{"id":7291,"date":"2026-05-14T00:00:00","date_gmt":"2026-05-14T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/glossary\/what-is-crc-cyclic-redundancy-check-errors\/"},"modified":"2026-06-22T03:25:21","modified_gmt":"2026-06-22T03:25:21","slug":"what-is-crc-cyclic-redundancy-check-errors","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/what-is-crc-cyclic-redundancy-check-errors","title":{"rendered":"Qu\u2019est-ce que les erreurs de contr\u00f4le de redondance cyclique (CRC) et pourquoi surviennent-elles\u202f?"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"628\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/57e37cbeac654554aea2d041511b0dfc.jpg\" alt=\"What Is CRC Cyclic Redundancy Check Errors and Why Happen\" class=\"wp-image-7281\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/57e37cbeac654554aea2d041511b0dfc.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/57e37cbeac654554aea2d041511b0dfc-300x157.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/57e37cbeac654554aea2d041511b0dfc-1024x536.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/57e37cbeac654554aea2d041511b0dfc-768x402.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/57e37cbeac654554aea2d041511b0dfc-18x9.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Dans les communications num\u00e9riques modernes, les donn\u00e9es doivent circuler avec pr\u00e9cision entre les appareils, les serveurs, les syst\u00e8mes de stockage et les r\u00e9seaux. Que vous transf\u00e9riez des fichiers, diffusiez des vid\u00e9os, utilisiez des commutateurs Ethernet ou connectiez des liaisons haute vitesse <a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">Modules SFP<\/a> dans un <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/what-is-a-data-center\/\">centre de donn\u00e9es<\/a>, m\u00eame un seul bit corrompu peut provoquer des \u00e9checs de transmission, une perte de paquets ou des donn\u00e9es endommag\u00e9es. C\u2019est ici que <strong>CRC (Contr\u00f4le de redondance cyclique)<\/strong> devient essentiel.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A <strong>v\u00e9rification CRC<\/strong> constitue l\u2019une des m\u00e9thodes de d\u00e9tection d\u2019erreurs les plus r\u00e9pandues dans les r\u00e9seaux et les communications de donn\u00e9es. Elle aide les appareils \u00e0 d\u00e9terminer si les donn\u00e9es transmises ont \u00e9t\u00e9 modifi\u00e9es, corrompues ou endommag\u00e9es pendant le transfert. La technologie CRC est couramment utilis\u00e9e dans les r\u00e9seaux Ethernet, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/what-is-a-router-key-functions-types\/\">routeurs<\/a>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/what-is-a-network-switch\/\">commutateurs<\/a>, les dispositifs de stockage, les syst\u00e8mes de communication industrielle, les fibres optiques et les \u00e9metteurs-r\u00e9cepteurs SFP afin d\u2019assurer l\u2019int\u00e9grit\u00e9 des donn\u00e9es et une communication fiable.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Lorsqu\u2019un syst\u00e8me d\u00e9tecte une incoh\u00e9rence lors de la v\u00e9rification, il g\u00e9n\u00e8re une <strong>erreur CRC<\/strong>. Ces erreurs indiquent souvent des probl\u00e8mes tels que des c\u00e2bles endommag\u00e9s, des interf\u00e9rences \u00e9lectromagn\u00e9tiques, une d\u00e9gradation du signal, des composants mat\u00e9riels d\u00e9fectueux, des modules SFP incompatibles, des connecteurs sales <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/common-fiber-connector-types-optical-transceivers\/\">les connecteurs de fibre<\/a>, ou des liens r\u00e9seau instables. Dans les environnements professionnels, la r\u00e9currence d\u2019erreurs CRC peut r\u00e9duire les performances r\u00e9seau, augmenter le nombre de retransmissions et provoquer des pertes de paquets sur les liaisons haute vitesse.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Comme le CRC est \u00e9troitement li\u00e9 \u00e0 l\u2019infrastructure r\u00e9seau moderne, les utilisateurs recherchent fr\u00e9quemment des questions telles que :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Qu\u2019est-ce que le CRC dans les r\u00e9seaux ?<\/p><\/li><li><p>Que signifie une erreur de contr\u00f4le de redondance cyclique ?<\/p><\/li><li><p>Le CRC est-il meilleur qu\u2019une somme de contr\u00f4le ?<\/p><\/li><li><p>Comment r\u00e9soudre les erreurs CRC sur les liaisons Ethernet ou fibre ?<\/p><\/li><li><p>Pourquoi les modules SFP affichent-ils des erreurs CRC ?<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Comprendre le fonctionnement du CRC est essentiel non seulement pour les ing\u00e9nieurs r\u00e9seaux et les administrateurs informatiques, mais aussi pour les entreprises g\u00e9rant des serveurs, des commutateurs, des \u00e9quipements industriels et des syst\u00e8mes de communication optique. \u00c0 mesure que les d\u00e9bits r\u00e9seau progressent vers 10 G, 25 G, 40 G, 100 G et au-del\u00e0, la d\u00e9tection fiable des erreurs devient encore plus critique pour assurer une transmission stable des donn\u00e9es.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dans ce guide, vous apprendrez :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Ce que signifie r\u00e9ellement CRC (Contr\u00f4le de redondance cyclique)<\/p><\/li><li><p>Comment fonctionnent les v\u00e9rifications CRC dans les r\u00e9seaux et la transmission de donn\u00e9es<\/p><\/li><li><p>La diff\u00e9rence entre les m\u00e9thodes CRC et somme de contr\u00f4le<\/p><\/li><li><p>Causes courantes des erreurs CRC<\/p><\/li><li><p>Comment d\u00e9panner les erreurs CRC dans les r\u00e9seaux Ethernet et fibre<\/p><\/li><li><p>Pourquoi les probl\u00e8mes CRC apparaissent fr\u00e9quemment dans <a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-25832-1-2-4g-transceiver-modules.htm\">\u00e9metteurs-r\u00e9cepteurs optiques<\/a><\/p><\/li><li><p>Bonnes pratiques pour pr\u00e9venir les probl\u00e8mes r\u00e9seau li\u00e9s au CRC<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c0 la fin de cet article, vous aurez une compr\u00e9hension claire de la mani\u00e8re dont le CRC prot\u00e8ge l\u2019int\u00e9grit\u00e9 des donn\u00e9es et pourquoi les erreurs CRC ne doivent jamais \u00eatre ignor\u00e9es dans les environnements r\u00e9seau modernes.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udfe8 Qu\u2019est-ce que le CRC (contr\u00f4le de redondance cyclique) ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le CRC (contr\u00f4le de redondance cyclique) est un code de d\u00e9tection d\u2019erreurs utilis\u00e9 pour v\u00e9rifier si des donn\u00e9es num\u00e9riques ont \u00e9t\u00e9 corrompues pendant la transmission ou le stockage. Il existe parce que les liaisons r\u00e9seau, les dispositifs de stockage et les syst\u00e8mes de communication peuvent \u00eatre affect\u00e9s par du bruit, des interf\u00e9rences, une perte de signal ou des pannes mat\u00e9rielles. Le CRC aide les dispositifs \u00e0 d\u00e9tecter les paquets endommag\u00e9s ou les fichiers corrompus avant qu\u2019ils ne soient accept\u00e9s, ce qui en fait une technologie fondamentale dans les r\u00e9seaux Ethernet, les syst\u00e8mes de stockage et les modules optiques SFP.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9e2332272bd4478899d224c36f0a5c6b.jpg\" alt=\"What Is CRC Cyclic Redundancy Check?\" class=\"wp-image-7282\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9e2332272bd4478899d224c36f0a5c6b.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9e2332272bd4478899d224c36f0a5c6b-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9e2332272bd4478899d224c36f0a5c6b-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9e2332272bd4478899d224c36f0a5c6b-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9e2332272bd4478899d224c36f0a5c6b-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >D\u00e9finition concise : CRC = Code de d\u00e9tection d\u2019erreurs<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le CRC est une m\u00e9thode math\u00e9matique utilis\u00e9e pour v\u00e9rifier si des donn\u00e9es binaires ont chang\u00e9 pendant la transmission.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Son objectif est simple :<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>D\u00e9tecter les donn\u00e9es corrompues avant que le syst\u00e8me ne les utilise.