{"id":5436,"date":"2025-08-15T00:00:00","date_gmt":"2025-08-15T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/psm4-vs-cwdm4-which-optical-transceiver-for-your-network\/"},"modified":"2026-06-22T08:25:49","modified_gmt":"2026-06-22T08:25:49","slug":"psm4-vs-cwdm4-which-optical-transceiver-for-your-network","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/psm4-vs-cwdm4-which-optical-transceiver-for-your-network","title":{"rendered":"PSM4 vs.\u00a0CWDM4 Quel \u00e9metteur-r\u00e9cepteur optique est adapt\u00e9 \u00e0 votre r\u00e9seau"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9.webp\" alt=\"100G PSM4 VS CWDM4\" class=\"wp-image-5432\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">La demande pour la connectivit\u00e9 100G dans les centres de donn\u00e9es et les r\u00e9seaux d'entreprise explose. Choisir le bon <strong>\u00e9metteur-r\u00e9cepteur optique<\/strong> <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>(100G QSFP28)<\/strong><\/a> est essentiel pour la performance, le co\u00fbt, l'\u00e9volutivit\u00e9 et l'efficacit\u00e9 \u00e9nerg\u00e9tique. Deux normes dominantes <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/multi-source-agreements-optical-transceivers\/\"><strong>MSA<\/strong><\/a> (Accord Multi-Sources) sont apparues : <strong>PSM4 (Fibre monomode parall\u00e8le 4 voies)<\/strong> and <strong>CWDM4 (Multiplexage en longueur d'onde grossi\u00e8re 4 voies)<\/strong>. Bien que les deux atteignent 100G sur 2 km en utilisant une fibre monomode <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/what-is-single-mode-fiber-and-how-does-it-work\/\"><strong>(SMF)<\/strong><\/a>, leurs technologies sous-jacentes et leurs cas d'utilisation id\u00e9aux diff\u00e8rent consid\u00e9rablement. Comprendre ces diff\u00e9rences entre \u00e9metteurs-r\u00e9cepteurs 100G est essentiel pour optimiser les r\u00e9seaux de centres de donn\u00e9es et r\u00e9duire les co\u00fbts des interconnexions optiques.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udd27 PSM4 : Puissance du parall\u00e9lisme<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"618\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda.webp\" alt=\"100G PSM4\" class=\"wp-image-5433\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda-300x155.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda-1024x527.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda-768x396.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda-18x9.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">PSM4 (IEEE 802.3bm) adopte une approche parall\u00e8le simple :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Technologie :<\/strong> Utilise 4 voies optiques ind\u00e9pendantes (chacune \u00e0 <em>1310 nm de longueur d'onde)<\/em>).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fibre :<\/strong> N\u00e9cessite <strong>8 fibres<\/strong> (4 Tx, 4 Rx) \u2013 g\u00e9n\u00e9ralement dans un connecteur MPO-12.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fonctionnement :<\/strong> Chaque voie transmet simultan\u00e9ment des donn\u00e9es \u00e0 25 Gbps via sa paire de fibres d\u00e9di\u00e9e.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Avantages :<\/strong> Conception optique plus simple pouvant entra\u00eener des co\u00fbts de composants inf\u00e9rieurs, excellente isolation du signal.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Inconv\u00e9nients :<\/strong> Consommation \u00e9lev\u00e9e de fibres, c\u00e2bles plus volumineux.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Id\u00e9al pour :<\/strong> Des liaisons tr\u00e8s courtes (\u2264 500 m) \u00e0 l'int\u00e9rieur des baies ou rang\u00e9es, des sc\u00e9narios d'attachement direct haute densit\u00e9 o\u00f9 le nombre de fibres n'est pas une contrainte principale. Un module optique fiable <strong>PSM4<\/strong> comme <strong>LINK-PP LQ-M31100-DR4C<\/strong> offre des performances constantes pour ces applications exigeantes <strong>d\u2019optique parall\u00e8le<\/strong>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83c\udf08 CWDM4 : Magie de la longueur d'onde<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b.webp\" alt=\"100G CWDM4\" class=\"wp-image-5434\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">CWDM4 (Sp\u00e9cification MSA) utilise le multiplexage optique pour \u00e9conomiser des fibres :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Technologie :<\/strong> Utilise 4 longueurs d'onde CWDM diff\u00e9rentes (~1271 nm, 1291 nm, 1311 nm, 1331 nm) multiplex\u00e9es sur une <em>seul<\/em> paire de fibres.