{"id":5407,"date":"2025-08-18T00:00:00","date_gmt":"2025-08-18T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/qsfp28-100g-psm4-transceivers-for-data-centers\/"},"modified":"2026-06-22T08:21:27","modified_gmt":"2026-06-22T08:21:27","slug":"qsfp28-100g-psm4-transceivers-for-data-centers","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/qsfp28-100g-psm4-transceivers-for-data-centers","title":{"rendered":"D\u00e9bloquez la connectivit\u00e9 haute densit\u00e9 100G : Votre guide vers le module optique 100G PSM4"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e8c59990135f47488a1f089f23f62ace.webp\" alt=\"QSFP28 100G PSM4 Transceivers\" class=\"wp-image-5405\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e8c59990135f47488a1f089f23f62ace.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e8c59990135f47488a1f089f23f62ace-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e8c59990135f47488a1f089f23f62ace-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e8c59990135f47488a1f089f23f62ace-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e8c59990135f47488a1f089f23f62ace-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">La pouss\u00e9e incessante du cloud computing, de l'IA et des applications hyperscalaires exige des interconnexions de centres de donn\u00e9es (DCI) toujours plus rapides, denses et rentables. D\u00e9couvrez le <\/span><span class=\"qc-p1-tag\"><strong>module optique 100G PSM4 (Parallel Single-Mode 4-lane)<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\"> - un cheval de trait essentiel alimentant des liens Ethernet 100 Gigabit (100GbE) efficaces. Ce guide explore en profondeur ce qui fait de PSM4 une solution vitale pour l'infrastructure r\u00e9seau moderne.<\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udca1 Conna\u00eetre la technologie PSM4 aide les ing\u00e9nieurs r\u00e9seau \u00e0 choisir la meilleure option pour des performances robustes et \u00e9volutives.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\ud83d\udcdd Qu'est-ce qu'un module optique 100G PSM4 ?<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Un transpondeur 100G PSM4 est un module optique enfichable con\u00e7u pour la transmission<strong>00G Ethernet<\/strong> sur <strong>. Que vous soyez connect\u00e9s aux b\u00e2timents campus, \u00e9tablissement de liens m\u00e9tro ou mise en \u0153uvre de DCI, comprendre les capacit\u00e9s et les meilleures pratiques de d\u00e9ploiement est cl\u00e9 pour le succ\u00e8s. <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/what-is-single-mode-fiber-and-how-does-it-work\/\"><strong>(SMF)<\/strong><\/a>. Il utilise quatre voies optiques ind\u00e9pendantes, chacune fonctionnant \u00e0 25Gbps (en utilisant <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/understanding-non-return-to-zero-in-digital-communication\/\"><strong>modulation NRZ<\/strong><\/a>) \u00e0 la <strong>1310 nm de longueur d'onde)<\/strong>. Contrairement aux <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/100g-cwdm4-transceiver-efficient-2km-links\/\"><strong>100G<\/strong> <strong>\u00c9metteurs-r\u00e9cepteurs CWDM4<\/strong><\/a>, qui multiplexe les longueurs d'onde sur une seule paire de fibres, PSM4 n\u00e9cessite <strong>huit fibres<\/strong> (4 Tx, 4 Rx) - une paire d\u00e9di\u00e9e pour chaque voie. Cette approche \u201coptique parall\u00e8le\u201d offre des avantages distincts.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\ud83d\udcdd Principaux avantages de la technologie 100G PSM4<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Efficacit\u00e9 co\u00fbt :<\/strong> \ud83d\udcb0 PSM4 exploite des composants optiques moins chers compar\u00e9s aux solutions de multiplexage par longueur d'onde comme <strong>CWDM4<\/strong>. Les optiques plus simples se traduisent par un <strong>transpondeur 100G moins cher<\/strong>, particuli\u00e8rement significatif pour les d\u00e9ploiements \u00e0 grande \u00e9chelle.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Faible latence :<\/strong> \u26a1 Le chemin de transmission parall\u00e8le direct minimise la complexit\u00e9 du traitement du signal, r\u00e9sultant en <strong>une latence ultra-basse<\/strong> - critique pour le trading \u00e0 haute fr\u00e9quence, les clusters IA et les applications financi\u00e8res.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Haute densit\u00e9 et \u00e9volutivit\u00e9 :<br><\/strong> \u2b50 Les modules PSM4 sont g\u00e9n\u00e9ralement au format <strong>QSFP28<\/strong>, permettant une haute densit\u00e9 de ports sur les commutateurs et routeurs. Ils sont id\u00e9aux pour <strong>architectures leaf-spine<\/strong> and <strong>top-of-rack (ToR)<\/strong> to <strong>agr\u00e9gation\/distribution<\/strong> connexions de commutateur dans une salle de centre de donn\u00e9es.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Performance SMF fiable :<\/strong> \ud83d\ude80 L'utilisation de la fibre monomode \u00e9prouv\u00e9e garantit <strong>un potentiel de port\u00e9e plus longue<\/strong> (jusqu'\u00e0 500m, souvent 2km avec des modules de qualit\u00e9 comme ceux de LINK-PP) et <strong>des performances sup\u00e9rieures<\/strong> compar\u00e9es aux solutions multimodes (comme SR4) sur des distances similaires.