{"id":4737,"date":"2025-10-13T11:12:00","date_gmt":"2025-10-13T11:12:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/power-consumption-optimization-optical-edge-computing\/"},"modified":"2026-06-22T06:25:28","modified_gmt":"2026-06-22T06:25:28","slug":"power-consumption-optimization-optical-edge-computing","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/power-consumption-optimization-optical-edge-computing","title":{"rendered":"L\u2019optimisation de la consommation \u00e9lectrique des \u00e9metteurs-r\u00e9cepteurs optiques devient critique pour les d\u00e9ploiements informatiques p\u00e9riph\u00e9riques (edge computing)"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/23bb1b935c9543cab796e86c85a79fa9.webp\" alt=\"Optimisation de la consommation \u00e9nerg\u00e9tique des \u00e9metteurs-r\u00e9cepteurs optiques pour l&#039;informatique en p\u00e9riph\u00e9rie\" class=\"wp-image-4735\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/23bb1b935c9543cab796e86c85a79fa9.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/23bb1b935c9543cab796e86c85a79fa9-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/23bb1b935c9543cab796e86c85a79fa9-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/23bb1b935c9543cab796e86c85a79fa9-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/23bb1b935c9543cab796e86c85a79fa9-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Le monde num\u00e9rique se d\u00e9place vers la p\u00e9riph\u00e9rie. Des usines intelligentes aux v\u00e9hicules autonomes, en passant par l'analyse vid\u00e9o en temps r\u00e9el et les exp\u00e9riences de r\u00e9alit\u00e9 augment\u00e9e (RA) et de r\u00e9alit\u00e9 virtuelle (RV), le traitement \u00e0 faible latence n'est plus un luxe, mais une n\u00e9cessit\u00e9. Cette transition massive vers <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/modules-optiques-calcul-peripherique-haute-vitesse-faible-latence-connectivite\/\"><strong>computing edge<\/strong><\/a> Le d\u00e9ploiement de ces technologies r\u00e9volutionne les secteurs d'activit\u00e9, mais il met \u00e9galement en avant un d\u00e9fi dont on parle moins : <strong>consommation d'\u00e9nergie<br><\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Si l'on se concentre souvent sur la consommation \u00e9lectrique des serveurs et des commutateurs, un \u00e9l\u00e9ment essentiel, mais souvent n\u00e9glig\u00e9, est le modeste <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>\u00e9metteur-r\u00e9cepteur optique<\/strong><\/a>. Dans un centre de donn\u00e9es centralis\u00e9, les quelques watts consomm\u00e9s par un \u00e9metteur-r\u00e9cepteur peuvent sembler n\u00e9gligeables. Mais en p\u00e9riph\u00e9rie, o\u00f9 des milliers de sites compacts peuvent disposer de ressources limit\u00e9es en mati\u00e8re de refroidissement et d'alimentation \u00e9lectrique, la consommation \u00e9nerg\u00e9tique cumul\u00e9e de ces minuscules appareils devient un enjeu majeur.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cet article explique en d\u00e9tail pourquoi l'optimisation de la consommation \u00e9nerg\u00e9tique des \u00e9metteurs-r\u00e9cepteurs optiques n'est plus une consid\u00e9ration secondaire, mais une exigence fondamentale pour la mise en place de r\u00e9seaux p\u00e9riph\u00e9riques performants, durables et \u00e9volutifs.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Le dilemme de l'alimentation \u00e0 la p\u00e9riph\u00e9rie<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Les centres de donn\u00e9es cloud traditionnels sont con\u00e7us pour offrir une densit\u00e9 de puissance \u00e9lev\u00e9e et un refroidissement efficace. Ce n'est pas le cas des sites en p\u00e9riph\u00e9rie. Il peut s'agir d'armoires exigu\u00ebs install\u00e9es dans une usine, de caissons situ\u00e9s en bord de route, voire au sommet d'une antenne-relais. Ces environnements sont soumis \u00e0 des contraintes s\u00e9v\u00e8res :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Budgets \u00e9nerg\u00e9tiques limit\u00e9s :<\/strong> De nombreux sites s'appuient sur une alimentation \u00e9lectrique locale, voire parfois sur des batteries de secours. Chaque watt \u00e9conomis\u00e9 prolonge la dur\u00e9e de vie op\u00e9rationnelle et r\u00e9duit les co\u00fbts.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>D\u00e9fis li\u00e9s \u00e0 la gestion thermique :<\/strong> Un refroidissement passif ou minimal est la norme. Les composants \u00e0 forte puissance g\u00e9n\u00e8rent une chaleur excessive, ce qui entra\u00eene des pannes mat\u00e9rielles pr\u00e9matur\u00e9es et des probl\u00e8mes de fiabilit\u00e9.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>L'acc\u00e8s \u00e0 l'\u00e9nergie et les budgets sont restreints.