{"id":3818,"date":"2025-09-03T00:00:00","date_gmt":"2025-09-03T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/glossary\/mode-conditioning-patch-cables-how-they-work-in-networks\/"},"modified":"2026-06-22T07:47:30","modified_gmt":"2026-06-22T07:47:30","slug":"mode-conditioning-patch-cables-how-they-work-in-networks","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/mode-conditioning-patch-cables-how-they-work-in-networks","title":{"rendered":"Qu\u2019est-ce qu\u2019un c\u00e2ble de conditionnement de mode et comment fonctionne-t-il\u202f?"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f.webp\" alt=\"What Are Mode Conditioning Patch Cables\" class=\"wp-image-3815\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Avez-vous d\u00e9j\u00e0 d\u00e9ploy\u00e9 un transceiver optique Gigabit LX ou 10G LR et \u00e9t\u00e9 confront\u00e9 \u00e0 des erreurs inattendues, \u00e0 une forte att\u00e9nuation ou \u00e0 des liaisons instables\u202f? Le coupable pourrait ne pas \u00eatre votre \u00e9quipement, mais un d\u00e9saccord fondamental entre les types de c\u00e2bles en fibre optique utilis\u00e9s. C\u2019est ici qu\u2019intervient un petit h\u00e9ros puissant\u202f: le <strong>c\u00e2ble de conditionnement de mode (MCP)<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dans ce guide, nous d\u00e9mystifierons <strong>ce qu\u2019est un c\u00e2ble de conditionnement de mode,<\/strong>, pourquoi il est essentiel dans certains sc\u00e9narios r\u00e9seau, et comment il peut vous \u00e9pargner bien des maux de t\u00eate li\u00e9s \u00e0 la connectivit\u00e9. Nous examinerons \u00e9galement comment il interagit avec des composants haute performance tels que <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>\u00e9metteurs-r\u00e9cepteurs optiques LINK-PP<\/strong><\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Points cl\u00e9s \u00e0 retenir<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Les c\u00e2bles de conditionnement de mode<\/strong> permettent aux dispositifs monomodes d\u2019utiliser des fibres multimodes. Ils corrigent des probl\u00e8mes de signal tels que le d\u00e9lai diff\u00e9rentiel de mode.<\/p><\/li><li><p>Ces c\u00e2bles am\u00e9liorent le signal et r\u00e9duisent les erreurs. Cela permet aux r\u00e9seaux de fonctionner plus rapidement et de fa\u00e7on plus fiable, notamment pour l\u2019Ethernet Gigabit.<\/p><\/li><li><p>Ces c\u00e2bles comportent une partie sp\u00e9ciale dot\u00e9e d\u2019une section monomode. Cette partie d\u00e9place le signal lumineux afin de r\u00e9duire la distorsion et d\u2019am\u00e9liorer le transfert des donn\u00e9es.<\/p><\/li><li><p>Branchez toujours l\u2019extr\u00e9mit\u00e9 monomode sur le transceiver. Branchez l\u2019extr\u00e9mit\u00e9 multimode sur l\u2019installation en fibre pour \u00e9viter les probl\u00e8mes r\u00e9seau.<\/p><\/li><li><p>Nettoyez les connecteurs avant utilisation. N\u2019enroulez pas les c\u00e2bles brusquement. Testez la connexion apr\u00e8s installation pour maintenir la robustesse du r\u00e9seau.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Pourquoi avons-nous besoin d\u2019un \u201c\u202fc\u00e2ble sp\u00e9cial\u202f\u201d\u202f? Le probl\u00e8me multimode vs. monomode<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Pour comprendre la solution, nous devons d\u2019abord saisir le probl\u00e8me. Les c\u00e2bles en fibre optique existent principalement en deux types\u202f:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/om1-om2-om3-om4-om5-multimode-fiber-guide\/\"><strong>Fibre multimode (MMF)<\/strong><\/a><strong>:<\/strong> Il poss\u00e8de un c\u0153ur plus large, autorisant le passage de plusieurs modes lumineux (chemins). Il est con\u00e7u pour des applications \u00e0 courte distance et haut d\u00e9bit au sein des b\u00e2timents ou des campus. Les types courants sont <strong>OM1, OM2, OM3 et OM4<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/what-is-single-mode-fiber-and-how-does-it-work\/\"><strong>Fibre monomode (SMF)<\/strong><\/a><strong>:<\/strong> Elle poss\u00e8de un c\u0153ur nettement plus petit, autorisant le passage d\u2019un seul mode lumineux en ligne droite. Elle est con\u00e7ue pour les communications longue distance, par exemple entre villes.