{"id":3760,"date":"2025-11-19T00:00:00","date_gmt":"2025-11-19T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/troubleshooting-optical-link-performance-issues-guide\/"},"modified":"2026-06-22T04:54:04","modified_gmt":"2026-06-22T04:54:04","slug":"troubleshooting-optical-link-performance-issues-guide","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/troubleshooting-optical-link-performance-issues-guide","title":{"rendered":"Guide pratique pour le d\u00e9pannage des probl\u00e8mes courants de performance des liaisons optiques"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1408\" height=\"768\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ac8d1cefdcce45cdb166674fff535657.jpg\" alt=\"Troubleshooting Optical Link Performance Issues\" class=\"wp-image-3757\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ac8d1cefdcce45cdb166674fff535657.jpg 1408w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ac8d1cefdcce45cdb166674fff535657-300x164.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ac8d1cefdcce45cdb166674fff535657-1024x559.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ac8d1cefdcce45cdb166674fff535657-768x419.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ac8d1cefdcce45cdb166674fff535657-18x10.jpg 18w\" sizes=\"(max-width: 1408px) 100vw, 1408px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Une connexion r\u00e9seau qui clignote. Des pertes de paquets inexpliqu\u00e9es. Des ralentissements intermittents aux heures de pointe. Si vous g\u00e9rez un r\u00e9seau en fibre optique, ces probl\u00e8mes peuvent vous donner l\u2019impression de courser des fant\u00f4mes. Contrairement <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/what-is-twisted-pair-copper-cable-and-how-does-it-work\/\"><strong>aux c\u00e2bles en cuivre<\/strong><\/a>, les probl\u00e8mes d\u2019un lien optique ne sont pas toujours visibles \u00e0 l\u2019\u0153il nu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pas de panique ! Ce guide vous fournira une approche syst\u00e9matique pour diagnostiquer et r\u00e9soudre <strong>les probl\u00e8mes de performance les plus courants li\u00e9s aux liens optiques<\/strong>. En comprenant leurs causes profondes, vous pouvez r\u00e9duire au minimum les temps d\u2019arr\u00eat et garantir que votre r\u00e9seau fonctionne \u00e0 son efficacit\u00e9 maximale.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Comprendre les m\u00e9triques cl\u00e9s : les \u201c signes vitaux \u201d de votre lien<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Avant de vous lancer dans le d\u00e9pannage, vous devez savoir quoi mesurer. Chaque lien optique poss\u00e8de des indicateurs de performance cl\u00e9s (KPI) qui en constituent les signes vitaux. Les deux plus critiques sont :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px 0px 8px;\"><strong>Niveau de puissance optique :<\/strong> Mesur\u00e9 en d\u00e9cibels (dBm), il indique la puissance du signal lumineux.<\/p><ul><li><p style=\"margin: 0px;\"><strong>Puissance re\u00e7ue (Rx) :<\/strong> Trop \u00e9lev\u00e9e (saturation) ou trop faible (signal faible) peut provoquer des erreurs.<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px;\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/understanding-what-is-bit-error-rate\/\"><strong>taux d'erreur binaire (BER)<\/strong><\/a><strong>:<\/strong> Il s\u2019agit du rapport entre le nombre de bits erron\u00e9s et le nombre total de bits transmis. Un taux d\u2019erreur binaire (BER) \u00e9lev\u00e9 se traduit directement par une mauvaise performance et des pertes de paquets.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Un lien sain fonctionne dans une <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/power-budget-importance-calculation-management-for-devices\/\"><strong>budget de puissance optique utilisable<\/strong><\/a>, marge de puissance optique.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Sympt\u00f4mes courants et leurs causes profondes<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Voici une analyse des probl\u00e8mes les plus fr\u00e9quents, de leurs sympt\u00f4mes et de leurs causes probables.