{"id":3793,"date":"2025-11-18T00:00:00","date_gmt":"2025-11-18T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/glossary\/xlaui-10-lane-attachment-unit-interface-ethernet-explained\/"},"modified":"2026-06-22T05:00:37","modified_gmt":"2026-06-22T05:00:37","slug":"xlaui-10-lane-attachment-unit-interface-ethernet-explained","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/xlaui-10-lane-attachment-unit-interface-ethernet-explained","title":{"rendered":"Qu\u2019est-ce que XLAUI ? Explication de l\u2019interface d\u2019unit\u00e9 de raccordement \u00e0 10 voies"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/01c637791b5742329bd6f1ee40a189b2.webp\" alt=\"What Is XLAUI? 10-Lane Attachment Unit Interface Explained\" class=\"wp-image-3790\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/01c637791b5742329bd6f1ee40a189b2.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/01c637791b5742329bd6f1ee40a189b2-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/01c637791b5742329bd6f1ee40a189b2-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/01c637791b5742329bd6f1ee40a189b2-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/01c637791b5742329bd6f1ee40a189b2-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 Introduction<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Les r\u00e9seaux haute vitesse n\u00e9cessitent des interfaces \u00e9lectriques robustes et normalis\u00e9es afin d\u2019assurer des liaisons fiables de 40 Go\/s entre les ASIC h\u00f4te et les modules optiques enfichables. Une interface critique dans ce domaine est l\u2019 <strong>interface unitaire d\u2019attachement \u00e0 10 voies (XLAUI)<\/strong>, d\u00e9finie dans la norme IEEE 802.3ba. Les ing\u00e9nieurs, architectes syst\u00e8me et int\u00e9grateurs de modules d\u00e9ployant des modules QSFP+ 40G tirent profit d\u2019une compr\u00e9hension claire de la XLAUI pour garantir l\u2019interop\u00e9rabilit\u00e9, l\u2019int\u00e9grit\u00e9 du signal et des performances pr\u00e9visibles.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cet article explique ce qu\u2019est la XLAUI, son fonctionnement, son importance dans les modules QSFP+ 40G, et fournit des \u00e9clairages pratiques \u00e0 l\u2019aide de <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26153-40g-qsfp.htm\"><strong>modules QSFP+ 40G LINK-PP<\/strong><\/a> comme exemples concrets.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 Qu\u2019est-ce que la XLAUI ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>XLAUI<\/strong> signifie <strong>Interface unitaire d\u2019attachement \u00e9tendue \u00e0 10 voies<\/strong>. Il s\u2019agit d\u2019une interface \u00e9lectrique d\u00e9finie dans <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/what-is-ieee-802-3ba-standard\/\">IEEE 802.3ba<\/a> for <strong>l'Ethernet 40 Gigabit (40GbE)<\/strong>. La XLAUI est utilis\u00e9e pour des connexions <strong>puce-\u00e0-module<\/strong> or <strong>puce-\u00e0-puce<\/strong> , notamment dans les modules enfichables tels que le QSFP+.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caract\u00e9ristiques cl\u00e9s :<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Structure des voies :<\/strong> 10 voies parall\u00e8les, chacune fonctionnant \u00e0 environ 10,3125 Go\/s, permettant un d\u00e9bit de donn\u00e9es utilisateur agr\u00e9g\u00e9 d\u2019environ 40 Go\/s apr\u00e8s codage.<\/p><\/li><li><p><strong>Applications :<\/strong> Liaisons h\u00f4te-module pour backplanes optiques ou en cuivre.<\/p><\/li><li><p><strong>Normes \u00e9lectriques :<\/strong> D\u00e9finies \u00e0 l\u2019annexe 83A de la norme IEEE 802.3ba, y compris les param\u00e8tres d\u2019\u00e9metteur\/r\u00e9cepteur, les budgets de perte de canal, la perte de retour et les budgets de gigue.<\/p><\/li><li><p><strong>Relation avec d\u2019autres interfaces AUI :<\/strong> Fait partie de la famille des \u201c interfaces unitaires d\u2019attachement \u201d \u2014 comme la XAUI (10 GbE) ou la CAUI (100 GbE), mais optimis\u00e9e pour la 40 GbE.