{"id":5460,"date":"2025-08-14T00:00:00","date_gmt":"2025-08-14T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/poe-rj45-connectors-rated-current\/"},"modified":"2026-06-22T08:29:02","modified_gmt":"2026-06-22T08:29:02","slug":"poe-rj45-connectors-rated-current","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/poe-rj45-connectors-rated-current","title":{"rendered":"Comprendre le courant nominal des connecteurs RJ45 int\u00e9gr\u00e9s"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/558ae5d8b7f64ebfb9be887136ff2890.webp\" alt=\"Rated Current for PoE RJ45 Connectors\" class=\"wp-image-5457\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/558ae5d8b7f64ebfb9be887136ff2890.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/558ae5d8b7f64ebfb9be887136ff2890-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/558ae5d8b7f64ebfb9be887136ff2890-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/558ae5d8b7f64ebfb9be887136ff2890-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/558ae5d8b7f64ebfb9be887136ff2890-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >Introduction<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Les appareils connect\u00e9s d\u00e9pendent de plus en plus de <strong>PoE (alimentation par Ethernet)<\/strong> pour simplifier le c\u00e2blage et permettre des d\u00e9ploiements plus intelligents. Les connecteurs RJ45 int\u00e9gr\u00e9s dot\u00e9s de composants magn\u00e9tiques \u2014 souvent appel\u00e9s <strong><em>MagJacks<\/em><\/strong>\u2014 doivent transporter de fa\u00e7on fiable \u00e0 la fois les donn\u00e9es et l\u2019alimentation. Comprendre leurs valeurs nominales de courant est essentiel lors de la conception de mat\u00e9riel r\u00e9seau conforme aux normes IEEE PoE. Dans cet article, nous clarifions les valeurs nominales de courant typiques, mettons en \u00e9vidence les facteurs influen\u00e7ant ces valeurs et pr\u00e9sentons <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-17492-integrated-rj45-connector.htm\"><strong>le MagJack LINK-PP<\/strong><\/a> solutions plus \u00e9cologiques.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Valeurs nominales de courant : pas une solution universelle<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Les valeurs nominales de courant des connecteurs RJ45 int\u00e9gr\u00e9s varient selon :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>la m\u00e9tallurgie et le placage des contacts<\/strong> (par exemple, du cuivre pur avec un placage or \u00e9pais am\u00e9liore la conductivit\u00e9).<\/p><\/li><li><p><strong>la g\u00e9om\u00e9trie du connecteur<\/strong>, tels que la taille des broches, leur espacement et la gestion thermique.<\/p><\/li><li><p><strong>l\u2019usage signal ou puissance<\/strong>\u2014 l\u2019Ethernet standard utilise un courant minimal (&lt; 100 mA), tandis que le PoE sollicite les contacts \u00e0 leur limite.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>LINK-PP sp\u00e9cifie jusqu\u2019\u00e0 <strong>750 mA par contact<\/strong> dans sa version PoE+ <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/products\/rj45-connector-with-integrated-magnetics-lpjg0926henl-poe-plus\/\">LPJG0926HENL<\/a> .<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >Comment les normes PoE d\u00e9finissent les exigences en courant<\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 97px;\"\/><col style=\"width: 112px;\"\/><col style=\"width: 103px;\"\/><col style=\"width: 98px;\"\/><col style=\"width: 98px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"97\"><p><strong>Type PoE<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"112\"><p><strong>Puissance maximale fournie<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"103\"><p><strong>Tension typique<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"98\"><p><strong>Courant par paire<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"98\"><p><strong>Nombre de paires<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Courant total<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"97\"><p>IEEE 802.3af <strong>Puissance disponible du PD<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"112\"><p>12,95 W (vers le PD)<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"103\"><p>44\u201357 V<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"98\"><p>350 mA<br> <\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"98\"><p>2<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2248 <strong>0,35 A<\/strong> (conservateur standard) <\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"97\"><p>IEEE 802.3at <strong>T\u00e9l\u00e9phones IP, WAP de base<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"112\"><p>25,5 W<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"103\"><p>50\u201357 V<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"98\"><p>600 mA<br> <\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"98\"><p>2<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2248 0,6 A par paire \u00d72 = <strong>1,2 A<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"97\"><p>IEEE 802.3bt <strong>(PoE++)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"112\"><p>51 W<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"103\"><p>50\u201357 V<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"98\"><p>600 mA<br> <\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"98\"><p>4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2248 0,6 A \u00d74 = <strong>2,4 A<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"97\"><p>IEEE 802.3bt <strong>Clients minces, terminaux POS<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"112\"><p>71,3 W<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"103\"><p>52\u201357 V<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"98\"><p>960 mA <\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"98\"><p>4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2248 0,96 A \u00d74 = <strong>3,84 A<\/strong><\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Bien que le courant th\u00e9orique soit d\u00e9riv\u00e9 de la formule puissance \u00f7 tension, l\u2019IEEE d\u00e9finit des limites de s\u00e9curit\u00e9 <strong><em>par paire<\/em><\/strong>. Cela garantit une qualification coh\u00e9rente des connecteurs et une s\u00e9curit\u00e9 thermique.