{"id":3516,"date":"2025-12-02T00:00:00","date_gmt":"2025-12-02T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/ieee-802-3cd-50g-100g-200g-pam4-ethernet\/"},"modified":"2026-06-22T08:57:41","modified_gmt":"2026-06-22T08:57:41","slug":"ieee-802-3cd-50g-100g-200g-pam4-ethernet","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/ieee-802-3cd-50g-100g-200g-pam4-ethernet","title":{"rendered":"IEEE 802.3cd spiegato: Ethernet 50G, 100G e 200G con PAM4"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540.webp\" alt=\"What Is IEEE 802.3cd?\" class=\"wp-image-3513\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Cos\u2019\u00e8 IEEE 802.3cd?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">IEEE 802.3cd \u00e8 lo standard Ethernet che definisce il livello fisico (PHY) e <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-physical-medium-dependent-pmd\/\">Dipendente dal mezzo fisico (PMD)<\/a> le specifiche per <strong>reti 50 GbE, 100 GbE e 200 GbE<\/strong> che utilizzano <strong>corsie 50G PAM4<\/strong>. Approvato definitivamente nel 2018, lo standard ha introdotto la segnalazione 50G su singola corsia e combinazioni multicrosia (2\u00d750G e 4\u00d750G), consentendo Ethernet ad alta velocit\u00e0 scalabile con maggiore efficienza delle porte e riduzione del costo per bit.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Lo standard svolge un ruolo centrale nei moderni data center, dove i transceiver ottici PAM4\u2014in particolare <strong>SFP56, <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491591.htm\"><strong>QSFP28<\/strong><\/a><strong>, QSFP56 e QSFP-DD<\/strong>\u2014sono ampiamente impiegati nei percorsi di migrazione da 25G a 200G.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Perch\u00e9 IEEE 802.3cd utilizza la modulazione PAM4<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Una caratteristica distintiva di 802.3cd \u00e8 la transizione da NRZ (PAM2) a <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\"><strong>trasmettitore PAM4<\/strong> modulazione<\/a>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Principali vantaggi di PAM4<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Maggiore densit\u00e0 di dati:<\/strong> PAM4 codifica due bit per simbolo, raddoppiando efficacemente il throughput nella stessa larghezza di banda.<\/p><\/li><li><p><strong>Fattibilit\u00e0 della corsia singola a 50G:<\/strong> Consente 50 Gb\/s per corsia a una velocit\u00e0 di simbolo di circa 50 GBd.<\/p><\/li><li><p><strong>Migliore scalabilit\u00e0:<\/strong> Permette l\u2019espansione della larghezza di banda da 50G \u2192 100G \u2192 200G senza dover riprogettare i fattori di forma delle porte.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Con PAM4, Ethernet ha potuto evolversi utilizzando formati di modulo familiari, pur supportando velocit\u00e0 aggregate molto pi\u00f9 elevate.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc PMD e tipi di interfaccia definiti da IEEE 802.3cd<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >PMD per 50 GbE<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>50GBASE-SR<\/strong> \u2013 Fibra multimodale a corto raggio che utilizza una singola corsia 50G PAM4.<\/p><\/li><li><p><strong>50GBASE-FR<\/strong> \u2013 Fibra monomodale, tipicamente fino a 2 km.<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491591.htm\"><strong>50GBASE-LR<\/strong><\/a> \u2013 SMF con portata di 10 km per applicazioni campus e metropolitane.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >PMD per 100 GbE (2\u00d750G)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>100GBASE-FR2<\/strong> \u2013 Due corsie PAM4 su SMF, portata moderata.<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491583.htm\"><strong>100GBASE-LR2<\/strong><\/a> \u2013 Applicazioni SMF a lunga portata su due corsie.<\/p><\/li><li><p><strong>100GBASE-DR\/DR2<\/strong> \u2013 Ottimizzato per collegamenti SMF a corto-medio raggio nei data center.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >PMD per 200 GbE (4\u00d750G)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473139.htm\"><strong>200GBASE-SR4<\/strong><\/a> \u2013 Quattro corsie da 50G su MMF parallela; ideale per connettivit\u00e0 leaf\/spine ad alta densit\u00e0.<\/p><\/li><li><p><strong>200GBASE-FR4 \/ LR4<\/strong> \u2013 Soluzioni SMF a quattro corsie che consentono rispettivamente portate di 2 km e 10 km.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">3cd definisce parametri elettrici e ottici per queste interfacce, inclusi TDECQ, OMAouter del trasmettitore, sensibilit\u00e0 del ricevitore e obiettivi di BER per corsia.