<\/p><\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">Le CRC ne <strong>not<\/strong> r\u00e9pare pas les donn\u00e9es.<br\/>Il d\u00e9tecte uniquement si une erreur s\u2019est produite.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">C\u2019est pourquoi le CRC est largement utilis\u00e9 dans :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>que dans les environnements de centre de donn\u00e9es haute vitesse pour connecter des<\/p><\/li><li><p>Les routeurs et les commutateurs<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/ssd-solid-state-drive-explained\/\">les disques SSD<\/a> and <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/what-is-an-hdd-hard-disk-drive\/\">les disques durs (HDD)<\/a><\/p><\/li><li><p>La communication par fibre optique<\/p><\/li><li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-26155-1g-sfp.htm\">SFP<\/a> and <a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-26153-40g-qsfp.htm\">QSFP<\/a> \u00e9metteurs-r\u00e9cepteurs<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Pourquoi le CRC existe-t-il ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La communication num\u00e9rique n\u2019est jamais totalement exempte d\u2019erreurs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La corruption des donn\u00e9es peut r\u00e9sulter de :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/what-is-electromagnetic-interference\/\">Interf\u00e9rences \u00e9lectromagn\u00e9tiques<\/a> (EMI)<\/p><\/li><li><p>C\u00e2bles endommag\u00e9s<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/attenuation-in-optical-transceiver-management-and-solutions\/\">Affaiblissement du signal<\/a><\/p><\/li><li><p>Connecteurs de fibre optique sales<\/p><\/li><li><p>Modules SFP d\u00e9fectueux<\/p><\/li><li><p>Instabilit\u00e9 mat\u00e9rielle<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Sans CRC, les dispositifs n\u2019auraient aucun moyen fiable d\u2019identifier les paquets de donn\u00e9es corrompus ou les fichiers endommag\u00e9s.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 291px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"291\"><p>Sc\u00e9nario<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>R\u00e9sultat du CRC<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"291\"><p>Trame Ethernet corrompue<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Erreur d\u00e9tect\u00e9e<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"291\"><p>Transmission fibre d\u00e9fectueuse<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Paquet rejet\u00e9<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"291\"><p>Erreur de bit en stockage<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u00c9chec d\u2019int\u00e9grit\u00e9 d\u00e9tect\u00e9<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"291\"><p>Interf\u00e9rences r\u00e9seau<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Donn\u00e9es corrompues identifi\u00e9es<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Pourquoi le CRC est essentiel dans les r\u00e9seaux Ethernet et SFP<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les normes Ethernet modernes, \u00e9labor\u00e9es par l\u2019Institut des ing\u00e9nieurs en \u00e9lectricit\u00e9 et en \u00e9lectronique (IEEE), utilisent des champs de s\u00e9quence de contr\u00f4le de trame (FCS) bas\u00e9s sur le CRC pour d\u00e9tecter les trames corrompues.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dans les r\u00e9seaux haute vitesse tels que :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-26192-10g-sfp.htm\">SFP+ 10 G<\/a><\/p><\/li><li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-26225-25g-sfp28.htm\">SFP28 25 G<\/a><\/p><\/li><li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\">100 G QSFP28<\/a><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Les erreurs CRC indiquent souvent :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Une mauvaise qualit\u00e9 du signal<\/p><\/li><li><p>Des connecteurs optiques sales<\/p><\/li><li><p>Probl\u00e8mes de liaison en fibre<\/p><\/li><li><p>Modules optiques incompatibles<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Les erreurs CRC sont souvent des signes avant-coureurs de probl\u00e8mes r\u00e9seau au niveau de la couche physique.<\/p><\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">Pour les ing\u00e9nieurs r\u00e9seaux, la surveillance des compteurs CRC fait partie int\u00e9grante du maintien de liaisons Ethernet et fibres optiques stables.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udfe8 Comment le CRC d\u00e9tecte-t-il les erreurs de donn\u00e9es ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le CRC d\u00e9tecte les erreurs de donn\u00e9es en g\u00e9n\u00e9rant une valeur de somme de contr\u00f4le math\u00e9matique \u00e0 partir des donn\u00e9es d\u2019origine avant leur transmission. Lorsque les donn\u00e9es atteignent le r\u00e9cepteur, le syst\u00e8me recalcule la valeur CRC et la compare \u00e0 celle d\u2019origine. Si les deux valeurs ne correspondent pas, l\u2019appareil sait que les donn\u00e9es ont \u00e9t\u00e9 corrompues pendant la transmission ou le stockage. Ce processus permet aux commutateurs Ethernet, routeurs, syst\u00e8mes de stockage et liaisons optiques SFP de d\u00e9tecter rapidement et efficacement les paquets endommag\u00e9s.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/00b1a69528084c57b03c7838bbfb952b.jpg\" alt=\"How Does CRC Detect Data Errors?\" class=\"wp-image-7283\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/00b1a69528084c57b03c7838bbfb952b.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/00b1a69528084c57b03c7838bbfb952b-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/00b1a69528084c57b03c7838bbfb952b-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/00b1a69528084c57b03c7838bbfb952b-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/00b1a69528084c57b03c7838bbfb952b-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Processus de d\u00e9tection des erreurs CRC en 3 \u00e9tapes<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le CRC fonctionne via un processus de v\u00e9rification simple :<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 141px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"141\"><p>Step<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Ce qui se produit<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Objectif<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"141\"><p>\u00c9tape 1<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>L\u2019\u00e9metteur calcule une valeur CRC \u00e0 partir des donn\u00e9es d\u2019origine<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Cr\u00e9e une v\u00e9rification d\u2019int\u00e9grit\u00e9 unique<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"141\"><p>\u00c9tape 2<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Le r\u00e9cepteur recalcule la valeur CRC \u00e0 l\u2019aide des donn\u00e9es re\u00e7ues<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>V\u00e9rifie la coh\u00e9rence des donn\u00e9es<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"141\"><p>\u00c9tape 3<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Le syst\u00e8me compare les deux valeurs CRC<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>D\u00e9tecte les erreurs de transmission<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Si les valeurs CRC correspondent : les donn\u00e9es sont consid\u00e9r\u00e9es comme valides.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Si les valeurs CRC ne correspondent pas :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Le syst\u00e8me d\u00e9tecte une corruption.<\/p><\/li><li><p>Le paquet ou le fichier peut \u00eatre rejet\u00e9 ou retransmis.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Exemple simple du fonctionnement du CRC<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Imaginez qu\u2019un commutateur envoie une trame Ethernet via une liaison en fibre optique utilisant un module SFP.