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Sympt\u00f4me<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Possible Cause<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>V\u00e9rification rapide<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Connectivit\u00e9 intermittente \/ basculements de lien<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Connecteurs sales ou endommag\u00e9s, connexions l\u00e2ches, \u00e9metteur-r\u00e9cepteur d\u00e9fectueux.<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Inspectez et nettoyez les connecteurs. R\u00e9ins\u00e9rez l\u2019\u00e9metteur-r\u00e9cepteur.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Taux d\u2019erreur binaire (BER) \u00e9lev\u00e9<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Puissance optique re\u00e7ue faible, perte de liaison \u00e9lev\u00e9e, dispersion ou \u00e9metteur-r\u00e9cepteur en fin de vie.<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>V\u00e9rifiez les niveaux de puissance Rx par rapport \u00e0 la fiche technique de l\u2019\u00e9metteur-r\u00e9cepteur.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>D\u00e9faillance compl\u00e8te du lien<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Cassure de la fibre, perte importante due \u00e0 une courbure, incompatibilit\u00e9 entre \u00e9metteurs-r\u00e9cepteurs ou d\u00e9faillance totale de l\u2019\u00e9metteur-r\u00e9cepteur.<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>V\u00e9rifiez la puissance Rx. Si elle est nulle ou extr\u00eamement faible, soup\u00e7onnez une rupture physique.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Erreurs uniquement aux d\u00e9bits \u00e9lev\u00e9s<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Limite de dispersion chromatique ou modale d\u00e9pass\u00e9e, \u00e9metteur-r\u00e9cepteur de mauvaise qualit\u00e9.<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Assurez-vous que votre \u00e9metteur-r\u00e9cepteur et le type de fibre sont homologu\u00e9s pour la distance et le d\u00e9bit requis.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Votre proc\u00e9dure de d\u00e9pannage \u00e9tape par \u00e9tape<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Suivez cette s\u00e9quence logique pour isoler et r\u00e9soudre efficacement le probl\u00e8me.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u00c9tape 1 : Les bases \u2013 Inspection physique<\/strong><br\/>Ne sous-estimez jamais cette \u00e9tape ! Plus de 70 % des probl\u00e8mes li\u00e9s aux liens optiques proviennent de d\u00e9fauts au niveau de la couche physique.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Nettoyage des connecteurs :<\/strong> Utilisez un microscope d\u2019inspection professionnel pour fibres optiques ainsi que des outils de nettoyage adapt\u00e9s. Les particules de poussi\u00e8re peuvent diffuser la lumi\u00e8re et entra\u00eener des pertes importantes.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>V\u00e9rification des courbures :<\/strong> Assurez-vous que tous les c\u00e2bles de raccordement en fibre sont exempts de courbures serr\u00e9es, de torsions ou de pincements. Le <strong>rayon de courbure minimal<\/strong> est critique.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>V\u00e9rification des connexions :<\/strong> Assurez-vous que tous les c\u00e2bles sont correctement ins\u00e9r\u00e9s dans les \u00e9metteurs-r\u00e9cepteurs et les panneaux de brassage.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u00c9tape 2 : Interroger le mat\u00e9riel \u2013 Lecture des diagnostics<\/strong><br\/>La plupart des \u00e9metteurs-r\u00e9cepteurs SFP, SFP+ et QSFP modernes int\u00e8grent des <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/ddm-dom-in-optical-transceivers\/\"><strong>Surveillance num\u00e9rique des diagnostics (DDM)<\/strong><\/a>, fonctions de surveillance num\u00e9rique (DDM)<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Puissance d\u2019\u00e9mission (Tx Power) :<\/strong> Est-elle comprise dans la plage attendue ?<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Puissance re\u00e7ue (Rx Power) :<\/strong> Est-elle comprise dans la plage de sensibilit\u00e9 du r\u00e9cepteur ? C\u2019est la m\u00e9trique la plus r\u00e9v\u00e9latrice.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Temp\u00e9rature et tension d\u2019alimentation :<\/strong> Des valeurs anormales peuvent indiquer un module en fin de vie.