{"id":3425,"date":"2025-12-05T00:00:00","date_gmt":"2025-12-05T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/middle-of-rack-mor-switch-guide\/"},"modified":"2026-06-22T04:18:19","modified_gmt":"2026-06-22T04:18:19","slug":"middle-of-rack-mor-switch-guide","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/id\/knowledge-center\/middle-of-rack-mor-switch-guide","title":{"rendered":"Switch Middle-of-Rack MoR: Definisi, Kasus Penggunaan, dan Cara Memilih"},"content":{"rendered":"<p class=\"wp-block-paragraph\">A <strong>Saklar Middle-of-Rack (MoR)<\/strong> adalah saklar lapisan akses pusat data yang dipasang di <strong>bagian tengah rak server<\/strong>, diposisikan secara strategis untuk memberikan jarak kabel yang seimbang bagi semua server. Arsitektur MoR menawarkan kompromi antara kesederhanaan <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/id\/knowledge-center\/what-is-a-tor-top-of-rack-switch\/\"><strong>Top-of-Rack (ToR)<\/strong><\/a> dan manajemen terpusat dari <strong>End-of-Row (EoR)<\/strong>, sehingga cocok untuk pusat data berukuran menengah dan perusahaan.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b5fd8c8892374c179f7be1e373e955b8.png\" alt=\"What is a MoR Switch?\" class=\"wp-image-3421\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b5fd8c8892374c179f7be1e373e955b8.png 1536w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b5fd8c8892374c179f7be1e373e955b8-300x200.png 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b5fd8c8892374c179f7be1e373e955b8-1024x683.png 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b5fd8c8892374c179f7be1e373e955b8-768x512.png 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b5fd8c8892374c179f7be1e373e955b8-18x12.png 18w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Apa Itu Saklar MoR?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A <strong>Saklar MoR (saklar Middle-of-Rack)<\/strong> adalah saklar Ethernet yang ditempatkan di sekitar posisi <strong>U tengah<\/strong> kabinet server. Tujuannya adalah mengagregasi lalu lintas dari semua server dalam rak tersebut dan menghubungkannya ke saklar agregasi atau spine. Dengan menempatkan saklar di tengah rak, panjang kabel menjadi lebih seragam, meningkatkan estetika serta mengurangi tekanan pada konektor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">MoR umumnya diterapkan dengan <strong>downlink 10G, 25G, atau 50G<\/strong> and <strong>uplink 40G\/100G\/200G<\/strong>, tergantung beban kerja dan generasi pusat data.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Cara Kerja Arsitektur Middle-of-Rack (MoR)<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Kabel Seimbang untuk Rak Berukuran Besar atau Beragam Tinggi<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Berbeda dengan model ToR\u2014di mana saklar berada tepat di bagian atas\u2014MoR mengurangi variasi ekstrem pada panjang kabel. Hal ini sangat bernilai dalam:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Rak berkepadatan tinggi (42U \/ 48U)<\/p><\/li><li><p>Rak dengan ketinggian server beragam (1U, 2U, 4U)<\/p><\/li><li><p>Lingkungan yang membutuhkan manajemen kabel rapi dan simetris<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Pemeliharaan dan Aliran Udara yang Disederhanakan<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Saklar MoR<\/strong> dapat ditempatkan di zona rak yang menguntungkan secara termal, sehingga meminimalkan dampak terhadap pola aliran udara. Teknisi juga dapat mengakses saklar lebih mudah dari depan atau belakang rak.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"402\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2fd63391b406485785e238dcd77a9b24.jpg\" alt=\"MoR (middle-of-rack) architecture\" class=\"wp-image-3422\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2fd63391b406485785e238dcd77a9b24.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2fd63391b406485785e238dcd77a9b24-300x118.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2fd63391b406485785e238dcd77a9b24-768x302.