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >Avant la transmission<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Le commutateur :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>G\u00e9n\u00e8re le paquet de donn\u00e9es<\/p><\/li><li><p>Calcule la valeur CRC<\/p><\/li><li><p>Ajoute la valeur CRC \u00e0 la trame Ethernet<\/p><\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\" >Pendant la transmission<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Le signal peut \u00eatre affect\u00e9 par :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Interf\u00e9rences \u00e9lectromagn\u00e9tiques (EMI)<\/p><\/li><li><p>Une perte de signal optique<\/p><\/li><li><p>Connecteurs de fibre optique sales<\/p><\/li><li><p>Des c\u00e2bles DAC\/AOC d\u00e9fectueux<\/p><\/li><li><p>Modules SFP incompatibles<\/p><\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\" >Apr\u00e8s la r\u00e9ception<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019appareil r\u00e9cepteur :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Recalcule la valeur CRC<\/p><\/li><li><p>La compare \u00e0 la valeur CRC d\u2019origine<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">M\u00eame si un seul bit binaire change pendant la transmission, les valeurs CRC deviennent diff\u00e9rentes et la trame est marqu\u00e9e comme corrompue. Le CRC est con\u00e7u pour d\u00e9tecter la corruption accidentelle des donn\u00e9es, pas pour chiffrer ou r\u00e9parer les donn\u00e9es.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Pourquoi le CRC est efficace dans les r\u00e9seaux Ethernet<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les normes Ethernet modernes de l\u2019Institut des ing\u00e9nieurs \u00e9lectriciens et \u00e9lectroniciens (IEEE) utilisent des champs de s\u00e9quence de contr\u00f4le d\u2019erreur bas\u00e9s sur le CRC (Frame Check Sequence, FCS) pour v\u00e9rifier l\u2019int\u00e9grit\u00e9 des trames de couche 2.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le CRC est tr\u00e8s efficace car il permet de d\u00e9tecter :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Les erreurs simples sur un seul bit<\/p><\/li><li><p>Erreurs par rafale<\/p><\/li><li><p>La corruption li\u00e9e au bruit<\/p><\/li><li><p>L\u2019instabilit\u00e9 de la transmission<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Dans les environnements Ethernet haute vitesse (10 G, 25 G et 100 G), la v\u00e9rification CRC est essentielle pour assurer une livraison fiable des paquets et des performances r\u00e9seau stables.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udfe8 Pourquoi les erreurs CRC se produisent-elles ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Les erreurs CRC ne signifient g\u00e9n\u00e9ralement pas que le syst\u00e8me CRC lui-m\u00eame est d\u00e9fectueux. Dans la plupart des cas, une erreur CRC indique que les donn\u00e9es ont \u00e9t\u00e9 corrompues pendant la transmission en raison d\u2019un probl\u00e8me au niveau de la couche physique. Les causes courantes incluent des c\u00e2bles endommag\u00e9s, des connecteurs fibre optique souill\u00e9s, des interf\u00e9rences \u00e9lectromagn\u00e9tiques (EMI), une att\u00e9nuation du signal, des ports de commutateur d\u00e9fectueux ou des modules optiques SFP incompatibles. Dans les r\u00e9seaux Ethernet, la r\u00e9currence des erreurs CRC constitue souvent un signe pr\u00e9coce d\u2019instabilit\u00e9 de la liaison ou de d\u00e9gradation mat\u00e9rielle.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Les erreurs CRC sont typiquement des sympt\u00f4mes de probl\u00e8mes de transmission \u2014 et non de probl\u00e8mes logiciels.<\/p><\/blockquote>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/713d4f38d36e445695765d7e0d25f405.jpg\" alt=\"Why Do CRC Errors Happen?\" class=\"wp-image-7284\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/713d4f38d36e445695765d7e0d25f405.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/713d4f38d36e445695765d7e0d25f405-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/713d4f38d36e445695765d7e0d25f405-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/713d4f38d36e445695765d7e0d25f405-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/713d4f38d36e445695765d7e0d25f405-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Causes des erreurs CRC et leur impact<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les erreurs CRC surviennent lorsque les donn\u00e9es re\u00e7ues ne correspondent pas aux donn\u00e9es initialement transmises.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Probl\u00e8me physique<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Comment cela provoque-t-il des erreurs CRC<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Environnement courant<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Connecteur de fibre sale<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Affaiblit la qualit\u00e9 du signal optique<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Centres de donn\u00e9es<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>C\u00e2ble cuivre endommag\u00e9<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Introduit une corruption de paquets<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Ethernet bureautique<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Interf\u00e9rences \u00e9lectromagn\u00e9tiques (EMI)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Perturbe la transmission \u00e9lectrique<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Usines industrielles<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Module SFP incompatible<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Provoque une n\u00e9gociation de liaison instable<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Commutateurs d\u2019entreprise<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Distance de transmission excessive<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Augmente le taux d\u2019erreurs par bit (BER)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Liaisons fibre longues<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Port de commutateur d\u00e9fectueux<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Corrompt les trames Ethernet<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Mat\u00e9riel vieillissant<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Pourquoi les erreurs CRC sont-elles fr\u00e9quentes dans les r\u00e9seaux SFP ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Dans les environnements Ethernet \u00e0 fibre optique, les erreurs CRC sont fr\u00e9quemment li\u00e9es \u00e0 des probl\u00e8mes au niveau de la couche optique.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Par exemple :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Des connecteurs LC contamin\u00e9s peuvent augmenter la perte d\u2019insertion<\/p><\/li><li><p>Des \u00e9metteurs-r\u00e9cepteurs de mauvaise qualit\u00e9 peuvent g\u00e9n\u00e9rer des signaux optiques instables<\/p><\/li><li><p>Inad\u00e9quation <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/sfp-wavelengths-850nm-1310nm-1550nm-guide\/\">longueurs d\u2019onde<\/a> peut r\u00e9duire la fiabilit\u00e9 de la transmission<\/p><\/li><li><p>Un pliage excessif de la fibre peut alt\u00e9rer l\u2019int\u00e9grit\u00e9 du signal<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ceci est particuli\u00e8rement important dans :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>SFP+ 10 G<\/p><\/li><li><p>SFP28 25 G<\/p><\/li><li><p>100 G QSFP28<\/p><\/li><li><p>r\u00e9seaux spine-leaf de centre de donn\u00e9es<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c0 mesure que les d\u00e9bits Ethernet augmentent, les marges de tol\u00e9rance du signal se r\u00e9duisent, rendant la surveillance CRC encore plus critique pour la fiabilit\u00e9 du r\u00e9seau.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Erreurs CRC par rapport \u00e0 la perte de paquets<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">De nombreux utilisateurs confondent les erreurs CRC avec la perte de paquets.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>D\u00e9finition microscopique<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Erreur CRC :<\/strong> L\u2019appareil a re\u00e7u des donn\u00e9es corrompues.<\/p><\/li><li><p><a target=\"_self\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/what-does-packet-loss-mean-for-your-internet-connection\/\"><strong>Perte de paquets<\/strong><\/a><strong>:<\/strong> Le paquet n\u2019est jamais arriv\u00e9 avec succ\u00e8s.