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fibre :<\/strong> N\u00e9cessite seulement <strong>2 fibres<\/strong> (1 Tx, 1 Rx) \u2013 typiquement LC duplex.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fonctionnement :<\/strong> Un multiplexeur (Mux) combine les 4 longueurs d'onde sur la fibre Tx ; un d\u00e9multiplexeur (Demux) les s\u00e9pare \u00e0 l'autre extr\u00e9mit\u00e9 Rx.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Avantages :<\/strong> R\u00e9duit drastiquement le nombre de fibres (4 fois moins que PSM4), c\u00e2bles plus petits, gestion des c\u00e2bles facilit\u00e9e, connecteurs LC standards.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Inconv\u00e9nients :<\/strong> N\u00e9cessite des lasers et des composants Mux\/Demux plus complexes (et potentiellement plus chers).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Id\u00e9al pour :<\/strong> The <strong>sweet spot pour la plupart des liaisons 2km 100G<\/strong> (par exemple, interconnexion intra-data center, liaisons campus). C\u2019est la solution de r\u00e9f\u00e9rence pour <strong>l'efficacit\u00e9 fibre CWDM4 <\/strong> and <strong>connectivit\u00e9 100G \u00e9conomique<\/strong>. Le <strong>LIEN-PP <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472577.htm\"><strong>LQ-CW100-FR4C<\/strong><\/a> est con\u00e7u pour une fiabilit\u00e9 maximale dans ces r\u00e9seaux multiplex\u00e9s en longueur d'onde.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83e\udd4a Face-\u00e0-face : PSM4 vs. CWDM4 \u2013 Les diff\u00e9rences cl\u00e9s<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Fonctionnalit\u00e9<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>PSM4 (100G-PSM4)<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4 (100G-CWDM4)<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Gagnant pour\u2026<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Technologie<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 voies parall\u00e8les 1310nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4x WDM (1271\/1291\/1311\/1331nm)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Simplicit\u00e9 (PSM4) \/ Efficacit\u00e9 Fibre (CWDM4)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Fiber Count<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>8 Fibres<\/strong> (MPO-12)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>2 Fibres<\/strong> (LC Duplex)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4<\/strong> (\u00c9conomies significatives)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Reach<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Jusqu'\u00e0 500m (Optimal), 2km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Jusqu'\u00e0 2km (Standard)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u00c9galit\u00e9 (Les deux font 2km, PSM4 meilleur \u2264500m)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Connecteur<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>MPO-12\/APC<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>LC duplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4<\/strong> (Standard, Gestion plus facile)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Complexit\u00e9 laser<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Plus simple (4x m\u00eame \u03bb)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Plus complexe (4x \u03bb diff\u00e9rents, Mux\/Demux)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>PSM4<\/strong> (Co\u00fbt potentiellement inf\u00e9rieur)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Volume c\u00e2ble<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Plus \u00e9lev\u00e9 (c\u00e2ble plus \u00e9pais)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Plus faible (c\u00e2ble plus fin)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Cas d\u2019utilisation principal<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Courte port\u00e9e, Haute densit\u00e9<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Liaison standard 2km ICI, DCI<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>D\u00e9pend de la distance\/besoins en fibre<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Facteur co\u00fbt (Composants)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Laser potentiellement moins cher<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Laser potentiellement plus cher + Mux\/Demux<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>D\u00e9pend du contexte<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Facteur co\u00fbt (Infrastructure)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Plus \u00e9lev\u00e9 (Plus de fibre\/c\u00e2blage)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Lower<\/strong> (Moins de fibre\/c\u00e2blage)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4<\/strong> (Co\u00fbt total infrastructure)<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83c\udfc6 Choisir votre champion : PSM4 ou CWDM4 ?