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Le probl\u00e8me survient lorsque vous essayez de connecter un <strong>transceiver longue port\u00e9e (LX\/LR)<\/strong> (con\u00e7u pour la SMF) \u00e0 une <strong>Fibre multimode (MMF)<\/strong> installation en fibre multimode (MMF). Cela est fr\u00e9quent dans les b\u00e2timents anciens c\u00e2bl\u00e9s en MMF qui doivent se connecter \u00e0 un nouveau backbone en SMF.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La lumi\u00e8re laser \u00e9mise par le transceiver LX\/LR p\u00e9n\u00e8tre dans le grand c\u0153ur de la MMF. Cela peut provoquer un ph\u00e9nom\u00e8ne appel\u00e9 <strong>d\u00e9lai diff\u00e9rentiel de mode (DMD)<\/strong>, o\u00f9 les impulsions lumineuses s\u2019\u00e9talent et se d\u00e9forment pendant leur propagation, entra\u00eenant des gigue, des erreurs et m\u00eame une d\u00e9faillance totale de la liaison. Ce probl\u00e8me est particuli\u00e8rement critique avec <strong>les fibres OM3 et OM4<\/strong> and <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475586.htm\"><strong>les modules 10G LR<\/strong><\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Comment fonctionne un c\u00e2ble de conditionnement de mode\u202f?<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"318\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028.webp\" alt=\"Mode Conditioning Patch Cables\" class=\"wp-image-3816\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028-300x80.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028-1024x271.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028-768x204.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028-18x5.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">A <strong>C\u00e2ble de conditionnement de mode<\/strong> est un <strong>cordon duplex en fibre<\/strong> ing\u00e9nieusement con\u00e7u pour r\u00e9soudre cette incompatibilit\u00e9 au niveau de la couche physique. Il est parfois appel\u00e9 <em>cordon de conditionnement de mode<\/em>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Son astuce r\u00e9side dans sa construction c\u00f4t\u00e9 \u00e9mission (Tx)\u202f:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\">Une branche du c\u00e2ble est un <strong>connecteur monomode standard<\/strong> qui se branche sur votre transceiver.<\/p><\/li><li><p style=\"margin: 0px;\">L\u2019autre branche est un <strong>connecteur multimode<\/strong> dot\u00e9 d\u2019une soudure fusionn\u00e9e d\u00e9cal\u00e9e, situ\u00e9e \u00e0 quelques m\u00e8tres de l\u2019extr\u00e9mit\u00e9.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Cette conception force la lumi\u00e8re laser \u00e0 parcourir d\u2019abord une courte distance sur fibre monomode. Elle est ensuite inject\u00e9e de fa\u00e7on strat\u00e9gique dans le <strong>centre du c\u0153ur de la fibre multimode<\/strong> au point de soudure. Lorsque le signal p\u00e9n\u00e8tre dans votre installation en MMF h\u00e9rit\u00e9e, il est stabilis\u00e9, \u00e9liminant ainsi efficacement l\u2019effet DMD et permettant une transmission de donn\u00e9es propre et fiable.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Applications cl\u00e9s et cas d\u2019usage\u202f:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\">La connexion <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476763.htm\"><strong>module SFP 1000BASE-LX<\/strong><\/a> to <strong>OM1\/OM2\/OM3<br><\/strong> fibre multimode.<\/p><\/li><li><p style=\"margin: 0px;\">La connexion <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475586.htm\"><strong>modules SFP+ 10GBASE-LR<\/strong><\/a> to <strong>OM3\/OM4<\/strong> fibre multimode.<\/p><\/li><li><p style=\"margin: 0px;\">Extension de la port\u00e9e des transceivers LX\/LR sur fibre multimode au-del\u00e0 de leur distance limite typique due au DMD.