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Les erreurs CRC surviennent souvent avant que la perte de paquets ne devienne visible.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">C\u2019est pourquoi les ing\u00e9nieurs r\u00e9seau surveillent les compteurs CRC comme indicateur pr\u00e9coce d\u2019alerte de :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Instabilit\u00e9 de la couche physique<\/p><\/li><li><p>D\u00e9gradation optique<br><\/p><\/li><li><p>Pannes de c\u00e2ble<\/p><\/li><li><p>Probl\u00e8mes de transmission au niveau du port<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Dans les environnements entreprise, une augmentation des comptes d\u2019erreurs CRC sur les interfaces de commutateur n\u00e9cessite g\u00e9n\u00e9ralement une investigation imm\u00e9diate, avant que le probl\u00e8me n\u2019affecte les performances applicatives ou la disponibilit\u00e9 du service.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udfe8 Que signifient les erreurs CRC sur les r\u00e9seaux Ethernet et les modules SFP ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Sur les r\u00e9seaux Ethernet et optiques SFP, les erreurs CRC signifient g\u00e9n\u00e9ralement que des paquets de donn\u00e9es ont \u00e9t\u00e9 corrompus pendant la transmission. La cause premi\u00e8re la plus courante est une mauvaise qualit\u00e9 du signal au niveau de la couche physique, plut\u00f4t qu\u2019une d\u00e9faillance logicielle. Des probl\u00e8mes tels que des connecteurs de fibre sales, des c\u00e2bles endommag\u00e9s, des ports de commutateur instables, une att\u00e9nuation du signal ou des modules SFP\/SFP+ incompatibles et <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/473115.htm\">Modules QSFP28<\/a> peuvent tous g\u00e9n\u00e9rer des erreurs de trame CRC sur les liens Ethernet.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dans la plupart des r\u00e9seaux entreprise, les erreurs CRC sont des signaux d\u2019alerte au niveau de la couche physique.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/576969458fd94a4ebafdb65aa8003cdd.jpg\" alt=\"What Do CRC Errors Mean on Ethernet and SFP Modules?\" class=\"wp-image-7285\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/576969458fd94a4ebafdb65aa8003cdd.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/576969458fd94a4ebafdb65aa8003cdd-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/576969458fd94a4ebafdb65aa8003cdd-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/576969458fd94a4ebafdb65aa8003cdd-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/576969458fd94a4ebafdb65aa8003cdd-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Pourquoi les erreurs CRC sont-elles importantes dans les r\u00e9seaux Ethernet<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les r\u00e9seaux Ethernet modernes s\u2019appuient sur la v\u00e9rification bas\u00e9e sur le CRC de la s\u00e9quence de contr\u00f4le de trame (FCS) pour valider l\u2019int\u00e9grit\u00e9 des paquets au niveau de la couche 2.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Lorsqu\u2019un commutateur, un routeur ou <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/what-is-nic-network-interface-card\/\">NIC<\/a> re\u00e7oit une trame avec une valeur CRC invalide :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>La trame est consid\u00e9r\u00e9e comme corrompue<\/p><\/li><li><p>Le paquet est rejet\u00e9<\/p><\/li><li><p>Des retransmissions peuvent se produire<\/p><\/li><li><p>Les performances du r\u00e9seau peuvent se d\u00e9grader<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">C\u2019est pourquoi les compteurs CRC sont couramment surveill\u00e9s sur :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Les ports de commutateur<\/p><\/li><li><p>Les liaisons montantes SFP\/SFP+<\/p><\/li><li><p>Les liaisons de centre de donn\u00e9es QSFP28<\/p><\/li><li><p>Les commutateurs d\u2019agr\u00e9gation en fibre<\/p><\/li><li><p>L\u2019infrastructure Ethernet c\u0153ur<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Dans les environnements Ethernet haute vitesse (10 G, 25 G, 40 G et 100 G), la r\u00e9currence d\u2019erreurs CRC indique g\u00e9n\u00e9ralement une transmission de signal instable quelque part dans le lien.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Sc\u00e9narios courants d\u2019erreurs CRC sur les liens SFP et Ethernet<\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Appareil \/ Sc\u00e9nario<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Sympt\u00f4mes courants<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Causes possibles<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Premi\u00e8re chose \u00e0 v\u00e9rifier<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Liaison montante en fibre SFP+<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Augmentation des compteurs CRC<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Connecteur LC sale<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Nettoyage des extr\u00e9mit\u00e9s des fibres<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Liaison QSFP28 100 G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Pertes de paquets<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Perte optique excessive<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>V\u00e9rification des niveaux de puissance optique<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Port de commutateur Ethernet<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Erreurs de trame<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Mat\u00e9riel de port d\u00e9fectueux<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>D\u00e9placez le c\u00e2ble vers un autre port<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/direct-attach-cables-dac-in-networking\/\">le c\u00e2ble DAC<\/a> connexion<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Pics intermittents de CRC<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>C\u00e2ble DAC de mauvaise qualit\u00e9<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Remplacez le c\u00e2ble DAC<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Liaison fibre longue distance<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>CRC + retransmissions<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Affaiblissement du signal<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>V\u00e9rifiez la distance de transmission<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Optiques de fournisseurs mixtes<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Une instabilit\u00e9 de la liaison<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/how-to-test-sfp-compatibility\/\">Compatibilit\u00e9 SFP<\/a> probl\u00e8me<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Testez les modules certifi\u00e9s<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Erreurs CRC sur les ports commutateurs<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Sur les commutateurs Ethernet g\u00e9r\u00e9s, les erreurs CRC sont g\u00e9n\u00e9ralement visibles dans :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>les statistiques d\u2019interface<\/p><\/li><li><p>les tableaux de bord de surveillance des ports<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/simple-network-management-protocol-snmp-network-monitoring\/\">SNMP<\/a> les compteurs<\/p><\/li><li><p>les commandes de diagnostic CLI<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Par exemple :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Les commutateurs Cisco peuvent afficher \u201c erreurs d\u2019entr\u00e9e \u201d et \u201c CRC \u201d<\/p><\/li><li><p>Les \u00e9quipements Juniper peuvent afficher des erreurs FCS Ethernet<\/p><\/li><li><p>Les commutateurs MikroTik et HPE suivent les \u00e9checs de v\u00e9rification de trame<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Si les compteurs CRC continuent d\u2019augmenter au fil du temps, les ing\u00e9nieurs r\u00e9seau enqu\u00eatent g\u00e9n\u00e9ralement sur :<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>Propret\u00e9 de la fibre<\/p><\/li><li><p>l\u2019int\u00e9grit\u00e9 du c\u00e2ble<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/478230.htm\">le module optique<\/a> compatibilit\u00e9<\/p><\/li><li><p>l\u2019\u00e9tat du port commutateur<\/p><\/li><li><p>les sources d\u2019interf\u00e9rences \u00e9lectromagn\u00e9tiques (EMI)<\/p><\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" >Pourquoi les modules SFP d\u00e9clenchent fr\u00e9quemment des erreurs CRC<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">SFP et <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/482749.htm\">les transceivers QSFP<\/a> fonctionnent \u00e0 des d\u00e9bits de signalisation tr\u00e8s \u00e9lev\u00e9s.