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Casi d\u2019uso implementativi nei moderni data center<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >50G su singola corsia per server<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Molti data center iperscalabili e aziendali adottano<br> <strong>50G SFP56<br><\/strong> interfacce per i collegamenti di accesso ai server, sostituendo il 25G come larghezza di banda standard per il nodo.<br>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >100G come livello di uplink<br><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Utilizzando 2 corsie da 50G, i collegamenti da 100G rimangono uno strato primario di aggregazione tra gli switch Top-of-Rack (ToR) e quelli leaf.<br>. <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472577.htm\">Moduli ottici 100G QSFP28<\/a> oppure moduli SFP-DD offrono densit\u00e0 efficiente e compatibilit\u00e0 retroattiva.<br>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >200G per le reti leaf-to-spine<br><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473139.htm\">200G QSFP56<br><\/a> o trasceiver QSFP-DD abilitano architetture a quattro corsie da 50G con flessibilit\u00e0 di breakout. Una singola porta da 200G pu\u00f2 essere suddivisa in<br> <strong>4\u00d750G<br><\/strong> per server o nodi di aggregazione.<br>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Flessibilit\u00e0 di breakout<br><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019architettura basata su corsie rende lo standard 802.3cd ideale per:<br><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>200G QSFP56 \u2192 4\u00d750G SFP56<br><\/p><\/li><li><p>100G QSFP28 \u2192 2\u00d750G SFP56<br><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ci\u00f2 si allinea perfettamente alle transizioni verso i server di nuova generazione da 25G a 50G.<br>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Selezione dei trasceiver ottici appropriati per IEEE 802.3cd<br><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480.webp\" alt=\"802.3cd-compliant optical transceivers\" class=\"wp-image-3514\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Nella progettazione di una rete 50G\/100G\/200G, la scelta dei trasceiver deve corrispondere al<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-physical-medium-dependent-pmd\/\">PMD<\/a> tipo, alla portata in fibra e al fattore di forma della porta dello switch.<br>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Per le implementazioni IEEE 802.3cd, LINK-PP fornisce le seguenti categorie di prodotti:<br><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Trasceiver ottici 50G (SFP56 \/ QSFP28)<br><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Per 50GBASE-SR\/FR\/LR a singola corsia e accesso server a 50G:<br><br\/>\ud83d\udd17 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27046-50g-qsfp28-sfp56.htm\">https:\/\/www.l-p.com\/store-27046-50g-qsfp28-sfp56.htm<\/a><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Trasceiver ottici 100G (QSFP28 \/ SFP-DD)<br><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ideali per uplink da 2\u00d750G, aggregazione spine da 100G e applicazioni DR\/FR\/LR:<br><br\/>\ud83d\udd17 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\">https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm<\/a><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Trasceiver ottici 200G (QSFP-DD \/ QSFP56)<br><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Progettati per reti leaf-spine da 4\u00d750G e compatibilit\u00e0 di breakout:<br><br\/>\ud83d\udd17 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26224-200g-qsfp-dd-qsfp56.htm\">https:\/\/www.l-p.com\/store-26224-200g-qsfp-dd-qsfp56.htm<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Questi moduli supportano la modulazione PAM4 e soddisfano gli obiettivi IEEE di interoperabilit\u00e0, quali le prestazioni TDECQ, la sensibilit\u00e0 del ricevitore e la coerenza del BER per corsia.<br>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Checklist di interoperabilit\u00e0 e validazione<br><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Per garantire un\u2019implementazione affidabile di 802.3cd, gli ingegneri verificano tipicamente:<br><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Il tipo corretto di PMD<br><\/strong> (SR, FR, LR, DR) per il bilancio del collegamento e la portata.<br>.<\/p><\/li><li><p><strong>La corrispondenza del fattore di forma<br><\/strong> (SFP56, QSFP28, QSFP56, QSFP-DD).<br>.<\/p><\/li><li><p><strong>Livelli di potenza ottica<\/strong> compresi OMAouter e potenza media di trasmissione.<br>.