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u00c9tape 3 : Mesure pr\u00e9cise \u2013 Utilisation d\u2019un multim\u00e8tre optique et d\u2019une source lumineuse<\/strong><br\/>Si les donn\u00e9es DDM indiquent un probl\u00e8me, confirmez-le \u00e0 l\u2019aide d\u2019\u00e9quipements de test d\u00e9di\u00e9s.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\">Utilisez un <strong>Ensemble de test d\u2019att\u00e9nuation optique (OLTS)<\/strong> ou d\u2019un multim\u00e8tre optique combin\u00e9 \u00e0 une source laser pour mesurer la <strong>perte de liaison<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\">Comparez la perte mesur\u00e9e avec votre <strong>calcul du budget de liaison optique<\/strong>. Si la perte mesur\u00e9e est sup\u00e9rieure, un probl\u00e8me existe dans le parcours physique.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u00c9tape 4 : Isolation du segment \u2013 Test \u00e0 l\u2019OTDR<\/strong><br\/>Pour les liaisons longues ou lorsque vous soup\u00e7onnez une cassure de fibre ou une mauvaise \u00e9pissure, un <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/optical-time-domain-reflectometer-fiber-fault-detection-guide\/\"><strong>R\u00e9flectom\u00e8tre optique dans le domaine temporel (OTDR)<\/strong><\/a> r\u00e9flectom\u00e8tre optique dans le domaine temporel (OTDR).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Le c\u0153ur du lien : n\u2019oubliez pas vos \u00e9metteurs-r\u00e9cepteurs optiques<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5469abfde65b4d248f2de8e37d28da56.webp\" alt=\"optical transceiver\" class=\"wp-image-3758\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5469abfde65b4d248f2de8e37d28da56.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5469abfde65b4d248f2de8e37d28da56-300x169.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5469abfde65b4d248f2de8e37d28da56-1024x576.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5469abfde65b4d248f2de8e37d28da56-768x432.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5469abfde65b4d248f2de8e37d28da56-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>\u00e9metteur-r\u00e9cepteur optique<\/strong><\/a> L\u2019\u00e9metteur-r\u00e9cepteur optique.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">C\u2019est ici que le choix d\u2019un fournisseur fiable fait toute la diff\u00e9rence. Par exemple, l\u2019utilisation de modules haute performance et compatibles tels que le <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476046.htm\"><strong>LIEN-PP SFP28-25G-LR<\/strong><\/a> pour vos applications \u00e0 longue port\u00e9e 25G garantit une puissance de sortie stable et une sensibilit\u00e9 de r\u00e9ception sup\u00e9rieure. Cela contribue directement \u00e0 une <strong>budget de puissance optique utilisable<\/strong> marge de puissance optique <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.link-pp.com\/\"><strong>LIEN-PP<\/strong><\/a> Un \u00e9metteur-r\u00e9cepteur de qualit\u00e9 est con\u00e7u pour respecter strictement les <strong>limites de dispersion<\/strong>, ce qui est essentiel pour maintenir un faible taux d\u2019erreurs sur de longues distances.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Quand suspecter une d\u00e9faillance de l\u2019\u00e9metteur-r\u00e9cepteur :<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\">Les valeurs DDM sont syst\u00e9matiquement hors plage.<\/p><\/li><li><p style=\"margin: 0px;\">Le lien fonctionne avec un \u00e9metteur-r\u00e9cepteur mais pas avec un autre (apr\u00e8s avoir \u00e9cart\u00e9 les probl\u00e8mes de polarit\u00e9 et de longueur d\u2019onde).<\/p><\/li><li><p style=\"margin: 0px;\">Vous observez un nombre \u00e9lev\u00e9 d\u2019erreurs CRC sur le port commutateur.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Maintenance pr\u00e9ventive : \u00e9viter les probl\u00e8mes avant qu\u2019ils ne surviennent<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le meilleur d\u00e9pannage est celui que vous n\u2019avez jamais \u00e0 effectuer.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Documentez vos liaisons :<\/strong> Conservez les enregistrements des pertes calcul\u00e9es et mesur\u00e9es pour chaque liaison.