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">La XLAUI permet de ma\u00eetriser les vitesses par voie tout en atteignant une bande passante agr\u00e9g\u00e9e \u00e9lev\u00e9e, ce qui la rend pratique pour les conceptions denses de commutateurs et de serveurs.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 Comment fonctionne la XLAUI ?<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Structure des voies et d\u00e9bit de donn\u00e9es<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Chacune des 10 voies transporte environ 10,3125 Go\/s.<\/p><\/li><li><p>Apr\u00e8s codage 64b\/66b, le d\u00e9bit de donn\u00e9es utilisateur agr\u00e9g\u00e9 atteint environ 40 Go\/s.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Fonctionnement du SERDES<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Chaque voie utilise un <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/serdes-interfaces-high-speed-data-transfer-and-signal-integrity\/\"><strong>convertisseur s\u00e9rie-parall\u00e8le \/ parall\u00e8le-s\u00e9rie (SERDES)<\/strong><\/a> pour convertir les donn\u00e9es parall\u00e8les en flux s\u00e9ries et vice versa.<\/p><\/li><li><p>Les modules ou les r\u00e9timers peuvent utiliser une <strong>bo\u00eete de vitesses (gearbox)<\/strong> pour mapper 10 voies \u00e9lectriques vers un nombre r\u00e9duit de voies optiques (par exemple, un mapping 10\u21924).<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Exigences du canal<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>La norme IEEE 802.3ba sp\u00e9cifie les pertes de canal, la perte de retour, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/jitter-in-optics-causes-effects-measurement-reduction\/\">jitter<\/a>, ainsi que les limites de skew.<\/p><\/li><li><p>Exemple : perte autoris\u00e9e d\u2019environ 10 dB \u00e0 la fr\u00e9quence de Nyquist (environ 5,15625 GHz) pour des pistes typiques en FR4 de 250 mm.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Puce-\u00e0-module contre puce-\u00e0-puce<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>XLAUI est principalement une <strong>puce-\u00e0-module<\/strong> interface (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/what-is-application-specific-integrated-circuit-asic\/\">ASIC<\/a> \u2192 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491483.htm\">QSFP+<\/a>).<\/p><\/li><li><p>Peut \u00e9galement prendre en charge les interconnexions sur dos d\u2019imprim\u00e9e ou sur carte imprim\u00e9e, moyennant une gestion ad\u00e9quate de l\u2019int\u00e9grit\u00e9 du signal.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 Importance de XLAUI dans les modules QSFP+ 40G<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb.webp\" alt=\"XLAUI in 40G QSFP+ Modules\" class=\"wp-image-3342\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Densit\u00e9 de ports accrue<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Plusieurs voies \u00e9lectriques d\u2019environ 10 Gb\/s sont plus faciles \u00e0 router qu\u2019une seule voie ultra-rapide.<\/p><\/li><li><p>Permet des facteurs de forme compacts QSFP+ et des cartes lignes \u00e0 forte densit\u00e9.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Compatibilit\u00e9 normalis\u00e9e<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>La normalisation permet aux fabricants de modules et de circuits int\u00e9gr\u00e9s sp\u00e9cifiques (ASIC) (p. ex. LINK-PP) de concevoir selon une interface commune.<\/p><\/li><li><p>L\u2019interop\u00e9rabilit\u00e9 s\u2019am\u00e9liore dans les syst\u00e8mes multi-fournisseurs.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Int\u00e9grit\u00e9 du signal ma\u00eetrisable<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Des vitesses mod\u00e9r\u00e9es par voie simplifient la conception de la carte imprim\u00e9e, la mise en \u0153uvre de connecteurs enfichables \u00e0 chaud et r\u00e9duisent les besoins en r\u00e9timeurs.