<\/strong> Dans un espace physique restreint, une densit\u00e9 de puissance \u00e9lev\u00e9e entra\u00eene une forte concentration de chaleur.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Dans ce contexte, la recherche de <strong>infrastructure r\u00e9seau \u00e9conome en \u00e9nergie<\/strong> devient un facteur d\u00e9terminant du co\u00fbt total de possession (TCO) et de la fiabilit\u00e9.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Pourquoi les \u00e9metteurs-r\u00e9cepteurs optiques constituent un axe prioritaire<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>\u00e9metteurs-r\u00e9cepteurs optiques<\/strong><\/a> sont les \u00e9l\u00e9ments essentiels de votre r\u00e9seau, assurant la conversion des signaux \u00e9lectriques en lumi\u00e8re et inversement. Dans un d\u00e9ploiement de p\u00e9riph\u00e9rie \u00e0 grande \u00e9chelle, vous pouvez en compter des centaines, voire des milliers. Alors qu\u2019un seul \u00e9metteur-r\u00e9cepteur haute performance peut consommer 3 \u00e0 4 W, un groupe de ces appareils dans un m\u00eame commutateur peut facilement consommer entre 50 et 100 W, ce qui repr\u00e9sente une charge importante pour un site de p\u00e9riph\u00e9rie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La n\u00e9cessit\u00e9 de <strong>efficacit\u00e9 \u00e9nerg\u00e9tique dans l'informatique en p\u00e9riph\u00e9rie<\/strong> Cela signifie que chaque composant doit \u00eatre examin\u00e9 minutieusement. <strong>Optimisation de la consommation \u00e9lectrique des \u00e9metteurs-r\u00e9cepteurs optiques<\/strong> contribue directement \u00e0 :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>R\u00e9duction des d\u00e9penses d'exploitation (OpEx) :<\/strong> La r\u00e9duction de la consommation \u00e9lectrique permet de diminuer les factures d'\u00e9lectricit\u00e9 sur des milliers de sites.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Une fiabilit\u00e9 accrue :<\/strong> Les \u00e9metteurs-r\u00e9cepteurs qui fonctionnent \u00e0 une temp\u00e9rature plus basse ont une dur\u00e9e de vie plus longue et un temps moyen entre pannes (MTBF) plus \u00e9lev\u00e9.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Am\u00e9lioration de la durabilit\u00e9 :<\/strong> Une consommation d'\u00e9nergie r\u00e9duite permet de diminuer l'empreinte carbone de votre r\u00e9seau p\u00e9riph\u00e9rique.<\/p><\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a314b7742b4b402a875906acc2e114cd.webp\" alt=\"\u00e9metteur-r\u00e9cepteur optique\" class=\"wp-image-4736\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a314b7742b4b402a875906acc2e114cd.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a314b7742b4b402a875906acc2e114cd-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a314b7742b4b402a875906acc2e114cd-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a314b7742b4b402a875906acc2e114cd-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a314b7742b4b402a875906acc2e114cd-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Comment choisir un \u00e9metteur-r\u00e9cepteur optique \u00e9conome en \u00e9nergie pour votre d\u00e9ploiement en p\u00e9riph\u00e9rie<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Tous les \u00e9metteurs-r\u00e9cepteurs ne se valent pas. Lorsque vous choisissez des \u00e9metteurs-r\u00e9cepteurs pour des applications en p\u00e9riph\u00e9rie sensibles \u00e0 la consommation d'\u00e9nergie, tenez compte de ces facteurs cl\u00e9s, qui sont au c\u0153ur de toute strat\u00e9gie visant \u00e0 <strong>optimisation de la consommation \u00e9lectrique du r\u00e9seau<\/strong>.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Fonctionnalit\u00e9<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Sp\u00e9cifications cl\u00e9s des \u00e9metteurs-r\u00e9cepteurs conformes au DMD :<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u00c9metteur-r\u00e9cepteur \u00e0 consommation optimis\u00e9e (par exemple, LINK-PP)<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Avantages de l'Edge Computing<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Consommation d\u2019\u00e9nergie<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Plus \u00e9lev\u00e9 (par exemple, 3,5 W et plus)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Plus faible (par exemple, &lt; 2,5 W)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>R\u00e9duit directement<\/strong> la charge \u00e9lectrique totale et la production de chaleur sur le site.