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2fd63391b406485785e238dcd77a9b24-18x7.jpg 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Perbandingan MoR vs ToR vs EoR: Perbedaan Utama<\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 168px;\"\/><col style=\"width: 185px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"168\"><p>Kategori<\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"185\"><p><strong>MoR <\/strong><br\/><strong>(Middle-of-Rack)<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/id\/knowledge-center\/what-is-a-tor-top-of-rack-switch\/\"><strong>ToR <\/strong><br\/><strong>(Top-of-Rack)<\/strong><\/a><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>AoB<\/strong><br\/><strong> (End-of-Row)<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"168\"><p><strong>Lokasi Saklar<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"185\"><p>Tengah rak<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Atas rak<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Ujung lorong<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"168\"><p><strong>Kabel<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"185\"><p>Seragam<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Singkat<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lama<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"168\"><p><strong>Efisiensi daya rendah<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"185\"><p>Tata letak seimbang; aliran udara baik; kabel rapi<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Penataan kabel mudah; modular<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Manajemen terpusat; jumlah saklar lebih sedikit<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"168\"><p><strong>Aplikasi:<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"185\"><p>Lebih banyak kabel dibanding ToR; saklar tersebar<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Memerlukan lebih banyak saklar; biaya meningkat<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Kabel masif; penataan lebih kompleks<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Kapan Memilih MoR Daripada ToR atau EoR<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">pilih <strong>MoR<\/strong> ketika:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Anda memiliki kabinet server tinggi dan menginginkan panjang kabel yang simetris<\/p><\/li><li><p>Anda membutuhkan manajemen kabel yang lebih rapi<\/p><\/li><li><p>Switch ToR sulit diposisikan karena kendala daya\/aliran udara<\/p><\/li><li><p>Anda menginginkan jumlah kabel per server lebih sedikit daripada EoR, tetapi jumlah switch lebih sedikit daripada ToR<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">pilih <strong>ToR<\/strong> ketika Anda menginginkan <strong>pemasangan kabel paling sederhana<\/strong> dan modularitas maksimal.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">pilih <strong>AoB<\/strong> ketika Anda membutuhkan <strong>manajemen switch terpusat<\/strong> dan jumlah perangkat minimal.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Transceiver Optik yang Digunakan pada Switch MoR<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Switch MoR umumnya mendukung jenis transceiver yang sama seperti <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/id\/knowledge-center\/what-is-a-tor-top-of-rack-switch\/\">switch ToR<\/a>, tergantung pada kecepatan port. Jenis modul paling umum meliputi:<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a45f2be5655c4b9bb3d2b48f4a983975.webp\" alt=\"optical modules\" class=\"wp-image-3423\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a45f2be5655c4b9bb3d2b48f4a983975.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a45f2be5655c4b9bb3d2b48f4a983975-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a45f2be5655c4b9bb3d2b48f4a983975-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a45f2be5655c4b9bb3d2b48f4a983975-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a45f2be5655c4b9bb3d2b48f4a983975-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Modul Downlink (Server-ke-MoR)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Digunakan untuk koneksi NIC server:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>SFP+ 10GBASE-SR\/LR<\/strong> (<a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26192-10g-sfp.htm\">10G<\/a>)<\/p><\/li><li><p><strong>SFP28 25GBASE-SR\/LR<\/strong> (<a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26225-25g-sfp28.htm\">25G<\/a>)<\/p><\/li><li><p><strong>QSFP28<\/strong> (<a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491591.htm\">50G<br><\/a>)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Modul-modul ini terhubung langsung ke kartu jaringan server menggunakan kabel serat optik jarak pendek atau kabel DAC\/AOC.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Modul Uplink (MoR-ke-agregasi)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Digunakan untuk uplink ke switch leaf\/spine:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26153-40g-qsfp.htm\"><strong>QSFP+ <\/strong><\/a><strong>40GBASE-SR4\/LR4<\/strong><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>QSFP28<\/strong><\/a><strong> 100GBASE-SR4\/LR4\/CWDM4<\/strong><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472016.htm\"><strong>QSFP-DD<\/strong><\/a><strong> Modul 200G \/ 400G<\/strong> di lingkungan yang ditingkatkan<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Untuk perusahaan dan pusat data menengah, <strong>uplink 40G dan 100G<\/strong> merupakan yang paling umum.