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Par exemple :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>SFP+ 10 G = d\u00e9bit ligne de 10,3125 Gbps<\/p><\/li><li><p>SFP28 25 G = 25,78125 Gbps<\/p><\/li><li><p>QSFP28 100 G utilise 4 voies \u00e9lectriques<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c0 ces d\u00e9bits, m\u00eame de petits probl\u00e8mes au niveau de la couche physique peuvent corrompre les paquets.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les causes courantes d\u2019erreurs CRC li\u00e9es aux SFP incluent :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>mauvais alignement optique<\/p><\/li><li><p>connecteurs fibre sales<\/p><\/li><li><p>Perte d\u2019insertion excessive<\/p><\/li><li><p>transceivers en surchauffe<\/p><\/li><li><p>modules optiques non pris en charge<\/p><\/li><li><p>optiques tierces de mauvaise qualit\u00e9<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">C\u2019est pourquoi les centres de donn\u00e9es et les r\u00e9seaux t\u00e9l\u00e9com utilisent souvent :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/ddm-dom-in-optical-transceivers\/\">DOM\/DDM<\/a> la surveillance optique<\/p><\/li><li><p>le suivi des compteurs CRC<\/p><\/li><li><p>l\u2019analyse du taux d\u2019erreur binaire (BER)<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/understanding-what-is-bit-error-rate\/\">Taux d\u2019erreur binaire<\/a>)<\/p><\/li><li><p>les diagnostics de puissance optique<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">pour identifier de fa\u00e7on proactive les liaisons d\u00e9faillantes avant qu\u2019une panne ne survienne.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Les erreurs CRC sont souvent des indicateurs pr\u00e9coces d\u2019une d\u00e9faillance de liaison<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les erreurs CRC n\u2019apparaissent que rarement isol\u00e9ment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dans les d\u00e9ploiements r\u00e9els, elles sont souvent suivies de :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>retransmissions de paquets<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/what-is-throughput-in-network-communication-explained\/\">D\u00e9bit<\/a> r\u00e9duction<\/p><\/li><li><p>pics de latence<\/p><\/li><li><p>basculement d\u2019interface<\/p><\/li><li><p>instabilit\u00e9 applicative<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Pour cette raison, les ing\u00e9nieurs r\u00e9seau exp\u00e9riment\u00e9s consid\u00e8rent les erreurs CRC r\u00e9currentes comme un avertissement pr\u00e9coce concernant l\u2019infrastructure, plut\u00f4t que comme une simple anomalie statistique mineure. Une augmentation du compteur CRC signifie g\u00e9n\u00e9ralement que la qualit\u00e9 de la liaison Ethernet se d\u00e9grade.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udfe8 Comment d\u00e9panner les erreurs CRC pas \u00e0 pas<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La m\u00e9thode la plus rapide pour diagnostiquer les erreurs CRC consiste \u00e0 analyser d\u2019abord la couche physique. Dans la plupart des r\u00e9seaux Ethernet et SFP, les erreurs CRC sont caus\u00e9es par des probl\u00e8mes de c\u00e2blage, des connecteurs optiques sales, des modules optiques incompatibles, une att\u00e9nuation du signal ou des ports de commutateur d\u00e9fectueux. Une proc\u00e9dure structur\u00e9e de d\u00e9pannage aide les ing\u00e9nieurs r\u00e9seau \u00e0 isoler rapidement la cause racine avant que la perte de paquets, les retransmissions ou l\u2019instabilit\u00e9 de la liaison n\u2019affectent le trafic de production.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/abb042b8e2724eb6bbbbcf2e62982445.jpg\" alt=\"How to Troubleshoot CRC Errors Step by Step\" class=\"wp-image-7286\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/abb042b8e2724eb6bbbbcf2e62982445.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/abb042b8e2724eb6bbbbcf2e62982445-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/abb042b8e2724eb6bbbbcf2e62982445-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/abb042b8e2724eb6bbbbcf2e62982445-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/abb042b8e2724eb6bbbbcf2e62982445-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Commencez par les v\u00e9rifications physiques les plus simples avant de remplacer du mat\u00e9riel.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00c9tape 1 : V\u00e9rifiez les c\u00e2bles et les connexions physiques<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les probl\u00e8mes de c\u00e2blage physique constituent l\u2019une des causes les plus fr\u00e9quentes d\u2019erreurs CRC.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Inspectez :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Les c\u00e2bles de raccordement Ethernet<\/p><\/li><li><p>Les c\u00e2bles de raccordement en fibre optique<\/p><\/li><li><p>DAC\/<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/aoc-explained-active-optical-cable-benefits-uses-advancements-guide\/\">c\u00e2bles AOC<\/a><\/p><\/li><li><p>L\u2019alignement des connecteurs LC<\/p><\/li><li><p>Le rayon de courbure du c\u00e2ble<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Sympt\u00f4mes courants :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Pics intermittents de CRC<\/p><\/li><li><p>retransmissions de paquets<\/p><\/li><li><p>Clignotement de liaison<\/p><\/li><li><p>D\u00e9bit r\u00e9duit<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Dans les r\u00e9seaux en fibre optique, m\u00eame une contamination microscopique par la poussi\u00e8re peut accro\u00eetre la perte d\u2019insertion et d\u00e9grader la qualit\u00e9 du signal optique.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00c9tape 2 : V\u00e9rifiez la compatibilit\u00e9 des modules SFP ou QSFP<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Dans les commutateurs d\u2019entreprise, des composants optiques incompatibles g\u00e9n\u00e8rent fr\u00e9quemment des erreurs CRC et FCS.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">V\u00e9rifier :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Compatibilit\u00e9 des fournisseurs<\/p><\/li><li><p>Longueur d\u2019onde de transmission<\/p><\/li><li><p>Type de fibre (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/ieee-802-3-ethernet-standard-explained\/\">Fibre monomode (SMF)\/fibre multimode (MMF)<\/a>)<\/p><\/li><li><p>Diagnostics DOM\/DDM<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/optical-transceivers-operating-temperature-range\/\">Temp\u00e9rature de fonctionnement<\/a><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Par exemple :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/473141.htm\">10GBASE-SR<\/a> n\u00e9cessite une fibre multimode<\/p><\/li><li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/476046.htm\">10GBASE-LR<\/a> n\u00e9cessite une fibre monomode<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019utilisation de composants optiques non appari\u00e9s peut cr\u00e9er des liaisons Ethernet instables, m\u00eame si l\u2019interface semble \u201c activ\u00e9e \u201d.\u201d<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00c9tape 3 : Surveillez les compteurs CRC sur les ports du commutateur<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les commutateurs g\u00e9r\u00e9s suivent en continu :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Erreurs CRC<\/p><\/li><li><p>Erreurs FCS<\/p><\/li><li><p>Erreurs d\u2019entr\u00e9e<\/p><\/li><li><p>Les pertes d\u2019interface<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Si les compteurs CRC augmentent dans le temps :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Comparez les deux extr\u00e9mit\u00e9s de la liaison<\/p><\/li><li><p>D\u00e9placez le c\u00e2ble vers un autre port<\/p><\/li><li><p>Testez avec un autre \u00e9metteur-r\u00e9cepteur<\/p><\/li><li><p>V\u00e9rifiez si les erreurs suivent le c\u00e2ble ou le port<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>D\u00e9finition microscopique<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Compteur CRC :<\/strong> Le nombre de trames corrompues d\u00e9tect\u00e9es sur une interface.