{"id":5404,"date":"2025-08-18T00:00:00","date_gmt":"2025-08-18T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/100g-cwdm4-transceiver-efficient-2km-links\/"},"modified":"2026-06-22T08:20:53","modified_gmt":"2026-06-22T08:20:53","slug":"100g-cwdm4-transceiver-efficient-2km-links","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/100g-cwdm4-transceiver-efficient-2km-links","title":{"rendered":"Le guide ultime des transceivers optiques 100G CWDM4 : pour des liaisons efficaces sur 2 km"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/399a4813f35e44f1b8d94329c2d95052.webp\" alt=\"100G CWDM4 Transceiver\" class=\"wp-image-5402\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/399a4813f35e44f1b8d94329c2d95052.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/399a4813f35e44f1b8d94329c2d95052-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/399a4813f35e44f1b8d94329c2d95052-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/399a4813f35e44f1b8d94329c2d95052-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/399a4813f35e44f1b8d94329c2d95052-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472577.htm\"><strong>Transceivers optiques 100G CWDM4<\/strong><\/a> constituent la solution standard de l\u2019industrie pour des connexions Ethernet 100 Gigabit \u00e0 haut rendement et rentables sur des distances allant jusqu\u2019\u00e0 2 kilom\u00e8tres. En exploitant la technologie <strong>Multiplexage par r\u00e9partition en longueurs d\u2019onde grossi\u00e8re <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/what-is-cwdm-understanding-coarse-wavelength-division-multiplexing\/\"><strong>(CWDM)<\/strong><\/a> sur fibre duplex <strong>. Que vous soyez connect\u00e9s aux b\u00e2timents campus, \u00e9tablissement de liens m\u00e9tro ou mise en \u0153uvre de DCI, comprendre les capacit\u00e9s et les meilleures pratiques de d\u00e9ploiement est cl\u00e9 pour le succ\u00e8s. <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/what-is-single-mode-fiber-and-how-does-it-work\/\"><strong>(SMF)<\/strong><\/a>, ils offrent des avantages significatifs pour les interconnexions de centres de donn\u00e9es (DCI), les r\u00e9seaux d\u2019entreprise et les r\u00e9seaux des fournisseurs de services. Ce guide analyse en profondeur leur fonctionnement, leurs principaux avantages et pourquoi le choix d\u2019une marque fiable telle que <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/page\/aboutus.htm\"><strong>LIEN-PP<\/strong><\/a> est essentiel pour votre infrastructure optique.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La demande incessante de bande passante dans les centres de donn\u00e9es et les r\u00e9seaux modernes exige des solutions de connectivit\u00e9 robustes, \u00e9volutives et \u00e9conomiques. Voici donc le module <strong>transceiver optique 100G CWDM4 (100G QSFP28 CWDM4)<\/strong> \u2014 une technologie fondamentale pour les liaisons 100 Gbps s\u2019\u00e9tendant sur jusqu\u2019\u00e0 2 km. D\u00e9couvrons pourquoi ce choix s\u2019est impos\u00e9.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Comprendre la technologie 100G CWDM4<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Contrairement aux solutions d\u2019optique parall\u00e8le n\u00e9cessitant plusieurs fibres (comme SR4), <strong>CWDM4<\/strong> exploite la technologie <strong>multiplexage par division de longueur d'onde <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/cwdm-vs-dwdm-vs-mwdm-vs-lwdm-vs-swdm-differences\/\"><strong>(WDM)<\/strong><\/a>. Elle combine quatre voies optiques distinctes de 25 Gbps sur seulement deux brins de fibre monomode (un pour l\u2019\u00e9mission, un pour la r\u00e9ception). Cela est r\u00e9alis\u00e9 \u00e0 l\u2019aide de quatre longueurs d\u2019onde CWDM situ\u00e9es dans la bande O :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Voie 1 :<\/strong> 1271 nm<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Voie 2 :<\/strong> 1291 nm<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Voie 3 :<\/strong> 1311 nm<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Voie 4 :<\/strong> 1331 nm<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">A <strong>(Mux)<\/strong> combine ces signaux \u00e0 l\u2019extr\u00e9mit\u00e9 \u00e9mettrice, tandis qu\u2019un <strong>d\u00e9multiplexeur (Demux)<\/strong> les s\u00e9pare \u00e0 l\u2019extr\u00e9mit\u00e9 r\u00e9ceptrice. Cette utilisation efficace de l\u2019infrastructure en fibre r\u00e9duit consid\u00e9rablement la complexit\u00e9 et le co\u00fbt du c\u00e2blage par rapport aux solutions multi-fibre, notamment dans les environnements denses.