{"id":3578,"date":"2025-11-28T00:00:00","date_gmt":"2025-11-28T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/glossary\/what-is-physical-medium-dependent-pmd\/"},"modified":"2026-06-22T04:35:06","modified_gmt":"2026-06-22T04:35:06","slug":"what-is-physical-medium-dependent-pmd","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/id\/glossary\/what-is-physical-medium-dependent-pmd","title":{"rendered":"Panduan Praktis PMD (Ketergantungan Medium Fisik) untuk Tautan Optik"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe.webp\" alt=\"PMD (Physical Medium Dependent)\" class=\"wp-image-3574\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>Dependen pada Media Fisik (PMD)<\/strong> sublayer adalah salah satu elemen paling penting dari lapisan fisik Ethernet, namun sering disalahpahami. PMD mendefinisikan cara bit ditransmisikan dan diterima secara fisik melalui media tertentu\u2014serat optik mode tunggal, serat optik mode majemuk, tembaga terpasang langsung, atau backplane listrik.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bagi perancang jaringan, insinyur pengujian, dan tim pengadaan, memahami PMD sangat penting karena spesifikasi PMD secara langsung memengaruhi <strong>interoperabilitas yang lebih baik dan garansi yang lebih panjang.<\/strong>, <strong>jangkauan<\/strong>, <strong>integritas sinyal<\/strong>, and <strong>pemilihan transceiver<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Panduan ini memberikan penjelasan profesional dan selaras dengan standar mengenai PMD, termasuk parameter yang harus Anda evaluasi saat memilih <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">transceiver optik<\/a> seperti modul SFP, SFP+, dan QSFP.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Apa Itu Sublayer Dependen pada Media Fisik (PMD)?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>Dependen pada Media Fisik (PMD)<\/strong> sublayer adalah blok fungsional terendah dari <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/id\/knowledge-center\/ieee-802-3-ethernet-standard-explained\/\">IEEE 802.3<\/a> PHY. Sublayer ini mendefinisikan <strong>karakteristik optik atau listrik<\/strong> yang diperlukan untuk transmisi sukses melalui media yang dipilih.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pada produk nyata, PMD sesuai dengan antarmuka depan transceiver optik\u2014laser-nya, fotodioda penerima, sirkuit modulasi, dan komponen terkait lainnya.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Apa yang Dikendalikan PMD<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Panjang gelombang optik dan lebar spektrum<\/p><\/li><li><p>Daya rata-rata kirim (Tx) dan kondisi peluncuran<\/p><\/li><li><p>Sensitivitas penerima (Rx) dan batas kelebihan beban<\/p><\/li><li><p>Optik <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/id\/knowledge-center\/optical-transceiver-return-loss-back-reflection-guide\/\">rugi kembali<\/a> dan rasio ekstinksinya<\/p><\/li><li><p>Jenis serat yang didukung dan jarak tautan<\/p><\/li><li><p>Masker mata kirim\/terima listrik (untuk PHY listrik)<\/p><\/li><li><p>Definisi titik uji untuk pengukuran kesesuaian<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">PMD berperan sebagai <strong>jembatan antara logika PHY yang distandarkan dan dunia fisik<\/strong>, memastikan bahwa transceiver dari berbagai vendor dapat saling beroperasi pada instalasi serat yang sama.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f PMD vs. Sublayer PHY Lainnya<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Arsitektur PHY Ethernet umumnya mencakup:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/id\/glossary\/pcs-physical-coding-sublayer-ethernet-explained\/\"><strong>PCS (Sublapisan Pengkodean Fisik)<\/strong> <\/a>\u2014 pengkodean, 64b\/66b, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/id\/glossary\/fec-forward-error-correction-in-optical-communication\/\">FEC<br><\/a>, dan distribusi jalur<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/id\/glossary\/pma-physical-medium-attachment-ethernet-explained\/\"><strong>PMA (Lampiran Media Fisik)<\/strong><\/a> \u2014 serialisasi\/deserialisasi, pemulihan clock<\/p><\/li><li><p><strong>PMD (Bergantung pada Media Fisik)<\/strong> \u2014 parameter optik\/listrik spesifik media<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">PMD adalah bagian yang secara langsung terkait dengan anggaran optik dan jenis media.<br\/>Satu MAC dapat mendukung beberapa PMD (misalnya, SR, LR, ER), masing-masing dioptimalkan untuk jangkauan atau media yang berbeda.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Mengapa PMD Penting dalam Jaringan Nyata<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34.webp\" alt=\"Why PMD Matters in Real Networks\" class=\"wp-image-3575\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Interoperabilitas yang Dijamin<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Hanya modul yang sesuai dengan spesifikasi PMD yang sama yang dapat dihubungkan secara andal. Panjang gelombang, level daya, dan sensitivitas harus selaras dengan persyaratan IEEE.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Jangkauan Tautan yang Dapat Diprediksi<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Parameter PMD menentukan anggaran kehilangan tautan. Jika suatu modul menetapkan daya Tx antara \u20133 dBm hingga +3 dBm dan sensitivitas Rx sebesar \u201314 dBm, anggaran optik yang dapat digunakan dibangun dari angka-angka ini.