<\/p><\/li><li><p><strong>Erreur FCS :<\/strong> Trame Ethernet ayant \u00e9chou\u00e9 \u00e0 la validation CRC.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00c9tape 4 : V\u00e9rifiez la perte optique et la distance de transmission<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019att\u00e9nuation du signal devient plus critique dans :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>SFP28 25 G<\/p><\/li><li><p>100 G QSFP28<\/p><\/li><li><p>Liaisons fibre longue distance<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Une perte d\u2019insertion excessive peut augmenter le taux d\u2019erreurs binaire (BER), provoquant finalement une corruption de trames CRC.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">V\u00e9rifiez&nbsp;:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Niveaux de puissance optique<\/p><\/li><li><p>Longueur de la fibre<\/p><\/li><li><p>La perte au niveau des connecteurs<\/p><\/li><li><p>Qualit\u00e9 du panneau de brassage<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Dans les environnements Ethernet haute vitesse, m\u00eame une l\u00e9g\u00e8re r\u00e9duction de la marge optique peut d\u00e9clencher des erreurs CRC r\u00e9currentes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00c9tape 5 : Consultez les journaux du commutateur et les alarmes d\u2019interface<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les commutateurs d'entreprise de soci\u00e9t\u00e9s telles que Cisco, Juniper Networks et Arista Networks fournissent des diagnostics d\u00e9taill\u00e9s des interfaces.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Examen :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u00c9v\u00e9nements de r\u00e9initialisation des interfaces<\/p><\/li><li><p>Avertissements d\u2019instabilit\u00e9 de la liaison<\/p><\/li><li><p>Alarmes DOM<\/p><\/li><li><p>Alertes de temp\u00e9rature<\/p><\/li><li><p>Statistiques de pertes de paquets<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Des alarmes CRC r\u00e9currentes combin\u00e9es \u00e0 une augmentation des erreurs d\u2019interface indiquent g\u00e9n\u00e9ralement une d\u00e9gradation de la liaison physique.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Connaissance pratique en ing\u00e9nierie<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Dans les d\u00e9ploiements pratiques de centres de donn\u00e9es, le d\u00e9pannage des erreurs CRC suit souvent un principe d\u2019ing\u00e9nierie simple :<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Si les erreurs CRC se d\u00e9placent avec le c\u00e2ble ou le transceiver, le probl\u00e8me provient g\u00e9n\u00e9ralement de l\u2019ext\u00e9rieur du commutateur. <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/what-is-application-specific-integrated-circuit-asic\/\">ASIC<\/a>.<\/p><\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">De nombreuses \u00e9quipes r\u00e9seau r\u00e9solvent les probl\u00e8mes persistants d\u2019erreurs CRC en :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Rempla\u00e7ant les c\u00e2bles DAC de faible qualit\u00e9<\/p><\/li><li><p>Nettoyant les connecteurs de fibre optique<\/p><\/li><li><p>Normalisant les modules SFP certifi\u00e9s<\/p><\/li><li><p>R\u00e9duisant l\u2019utilisation d\u2019optiques multi-fournisseurs non prises en charge<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Dans les environnements haute densit\u00e9 25 G et 100 G, une maintenance optique proactive peut r\u00e9duire consid\u00e9rablement les interruptions et les \u00e9v\u00e9nements de retransmission li\u00e9s aux erreurs CRC.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udfe8 Comment pr\u00e9venir les erreurs CRC dans les r\u00e9seaux haute vitesse<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La meilleure fa\u00e7on de pr\u00e9venir les erreurs CRC consiste \u00e0 maintenir une qualit\u00e9 stable du signal au niveau de la couche physique sur l\u2019ensemble de la liaison Ethernet. Dans les r\u00e9seaux haute vitesse 10 G, 25 G, 100 G et 400 G, les probl\u00e8mes CRC sont couramment \u00e9vit\u00e9s gr\u00e2ce \u00e0 l\u2019utilisation de modules SFP\/QSFP compatibles, au nettoyage r\u00e9gulier des connecteurs de fibre, au contr\u00f4le des pertes optiques, \u00e0 la surveillance des compteurs CRC des interfaces, ainsi qu\u2019\u00e0 la normalisation des c\u00e2blages et des d\u00e9ploiements de transceivers. Une maintenance pr\u00e9ventive est bien plus efficace que le d\u00e9pannage r\u00e9p\u00e9t\u00e9 de la corruption de paquets apr\u00e8s l\u2019apparition de pannes.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3fef055439ef45a789f090869021f42b.jpg\" alt=\"How to Prevent CRC Errors in High-Speed Networks\" class=\"wp-image-7287\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3fef055439ef45a789f090869021f42b.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3fef055439ef45a789f090869021f42b-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3fef055439ef45a789f090869021f42b-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3fef055439ef45a789f090869021f42b-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3fef055439ef45a789f090869021f42b-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">La plupart des erreurs CRC r\u00e9currentes peuvent \u00eatre \u00e9vit\u00e9es gr\u00e2ce \u00e0 des pratiques ad\u00e9quates en mati\u00e8re d\u2019optique et de c\u00e2blage.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Utiliser des modules optiques et des c\u00e2blages compatibles<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019une des causes les plus fr\u00e9quentes d\u2019erreurs CRC est l\u2019utilisation de mat\u00e9riel optique inadapt\u00e9 ou de mauvaise qualit\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">V\u00e9rifiez toujours :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Compatibilit\u00e9 SFP\/SFP+<\/p><\/li><li><p>Type de fibre (fibres monomodes ou multimodes)<\/p><\/li><li><p>Ad\u00e9quation des longueurs d\u2019onde<\/p><\/li><li><p>Type de connecteur<\/p><\/li><li><p>Prise en charge de la norme Ethernet<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Par exemple :<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 218px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"218\"><p>Norme optique<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Type de fibre<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Distance typique<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"218\"><p>10GBASE-SR<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibre multimode (MMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Jusqu\u2019\u00e0 300 m<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"218\"><p>10GBASE-LR<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibre monomode (SMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Jusqu\u2019\u00e0 10 km<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"218\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/473141.htm\">25GBASE-SR<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>FMM<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Jusqu\u2019\u00e0 100 m<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"218\"><p>100G <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/488423.htm\">QSFP28 LR4<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SMF<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Jusqu\u2019\u00e0 10 km<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019utilisation d\u2019optiques non prises en charge ou de types de fibres incorrects peut provoquer des erreurs CRC et FCS intermittentes, m\u00eame lorsque la liaison reste op\u00e9rationnelle.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Maintenir les extr\u00e9mit\u00e9s des fibres propres<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les connecteurs optiques sales constituent l\u2019une des principales causes d\u2019erreurs CRC dans les centres de donn\u00e9es.