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Principales applications des modules 100G CWDM4<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Interconnexions de centres de donn\u00e9es (DCI) :<br><\/strong> Connexion des serveurs, des commutateurs \u00ab top-of-rack \u00bb (ToR) et des commutateurs d\u2019agr\u00e9gation au sein et entre les b\u00e2timents ou les campus de centres de donn\u00e9es (dans la plage des 2 km).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>R\u00e9seaux dorsaux d\u2019entreprise :<\/strong> Liaisons haute vitesse entre commutateurs c\u0153ur et routeurs dans les grands r\u00e9seaux d\u2019entreprise.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>R\u00e9seaux t\u00e9l\u00e9coms et fournisseurs de services :<\/strong> Fourniture d\u2019interfaces clientes 100G pour les applications d\u2019acc\u00e8s m\u00e9tropolitain et de bordure r\u00e9seau.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Virtualisation des fonctions r\u00e9seau (NFV) et r\u00e9seaux de stockage (SAN) :<\/strong> Prise en charge de services virtualis\u00e9s \u00e0 large bande passante et de la connectivit\u00e9 de stockage.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Principaux avantages du transceiver 100G CWDM4<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p style=\"margin: 0px;\"><strong>Efficacit\u00e9 \u00e9conomique (CAPEX et OPEX) :<\/strong> R\u00e9duit le nombre de brins de fibre de 75% par rapport \u00e0 SR4 (8 fibres contre 2 fibres), ce qui abaisse les co\u00fbts des c\u00e2bles, le nombre de ports sur les panneaux de brassage et la charge de gestion. Une consommation d\u2019\u00e9nergie inf\u00e9rieure \u00e0 celle de certaines alternatives r\u00e9duit \u00e9galement les co\u00fbts op\u00e9rationnels (OpEx).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Gestion simplifi\u00e9e de la fibre :<\/strong> Les connecteurs LC duplex sont plus petits, plus faciles \u00e0 g\u00e9rer et n\u00e9cessitent moins d\u2019espace que les connecteurs MPO utilis\u00e9s dans les optiques parall\u00e8les. Cela est crucial dans les environnements \u00e0 forte densit\u00e9.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Interop\u00e9rabilit\u00e9 normalis\u00e9e :<\/strong> Le CWDM4 <a target=\"_blank\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/multi-source-agreements-optical-transceivers\/\"><strong>MSA<\/strong><\/a><strong> (Accord multiforme)<\/strong> garantit que les modules provenant de diff\u00e9rents fournisseurs (tels que <strong>LIEN-PP<\/strong>, Finisar, Intel, etc.) interop\u00e8rent parfaitement lorsqu\u2019ils sont connect\u00e9s \u00e0 des unit\u00e9s Mux\/Demux conformes.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fiabilit\u00e9 &amp; performances \u00e9prouv\u00e9es :<\/strong> Une technologie mature offrant une connectivit\u00e9 100G stable et haute performance jusqu\u2019\u00e0 2 km avec une faible <strong>les taux d'erreur binaire <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/understanding-what-is-bit-error-rate\/\"><strong>(BER)<\/strong><\/a>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>\u00c9volutivit\u00e9 :<\/strong> Facilite les mises \u00e0 niveau et extensions r\u00e9seau gr\u00e2ce \u00e0 une infrastructure en fibre simplifi\u00e9e.<\/p><\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 CWDM4 contre PSM4 : Choisir la bonne solution 100G sur 2 km<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Both <strong>CWDM4 et PSM4<\/strong> ciblent le march\u00e9 100G duplex sur fibre monomode (SMF) sur 2 km. Voici une comparaison rapide :<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Fonctionnalit\u00e9<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>100G CWDM4 (QSFP28)<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>100G PSM4 (QSFP28)<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Technologie<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>CWDM (4 longueurs d\u2019onde)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Mode simple parall\u00e8le (4 longueurs d\u2019onde identiques ~1310 nm)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Type de fibre<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>SMF (2 fibres)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>SMF (4 fibres)<\/strong> (N\u00e9cessite un connecteur MPO-12)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Les longueurs d\u2019onde<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1271, 1291, 1311, 1331 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 \u00d7 ~1310 nm<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Avantage principal<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Nombre minimal de fibres (2)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Optique simplifi\u00e9e (pas besoin de Mux\/Demux WDM <em>aux extr\u00e9mit\u00e9s<\/em>)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Inconv\u00e9nient