<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px 0px 4px;\"><strong>Choisissez PSM4 Si :<\/strong><\/p><ul><li><p style=\"margin: 0px;\">Vos liaisons sont <strong>tr\u00e8s courtes (\u2264 500m)<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>L\u2019infrastructure fibre est abondante et bon march\u00e9<\/strong>, et le volume des c\u00e2bles n\u2019est pas un probl\u00e8me majeur.<\/p><\/li><li><p style=\"margin: 0px;\">Vous privil\u00e9giez le potentiel <strong>d\u2019\u00e9conomies sur les composants<\/strong> plut\u00f4t que l'efficacit\u00e9 fibre <em>pour certains d\u00e9ploiements \u00e0 courte port\u00e9e<\/em>.<\/p><\/li><li><p style=\"margin: 0px;\">Vous avez besoin de <strong>modules optiques parall\u00e8les haute densit\u00e9<\/strong> dans un espace restreint.<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>Choisissez CWDM4 Si (Le choix le plus courant) :<\/strong><\/p><ul><li><p style=\"margin: 0px;\">Vos liaisons sont <strong>jusqu\u2019\u00e0 2km<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>La conservation de la fibre est cruciale<\/strong> (\u00e9conomise un co\u00fbt et une complexit\u00e9 importants).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Une gestion plus facile des c\u00e2bles<\/strong> avec LC duplex est pr\u00e9f\u00e9r\u00e9e.<\/p><\/li><li><p style=\"margin: 0px;\">Vous avez besoin d\u2019une <strong>solution standard largement interop\u00e9rable<\/strong> pour les interconnexions de data centers (DCI) ou les liaisons dorsales d\u2019entreprise.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Le co\u00fbt global de l\u2019infrastructure<\/strong> (fibre + c\u00e2blage + gestion) est un facteur d\u00e9terminant.<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\ud83d\udca1 Solutions LINK-PP : Con\u00e7ues pour la performance et la valeur<\/strong><br\/>Que votre conception r\u00e9seau 100G n\u00e9cessite l'efficacit\u00e9 parall\u00e8le de <strong>PSM4<\/strong> ou la puissance du multiplexage en longueur d'onde de <strong>CWDM4<\/strong>,<a target=\"_blank\" rel=\"\" href=\"https:\/\/www.link-pp.com\/\"><strong> LIEN-PP<\/strong><\/a> fournit des solutions hautes performances conformes aux normes MSA :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Pour un parall\u00e9lisme exigeant \u00e0 courte port\u00e9e :<\/strong> The <strong>\u00c9metteurs-r\u00e9cepteurs LINK-PP PSM4<\/strong> offre des performances robustes pour les optiques 100G sensibles aux co\u00fbts dans des applications denses \u00e0 courte distance.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Pour une interconnexion efficace sur 2 km :<\/strong> <strong>LIEN-PP<\/strong> fournit une consommation fiable et faible en \u00e9nergie <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472577.htm\"><strong>100G<\/strong> <strong>\u00c9metteurs-r\u00e9cepteurs CWDM4<\/strong><\/a> optimis\u00e9s pour des solutions \u00e9volutives de centres de donn\u00e9es et des r\u00e9seaux d'entreprise \u00e0 haut d\u00e9bit.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Les deux modules subissent des <strong>tests rigoureux d'\u00e9metteurs-r\u00e9cepteurs optiques<\/strong> pour garantir la compatibilit\u00e9, un faible <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/understanding-what-is-bit-error-rate\/\"><strong>taux d'erreur binaire (BER)<\/strong><\/a>, et une longue dur\u00e9e de vie, vous donnant confiance dans votre infrastructure r\u00e9seau optique.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Conclusion : Optimisation de votre edge optique<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La compr\u00e9hension du <strong>diff\u00e9rences entre PSM4 et CWDM4<\/strong> est fondamentale pour prendre des d\u00e9cisions \u00e9clair\u00e9es <strong>s\u00e9lection d'\u00e9metteurs-r\u00e9cepteurs 100G<\/strong>. Bien que le PSM4 offre une simplicit\u00e9 pour les liaisons parall\u00e8les ultra-courtes, <strong>le CWDM4 est devenu la norme dominante pour les liaisons 100G sur 2 km gr\u00e2ce \u00e0 son efficacit\u00e9 sup\u00e9rieure en fibres, une gestion plus facile et des co\u00fbts d'infrastructure globalement plus bas.