00e0<\/p><\/li><li><p>Automazione di precisione<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >Come funziona l\u2019FMMU: mappatura tra indirizzi logici e fisici<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La comunicazione EtherCAT utilizza due tipi di indirizzamento della memoria:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Indirizzo logico (vista del Master)<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/808e8441e1fd4bc99473773fa9d4b233.jpg\" alt=\"FMMU Logical Address (Master view)\" class=\"wp-image-3535\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/808e8441e1fd4bc99473773fa9d4b233.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/808e8441e1fd4bc99473773fa9d4b233-300x300.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/808e8441e1fd4bc99473773fa9d4b233-150x150.jpg 150w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/808e8441e1fd4bc99473773fa9d4b233-768x768.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/808e8441e1fd4bc99473773fa9d4b233-12x12.jpg 12w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Uno spazio di indirizzamento virtuale e continuo definito dal Master per i dati di processo.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Indirizzo fisico (vista dello Slave)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Gli indirizzi effettivi dei registri o dei buffer dati all\u2019interno di un dispositivo slave.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>L\u2019FMMU mappa la memoria logica \u2192 memoria fisica<\/strong>, consentendo:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Granularit\u00e0 a livello di bit<\/p><\/li><li><p>Controllo di lettura\/scrittura<\/p><\/li><li><p>Sincronizzazione efficiente con i SyncManager<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Esempio:<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Se il Master crea una regione PDO logica di 60 byte:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Slave<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Memoria fisica<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Indirizzo logico mappato<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Slave A<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>0x1100<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>0x0000 \u2013 0x000F<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Slave B<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>0x2000<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>0x0010 \u2013 0x0023<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Slave C<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>0x3200<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>0x0024 \u2013 0x003B<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Il Master legge\/scrive soltanto <strong>un\u2019unica area continua di 60 byte<\/strong>, ma i dati vengono instradati automaticamente a ciascuno slave tramite l\u2019hardware FMMU.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"459\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5b84055a9e1044699d33658cfa74b356.webp\" alt=\"What Is the FMMU in EtherCAT?\" class=\"wp-image-3536\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5b84055a9e1044699d33658cfa74b356.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5b84055a9e1044699d33658cfa74b356-300x115.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5b84055a9e1044699d33658cfa74b356-1024x392.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5b84055a9e1044699d33658cfa74b356-768x294.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5b84055a9e1044699d33658cfa74b356-18x7.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >FMMU all\u2019interno del controller slave EtherCAT (ESC)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019FMMU \u00e8 implementato nell\u2019 <strong>ESC (Controller di slave EtherCAT)<\/strong>, integrato nei chip slave EtherCAT, ad esempio:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Beckhoff ET1100<\/p><\/li><li><p>ET1200<\/p><\/li><li><p>Core IP ESC di terze parti<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Un ESC tipico include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>FMMU (solitamente 1\u20133 istanze)<\/strong><\/p><\/li><li><p><strong>SyncManager (SM)<\/strong><\/p><\/li><li><p><strong>Macchina a stati AL<\/strong><\/p><\/li><li><p><strong>Gestori mailbox<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">La configurazione dell\u2019FMMU avviene durante l\u2019inizializzazione tramite protocolli mailbox (CoE, FoE, EoE).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >FMMU ed elaborazione in tempo reale (on-the-fly)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Una delle caratteristiche distintive di EtherCAT \u00e8 che gli slave <strong>non copiano n\u00e9 memorizzano l\u2019intero frame Ethernet<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Invece:<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>Il frame Ethernet transita attraverso lo slave.<\/p><\/li><li><p>L\u2019FMMU verifica quali byte appartengono a questo slave.<\/p><\/li><li><p>I dati vengono inseriti o estratti in tempo reale.<\/p><\/li><li><p>Il frame prosegue verso lo slave successivo con un ritardo dell\u2019ordine di nanosecondi.