{"id":5280,"date":"2025-09-01T00:00:00","date_gmt":"2025-09-01T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/optical-transceiver-insertion-loss-definition-impact\/"},"modified":"2026-06-22T07:58:23","modified_gmt":"2026-06-22T07:58:23","slug":"optical-transceiver-insertion-loss-definition-impact","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/id\/knowledge-center\/optical-transceiver-insertion-loss-definition-impact","title":{"rendered":"Kerugian Masukan Transceiver Optik: Definisi, Pengukuran, dan Dampaknya"},"content":{"rendered":"<h2 class=\"wp-block-heading\" >\u25b6 Pendahuluan<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Dalam komunikasi optik, setiap pecahan desibel dapat menentukan apakah suatu tautan berjalan sempurna atau gagal di bawah beban. Salah satu parameter paling penting adalah <strong>kerugian masukan (IL)<\/strong> \u2014 jumlah daya optik yang hilang ketika cahaya melewati suatu komponen, konektor, atau tautan serat. Insinyur menganggap kerugian masukan sebagai pengukuran kunci dalam menghitung anggaran tautan, menguji instalasi serat, dan memilih <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">transceiver optik<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Artikel ini menjelaskan apa itu kerugian masukan, cara mengukurnya, nilai-nilai tipikalnya, serta mengapa hal ini penting bagi kinerja modul optik seperti yang disuplai oleh <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/page\/aboutus.htm\"><strong>LINK-PP<\/strong><\/a>.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/283194d74a2a4ae4857bfb467fb58fca.webp\" alt=\"Optical transceiver insertion loss visualized across LC and MPO connectors in a data center link\" class=\"wp-image-5276\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/283194d74a2a4ae4857bfb467fb58fca.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/283194d74a2a4ae4857bfb467fb58fca-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/283194d74a2a4ae4857bfb467fb58fca-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/283194d74a2a4ae4857bfb467fb58fca-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/283194d74a2a4ae4857bfb467fb58fca-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Apa Itu \u201cKerugian Masukan Transceiver Optik\u201d?<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Definisi dalam istilah sederhana<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Kerugian masukan adalah penurunan daya sinyal antara input dan output suatu komponen atau tautan. Nilainya selalu dinyatakan dalam <strong>desibel (dB)<\/strong>. Semakin rendah IL, semakin banyak cahaya yang mencapai penerima.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Secara matematis:<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"320\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/222f8c7683aa4833bd4b9e10f9448198.webp\" alt=\"Optical Transceiver Insertion Loss\" class=\"wp-image-5277\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/222f8c7683aa4833bd4b9e10f9448198.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/222f8c7683aa4833bd4b9e10f9448198-300x80.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/222f8c7683aa4833bd4b9e10f9448198-1024x273.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/222f8c7683aa4833bd4b9e10f9448198-768x205.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/222f8c7683aa4833bd4b9e10f9448198-18x5.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Di mana:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Pin<\/strong> = daya optik input<\/p><\/li><li><p><strong>Pout<\/strong> = daya optik output<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Jika Anda memasukkan daya sebesar \u20132 dBm ke dalam serat dan menerima \u20132.5 dBm di ujung jauh, maka kerugian masukannya adalah 0.5 dB.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >Mengapa IL penting<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Karena penerima optik memerlukan daya input minimum tertentu agar beroperasi dengan benar, kelebihan IL secara langsung mengurangi margin sistem dan dapat menyebabkan penerima berada di bawah ambang sensitivitas. Hal ini mengakibatkan tingkat <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/id\/glossary\/understanding-what-is-bit-error-rate\/\">kesalahan bit (BER)<\/a> yang lebih tinggi atau bahkan putusnya koneksi.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Penyebab Kerugian Masukan<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Kerugian masukan tidak dapat dihindari, tetapi dapat diminimalkan melalui desain dan perawatan yang baik. Faktor utama penyebabnya meliputi:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Kerugian sambungan konektor<\/strong> \u2014 Celah kecil, ketidaksejajaran, atau kotoran di antara dua konektor serat meningkatkan kerugian.<\/p><\/li><li><p><strong>Atenuasi serat<br><\/strong> \u2014 Bahkan serat mode-tunggal berkualitas tinggi memiliki atenuasi intrinsik (misalnya, ~0,35 dB\/km pada 1310 nm, ~0,2 dB\/km pada 1550 nm).<\/p><\/li><li><p><strong>Kehilangan sambungan (splice)<br><\/strong> \u2014 Sambungan mekanis atau fusi biasanya menambahkan 0,05\u20130,3 dB.<\/p><\/li><li><p><strong>Kerugian lenturan<\/strong> \u2014 Lenturan tajam atau mikrolenturan menyebabkan kebocoran sinyal.