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >H3: Modul Kompatibel LINK-PP untuk Implementasi MoR<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">LINK-PP menawarkan beragam lengkap modul <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>SFP\/SFP+\/SFP28\/QSFP+<\/strong> transceiver optik <\/a>yang kompatibel dengan vendor switch utama.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Catatan praktis: Pastikan kompatibilitas antara modul dan vendor switch (atau gunakan modul OEM-kompatibel yang telah teruji) serta verifikasi kompatibilitas mundur port\u2014port SFP28 dapat menerima modul SFP+ untuk kecepatan lebih rendah, sehingga memudahkan migrasi.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Keuntungan Arsitektur Switching MoR<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Panjang Kabel yang Konsisten<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Mengurangi tegangan dan kelengkungan pada kabel serat optik\/tembaga.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" ><strong>2<\/strong>. Tata Letak Rak yang Seimbang<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Memastikan lingkungan yang rapi dan teratur, ideal untuk pusat data perusahaan.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Pemecahan Masalah Lebih Mudah<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Teknisi dapat mengakses switch tanpa harus memanjat atau melepas peralatan di bagian atas.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Cocok untuk Beban Kerja Campuran<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Mendukung rak yang berisi komputasi, penyimpanan, dan <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/id\/glossary\/what-is-a-gpu-graphics-processing-units\/\">GPU<\/a> server dengan tinggi berbeda-beda.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Kerugian Arsitektur MoR<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Jumlah Switch Lebih Banyak Daripada EoR<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Tetap memerlukan satu switch per rak (seperti ToR), meskipun lokasinya berbeda.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Biaya Potensial Lebih Tinggi Dibandingkan EoR<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">EoR menawarkan jumlah switch secara keseluruhan paling rendah.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Pemasangan Kabel Lebih Kompleks Daripada ToR<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Meskipun seimbang, MoR tetap memiliki jumlah total jalur kabel lebih banyak daripada <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/id\/glossary\/what-is-a-gpu-graphics-processing-units\/\">ToR<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Praktik Terbaik untuk Mengimplementasikan Switch MoR<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Gunakan Panjang Kabel Seragam<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Standarkan panjang kabel untuk menjaga kebersihan rak.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Tempatkan Switch di Zona Netral Termal<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Biasanya di posisi tengah rak sekitar 20\u201325U.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Pilih Transceiver Berdasarkan Jarak<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Kurang dari 30 m: <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26454-dac-aoc-aec-cables.htm\"><strong>DAC\/AOC<\/strong><\/a><\/p><\/li><li><p>1\u2013100 m: <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473141.htm\"><strong>Modul SR<\/strong><\/a><\/p><\/li><li><p>500 m \u2013 10 km: <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/488540.htm\"><strong>Modul LR\/CWDM<\/strong><\/a><\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Validasi Kompatibilitas Vendor<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Gunakan modul kompatibel seperti <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">transceiver LINK-PP<\/a> untuk kinerja yang konsisten.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Tanya Jawab Umum (FAQ)<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25cf Apa itu arsitektur MoR (Middle-of-Rack)?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">MoR mengacu pada desain jaringan pusat data di mana switch ditempatkan di tengah rak. Tata letak ini mempersingkat panjang kabel baik untuk server di posisi atas maupun bawah, meningkatkan organisasi kabel, serta menyeimbangkan aliran udara dalam rak.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25cf Bagaimana MoR berbeda dari ToR dan EoR?