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >P\u00e9rennit\u00e9<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>XLAUI reste pertinent pour les modules 40G h\u00e9rit\u00e9s et les infrastructures \u00e0 d\u00e9bits mixtes, m\u00eame avec l\u2019\u00e9mergence des technologies de voies \u00e0 25G\/50G.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Modules QSFP+ 40G LINK-PP et XLAUI<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3d5106edaa294519a6049787ffac25c9.webp\" alt=\"40G QSFP+ Modules\" class=\"wp-image-3791\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3d5106edaa294519a6049787ffac25c9.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3d5106edaa294519a6049787ffac25c9-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3d5106edaa294519a6049787ffac25c9-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3d5106edaa294519a6049787ffac25c9-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3d5106edaa294519a6049787ffac25c9-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Exemple :<\/strong> LIEN\u2011PP <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491483.htm\">LQ\u2011CW40\u2011LR4C<\/a> Module QSFP+ 40G<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Convertit 4 voies \u00e9lectriques de 10 Gb\/s en 4 signaux optiques CWDM.<\/p><\/li><li><p>Compatible avec les normes d\u2019interface \u00e9lectrique IEEE 802.3ba, impl\u00e9mentant effectivement, c\u00f4t\u00e9 h\u00f4te, un fonctionnement XLAUI \u00e0 10 voies.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Cons\u00e9quences pour la conception :<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>L\u2019ASIC h\u00f4te ou le commutateur doit prendre en charge une <strong>interface XLAUI \u00e0 10 voies<\/strong>.<\/p><\/li><li><p>La conception de la carte imprim\u00e9e doit garantir l\u2019int\u00e9grit\u00e9 du signal, l\u2019alignement des voies et le contr\u00f4le de la gigue de propagation (skew).<\/p><\/li><li><p>V\u00e9rifier la compatibilit\u00e9 fournisseur concernant le respect de l\u2019interface \u00e9lectrique.<\/p><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">Les modules LINK-PP<br><\/a> se conformer aux normes IEEE, ce qui permet des performances pr\u00e9visibles et une int\u00e9gration simplifi\u00e9e dans les syst\u00e8mes 40G.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 Consid\u00e9rations de conception et bonnes pratiques<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Contr\u00f4le de la gigue de propagation (skew) entre voies :<\/strong> Veiller \u00e0 ce que la gigue de propagation entre voies reste dans les limites sp\u00e9cifi\u00e9es pour un alignement correct du SERDES \/ bo\u00eete de vitesses (gearbox).<\/p><\/li><li><p><strong>Budget de gigue :<\/strong> Respecter les masques de gigue \u00e9metteur\/r\u00e9cepteur IEEE (annexe 83A).<\/p><\/li><li><p><strong>Budget de perte de canal :<\/strong> Perte typique d\u2019environ 10 dB \u00e0 la fr\u00e9quence de Nyquist pour des pistes FR4 d\u2019environ 250 mm.<\/p><\/li><li><p><strong>\u00c9talonnage du SERDES :<\/strong> Mettre en \u0153uvre la pr\u00e9accentuation, le CTLE et le DFE selon les besoins.<\/p><\/li><li><p><strong>Compatibilit\u00e9 du module :<\/strong> V\u00e9rifier l\u2019ad\u00e9quation entre l\u2019interface h\u00f4te et le facteur de forme QSFP+.<\/p><\/li><li><p><strong>P\u00e9rennit\u00e9 :<\/strong> Planifiez des syst\u00e8mes 100 G (CAUI-10) ou 400 G avec une flexibilit\u00e9 de r\u00e9partition par voie (lane breakout).<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 R\u00e9sum\u00e9<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>XLAUI <\/strong>(Interface unitaire d\u2019attachement \u00e0 10 voies) est une <strong>norme d\u2019interface \u00e9lectrique critique<\/strong> pour les syst\u00e8mes 40 GbE. En divisant le d\u00e9bit 40 G en dix voies d\u2019environ 10,3 Gb\/s, elle permet des d\u00e9ploiements modulaires, haute densit\u00e9 et interop\u00e9rables de transceivers QSFP+. Les ing\u00e9nieurs int\u00e9grant <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26153-40g-qsfp.htm\"><strong>des transceivers 40 G QSFP+ LINK-PP<\/strong><\/a> doivent ma\u00eetriser la norme XLAUI afin d\u2019assurer une conception ad\u00e9quate des cartes de circuits imprim\u00e9s (PCB), une configuration correcte des SERDES et des performances fiables dans les centres de donn\u00e9es.