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Temp\u00e9rature de fonctionnement<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Standard (de 0 \u00b0C \u00e0 70 \u00b0C)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Plage \u00e9tendue (par exemple, de -40 \u00b0C \u00e0 85 \u00b0C)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Offre une plus grande fiabilit\u00e9 dans les environnements p\u00e9riph\u00e9riques difficiles et non climatis\u00e9s.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Conformit\u00e9 et conception<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Peut utiliser des composants plus anciens et moins performants<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Con\u00e7u \u00e0 partir de processeurs DSP de pointe \u00e0 faible consommation et de composants optiques<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Con\u00e7u d\u00e8s le d\u00e9part pour <strong>transmission de donn\u00e9es \u00e9conome en \u00e9nergie<\/strong>.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Gestion et diagnostics<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Basique <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/ddm-dom-in-optical-transceivers\/\"><strong>DDM\/DOM<\/strong><\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Suivi avanc\u00e9 et d\u00e9taill\u00e9 de la consommation \u00e9lectrique<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Permet un suivi et une gestion pr\u00e9cis de la consommation \u00e9lectrique sur l'ensemble du r\u00e9seau.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Comme le montre le tableau, un \u00e9metteur-r\u00e9cepteur sp\u00e9cialement con\u00e7u et optimis\u00e9 sur le plan \u00e9nerg\u00e9tique ne constitue pas une simple am\u00e9lioration mineure, mais un \u00e9l\u00e9ment essentiel \u00e0 la mise en place de r\u00e9seaux p\u00e9riph\u00e9riques robustes.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 LINK-PP : l'efficacit\u00e9 technique pour la p\u00e9riph\u00e9rie<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c0 la pointe de cette nouvelle tendance, on trouve des fabricants qui privil\u00e9gient l'efficacit\u00e9 sans pour autant faire de compromis sur les performances. C'est l\u00e0 qu'intervient une marque comme <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.link-pp.com\/\"><strong>LIEN-PP<\/strong><\/a> se d\u00e9marque. L'entreprise a con\u00e7u ses \u00e9metteurs-r\u00e9cepteurs sp\u00e9cialement pour r\u00e9pondre aux d\u00e9fis pos\u00e9s par le calcul distribu\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Le module<br><\/strong> Cette approche ne se limite pas \u00e0 l'utilisation de composants \u00e0 faible consommation. Elle met l'accent sur <strong>conception thermique et \u00e9nerg\u00e9tique au niveau du syst\u00e8me<\/strong>, garantissant ainsi que leurs \u00e9metteurs-r\u00e9cepteurs pr\u00e9servent l'int\u00e9grit\u00e9 du signal tout en fonctionnant \u00e0 des temp\u00e9ratures nettement inf\u00e9rieures aux moyennes du secteur. Un excellent exemple de cette philosophie d'ing\u00e9nierie est leur <strong>LIEN-PP <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>Module optique QSFP28 100G<\/strong><\/a> s\u00e9rie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Par exemple, le <strong>LIEN-PP <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473115.htm\"><strong>LQ-M85100-SR4C<\/strong><\/a> Cet \u00e9metteur-r\u00e9cepteur est un mod\u00e8le d'exception con\u00e7u pour les commutateurs d'agr\u00e9gation de p\u00e9riph\u00e9rie 100G. Il consomme moins de 2,2 W, ce qui repr\u00e9sente une \u00e9conomie consid\u00e9rable par rapport aux alternatives g\u00e9n\u00e9riques. En optant pour un mod\u00e8le sp\u00e9cifique et optimis\u00e9 sur le plan \u00e9nerg\u00e9tique comme celui-ci, les architectes r\u00e9seau peuvent s'attaquer directement aux principaux d\u00e9fis li\u00e9s \u00e0 <strong>les contraintes li\u00e9es \u00e0 la dissipation thermique et au budget \u00e9nerg\u00e9tique dans les centres de donn\u00e9es en p\u00e9riph\u00e9rie<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019int\u00e9gration de <strong>LIEN-PP<\/strong>\u2018Les solutions propos\u00e9es constituent une r\u00e9ponse concr\u00e8te \u00e0 la question de <strong>Comment r\u00e9duire la dissipation thermique dans les centres de donn\u00e9es p\u00e9riph\u00e9riques<\/strong>, ce qui rend votre d\u00e9ploiement plus r\u00e9silient et plus rentable d\u00e8s le d\u00e9part.