<\/p><\/li><li><p><strong>Sensibilit\u00e0 del ricevitore<br><\/strong> in condizioni di modulazione PAM4 stressate.<br>.<\/p><\/li><li><p><strong>Gli obiettivi di BER per corsia<br><\/strong> and <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/fec-forward-error-correction-in-optical-communication\/\">FEC<\/a> compatibilit\u00e0.<br>.<\/p><\/li><li><p><strong>La mappatura del breakout<br><\/strong> quando si utilizzano endpoint 200G \u2194 50G.<br>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Conclusione<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">IEEE 802.3cd ha stabilito i blocchi tecnici fondamentali per l\u2019odierna<br> <strong>Ethernet 50G, 100G e 200G<br><\/strong>, introducendo la<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\">modulazione PAM4<\/a> nell\u2019implementazione diffusa. La sua architettura basata su corsie consente aggiornamenti della larghezza di banda scalabili ed economicamente efficienti, mantenendo al contempo formati di moduli familiari.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Man mano che i data center continuano a migrare da 25G e 40G verso reti ad alta velocit\u00e0, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473139.htm\">trasceivers ottici conformi allo standard IEEE 802.3cd<\/a>\u2014come le famiglie di prodotti LINK-PP da 50G\/100G\/200G\u2014offrono una base affidabile per la connettivit\u00e0 di prossima generazione.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Per specifiche dettagliate e selezione dei prodotti, esplora <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">LINK-PP<\/a> l\u2019intera gamma di trasceivers compatibili con lo standard IEEE 802.3cd.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Termini ottici ed elettrici chiave nello standard IEEE 802.3cd (Mini glossario)<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2605 TDECQ (Transmitter and Dispersion Eye Closure for PAM4)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Il TDECQ \u00e8 una metrica di qualit\u00e0 del trasmettitore utilizzata nelle interfacce basate su PAM4. Quantifica quanto il diagramma dell\u2019occhio ottico si \u201cchiuda\u201d dopo che il segnale ha subito dispersione, rumore e altre degradazioni del canale. Un <strong>valore TDECQ pi\u00f9 basso<\/strong> indica un segnale PAM4 pi\u00f9 pulito e con un margine di collegamento migliore. Lo standard IEEE 802.3cd utilizza il TDECQ come requisito principale per i trasmettitori ottici da 50G, 100G e 200G.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2605 OMAouter (Outer Optical Modulation Amplitude)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019OMAouter rappresenta l\u2019 <strong>differenza tra i livelli di potenza ottica pi\u00f9 alto e pi\u00f9 basso<\/strong> (Livello 3 e Livello 0) in un segnale PAM4. Poich\u00e9 PAM4 utilizza quattro livelli discreti, OMAouter fornisce una rappresentazione pi\u00f9 accurata della profondit\u00e0 di modulazione rispetto alla potenza media. Un <strong>valore pi\u00f9 elevato di OMAouter<\/strong> migliora generalmente la sensibilit\u00e0 del ricevitore e contribuisce a garantire prestazioni conformi agli standard per 50GBASE-SR\/FR\/LR e le relative varianti multilane.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2605 BER (Bit Error Rate, tasso di errore su bit)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/understanding-what-is-bit-error-rate\/\">BER<\/a> misura il rapporto tra bit errati e il numero totale di bit trasmessi. IEEE 802.3cd specifica <strong>obiettivi di BER per singola lane<\/strong>, tipicamente utilizzando un <strong>obiettivo di BER pre-FEC pari a 2,4\u00d710\u207b\u2074<\/strong> per le lane PAM4. Con una robusta correzione degli errori in avanti (FEC, ad esempio KP4 FEC), il BER post-FEC raggiunge l'affidabilit\u00e0 richiesta per le reti data center iperscalari e cloud.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Domande frequenti (FAQ)<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Che cos\u2019\u00e8 IEEE 802.3cd?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">IEEE 802.3cd \u00e8 uno standard Ethernet che definisce le specifiche del livello fisico per <strong>50GbE, 100GbE e 200GbE<\/strong> mediante <strong>modulazione PAM4<\/strong>. Include interfacce quali <strong>50GBASE-SR\/FR\/LR<\/strong>, <strong>100GBASE-SR2<\/strong>, and <strong>200GBASE-SR4<\/strong>, rivolte agli ambienti moderni di data center e di networking ad alte prestazioni.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Qual \u00e8 il formato di modulazione utilizzato da IEEE 802.3cd?