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/id\/knowledge-center\/what-is-a-tor-top-of-rack-switch\/\"><strong>ToR (Top-of-Rack):<\/strong><\/a> Switch dipasang di bagian atas rak; pemasangan kabel paling sederhana dan paling banyak digunakan.<\/p><\/li><li><p><strong>MoR (Middle-of-Rack):<\/strong> Switch dipasang di tengah rak; ideal untuk rak dengan server yang dipasang di bagian atas dan bawah.<\/p><\/li><li><p><strong>EoR (End-of-Row):<\/strong> Switch ditempatkan di ujung barisan; menawarkan manajemen terpusat namun memerlukan kabel yang lebih panjang.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">MoR memberikan keseimbangan antara kesederhanaan ToR dan agregasi terpusat EoR.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25cf Transceiver optik apa yang umum digunakan dalam penerapan MoR?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">MoR biasanya digunakan untuk koneksi intra-rak jarak pendek. Optik dan kabel umum meliputi:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Transceiver optik dan kabel jarak pendek:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>SFP28 25G SR (Serat Optik Multimode)<\/strong> \u2014 ideal untuk kabel sepanjang 1\u2013100 m<\/p><\/li><li><p><strong>QSFP28 100G SR4 (Serat Optik Multimode)<\/strong> \u2014 populer untuk uplink 100G<\/p><\/li><li><p><strong>AOC (Kabel Optik Aktif)<\/strong> \u2014 fleksibel dan hemat biaya untuk tautan multi-meter<\/p><\/li><li><p><strong>DAC (Direct Attach Copper)<\/strong> \u2014 opsi berbiaya paling rendah untuk jarak 1\u20133 m<\/p><\/li><li><p><strong>ACC (Kabel Tembaga Aktif)<\/strong> \u2014 alternatif berjarak lebih jauh dibandingkan DAC<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Untuk uplink antar-rak (MoR \u2194 Agregasi):<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>QSFP28 100G LR4<br><\/strong><\/p><\/li><li><p><strong>Modul QSFP56 200G \/ QSFP-DD 400G<\/strong><\/p><\/li><li><p><strong>Modul QSFP+ 40G SR4\/LR4<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25cf Jenis pusat data mana yang diuntungkan oleh MoR?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>High-density server environments<\/p><\/li><li><p>Fasilitas kolokasi dengan standar manajemen kabel yang ketat<\/p><\/li><li><p>Pusat data dengan panel patch dua sisi<\/p><\/li><li><p>Lingkungan cloud atau telekomunikasi yang mengutamakan keseimbangan aliran udara dan kabel simetris<\/p><\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator\" \/>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Kesimpulan<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>Arsitektur switching Middle-of-Rack (MoR)<\/strong> merupakan pilihan serbaguna dan efisien bagi pusat data perusahaan dan skala menengah. Arsitektur ini menawarkan kabel yang seimbang, peningkatan aliran udara, serta pemeliharaan yang lebih mudah, sekaligus mendukung transceiver optik berkecepatan tinggi modern guna pertumbuhan jaringan yang dapat diskalakan. Dengan strategi penempatan switch yang tepat dan modul optik yang dipilih secara cermat\u2014seperti <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26192-10g-sfp.htm\"><strong>SFP+<\/strong><\/a><strong>, <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26225-25g-sfp28.htm\"><strong>SFP28<\/strong><\/a><strong>, and <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26153-40g-qsfp.htm\"><strong>modul QSFP+<\/strong><\/a><strong> dari LINK-PP<\/strong>\u2014MoR mampu memberikan konektivitas andal berkinerja tinggi untuk beragam beban kerja.<\/p>","protected":false},"excerpt":{"rendered":"<p>Temukan apa itu switch MoR (Middle-of-Rack), bagaimana MoR dibandingkan dengan ToR\/EoR, dan modul SFP+\/SFP28\/QSFP mana yang paling cocok \u2014 panduan praktis untuk desain pusat data.<\/p>","protected":false},"author":1,"featured_media":3424,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[19,26],"class_list":["post-3425","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-aoc-dac-cables","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/posts\/3425","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/comments?post=3425"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/posts\/3425\/revisions"}],"predecessor-version":[{"id":10795,"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/posts\/3425\/revisions\/10795"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/media\/3424"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/media?parent=3425"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/categories?post=3425"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/id\/wp-json\/wp\/v2\/tags?post=3425"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}