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La contamination peut inclure&nbsp;:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Particules de poussi\u00e8re<\/p><\/li><li><p>Les huiles provenant des doigts<\/p><\/li><li><p>Les r\u00e9sidus de nettoyage<\/p><\/li><li><p>Les d\u00e9bris en suspension dans l\u2019air<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">M\u00eame une contamination microscopique peut&nbsp;:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Augmenter les pertes d\u2019insertion<\/p><\/li><li><p>R\u00e9duire la qualit\u00e9 du signal optique<\/p><\/li><li><p>Augmenter le taux d\u2019erreurs binaire (BER)<\/p><\/li><li><p>Provoquer une corruption de trame CRC<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Bonne pratique<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Inspectez et nettoyez&nbsp;:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>avec prudence. Utilisez toujours des connecteurs LC propres et assurez-vous que les faces des fibres sont minutieusement nettoy\u00e9es avec les bons outils (nettoyeurs \u00e0 cliquet, essuie-mains sans poils, scope d'inspection) avant l'insertion.<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/understanding-polarity-in-mtp-mpo-system-for-signal-integrity\/\">MPO\/MTP<\/a> interfaces<\/p><\/li><li><p>Les panneaux de brassage<\/p><\/li><li><p>Les c\u00e2bles de raccordement en fibre optique<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">avant l\u2019installation et pendant les cycles de maintenance.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Surveillez les compteurs CRC avant l\u2019apparition de pannes<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les \u00e9quipes r\u00e9seau exp\u00e9riment\u00e9es n\u2019attendent pas l\u2019occurrence de pannes pour consulter les statistiques CRC.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les commutateurs modernes de Cisco, Juniper Networks et Arista Networks prennent en charge une surveillance continue des interfaces pour&nbsp;:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Erreurs CRC<\/p><\/li><li><p>Erreurs FCS<\/p><\/li><li><p>Pertes de paquets<\/p><\/li><li><p>Les tendances du BER<\/p><\/li><li><p>Les m\u00e9triques DOM optiques<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>D\u00e9finition microscopique<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Compteur CRC :<\/strong> Suit le nombre de trames Ethernet corrompues d\u00e9tect\u00e9es sur une interface.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Une augmentation progressive du compteur CRC indique souvent&nbsp;:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Une d\u00e9gradation optique pr\u00e9coce<\/p><\/li><li><p>Le vieillissement du c\u00e2ble<\/p><\/li><li><p>Une instabilit\u00e9 du port<\/p><\/li><li><p>Des marges de signal faibles<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">D\u00e9tecter ces tendances t\u00f4t permet d\u2019\u00e9viter des pannes r\u00e9seau \u00e0 grande \u00e9chelle.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Ma\u00eetrisez les pertes optiques et le budget de liaison<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les liaisons Ethernet haute vitesse imposent des exigences strictes en mati\u00e8re de puissance optique.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour une transmission stable&nbsp;:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Les pertes totales d\u2019insertion doivent rester dans les sp\u00e9cifications<\/p><\/li><li><p>Les courbures de la fibre doivent \u00eatre minimis\u00e9es<\/p><\/li><li><p>Les pertes au niveau des panneaux de brassage doivent \u00eatre ma\u00eetris\u00e9es<\/p><\/li><li><p>Les r\u00e9flexions aux connecteurs doivent \u00eatre r\u00e9duites<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Dans les environnements Ethernet 25G et 100G, de faibles pertes de marge optique peuvent augmenter consid\u00e9rablement les erreurs CRC.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Normalisez l\u2019infrastructure sur l\u2019ensemble du r\u00e9seau<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les d\u00e9ploiements multi-fournisseurs peuvent parfois cr\u00e9er des probl\u00e8mes d\u2019interop\u00e9rabilit\u00e9 qui aggravent l\u2019instabilit\u00e9 CRC.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">De nombreux op\u00e9rateurs d\u2019entreprise r\u00e9duisent les probl\u00e8mes li\u00e9s au CRC en normalisant&nbsp;:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Fournisseurs SFP<\/p><\/li><li><p>Les types de c\u00e2bles DAC<\/p><\/li><li><p>L\u2019infrastructure en fibre<\/p><\/li><li><p>Les versions du micrologiciel des commutateurs<\/p><\/li><li><p>Les politiques de surveillance optique<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Dans les grappes d\u2019intelligence artificielle \u00e0 forte densit\u00e9, les centres de donn\u00e9es cloud et les environnements t\u00e9l\u00e9coms, la pr\u00e9vention proactive des erreurs CRC est consid\u00e9r\u00e9e comme faisant partie de l\u2019ing\u00e9nierie de la fiabilit\u00e9 r\u00e9seau \u00e0 long terme, et non simplement d\u2019un d\u00e9pannage ponctuel.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udfe8 FAQ sur les erreurs CRC<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0206ba3ba89843bc8c16058db0a4e13b.jpg\" alt=\"FAQ About CRC Errors\" class=\"wp-image-7288\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0206ba3ba89843bc8c16058db0a4e13b.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0206ba3ba89843bc8c16058db0a4e13b-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0206ba3ba89843bc8c16058db0a4e13b-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0206ba3ba89843bc8c16058db0a4e13b-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0206ba3ba89843bc8c16058db0a4e13b-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Q1&nbsp;: Pourquoi vois-je soudainement des erreurs CRC sur mon port de commutateur&nbsp;?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les erreurs CRC signifient g\u00e9n\u00e9ralement que le commutateur re\u00e7oit des trames Ethernet corrompues. Dans la plupart des cas, le probl\u00e8me est li\u00e9 \u00e0 la couche physique, par exemple des connecteurs de fibre optique sales, des c\u00e2bles endommag\u00e9s, des modules SFP instables ou une att\u00e9nuation du signal.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dans les r\u00e9seaux d\u2019entreprise, l\u2019augmentation des compteurs CRC constitue souvent un signe pr\u00e9coce de d\u00e9gradation de la liaison, avant que la perte de paquets ne devienne visible.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Une erreur CRC indique g\u00e9n\u00e9ralement un probl\u00e8me de transmission, et non un probl\u00e8me logiciel.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Q2 : Le CRC est-il meilleur que la somme de contr\u00f4le pour d\u00e9tecter les erreurs r\u00e9seau ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Oui. Le CRC est plus fiable qu\u2019une somme de contr\u00f4le traditionnelle, car il permet de d\u00e9tecter des motifs de corruption de transmission plus complexes, notamment les erreurs en rafale fr\u00e9quemment observ\u00e9es dans les r\u00e9seaux Ethernet et optiques.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Technologie<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Capacit\u00e9 de d\u00e9tection<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Utilisation courante<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Somme de contr\u00f4le<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Basique<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fichiers, protocoles simples<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>CRC<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Avanc\u00e9<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>R\u00e9seaux Ethernet, SFP<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>ECC<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>D\u00e9tection + correction<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>M\u00e9moire, stockage<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">C\u2019est pourquoi les normes Ethernet modernes utilisent une validation de s\u00e9quence de contr\u00f4le de trame (FCS) bas\u00e9e sur le CRC.