<\/p><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Questa architettura consente tempi di aggiornamento nell\u2019ordine di:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>&lt; 100 \u03bcs per il controllo servo di oltre 100 assi<\/strong><\/p><\/li><li><p><strong>&lt; 10 \u03bcs di ritardo di inoltro per slave<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Nessun\u2019altra architettura fieldbus raggiunge questo livello di determinismo con un cablaggio cos\u00ec semplice.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Applicazioni in cui l\u2019FMMU \u00e8 fondamentale<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019FMMU contribuisce direttamente alle prestazioni di EtherCAT in:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Controller di movimento multi-asse<\/p><\/li><li><p>Robot pick-and-place<\/p><\/li><li><p>Macchine CNC<\/p><\/li><li><p>Impianti per il confezionamento e la stampa<\/p><\/li><li><p>Produzione di semiconduttori<\/p><\/li><li><p>I\/O distribuito in tempo reale<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">L\u00e0 dove il ciclo di controllo \u00e8 estremamente stringente, l\u2019FMMU garantisce coerenza dati stabile e accurata.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >LINK-PP Prodotti industriali in fibra ottica per reti EtherCAT<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/68b2a236f98f4fe3bc2f22d4e290d690.webp\" alt=\"industrial-grade fiber transceivers\" class=\"wp-image-3537\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/68b2a236f98f4fe3bc2f22d4e290d690.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/68b2a236f98f4fe3bc2f22d4e290d690-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/68b2a236f98f4fe3bc2f22d4e290d690-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/68b2a236f98f4fe3bc2f22d4e290d690-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/68b2a236f98f4fe3bc2f22d4e290d690-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">EtherCAT utilizza comunemente livelli fisici Ethernet quali:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>100BASE-TX<\/p><\/li><li><p>100BASE-FX<\/p><\/li><li><p>1000BASE-X<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Per ambienti che richiedono comunicazioni a lunga distanza o resistenti alle interferenze elettromagnetiche (EMI), LINK-PP offre un\u2019ampia gamma di<a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476820.htm\"> <strong>trascevitori industriali in fibra ottica<\/strong><\/a><strong> and <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26155-1g-sfp.htm\"><strong>moduli SFP<\/strong><\/a>:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vantaggi per le applicazioni EtherCAT:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Elevata immunit\u00e0 alle interferenze elettromagnetiche (EMC)<\/p><\/li><li><p>Opzioni di temperatura industriale da -40 \u00b0C a +85 \u00b0C<\/p><\/li><li><p>Basso ritardo e prestazioni ottiche stabili<\/p><\/li><li><p>Compatibilit\u00e0 con PLC, azionamenti servo e switch industriali<\/p><\/li><li><p>Collegamenti a lunga distanza fino a 80 km<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Questi moduli ottici garantiscono una connettivit\u00e0 affidabile a livello fisico per le reti EtherCAT che si basano sul controllo deterministico basato su FMMU.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Riepilogo<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>FMMU (Unit\u00e0 di gestione della memoria per fieldbus)<\/strong> \u00e8 una delle innovazioni fondamentali che rende EtherCAT una delle reti industriali pi\u00f9 veloci e deterministiche. Mappando i dati di processo logici negli indirizzi fisici specifici degli slave e supportando l\u2019elaborazione dei frame in tempo reale, l\u2019FMMU consente:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Tempi di ciclo a livello di microsecondo<\/p><\/li><li><p>Sincronizzazione estremamente precisa<\/p><\/li><li><p>Utilizzo efficiente della larghezza di banda<\/p><\/li><li><p>Controllo distribuito scalabile<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Quando abbinato a robusti moduli ottici industriali, come quelli di LINK-PP <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">Transceiver SFP e in fibra ottica<\/a>, EtherCAT diventa un\u2019infrastruttura potente e affidabile per i sistemi di automazione moderni.<\/p>","protected":false},"excerpt":{"rendered":"<p>Apprendi cosa \u00e8 l'FMMU (Fieldbus Memory Management Unit) e come abilita la comunicazione EtherCAT real-time attraverso la gestione efficiente della memoria e il processamento dati in tempo reale.<\/p>","protected":false},"author":1,"featured_media":3538,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[27],"tags":[26],"class_list":["post-3539","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-glossary","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/3539","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/comments?post=3539"}],"version-history":[{"count":5,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/3539\/revisions"}],"predecessor-version":[{"id":10817,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/3539\/revisions\/10817"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media\/3538"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media?parent=3539"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/categories?post=3539"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/tags?post=3539"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}