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 C\u00e2ble de conditionnement de mode vs. c\u00e2ble standard\u202f: comparaison rapide<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Fonctionnalit\u00e9<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>C\u00e2ble standard<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>C\u00e2ble de conditionnement de mode<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Fonction principale<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Connecte des types de fibres identiques (SMF-SMF ou MMF-MMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Connecte des types de fibres diff\u00e9rents (transceiver SMF vers c\u00e2ble MMF)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Conception interne<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Type de fibre uniforme sur toute la longueur<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Comporte une <strong>soudure fusionn\u00e9e d\u00e9cal\u00e9e pr\u00e9cise<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Cas d\u2019utilisation<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Connexions standard, type \u00ab\u202fin\u202f\u00bb<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Mises \u00e0 niveau de r\u00e9seaux h\u00e9rit\u00e9s<\/strong>, exigences sp\u00e9cifiques li\u00e9es aux transceivers<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Emp\u00eache le DMD\u202f?<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>No<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Yes<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Cost<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lower<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>L\u00e9g\u00e8rement plus \u00e9lev\u00e9<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Int\u00e9gration avec les transceivers optiques LINK-PP pour des performances optimales<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"719\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f.jpg\" alt=\"optical transceivers\" class=\"wp-image-3817\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f-300x180.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f-1024x614.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f-768x460.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f-18x12.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Lors de la conception d\u2019un r\u00e9seau fiable et haute performance, chaque composant doit fonctionner en parfaite harmonie. L\u2019utilisation d\u2019un c\u00e2ble de conditionnement de mode de qualit\u00e9 est cruciale pour exploiter pleinement le potentiel de vos <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>transceivers optiques<\/strong><\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Par exemple, si vous utilisez un <strong>LIEN-PP <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475586.htm\"><strong>SFP-10G-LR<\/strong><\/a> module pour vous connecter \u00e0 un backbone existant en OM3 multimode, un c\u00e2ble de conditionnement de mode n\u2019est pas seulement recommand\u00e9\u202f; il est souvent obligatoire pour garantir une liaison stable. Il en va de m\u00eame pour un<strong> <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476763.htm\"><strong>SFP-1G-LX<\/strong><\/a> module sur une ancienne fibre OM1.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Astuce professionnelle\u00a0:<\/strong> Consultez toujours la fiche technique de vos <strong>transceivers compatibles LINK-PP<\/strong>. Elle indique le type de fibre requis et mentionne souvent explicitement la n\u00e9cessit\u00e9 d\u2019un c\u00e2ble de conditionnement de mode lors de la connexion \u00e0 une fibre MMF. Le d\u00e9ploiement correct de cette configuration constitue une bonne pratique pour <strong>la fiabilit\u00e9 du r\u00e9seau<\/strong> et la r\u00e9duction des <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/understanding-what-is-bit-error-rate\/\"><strong>taux d\u2019erreurs binaire (BER)<\/strong><\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 En avez-vous besoin\u202f? Points cl\u00e9s \u00e0 retenir<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Vous avez besoin d\u2019un c\u00e2ble de conditionnement de mode si\u202f:<\/strong> Vous connectez un <strong>transceiver longue port\u00e9e (LX, LR, ER)<\/strong> SFP, SFP+ ou GBIC \u00e0 une <strong>Fibre multimode (MMF)<\/strong> liaison en fibre multimode.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Vous n\u2019en avez PAS besoin si\u202f:<\/strong> Vous connectez un transceiver au type de fibre pour lequel il a \u00e9t\u00e9 con\u00e7u (par exemple, LX vers SMF, ou SX vers MMF).