<\/p><\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\ud83d\udcdd Applications id\u00e9ales pour les modules 100G PSM4<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Interconnexion de centres de donn\u00e9es (DCI) :<\/strong> Dans un seul b\u00e2timent de centre de donn\u00e9es ou un campus (jusqu'\u00e0 500 m - 2 km).<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Calcul haute performance <\/strong><a href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/what-is-hpc-high-performance-computing\/\" target=\"_blank\" rel=\"\"><strong>(HPC)<\/strong><\/a><strong> Clusters :<\/strong> L\u00e0 o\u00f9 la faible latence et la bande passante \u00e9lev\u00e9e sont incontournables.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>C\u0153ur\/r\u00e9agr\u00e9gation du r\u00e9seau d'entreprise :<\/strong> Mise \u00e0 niveau des liens dorsaux pour les applications gourmandes en bande passante.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Infrastructure des fournisseurs de cloud :<\/strong> Connexion des serveurs, du stockage et des commutateurs dans les environnements cloud \u00e0 grande \u00e9chelle.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>R\u00e9seaux financiers :<\/strong> Prise en charge des plateformes de trading \u00e0 faible latence.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\ud83d\udcdd PSM4 vs. CWDM4 : Choisir la bonne solution 100G SMF<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Fonctionnalit\u00e9<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>100G PSM4<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>100G CWDM4<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Technologie<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Optique parall\u00e8le (4 voies)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/wdm-optical-transceiver-module-applications\/\"><strong>WDM<\/strong><\/a> (4 longueurs d'onde sur 1 paire)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Fiber Count<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>8 Fibres<\/strong> (4 Tx, 4 Rx)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>2 Fibres<\/strong> (1 Tx, 1 Rx)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Reach<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Jusqu'\u00e0 500 m (Courant), <strong>2 km +<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Jusqu'\u00e0 2 km<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Cost<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>G\u00e9n\u00e9ralement inf\u00e9rieur<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Plus \u00e9lev\u00e9<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Latence<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Ultra-faible<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Faible<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Complexit\u00e9<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Inf\u00e9rieur (Optiques)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Sup\u00e9rieur (N\u00e9cessite un multiplexeur\/d\u00e9multiplexeur WDM)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Id\u00e9al pour<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Liens intra-DC haute densit\u00e9 et sensibles au co\u00fbt &lt;2 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Liens o\u00f9 la fibre est rare, jusqu'\u00e0 2 km<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\ud83d\udcdd Pourquoi choisir les modules optiques LINK-PP 100G PSM4 ?<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"608\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39cdcc49922c4d8ebdd258250cf678e9-1024x608.webp\" alt=\"LINK-PP 100G PSM4 Solutions\" class=\"wp-image-5406\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39cdcc49922c4d8ebdd258250cf678e9-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39cdcc49922c4d8ebdd258250cf678e9-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39cdcc49922c4d8ebdd258250cf678e9-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39cdcc49922c4d8ebdd258250cf678e9-18x12.webp 18w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39cdcc49922c4d8ebdd258250cf678e9.webp 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Quand la fiabilit\u00e9, les performances et la valeur sont primordiales, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.link-pp.com\/\"><strong>LIEN-PP<\/strong><\/a> se d\u00e9marque. Notre <strong>transcepteurs 100G PSM4 QSFP28<\/strong> sont con\u00e7us pour l'excellence :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Garantie de compatibilit\u00e9 :<\/strong> Test\u00e9s rigoureusement pour un fonctionnement transparent avec les principaux commutateurs OEM (Cisco, Juniper, Arista, etc.). \u00c9vitez les risques des modules g\u00e9n\u00e9riques.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Qualit\u00e9 et fiabilit\u00e9 sup\u00e9rieures :<\/strong> Fabriqu\u00e9s selon les normes les plus strictes, assurant une faible <strong>les taux d'erreur binaire <\/strong><a href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/understanding-what-is-bit-error-rate\/\" target=\"_self\"><strong>(BER)<\/strong><\/a> et une longue dur\u00e9e de vie op\u00e9rationnelle \u2013 parfait pour <strong>liens critiques du centre de donn\u00e9es<\/strong>.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Port\u00e9e \u00e9tendue :<\/strong> Notre <strong>LIEN-PP <\/strong><a href=\"https:\/\/www.l-p.com\/products\/488422.htm\" target=\"_blank\" rel=\"\"><strong>LQ-M31100-FR4C<\/strong><\/a> mod\u00e8le atteint de mani\u00e8re fiable <strong>jusqu\u2019\u00e0 2km<\/strong> sur fibre monomode, offrant une plus grande flexibilit\u00e9 de d\u00e9ploiement.