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 L'avenir, c'est l'efficacit\u00e9<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le d\u00e9veloppement de la p\u00e9riph\u00e9rie s'appuiera sur des principes durables et pratiques. Ne pas tenir compte de l'empreinte \u00e9nerg\u00e9tique des composants r\u00e9seau tels que <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>\u00e9metteurs-r\u00e9cepteurs optiques<\/strong><\/a> est une erreur co\u00fbteuse. En donnant la priorit\u00e9 \u00e0 l'optimisation de la consommation d'\u00e9nergie et en s'associant \u00e0 des innovateurs qui ma\u00eetrisent les principes physiques de l'edge computing, comme <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.link-pp.com\/\"><strong>LIEN-PP<\/strong><\/a>, les entreprises peuvent mettre en place des r\u00e9seaux qui sont non seulement tr\u00e8s performants, mais aussi l\u00e9gers, fiables et par\u00e9s pour l'avenir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 FAQ<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Quelle est la meilleure fa\u00e7on de r\u00e9duire la consommation d'\u00e9nergie des \u00e9metteurs-r\u00e9cepteurs optiques en p\u00e9riph\u00e9rie ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Vous devriez choisir des modules optiques \u00e0 faible consommation d'\u00e9nergie et les installer \u00e0 proximit\u00e9 de l'endroit o\u00f9 vous traitez les donn\u00e9es. Cela permet de raccourcir le chemin parcouru par les donn\u00e9es et d'\u00e9conomiser de l'\u00e9nergie. V\u00e9rifiez toujours la puissance nominale de vos modules avant de les acheter.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Comment surveillez-vous la consommation \u00e9lectrique dans les r\u00e9seaux p\u00e9riph\u00e9riques ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Installez des capteurs et utilisez des outils logiciels pour surveiller la consommation \u00e9lectrique et la temp\u00e9rature. Consultez r\u00e9guli\u00e8rement vos donn\u00e9es. Si vous constatez des valeurs \u00e9lev\u00e9es, intervenez rapidement pour r\u00e9soudre le probl\u00e8me.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Est-il possible de moderniser d'anciens appareils p\u00e9riph\u00e9riques afin de r\u00e9aliser des \u00e9conomies d'\u00e9nergie ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Oui ! Vous pouvez remplacer vos anciens modules optiques par des mod\u00e8les plus r\u00e9cents et plus \u00e9conomes en \u00e9nergie. V\u00e9rifiez si vos appareils prennent en charge ces nouveaux modules. Cette mise \u00e0 niveau vous permettra de r\u00e9duire votre consommation d'\u00e9nergie et d'am\u00e9liorer les performances.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Pourquoi la temp\u00e9rature est-elle importante pour les \u00e9metteurs-r\u00e9cepteurs optiques ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les temp\u00e9ratures \u00e9lev\u00e9es entra\u00eenent une consommation d'\u00e9nergie accrue des \u00e9metteurs-r\u00e9cepteurs et nuisent \u00e0 leur bon fonctionnement. Veillez \u00e0 refroidir vos appareils \u00e0 l'aide de ventilateurs ou de dissipateurs thermiques. Une bonne circulation de l'air contribue \u00e0 la s\u00e9curit\u00e9 et \u00e0 l'efficacit\u00e9 de votre r\u00e9seau.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Quels outils vous aident \u00e0 \u00e9valuer la consommation d'\u00e9nergie avant de mettre en place votre r\u00e9seau ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les outils de simulation tels que MintEDGE vous permettent de mod\u00e9liser votre r\u00e9seau. Vous pouvez tester diff\u00e9rentes configurations et \u00e9valuer la consommation \u00e9lectrique de chacune d'entre elles. Cela vous aide \u00e0 d\u00e9finir la meilleure conception possible.<\/p>","protected":false},"excerpt":{"rendered":"<p>L\u2019optimisation de la consommation \u00e9lectrique des \u00e9metteurs-r\u00e9cepteurs optiques dans l\u2019informatique p\u00e9riph\u00e9rique (edge computing) r\u00e9duit la consommation d\u2019\u00e9nergie, abaisse les co\u00fbts et am\u00e9liore l\u2019\u00e9volutivit\u00e9 et la fiabilit\u00e9 du r\u00e9seau.<\/p>","protected":false},"author":1,"featured_media":4735,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13,17,24,26],"class_list":["post-4737","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules","tag-400g-optical-modules","tag-link-pp","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/4737","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/comments?post=4737"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/4737\/revisions"}],"predecessor-version":[{"id":11023,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/4737\/revisions\/11023"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media\/4735"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media?parent=4737"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/categories?post=4737"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/tags?post=4737"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}