majeur<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>N\u00e9cessite un Mux\/Demux WDM dans le trajet<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Nombre plus \u00e9lev\u00e9 de fibres (4)<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Meilleur adapt\u00e9 \u00e0<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Maximisation de l\u2019efficacit\u00e9 des fibres<\/strong>, interconnexion de centres de donn\u00e9es (DCI), nouvelles installations<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Courtes distances sur fibre monomode o\u00f9 les fibres sont abondantes, liaisons point \u00e0 point directes sans Mux\/Demux externe<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>En g\u00e9n\u00e9ral, le CWDM4 est privil\u00e9gi\u00e9 pour ses \u00e9conomies de fibres sup\u00e9rieures,<\/strong> tandis que le PSM4 peut \u00eatre choisi pour des liaisons directes tr\u00e8s simples o\u00f9 l\u2019\u00e9vitement des unit\u00e9s Mux\/Demux externes constitue une priorit\u00e9 (bien qu\u2019il n\u00e9cessite 4 fibres).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Pourquoi la qualit\u00e9 et la compatibilit\u00e9 comptent : L\u2019avantage LINK-PP<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a1e502803bbc4cd58da53b9188a63d44.webp\" alt=\"100G QSFP28 CWDM4 Transceiver\" class=\"wp-image-5403\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a1e502803bbc4cd58da53b9188a63d44.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a1e502803bbc4cd58da53b9188a63d44-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a1e502803bbc4cd58da53b9188a63d44-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a1e502803bbc4cd58da53b9188a63d44-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a1e502803bbc4cd58da53b9188a63d44-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Tous les transceivers ne se valent pas. L\u2019utilisation de modules, <strong>modules conformes aux MSA<\/strong> de haute qualit\u00e9 est essentielle pour la stabilit\u00e9, les performances et la long\u00e9vit\u00e9 du r\u00e9seau. <strong>LIEN-PP<\/strong> fabrique des modules <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472577.htm\"><strong>100G QSFP28 CWDM4 rigoureusement test\u00e9s<\/strong><\/a> qui garantissent :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Chaque module fait l\u2019objet de tests approfondis afin d\u2019assurer des performances et une fiabilit\u00e9 sup\u00e9rieures.<\/strong> Interop\u00e9rabilit\u00e9 garantie avec les principales marques de commutateurs\/routeurs (Cisco, Juniper, Arista, Mellanox\/NVIDIA, etc.).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Performances exceptionnelles :<\/strong> Faible consommation \u00e9nerg\u00e9tique (&lt; 3,5 W en g\u00e9n\u00e9ral), excellente sensibilit\u00e9 et conformit\u00e9 aux normes IEEE 802.3bm pour des performances fiables 100GBASE-LR4 sur 2 km de fibre monomode (SMF).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Contr\u00f4le qualit\u00e9 strict :<\/strong> Chaque module fait l\u2019objet de tests approfondis portant sur la puissance optique, la sensibilit\u00e9 du r\u00e9cepteur et le taux d\u2019erreur binaire (BER).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>\u00c9conomies de co\u00fbts :<\/strong> <strong>LIEN-PP<\/strong> propose des composants optiques hautement fiables \u00e0 des prix comp\u00e9titifs, offrant une excellente alternative aux modules OEM souvent surcharg\u00e9s, sans compromis sur la qualit\u00e9.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Assistance compl\u00e8te :<\/strong> Soutenu par une expertise technique reconnue et des garanties fiables.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\ud83d\udca1 Astuce professionnelle :<\/strong> V\u00e9rifiez la compatibilit\u00e9 en consultant la liste des transceivers pris en charge par votre commutateur\/routeur (souvent appel\u00e9e MSA ou matrice de compatibilit\u00e9 optique). <strong>LIEN-PP<\/strong> fournit des informations de compatibilit\u00e9 pour ses modules, comme le tr\u00e8s populaire <strong>LIEN-PP <\/strong><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472577.htm\"><strong>LQ-CW100-FR4C<\/strong><\/a> .<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pr\u00eat \u00e0 simplifier vos liaisons 100 G sur 2 km ?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>Transceiver optique 100G CWDM4<\/strong> reste une solution dominante et tr\u00e8s efficace pour la connectivit\u00e9 Ethernet 100 Gigabit dans les centres de donn\u00e9es et jusqu\u2019\u00e0 2 km. Sa combinaison de <strong>performances, efficacit\u00e9 sur la fibre, \u00e9conomies de co\u00fbts et normalisation<\/strong> en fait un choix particuli\u00e8rement convaincant.