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pr\u00eat \u00e0 optimiser votre d\u00e9ploiement 100G avec la bonne solution optique ? \ud83d\udd17<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\ud83d\udc49 D\u00e9couvrez toute la gamme de modules QSFP28 100G haute performance et fiables de LINK-PP, notamment nos transceivers CWDM4 et PSM4 leaders sur le march\u00e9, con\u00e7us pour offrir une valeur maximale et un temps de fonctionnement optimal \u00e0 vos liaisons critiques. <\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>Visitez notre page produit \u279e<\/strong><\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>Que faire si votre commutateur ne s\u2019allume pas ?<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Quelle est la principale diff\u00e9rence entre le PSM4 et le CWDM4 ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le PSM4 n\u00e9cessite huit fibres et utilise des connecteurs MPO\/MTP. Il envoie les donn\u00e9es en parall\u00e8le. Le CWDM4 n\u2019a besoin que de deux fibres et utilise des connecteurs LC duplex. Il envoie les donn\u00e9es en utilisant diff\u00e9rentes longueurs d\u2019onde.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Le PSM4 convient aux courtes distances. Le CWDM4 est meilleur pour les longues distances.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >Quel transceiver est plus facile \u00e0 installer dans les r\u00e9seaux existants ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le CWDM4 est g\u00e9n\u00e9ralement plus facile \u00e0 int\u00e9grer. La plupart des r\u00e9seaux utilisent d\u00e9j\u00e0 des connecteurs LC et des c\u00e2bles \u00e0 deux fibres.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Le PSM4 peut n\u00e9cessiter une nouvelle fibre parall\u00e8le si vous ne l\u2019avez pas.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Quelle option est la plus \u00e9conomique pour les courtes distances ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le PSM4 co\u00fbte souvent moins cher pour les courtes liaisons si vous disposez d\u00e9j\u00e0 de fibres parall\u00e8les.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Le CWDM4 permet d\u2019\u00e9conomiser sur les c\u00e2bles pour les nouveaux r\u00e9seaux ou les extensions.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >Est-ce que le PSM4 et le CWDM4 peuvent tous les deux prendre en charge les mises \u00e0 niveau futures du r\u00e9seau ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le CWDM4 est pr\u00e9f\u00e9rable pour les mises \u00e0 niveau. Il utilise moins de fibres, donc il est facile d\u2019en ajouter davantage.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Le PSM4 pourrait n\u00e9cessiter plus d\u2019espace lorsque votre r\u00e9seau s\u2019agrandit.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Quel transceiver un centre de donn\u00e9es devrait-il choisir pour les longues liaisons ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un centre de donn\u00e9es devrait opter pour le CWDM4 pour des liaisons allant jusqu\u2019\u00e0 2 kilom\u00e8tres.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Le PSM4 est id\u00e9al pour les courtes liaisons \u00e0 l\u2019int\u00e9rieur d\u2019un b\u00e2timent.<\/p><\/blockquote>","protected":false},"excerpt":{"rendered":"<p>Comparez le PSM4 et le CWDM4 afin de choisir le bon transceiver optique 100G pour votre r\u00e9seau selon la distance, le c\u00e2blage, le co\u00fbt et les besoins de mise \u00e0 niveau.<\/p>","protected":false},"author":1,"featured_media":5435,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13],"class_list":["post-5436","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/5436","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/comments?post=5436"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/5436\/revisions"}],"predecessor-version":[{"id":11253,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/5436\/revisions\/11253"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media\/5435"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media?parent=5436"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/categories?post=5436"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/tags?post=5436"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}