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>\u00c9conomies de co\u00fbts :<\/strong> Exp\u00e9rience significative <strong>r\u00e9duction du CAPEX<\/strong> sans compromettre les performances ou la stabilit\u00e9.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Garantie et assistance compl\u00e8tes :<\/strong> Soutenu par une assistance et une garantie leaders dans le secteur.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>D\u00e9bloquez votre potentiel 100G avec LINK-PP !<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Optimisez votre tissu de centre de donn\u00e9es avec des performances \u00e9lev\u00e9es, rentables <strong>100G connectivity<\/strong>. Que vous d\u00e9ployiez de nouvelles infrastructures ou que vous mettiez \u00e0 niveau des liens existants, <strong>Les transcepteurs 100G PSM4 de LINK-PP<\/strong> fournissent la base fiable et \u00e0 faible latence dont vous avez besoin.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pr\u00eat \u00e0 explorer les modules LINK-PP 100G PSM4 ?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u27a1\ufe0f <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/488422.htm\"><strong>LQ-M31100-FR4C (2 km)<\/strong><\/a><br>\u27a1\ufe0f <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/488423.htm\"><strong>LQ-M31100-LR4C (10 km)<\/strong><\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\ud83d\udcdd FAQ<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Que signifie PSM4 ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PSM4 signifie \u201c Parallel Single Mode 4-lane \u201d. Le transcepteur utilise quatre fibres pour envoyer des donn\u00e9es. Il utilise \u00e9galement quatre fibres pour recevoir des donn\u00e9es. Chaque voie transporte 25 Gbps.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Le QSFP28 100G PSM4 fonctionne-t-il avec les c\u00e2bles \u00e0 fibre monomode existants ?<\/h3>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Oui, les modules SFP28 100G PSM4 fonctionnent avec la fibre monomode normale (OS2). De nombreux centres de donn\u00e9es utilisent d\u00e9j\u00e0 ce type de fibre. Cela facilite les mises \u00e0 niveau et permet d'\u00e9conomiser de l'argent.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">Comment surveillez-vous l'\u00e9tat d'un module PSM4 ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les gestionnaires de r\u00e9seau utilisent la surveillance diagnostique num\u00e9rique, appel\u00e9e DDM. Le DDM affiche des \u00e9l\u00e9ments tels que la temp\u00e9rature, la tension et la force du signal. Cela les aide \u00e0 d\u00e9tecter et r\u00e9soudre rapidement les probl\u00e8mes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Quel connecteur le QSFP28 100G PSM4 utilise-t-il ?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Le module utilise un connecteur MPO\/MTP-12.<\/p><\/li>\n\n\n\n<li><p>Ce connecteur contient douze fibres align\u00e9es sur une seule rang\u00e9e.<\/p><\/li>\n\n\n\n<li><p>Huit fibres transmettent les donn\u00e9es, et quatre ne sont pas utilis\u00e9es.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Le QSFP28 100G PSM4 est-il inscriptible \u00e0 chaud ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Oui, vous pouvez ins\u00e9rer ou retirer le module sans \u00e9teindre l'appareil. Cela permet au r\u00e9seau de continuer \u00e0 fonctionner pendant les mises \u00e0 niveau ou les r\u00e9parations.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Voir aussi<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/100g-qsfp28-optical-transceivers-selection-guide\/\">Explorer les modules optiques 100G QSFP28 : SR4, LR4, CWDM4, PSM4 et plus encore<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/psm4-vs-cwdm4-which-optical-transceiver-for-your-network\/\">PSM4 contre CWDM4 : quelles sont les diff\u00e9rences ?<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/100g-single-lambda-vs-4-channel-optical-modules-comparison\/\">Diff\u00e9rences cl\u00e9s entre les modules optiques 100G \u00e0 une longueur d'onde unique et ceux \u00e0 4 longueurs d'onde<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/100g-optical-transceiver-form-factors-guide\/\">Facteurs de forme des transceivers optiques 100G : QSFP28, CFP, CFP2, CFP4 ?<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Les transceivers QSFP28 100G PSM4 offrent un Ethernet 100G haute vitesse et rentable sur fibre monomode, id\u00e9al pour les centres de donn\u00e9es et les r\u00e9seaux d'entreprise.<\/p>","protected":false},"author":1,"featured_media":5405,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13],"class_list":["post-5407","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/5407","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/comments?post=5407"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/5407\/revisions"}],"predecessor-version":[{"id":11245,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/5407\/revisions\/11245"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media\/5405"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media?parent=5407"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/categories?post=5407"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/tags?post=5407"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}