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Optimisez d\u00e8s aujourd\u2019hui votre infrastructure r\u00e9seau ! D\u00e9couvrez la gamme LINK-PP de transceivers 100G CWDM4 haute qualit\u00e9 et compatibles, notamment le mod\u00e8le fiable LQ-CW100-FR4C. <\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\ud83d\udc49\ud83c\udffb <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/file\/datasheet\/lq-cw100-fr4c.pdf\"><strong>Fiche technique (PDF)<\/strong><\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\ud83d\udc49\ud83c\udffb <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/message-472577.htm\"><strong>Demandez un devis<\/strong><\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Questions fr\u00e9quemment pos\u00e9es (FAQ)<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Q : Quelle est la distance maximale pour le CWDM4 \u00e0 100 G ?<\/strong><br\/><strong>A:<\/strong> La norme sp\u00e9cifie un fonctionnement jusqu\u2019\u00e0 <strong>2 kilom\u00e8tres<\/strong> sur fibre monomode G.652.D.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Q : Ai-je besoin de filtres sp\u00e9ciaux ou de multiplexeurs\/d\u00e9multiplexeurs (Mux\/Demux) pour le CWDM4 ?<\/strong><br\/><strong>R : Oui.<\/strong> Les transceivers CWDM4 n\u00e9cessitent l\u2019installation, dans le trajet de la fibre entre les deux extr\u00e9mit\u00e9s, d\u2019unit\u00e9s passives de multiplexage et de d\u00e9multiplexage CWDM afin de combiner et de s\u00e9parer les longueurs d\u2019onde. Il s\u2019agit de composants passifs distincts.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Q : Les modules CWDM4 peuvent-ils fonctionner avec la technologie BiDi ?<\/strong><br\/><strong>A:<\/strong> Non. Le CWDM4 standard utilise deux fibres (Tx et Rx). Des solutions BiDi \u00e0 100 G (telles que les QSFP28 BiDi) existent, mais elles utilisent des longueurs d\u2019onde diff\u00e9rentes sur une paire de fibres pour des port\u00e9es potentiellement plus longues (par exemple, 10 km, 20 km, 40 km). <em>seul<\/em> fibre paire pour des port\u00e9es potentiellement plus longues (par exemple, 10 km, 20 km, 40 km).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Q : Le CWDM4 est-il \u00ab hot-pluggable \u00bb ?<\/strong><br\/><strong>A:<\/strong> Oui, comme la plupart des modules QSFP28, les transceivers CWDM4 sont con\u00e7us pour \u00eatre \u00ab hot-pluggables \u00bb, ce qui permet leur installation et leur retrait sans couper l\u2019alimentation de l\u2019\u00e9quipement h\u00f4te.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Q : Pourquoi choisir les modules CWDM4 LINK-PP ?<\/strong><br\/><strong>R : LINK-PP<\/strong> propose <strong>Optiques CWDM4 \u00e0 100 G hautes performances, fiables et conformes \u00e0 la norme MSA<\/strong> soutenues par des garanties de qualit\u00e9 et des \u00e9conomies substantielles par rapport aux options OEM, ce qui en fait un choix judicieux pour l\u2019extension de votre r\u00e9seau optique.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>Voir aussi<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/100g-qsfp28-optical-transceivers-selection-guide\/\">Explorer les modules optiques 100G QSFP28 : SR4, LR4, CWDM4, PSM4 et plus encore<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/psm4-vs-cwdm4-which-optical-transceiver-for-your-network\/\">PSM4 vs. CWDM4 : Quelles sont les diff\u00e9rences ?<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/100g-single-lambda-vs-4-channel-optical-modules-comparison\/\">Diff\u00e9rences cl\u00e9s entre les modules optiques 100G \u00e0 une longueur d'onde unique et ceux \u00e0 4 longueurs d'onde<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/100g-optical-transceiver-form-factors-guide\/\">Facteurs de forme des transceivers optiques 100G : QSFP28, CFP, CFP2, CFP4 ?<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Le transceiver QSFP28 100G CWDM4 est la solution standard du secteur pour des connexions Ethernet Gigabit \u00e0 haut d\u00e9bit et \u00e0 faible co\u00fbt sur des distances allant jusqu\u2019\u00e0 2 km <\/p>","protected":false},"author":1,"featured_media":5402,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13],"class_list":["post-5404","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/5404","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/comments?post=5404"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/5404\/revisions"}],"predecessor-version":[{"id":11244,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/5404\/revisions\/11244"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media\/5402"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media?parent=5404"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/categories?post=5404"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/tags?post=5404"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}