<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Investir dans l\u2019infrastructure de c\u00e2blage ad\u00e9quate garantit le fonctionnement efficace de votre r\u00e9seau, r\u00e9duit les temps d\u2019arr\u00eat et prot\u00e8ge votre investissement dans du mat\u00e9riel haut de gamme tel que <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>Modules optiques LINK-PP<\/strong><\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 FAQ<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Quelle est la principale fonction d\u2019un c\u00e2ble de conditionnement de mode ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un c\u00e2ble de conditionnement de mode permet aux \u00e9metteurs-r\u00e9cepteurs monomodes de fonctionner avec une fibre multimode. Il contribue \u00e0 r\u00e9duire les probl\u00e8mes de signal tels que le d\u00e9lai diff\u00e9rentiel de mode. Cela permet de maintenir un transfert de donn\u00e9es fluide dans les r\u00e9seaux \u00e0 fibres mixtes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Peut-on utiliser un c\u00e2ble de conditionnement de mode avec n\u2019importe quel syst\u00e8me \u00e0 fibre optique ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Non, ces c\u00e2bles fonctionnent au mieux lorsqu\u2019ils relient des \u00e9quipements monomodes \u00e0 une fibre multimode. Ils ne sont pas utiles dans les syst\u00e8mes utilisant uniquement de la fibre monomode ou uniquement de la fibre multimode.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Comment identifier l\u2019extr\u00e9mit\u00e9 monomode du c\u00e2ble ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La plupart des c\u00e2bles pr\u00e9sentent un bo\u00eetier jaune ou une \u00e9tiquette sur l\u2019extr\u00e9mit\u00e9 monomode. Les utilisateurs doivent toujours v\u00e9rifier ces marquages avant de raccorder le c\u00e2ble.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Que se passe-t-il si le c\u00e2ble est install\u00e9 \u00e0 l\u2019envers ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Si le c\u00e2ble est connect\u00e9 \u00e0 l\u2019envers, le r\u00e9seau peut ne pas fonctionner. Le signal peut s\u2019affaiblir ou \u00eatre perdu. Connectez toujours l\u2019extr\u00e9mit\u00e9 monomode \u00e0 l\u2019\u00e9metteur-r\u00e9cepteur.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Les c\u00e2bles de conditionnement de mode prennent-ils en charge les r\u00e9seaux haute vitesse ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Oui, ces c\u00e2bles prennent en charge des liaisons haute vitesse telles que l\u2019Ethernet Gigabit et l\u2019Ethernet 10 Gigabit. Ils aident \u00e0 maintenir des signaux clairs et puissants dans les r\u00e9seaux rapides.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Astuce : Testez toujours la liaison apr\u00e8s avoir install\u00e9 un c\u00e2ble de conditionnement de mode afin de vous assurer que la connexion fonctionne correctement.<\/p><\/blockquote>","protected":false},"excerpt":{"rendered":"<p>Les c\u00e2bles de conditionnement de mode permettent aux \u00e9quipements monomodes de fonctionner avec une fibre multimode, r\u00e9duisant ainsi la distorsion du signal et le d\u00e9lai diff\u00e9rentiel de mode dans les r\u00e9seaux.<\/p>","protected":false},"author":1,"featured_media":3815,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[27],"tags":[26],"class_list":["post-3818","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-glossary","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/3818","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/comments?post=3818"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/3818\/revisions"}],"predecessor-version":[{"id":11185,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/3818\/revisions\/11185"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media\/3815"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media?parent=3818"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/categories?post=3818"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/tags?post=3818"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}