<\/p><\/li><li><p><strong>Kerugian internal dalam modul<\/strong> \u2014 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475859.htm\">Transceiver optik<\/a> memiliki lensa dan antarmuka bawaan yang menambahkan nilai IL kecil.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Cara Mengukur Kerugian Masukan<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >OLTS (Optical Loss Test Set)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Cara paling akurat untuk mengukur IL adalah dengan OLTS: sumber cahaya terkalibrasi di satu ujung tautan dan meter daya di ujung lainnya. Ini adalah standar <strong>Uji sertifikasi Tier-1<\/strong> dalam serat optik.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Langkah-langkah:<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>Hubungkan sumber dan meter dengan kabel referensi yang diketahui.<\/p><\/li><li><p>Ukur daya referensi (Pin).<\/p><\/li><li><p>Hubungkan tautan serat yang diuji.<\/p><\/li><li><p>Ukur daya keluaran (Pout).<\/p><\/li><li><p>Hitung IL = 10\u00b7log10(Pin\/Pout).<\/p><\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" >OTDR (Optical Time Domain Reflectometer)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">OTDR juga dapat memperkirakan IL, tetapi terutama digunakan untuk lokasi kegagalan. Untuk pengujian penerimaan, OLTS lebih disukai.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Tips pengujian di lapangan<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Selalu bersihkan konektor sebelum pengujian \u2014 kontaminasi adalah penyebab utama kehilangan berlebih.<\/p><\/li><li><p>Lakukan pengujian dalam kedua arah (A\u2192B dan B\u2192A), lalu rata-ratakan hasilnya.<\/p><\/li><li><p>Gunakan kabel referensi berkualitas tinggi dengan IL rendah yang telah diketahui.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Nilai Kehilangan Masukan Tipikal<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Angka IL tipikal membantu insinyur merancang anggaran tautan:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Satu konektor:<\/strong> 0,1\u20130,5 dB (polish baik dan bersih).<\/p><\/li><li><p><strong>Sambungan mekanis:<\/strong> 0,2\u20130,5 dB.<\/p><\/li><li><p><strong>Sambungan fusi:<\/strong> 0,05\u20130,1 dB.<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482604.htm\"><strong>Serat mode tunggal<\/strong><\/a><strong> atenuasi:<\/strong> 0,35 dB\/km pada 1310 nm, 0,2 dB\/km pada 1550 nm.<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/488477.htm\"><strong>Serat multimode<\/strong><\/a><strong> atenuasi:<\/strong> 3,0 dB\/km pada 850 nm, 1,0 dB\/km pada 1300 nm.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Sebagai contoh, tautan mode-tunggal sepanjang 10 km pada 1550 nm dengan dua konektor dan dua sambungan mungkin memiliki total IL \u2248 0,2 \u00d7 10 + 0,3 + 0,1 = 2,4 dB.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Kehilangan Masukan dalam Perhitungan Anggaran Tautan<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Anggaran tautan adalah selisih antara daya keluaran pemancar dan sensitivitas penerima, disesuaikan dengan IL dan margin.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Contoh:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Daya pemancar (Tx): 0 dBm<\/p><\/li><li><p>Sensitivitas penerima (Rx): \u201314 dBm<\/p><\/li><li><p>Anggaran yang tersedia = 14 dB<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Jika IL = 10 dB, margin = 4 dB \u2192 <strong>dapat diterima<\/strong>.<br\/>Jika IL = 15 dB, margin = \u20131 dB \u2192 <strong>tautan gagal<\/strong>.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Ini menunjukkan mengapa bahkan pecahan dB pun sangat penting.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Dampak terhadap Transceiver Optik<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Kehilangan masukan berdampak <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">modul optik<\/a> dalam tiga cara utama:<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p><strong>Margin berkurang:<\/strong> IL tinggi mengurangi margin sistem yang tersedia, sehingga tautan menjadi rentan terhadap penuaan atau perubahan suhu.<\/p><\/li><li><p><strong>BER lebih tinggi:<\/strong> Rasio sinyal-terhadap-kebisingan yang lebih rendah di penerima mengakibatkan lebih banyak kesalahan bit.<\/p><\/li><li><p><strong>Jangkauan dipersingkat:<\/strong> Modul yang dirancang untuk jangkauan 40 km mungkin hanya mencapai 30 km jika IL melebihi asumsi.<\/p><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Sebagai contoh, LINK-PP\u2019s <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482907.htm\"><strong>LS-CW3110-40I<\/strong><\/a><strong> transceiver optik<\/strong> dirancang untuk transmisi 40 km 10G. Jika diterapkan dengan IL berlebih (konektor kotor, sambungan buruk), jangkauan efektifnya akan berkurang. Oleh karena itu, pemeriksaan IL merupakan bagian dari upaya memastikan kinerja sesuai spesifikasi lembar data.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Cara Meminimalkan Kerugian Masukan<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Bersihkan konektor<\/strong> sebelum setiap penggunaan dengan tisu bebas serat dan alkohol isopropil.<\/p><\/li><li><p><strong>Periksa ujung serat<\/strong> menggunakan mikroskop serat.<\/p><\/li><li><p><strong>Gunakan penyambungan fusio<\/strong> alih-alih penyambungan mekanis bila memungkinkan.