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Pengujian dan Kepatuhan yang Akurat<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PMD menetapkan titik uji standar (misalnya, TP2, TP3), sehingga daya optik, jitter, dan diagram mata diukur secara konsisten.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Keandalan Seiring Waktu<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Modul dengan margin PMD yang lebih kuat lebih tahan terhadap penuaan, variasi suhu, kontaminasi serat, dan refleksi konektor dibandingkan modul yang dirancang hanya memenuhi persyaratan minimum.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Parameter PMD Utama yang Harus Anda Evaluasi<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Setiap spesifikasi PMD mencakup beberapa metrik optik dan elektrik kritis. Memahaminya memastikan pemilihan modul yang tepat.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Panjang Gelombang (\u03bb) dan Lebar Spektrum<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Nilai umum meliputi:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/id\/knowledge-center\/850nm-optical-transceivers-for-short-reach-mmf-transmission\/\"><strong>850nm<\/strong><\/a> \u2014 jarak pendek multimode (SR)<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/id\/knowledge-center\/1310nm-optical-module-applications-performance-comparison\/\"><strong>1310 nm<\/strong><\/a> \u2014 jarak menengah mode tunggal (LR)<\/p><\/li><li><p>Kisaran spesifik untuk varian LX, BX, CWDM, dan DWDM<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Lebar spektrum memengaruhi kinerja dispersi, terutama pada tautan jarak jauh.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Daya Rata-rata Pemancar (Tx)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Menetapkan daya keluaran minimum dan maksimum.<br\/>Terlalu rendah \u2192 tautan mungkin tidak mencapai penerima.<br\/>Terlalu tinggi \u2192 dapat melebihi kapasitas penerima atau menyebabkan efek nonlinier.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Sensitivitas dan Overload Penerima<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Sensitivitas:<\/strong> tingkat daya terendah di mana penerima memenuhi persyaratan BER<\/p><\/li><li><p><strong>Overload:<\/strong> daya masukan maksimum sebelum terjadi distorsi sinyal<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Kedua nilai ini menentukan anggaran <strong>daya optik yang dapat digunakan<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Rasio Ekstinsi dan Rugi Balik Optik<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/id\/glossary\/extinction-ratio-importance-signal-quality-data-reliability\/\"><strong>Rasio ekstinsi<\/strong><\/a> memastikan perbedaan yang jelas antara logika \u201c1\u201d dan \u201c0\u201d.\u201d<\/p><\/li><li><p><strong>Rugi balik optik<\/strong> menentukan toleransi terhadap refleksi\u2014kritis pada rentang mode tunggal yang panjang.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Jenis Serat dan Jangkauan yang Didukung<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Tabel PMD menetapkan:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Jangkauan untuk multimode OM2\/OM3\/OM4<\/p><\/li><li><p>Jangkauan untuk mode tunggal G.652\/G.655<\/p><\/li><li><p>Panjang maksimum yang didukung berdasarkan anggaran daya IEEE<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f PMD dalam Pemilihan Transceiver Optik<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Saat memilih modul optik untuk <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/id\/knowledge-center\/what-is-a-data-center\/\">pusat data<\/a>, jaringan industri atau infrastruktur telekomunikasi, memastikan kepatuhan PMD menjamin:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Interoperabilitas IEEE yang sebenarnya<\/p><\/li><li><p>Jangkauan yang tepat melalui serat optik yang ada<\/p><\/li><li><p>Margin kehilangan (loss) yang dapat diprediksi<\/p><\/li><li><p>Kinerja andal di lingkungan bersuhu ekstrem atau berisik<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Misalnya, memilih antara <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475415.htm\"><strong>10GBASE-SR<\/strong><\/a>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475586.htm\"><strong>10GBASE-LR<\/strong><\/a>, and <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476054.htm\"><strong>10GBASE-ER<\/strong><\/a> pada dasarnya berarti memilih PMD berbeda yang dioptimalkan untuk jarak 300 m, 10 km, atau 40 km.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b.webp\" alt=\"10GBASE-SR, 10GBASE-LR, and 10GBASE-E\" class=\"wp-image-3576\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Contoh Tabel Ringkasan PMD <\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Ganti nilai-nilai tersebut dengan parameter tepat dari <\/em><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/file\/datasheet\/ls-sm3110-10c.pdf\"><em>lembar spesifikasi modul SFP+<\/em><\/a><em>.