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 FAQ<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Quelle est la fonction principale de XLAUI ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">XLAUI fournit une interface \u00e9lectrique normalis\u00e9e \u00e0 10 voies entre une ASIC h\u00f4te (ou un PHY) et un module QSFP+ 40 G. Elle permet un transfert de donn\u00e9es fiable \u00e0 40 Gb\/s tout en maintenant des vitesses par voie g\u00e9rables (environ 10,3125 Gb\/s) pour assurer l\u2019int\u00e9grit\u00e9 du signal et faciliter le routage sur les cartes PCB.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >En quoi XLAUI se distingue-t-elle de XAUI ou de CAUI ?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>XAUI :<\/strong> 4 voies pour le 10 GbE (environ 3,125 Gb\/s par voie apr\u00e8s codage).<\/p><\/li><li><p><strong>XLAUI :<\/strong> 10 voies pour le 40 GbE (environ 10,3125 Gb\/s par voie).<\/p><\/li><li><p><strong>CAUI :<\/strong> 10 ou 20 voies pour le 100 GbE (environ 10 \u00e0 25 Gb\/s par voie).<br\/>XLAUI \u00e9quilibre un d\u00e9bit agr\u00e9g\u00e9 plus \u00e9lev\u00e9 avec des vitesses mod\u00e9r\u00e9es par voie afin de simplifier la conception du syst\u00e8me.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >XLAUI peut-il \u00eatre utilis\u00e9 pour les connexions par plan arri\u00e8re ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Oui. Bien qu\u2019il soit principalement con\u00e7u pour les liaisons puce-module (ASIC \u2192 QSFP+), XLAUI peut prendre en charge les interconnexions par plan arri\u00e8re ou sur carte de circuits imprim\u00e9s (PCB), \u00e0 condition que les exigences en mati\u00e8re de perte de canal, de skew et d\u2019int\u00e9grit\u00e9 du signal soient respect\u00e9es.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Quel est le r\u00f4le des SERDES et de la bo\u00eete de vitesses (gearbox) dans XLAUI ?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/serdes-interfaces-high-speed-data-transfer-and-signal-integrity\/\"><strong>SERDES<\/strong><\/a><strong>:<\/strong> Convertit les donn\u00e9es parall\u00e8les en flux s\u00e9ries (et vice versa) sur chacune des 10 voies \u00e9lectriques.<\/p><\/li><li><p><strong>Bo\u00eete de vitesses (optionnelle) :<\/strong> Associe plusieurs voies \u00e9lectriques \u00e0 un nombre r\u00e9duit de voies optiques \u00e0 l\u2019int\u00e9rieur du module (par exemple, 10 voies \u00e9lectriques \u2192 4 voies optiques), tout en pr\u00e9servant l\u2019alignement.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Tous les modules QSFP+ 40G sont-ils conformes \u00e0 XLAUI ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Non. Certains modules utilisent des interfaces \u00e9lectriques alternatives \u00e0 4 voies, telles que XLPPI ou XLAUI-4. V\u00e9rifiez toujours la fiche technique du module concernant le nombre de voies, le type d\u2019interface \u00e9lectrique et la compatibilit\u00e9 avec l\u2019h\u00f4te.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Comment garantir un alignement correct des voies et une int\u00e9grit\u00e9 du signal ?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Ma\u00eetrisez le skew entre voies dans les limites sp\u00e9cifi\u00e9es par l\u2019IEEE.<\/p><\/li><li><p>Respectez les budgets de perte de canal et de gigue.<\/p><\/li><li><p>Utilisez les fonctionnalit\u00e9s des SERDES telles que la pr\u00e9accentuation, le CTLE et le DFE, conform\u00e9ment aux recommandations.<\/p><\/li><li><p>Validez le routage PCB, les performances des connecteurs et des r\u00e9p\u00e9teurs (retimers).