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">IEEE 802.3cd impone l\u2019uso di <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-physical-medium-dependent-pmd\/\"><strong>PAM4 (modulazione di ampiezza degli impulsi a 4 livelli)<\/strong><\/a> PAM4 per tutte le interfacce da 50 G per lane. PAM4 raddoppia il bitrate per lane rispetto a NRZ mantenendo la stessa velocit\u00e0 di trasmissione (baud rate), consentendo architetture Ethernet scalabili da 50G, 100G e 200G.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >IEEE 802.3cd supporta la compatibilit\u00e0 all\u2019indietro con NRZ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00ec, in molti casi i collegamenti basati su PAM4 possono coesistere con interfacce NRZ <strong>purch\u00e9 la porta host, l\u2019interfaccia elettrica e il modulo ottico siano progettati per supportare ambienti misti<\/strong>. Tuttavia, PAM4 e NRZ non possono interoperare su un singolo collegamento: entrambe le estremit\u00e0 devono utilizzare lo stesso formato di modulazione.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Quali sono gli scenari applicativi tipici di IEEE 802.3cd?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">IEEE 802.3cd \u00e8 ampiamente utilizzato per:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>accesso server a 50G (SFP56, QSFP28)<\/p><\/li><li><p>livelli spine\/aggregazione a 100G<\/p><\/li><li><p>fabric leaf-spine a 200G<\/p><\/li><li><p>reti cloud, AI\/ML e iperscalari<\/p><\/li><li><p>uplink a 50G per lane in architetture modulari (2\u00d750G, 4\u00d750G)<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Quali transceiver ottici sono conformi a IEEE 802.3cd?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">IEEE 802.3cd supporta un\u2019ampia gamma di moduli ottici da 50G, 100G e 200G, tra cui:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>50GBASE-SR\/FR\/LR<\/strong> (SFP56 \/ QSFP28) per 50GbE a singola lane<\/p><\/li><li><p><strong>100GBASE-SR2<\/strong> e moduli breakout 2\u00d750G (QSFP28 \/ SFP-DD)<\/p><\/li><li><p><strong>200GBASE-SR4\/DR4\/FR4<\/strong> (QSFP-DD \/ QSFP56)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">LINK-PP<\/a> offre opzioni conformi a IEEE 802.3cd per tutte le classi di velocit\u00e0.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Qual \u00e8 la relazione tra IEEE 802.3cd e IEEE 802.3bs (400G) e 802.3cu?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/knowledge-center\/ieee-802-3bs-200g-400g-ethernet-standard\/\"><strong>3bs<\/strong><\/a> definisce 400GbE e si basa anch\u2019esso su lane da 50G, ma si concentra su architetture con un numero maggiore di lane (ad esempio, 8\u00d750G).<\/p><\/li><li><p><strong>3cu<\/strong> estende 100G\/400G ad applicazioni su fibra monomodale (SMF) a portata maggiore (DR\/FR\/LR).<\/p><\/li><li><p><strong>3cd<\/strong> colma il divario per <strong>Ethernet a 50G per lane, sia a singola che a pi\u00f9 lane<\/strong>, abilitando percorsi di migrazione scalabili da 25G \u2192 50G \u2192 100G\/200G \u2192 400G.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >IEEE 802.3cd \u00e8 adatto ai carichi di lavoro AI\/ML e HPC di nuova generazione?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00ec. L\u2019architettura <strong>PAM4 da 50G per lane dello standard<\/strong> \u00e8 allineata alle fabric ad alta larghezza di banda utilizzate nei cluster AI, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/it\/glossary\/what-is-hpc-high-performance-computing\/\">nei sistemi HPC<\/a>, e nelle reti GPU su larga scala. Consente topologie spine-leaf a bassa latenza con opzioni flessibili di breakout, come 4\u00d750G o 2\u00d7100G.<\/p>","protected":false},"excerpt":{"rendered":"<p>Scopri cosa definisce IEEE 802.3cd per Ethernet 50G, 100G e 200G. Esplora la tecnologia PAM4, i principali PMD, gli scenari di impiego e i transceiver ottici LINK-PP adatti.<\/p>","protected":false},"author":1,"featured_media":3515,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13,24,26],"class_list":["post-3516","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules","tag-link-pp","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/3516","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/comments?post=3516"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/3516\/revisions"}],"predecessor-version":[{"id":11328,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/posts\/3516\/revisions\/11328"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media\/3515"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/media?parent=3516"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/categories?post=3516"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/it\/wp-json\/wp\/v2\/tags?post=3516"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}