<\/em><\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 220px;\"\/><col style=\"width: 214px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Atribut PMD<\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>Nilai Tipikal<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Deskripsi<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Panjang gelombang<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>1310 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Laser single-mode, jangkauan jauh<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Daya Tx (Min\/Maks)<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>\u20133 dBm \/ +3 dBm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Kisaran daya pancar<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Sensitivitas Rx<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>\u201314 dBm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Daya minimum untuk kepatuhan BER<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Overload Rx<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>+1 dBm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Input maksimum yang aman<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Reach<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>10km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Bergantung pada kehilangan serat dan sambungan (splices)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Rasio Ekstinsi<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>\u2265 3,5 dB<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Kualitas modulasi laser<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Pengujian dan Kepatuhan PMD<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Pengujian PMD yang terdefinisi dengan baik menjamin interoperabilitas yang andal.<br\/>Pengukuran utama meliputi:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Daya optik di pemancar dan penerima<\/p><\/li><li><p>Kepatuhan masker mata (eye-mask)<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/id\/knowledge-center\/jitter-in-optics-causes-effects-measurement-reduction\/\">Jitter<\/a> dan margin kebisingan (noise margin)<\/p><\/li><li><p>Pengujian pada titik suhu yang telah ditentukan<\/p><\/li><li><p>Verifikasi sensitivitas penerima dalam kondisi terganggu (stressed)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Pengukuran-pengukuran ini selaras dengan prosedur kepatuhan IEEE.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Pemecahan Masalah Kegagalan Terkait PMD<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Daya yang diterima rendah<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Periksa kebersihan konektor, kehilangan serat yang tak terduga, atau pemasangan patch berlebihan.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Koneksi berkedip-kedip (link flaps) pada rentang jarak jauh<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Periksa penuaan daya pengiriman (Tx power) atau sensitivitas yang mendekati batas\u2014anggaran optis mungkin terlalu ketat.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Multimode mencapai jarak lebih pendek daripada yang diharapkan<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Verifikasi kompatibilitas OM3\/OM4; keterbatasan bandwidth bersifat spesifik terhadap medium.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Kesimpulan<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>Dependen pada Media Fisik (PMD)<\/strong> sublayer merupakan salah satu konsep dasar di balik interoperabilitas lapisan fisik Ethernet. Dengan menetapkan panjang gelombang optis, kisaran daya, sensitivitas, jangkauan, dan titik pengujian, PMD memastikan bahwa transceiver dari berbagai vendor beroperasi secara dapat diprediksi pada infrastruktur serat yang sama.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bagi organisasi yang menerapkan atau meningkatkan jaringan, memahami PMD sangat penting untuk memilih modul optis yang tepat serta merancang tautan yang andal, sesuai standar, dan siap untuk masa depan.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>transceiver optik LINK-PP<\/strong><\/a> mencakup spesifikasi PMD yang didefinisikan secara jelas, menjadikannya pilihan unggul untuk desain jaringan yang tangguh dan selaras dengan standar.<\/p>","protected":false},"excerpt":{"rendered":"<p>Ketergantungan Medium Fisik (PMD) menetapkan aturan optik dan elektris suatu PHY\u2014panjang gelombang, daya, jangkauan, dan titik uji. Pahami spesifikasi PMD dan bagaimana spesifikasi tersebut membimbing pemilihan transceiver.<\/p>","protected":false},"author":1,"featured_media":3577,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[27],"tags":[24,26],"class_list":["post-3578","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-glossary","tag-link-pp","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/posts\/3578","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/comments?post=3578"}],"version-history":[{"count":5,"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/posts\/3578\/revisions"}],"predecessor-version":[{"id":10826,"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/posts\/3578\/revisions\/10826"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/media\/3577"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/media?parent=3578"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/categories?post=3578"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/tags?post=3578"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}