<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Pourquoi XLAUI reste-t-il pertinent dans les r\u00e9seaux modernes ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Malgr\u00e9 l\u2019apparition de technologies plus r\u00e9centes de voies \u00e0 25 G ou 50 G, XLAUI demeure largement utilis\u00e9 pour les d\u00e9ploiements h\u00e9rit\u00e9s \u00e0 40 G, les conceptions haute densit\u00e9 de modules QSFP+, ainsi que les tissus de centre de donn\u00e9es \u00e0 d\u00e9bits mixtes. Il assure l\u2019interop\u00e9rabilit\u00e9 et fournit une r\u00e9f\u00e9rence \u00e9prouv\u00e9e de performance \u00e9lectrique.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Comment LINK-PP impl\u00e9mente-t-il XLAUI dans ses modules QSFP+ 40G ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26153-40g-qsfp.htm\">Les modules QSFP+ 40G de LINK-PP<\/a> (par exemple, LQ-CW40-LR4C) suivent les normes IEEE 802.3ba et impl\u00e9mentent des voies \u00e9lectriques \u00e9quivalentes \u00e0 XLAUI pour les connexions c\u00f4t\u00e9 h\u00f4te. Cela garantit des performances pr\u00e9visibles et une int\u00e9gration simplifi\u00e9e dans les commutateurs ou cartes lignes prenant en charge XLAUI \u00e0 10 voies.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Quelles consid\u00e9rations de conception les ing\u00e9nieurs doivent-ils garder \u00e0 l\u2019esprit lors du d\u00e9ploiement de XLAUI ?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>V\u00e9rifiez que l\u2019ASIC h\u00f4te prend en charge XLAUI \u00e0 10 voies.<\/p><\/li><li><p>Assurez-vous que la perte d\u2019insertion, la perte de retour et les couplages parasites (crosstalk) du canal respectent les normes.<\/p><\/li><li><p>Alignez correctement les voies des SERDES afin d\u2019\u00e9viter les erreurs.<\/p><\/li><li><p>Prenez en compte les contraintes thermiques et de puissance dans les d\u00e9ploiements denses.<\/p><\/li><li><p>Planifiez les chemins de r\u00e9partition des voies (lane breakout) pour les mises \u00e0 niveau futures (par exemple, vers 100 G ou 400 G).<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Les interfaces XLAUI peuvent-elles \u00eatre mises \u00e0 niveau vers des d\u00e9bits plus \u00e9lev\u00e9s \u00e0 l\u2019avenir ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Oui, mais cela n\u00e9cessite une planification rigoureuse. Des mises \u00e0 niveau futures vers CAUI ou d\u2019autres architectures \u00e0 plus grand nombre de voies peuvent affecter le routage PCB, les exigences en mati\u00e8re de r\u00e9p\u00e9teurs (retimers) et l\u2019allocation des SERDES. Une conception anticip\u00e9e ad\u00e9quate garantit la compatibilit\u00e9 ascendante avec <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26153-40g-qsfp.htm\">les modules QSFP+ 40G.<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>XLAUI (interface d\u2019unit\u00e9 de raccordement \u00e0 10 voies) permet des connexions haute vitesse et fiables entre les circuits int\u00e9gr\u00e9s h\u00f4tes et les modules QSFP+ dans les syst\u00e8mes Ethernet 40\/100 G.<\/p>","protected":false},"author":1,"featured_media":3792,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[27],"tags":[18,26],"class_list":["post-3793","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-glossary","tag-40g-qsfp-transceivers","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/3793","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/comments?post=3793"}],"version-history":[{"count":5,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/3793\/revisions"}],"predecessor-version":[{"id":10873,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/3793\/revisions\/10873"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media\/3792"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media?parent=3793"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/categories?post=3793"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/tags?post=3793"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}