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >Exemple : connecteur PoE+ LINK-PP LPJG0926HENL<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ff37a1694d7047578478950769526d70.png\" alt=\"LINK-PP LPJG0926HENL PoE+ Connector\" class=\"wp-image-5458\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ff37a1694d7047578478950769526d70.png 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ff37a1694d7047578478950769526d70-300x178.png 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ff37a1694d7047578478950769526d70-1024x608.png 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ff37a1694d7047578478950769526d70-768x456.png 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ff37a1694d7047578478950769526d70-18x12.png 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/439792.htm\"><strong>LPJG0926HENL<\/strong><\/a> Le MagJack PoE+ prend en charge <strong>IEEE 802.3at<\/strong> dot\u00e9 d\u2019une <strong>une valeur nominale de courant de 720 mA par contact<\/strong>. Puisque le PoE+ utilise deux paires, cette valeur nominale par contact offre une marge confortable pour assurer la fiabilit\u00e9 dans des conditions r\u00e9elles d\u2019utilisation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ce type de marge est essentiel pour des performances durables dans des conceptions compactes, o\u00f9 une accumulation de chaleur et plusieurs cycles thermiques peuvent survenir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Implications pour la conception et bonnes pratiques<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u2605 <\/strong><span><strong>S\u00e9lectionnez des connecteurs avec marge :<\/strong> Choisissez des composants dont la valeur nominale de courant d\u00e9passe le minimum requis par la norme. Les MagJacks LINK-PP d\u00e9passent g\u00e9n\u00e9ralement les exigences de base.<\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u2605 <\/strong><span><strong>V\u00e9rifiez les conditions indiqu\u00e9es dans la fiche technique :<\/strong> Assurez-vous que la valeur nominale de courant est sp\u00e9cifi\u00e9e \u00e0 une temp\u00e9rature ambiante de <strong>25 \u00b0C<\/strong> avec une \u00e9l\u00e9vation de temp\u00e9rature \u2264 20 \u00b0C.<\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u2605 <\/strong><span><strong>Envisagez l\u2019usage de quatre paires :<\/strong> Pour les conceptions PoE++, assurez-vous que les connecteurs sont certifi\u00e9s pour les normes <strong>IEEE 802.3bt Type 3 ou 4<\/strong>, c\u2019est-\u00e0-dire <strong>\u2265 600 mA ou \u2265 960 mA par paire<\/strong>.<\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u2605 <\/strong><span><strong>Adaptez c\u00e2ble, transformateur et carte PCB :<\/strong> Chaque segment, du connecteur aux composants magn\u00e9tiques, aux pistes et au c\u00e2ble, influence le chemin global de puissance et la temp\u00e9rature.<\/span><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Conclusion<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-17492-integrated-rj45-connector.htm\">Les MagJacks RJ45 int\u00e9gr\u00e9s<\/a> sont con\u00e7us pour r\u00e9pondre \u00e0 des exigences sp\u00e9cifiques de courant selon les normes PoE.<\/p><\/li><li><p>Bien qu\u2019un connecteur g\u00e9n\u00e9rique puisse supporter 1\u20132 A par contact, un d\u00e9ploiement fiable exige une ad\u00e9quation stricte aux exigences nominales de courant des normes. <strong>par paire<\/strong>.<\/p><\/li><li><p>Les MagJacks LINK-PP \u2014 notamment des mod\u00e8les comme le LPJG0926HENL \u2014 offrent des valeurs nominales robustes (750 mA\/contact) avec prise en charge de la norme IEEE 802.3at.<\/p><\/li><li><p>Pour des conceptions PoE haute puissance et \u00e9volutives, assurez-vous que les connecteurs prennent en charge <strong>les Types 3 ou 4 (\u2265 600 mA \u2013 960 mA par paire)<\/strong>.<\/p><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>D\u00e9couvrez comment les connecteurs RJ45 int\u00e9gr\u00e9s prennent en charge les donn\u00e9es et l\u2019alimentation \u2014 couvrant les normes IEEE PoE, le courant nominal par contact\/paire, ainsi que les analyses fiables de produits LINK-PP.<\/p>","protected":false},"author":1,"featured_media":5459,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[22],"class_list":["post-5460","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-integrated-rj45-connectors"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/5460","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/comments?post=5460"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/5460\/revisions"}],"predecessor-version":[{"id":11258,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/5460\/revisions\/11258"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media\/5459"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media?parent=5460"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/categories?post=5460"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/tags?post=5460"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}