<\/p><\/li><li><p><strong>Hindari lengkungan tajam<\/strong> \u2014 patuhi jari-jari lengkung serat.<\/p><\/li><li><p><strong>Pilih komponen berkualitas<\/strong> \u2014 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">modul<\/a>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-21644-fiber-optic-cages-connectors.htm\">konektor<\/a>, and <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26454-dac-aoc-aec-cables.htm\">kabel patch<\/a> dengan spesifikasi kerugian masukan (IL) yang dijamin.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Di mana LINK-PP membantu<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d9cc5ec3f48c48f3b5b28dfe28abb572.webp\" alt=\"LINK-PP Solutions\" class=\"wp-image-5278\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d9cc5ec3f48c48f3b5b28dfe28abb572.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d9cc5ec3f48c48f3b5b28dfe28abb572-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d9cc5ec3f48c48f3b5b28dfe28abb572-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d9cc5ec3f48c48f3b5b28dfe28abb572-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d9cc5ec3f48c48f3b5b28dfe28abb572-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Jika Anda merancang atau mengoperasikan tautan dalam rentang 1G\u2013800G, LINK-PP menyediakan modul dan konektivitas yang dirancang untuk kompatibilitas, kinerja, serta kualifikasi yang lancar:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Transceiver optik: keluarga SFP\/SFP+, SFP28, QSFP28, QSFP-DD, dan OSFP yang selaras dengan optik Ethernet IEEE. Lihat ikhtisar kami tentang alasan perusahaan memilih modul kami di <a target=\"_blank\" rel=\"nofollow\" href=\"https:\/\/resourceslp.szlogic.cn\/id\/knowledge-center\/why-choose-link-pp-fiber-optical-modules\/\">Mengapa memilih modul serat optik LINK-PP<\/a>.<\/p><\/li><li><p>Konektor dan assembli: konektivitas LC duplex dan kompatibel MPO\/MTP dengan opsi kehilangan rendah untuk melindungi anggaran Anda. Untuk konteks dasar konektor, lihat <a target=\"_blank\" rel=\"nofollow\" href=\"https:\/\/resourceslp.szlogic.cn\/id\/knowledge-center\/common-fiber-connector-types-optical-transceivers\/\">Jenis Konektor Serat Umum dalam Transceiver Optik<\/a>.<\/p><\/li><li><p>Evaluasi menjadi mudah: Minta sampel gratis dan dapatkan dukungan teknis untuk memvalidasi kehilangan masukan (IL) dan anggaran tautan di lingkungan Anda\u2014lihat CTA sampel\/dukungan di halaman toko kami seperti halaman <a target=\"_blank\" rel=\"nofollow\" href=\"https:\/\/www.l-p.com\/store-26155-1g-sfp.htm\">Katalog LINK-PP 1G SFP<\/a>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 FAQ Cepat<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q1: Berapa nilai kehilangan masukan (insertion loss) yang dapat diterima per konektor?<\/strong><br\/>A: Untuk konektor berkualitas tinggi, &lt;0,3 dB merupakan nilai khas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q2: Seberapa sering IL harus diuji?<\/strong><br\/>A: Saat pemasangan dan setelah setiap pemeliharaan besar. Tautan kritis mungkin diuji ulang selama audit terjadwal.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q3: Apakah kehilangan masukan dapat dikurangi setelah pemasangan?<\/strong><br\/>A: Sering kali ya \u2014 membersihkan konektor atau mengulang terminasi sambungan dengan kehilangan tinggi dapat menurunkan IL.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Kesimpulan<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Kehilangan masukan mungkin tampak seperti angka kecil, tetapi dalam jaringan optik berkecepatan tinggi, setiap pecahan desibel sangat penting. Perancangan, pengujian, dan pemeliharaan yang tepat sangat esensial guna memastikan kinerja andal.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bagi insinyur yang menerapkan <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>Transceiver optik LINK-PP<\/strong><\/a>, memeriksa kehilangan masukan merupakan langkah kritis dalam memvalidasi kinerja dunia nyata. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dengan memahami kehilangan masukan, mengujinya secara benar, serta meminimalkannya dalam praktik, operator jaringan dapat membangun tautan yang andal, berkinerja tinggi, dan siap menghadapi masa depan.<\/p>","protected":false},"excerpt":{"rendered":"<p>Pelajari apa itu insertion loss transceiver optik, bagaimana pengaruhnya terhadap link budget, BER, dan FEC. Termasuk angka LC\/MPO, tips kontrol, serta wawasan LINK-PP.<\/p>","protected":false},"author":1,"featured_media":5279,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[19,21,26],"class_list":["post-5280","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-aoc-dac-cables","tag-fiber-optic-cage-and-connector","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/posts\/5280","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/comments?post=5280"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/posts\/5280\/revisions"}],"predecessor-version":[{"id":11203,"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/posts\/5280\/revisions\/11203"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/media\/5279"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/media?parent=5280"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/categories?post=5280"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/tags?post=5280"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}