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Q3 : Des modules SFP d\u00e9fectueux peuvent-ils provoquer des erreurs CRC ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Oui. Des modules SFP\/SFP+ instables ou incompatibles sont des causes fr\u00e9quentes d\u2019erreurs CRC dans les r\u00e9seaux en fibre optique.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les causes typiques incluent :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Connecteurs LC sales<\/p><\/li><li><p>Une mauvaise qualit\u00e9 du signal optique<\/p><\/li><li><p>Des optiques non prises en charge<\/p><\/li><li><p>Des c\u00e2bles DAC de faible qualit\u00e9<\/p><\/li><li><p>transceivers en surchauffe<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Aux d\u00e9bits 10 G, 25 G et 100 G Ethernet, m\u00eame de l\u00e9gers probl\u00e8mes de qualit\u00e9 du signal peuvent corrompre des paquets.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Q4 : Pourquoi les erreurs CRC surviennent-elles plus fr\u00e9quemment dans les r\u00e9seaux 25 G et 100 G ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les liaisons Ethernet \u00e0 haut d\u00e9bit pr\u00e9sentent des marges de tol\u00e9rance du signal nettement plus faibles.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dans les environnements SFP28 \u00e0 25 G et QSFP28 \u00e0 100 G, la moindre perte optique, la contamination des connecteurs ou la perte d\u2019insertion peuvent rapidement augmenter le taux d\u2019erreur binaire (BER), entra\u00eenant des erreurs CRC au niveau des trames.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Les d\u00e9bits r\u00e9seau plus \u00e9lev\u00e9s exigent des liaisons physiques plus propres et plus stables.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >Q5 : Les erreurs CRC peuvent-elles ralentir un r\u00e9seau, m\u00eame si la liaison reste active ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Oui. Une liaison peut rester op\u00e9rationnelle tandis que des trames corrompues sont continuellement rejet\u00e9es et retransmises.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cela peut provoquer :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Une latence plus \u00e9lev\u00e9e<\/p><\/li><li><p>D\u00e9bit r\u00e9duit<\/p><\/li><li><p>Retransmissions TCP<\/p><\/li><li><p>instabilit\u00e9 applicative<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Dans de nombreux cas, les utilisateurs remarquent des \u201c performances r\u00e9seau lentes \u201d avant que l\u2019interface ne tombe effectivement en panne.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Q6 : Quelle est la m\u00e9thode la plus rapide pour r\u00e9soudre les erreurs CRC sur une liaison fibre ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La plupart des ing\u00e9nieurs diagnostiquent les erreurs CRC dans cet ordre :<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 219px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"219\"><p>Priorit\u00e9<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Action recommand\u00e9e<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"219\"><p>1<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Nettoyez les connecteurs de fibre<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"219\"><p>2<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Remplacer le c\u00e2ble de raccordement<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"219\"><p>3<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u00c9changer le module SFP<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"219\"><p>4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>V\u00e9rification des niveaux de puissance optique<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"219\"><p>5<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Tester un autre port du commutateur<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Cette approche ax\u00e9e d\u2019abord sur la couche physique r\u00e9sout la plupart des probl\u00e8mes de CRC dans les r\u00e9seaux Ethernet et SFP.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udfe8 Conclusion : Pourquoi la surveillance du CRC est-elle essentielle dans les r\u00e9seaux Ethernet et SFP modernes ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le CRC (contr\u00f4le de redondance cyclique) est l\u2019un des m\u00e9canismes les plus importants pour prot\u00e9ger l\u2019int\u00e9grit\u00e9 des donn\u00e9es dans les communications Ethernet modernes. Que ce soit dans les commutateurs professionnels, les r\u00e9seaux industriels, les grappes d\u2019IA ou les infrastructures fibr\u00e9es haute vitesse, le CRC permet de d\u00e9tecter les paquets corrompus avant qu\u2019ils n\u2019affectent les applications, les syst\u00e8mes de stockage ou la stabilit\u00e9 du r\u00e9seau.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2766fa34efb2466db9faf2fda19e1140.jpg\" alt=\"Why CRC Monitoring Matters in Modern Ethernet and SFP Networks\" class=\"wp-image-7289\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2766fa34efb2466db9faf2fda19e1140.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2766fa34efb2466db9faf2fda19e1140-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2766fa34efb2466db9faf2fda19e1140-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2766fa34efb2466db9faf2fda19e1140-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2766fa34efb2466db9faf2fda19e1140-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Dans les d\u00e9ploiements r\u00e9els, les erreurs CRC r\u00e9currentes ne sont presque jamais al\u00e9atoires. Elles constituent g\u00e9n\u00e9ralement des indicateurs pr\u00e9coces de :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Une mauvaise qualit\u00e9 du signal<\/p><\/li><li><p>Connecteurs de fibre optique sales<\/p><\/li><li><p>C\u00e2blage endommag\u00e9<\/p><\/li><li><p>Att\u00e9nuation optique<\/p><\/li><li><p>Ports de commutateur instables<\/p><\/li><li><p>Modules SFP incompatibles<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c0 mesure que les r\u00e9seaux \u00e9voluent vers l\u2019Ethernet 25 G, 100 G et 400 G, le maintien de performances stables au niveau de la couche physique devient de plus en plus crucial. La surveillance proactive du CRC, la maintenance optique ad\u00e9quate et la compatibilit\u00e9 fiable des transceivers font d\u00e9sormais partie int\u00e9grante des op\u00e9rations r\u00e9seau dans les centres de donn\u00e9es et les t\u00e9l\u00e9communications.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Des liaisons optiques stables produisent des performances stables du CRC.<\/p><\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">Pour les entreprises qui construisent une infrastructure Ethernet fibr\u00e9e fiable, le choix de transceivers optiques de haute qualit\u00e9 et enti\u00e8rement compatibles constitue l\u2019un des moyens les plus efficaces de r\u00e9duire les probl\u00e8mes r\u00e9seau li\u00e9s au CRC.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">D\u00e9couvrez les transceivers optiques SFP, SFP+, SFP28 et QSFP professionnels sur le <a target=\"_self\" href=\"https:\/\/www.l-p.com\/\">Boutique officielle LINK-PP<\/a> pour une connectivit\u00e9 Ethernet stable et haute performance.<\/p>","protected":false},"excerpt":{"rendered":"<p>Comprenez ce qu\u2019est le CRC, comment les erreurs de contr\u00f4le de redondance cyclique se produisent, comment les r\u00e9soudre, et pourquoi le CRC est essentiel dans les r\u00e9seaux, le stockage et les modules SFP.<\/p>","protected":false},"author":1,"featured_media":7290,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[27],"tags":[26],"class_list":["post-7291","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-glossary","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/7291","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/comments?post=7291"}],"version-history":[{"count":6,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/7291\/revisions"}],"predecessor-version":[{"id":10687,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/7291\/revisions\/10687"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media\/7290"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media?parent=7291"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/categories?post=7291"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/tags?post=7291"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}