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>\u00c9tablissez un r\u00e9gime de nettoyage&nbsp;:<\/strong> Exigez une \u201c&nbsp;inspection et un nettoyage&nbsp;\u201d avant chaque raccordement.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Surveillez les tendances DDM&nbsp;:<\/strong> Utilisez un logiciel de gestion r\u00e9seau pour surveiller l\u2019\u00e9tat des \u00e9metteurs-r\u00e9cepteurs dans le temps et recevoir des alertes avant qu\u2019une d\u00e9rive mineure ne devienne une panne majeure.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Achetez aupr\u00e8s de fournisseurs r\u00e9put\u00e9s&nbsp;:<\/strong> Assurez-vous que vos <strong>transceivers optiques compatibles<\/strong> proviennent de fournisseurs qui garantissent la conformit\u00e9 compl\u00e8te aux normes MSA et qui offrent un soutien technique solide. Investir d\u00e8s le d\u00e9part dans des composants de qualit\u00e9, tels que ceux de <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/page\/aboutus.htm\"><strong>LIEN-PP<\/strong><\/a>, constitue un pilier fondamental de la <strong>optimisation des performances du r\u00e9seau en fibre optique<\/strong> et de l\u2019\u00e9vitement des temps d\u2019arr\u00eat co\u00fbteux.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">En suivant cette approche structur\u00e9e, vous pouvez passer d\u2019une gestion r\u00e9active des incidents \u00e0 une gestion proactive du r\u00e9seau, garantissant ainsi que votre infrastructure optique n\u2019est pas seulement fonctionnelle, mais v\u00e9ritablement robuste et hautement performante.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 FAQ<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Que devez-vous faire en premier lieu lorsque votre liaison optique cesse de fonctionner&nbsp;?<\/h3>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Commencez par v\u00e9rifier les connexions physiques. Assurez-vous que tous les c\u00e2bles et connecteurs sont bien serr\u00e9s. Recherchez la pr\u00e9sence de salet\u00e9 ou de dommages sur ceux-ci. Nettoyer et remettre en place les connecteurs peut r\u00e9soudre rapidement le probl\u00e8me.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00c0 quelle fr\u00e9quence devez-vous nettoyer les connecteurs de fibre optique&nbsp;?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Nettoyez les connecteurs \u00e0 chaque d\u00e9connexion ou reconnexion. Pour de meilleurs r\u00e9sultats, inspectez et nettoyez tous les connecteurs une fois par mois. Un nettoyage r\u00e9gulier pr\u00e9vient les pertes de signal et maintient la solidit\u00e9 de votre r\u00e9seau.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Pouvez-vous utiliser n\u2019importe quel c\u00e2ble en fibre optique avec n\u2019importe quel appareil&nbsp;?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Non, ce n\u2019est pas possible. Le type de c\u00e2ble et le connecteur doivent \u00eatre compatibles avec votre appareil et votre \u00e9metteur-r\u00e9cepteur. V\u00e9rifiez toujours leur compatibilit\u00e9 avant de les raccorder. L\u2019utilisation d\u2019un c\u00e2ble inadapt\u00e9 peut provoquer des erreurs, voire des dommages.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Quels outils permettent de d\u00e9tecter les d\u00e9fauts des c\u00e2bles en fibre optique&nbsp;?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>R\u00e9flectom\u00e8tre optique dans le domaine temporel (OTDR)<\/p><\/li><li><p>Localisateur visuel de d\u00e9fauts (VFL)<\/p><\/li><li><p>Microscope d\u2019inspection de fibre<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ces outils vous aident \u00e0 identifier les ruptures, les courbures ou la salet\u00e9 pr\u00e9sentes sur le c\u00e2ble. Ils simplifient et acc\u00e9l\u00e8rent la d\u00e9tection et la r\u00e9solution des probl\u00e8mes.<\/p>","protected":false},"excerpt":{"rendered":"<p>Vous d\u00e9pannez une liaison optique ? Identifiez et r\u00e9solvez rapidement les probl\u00e8mes courants li\u00e9s aux fibres optiques \u00e0 l\u2019aide de solutions \u00e9tape par \u00e9tape pour garantir des performances r\u00e9seau fiables.<\/p>","protected":false},"author":1,"featured_media":3759,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13,14,15,18,24,26],"class_list":["post-3760","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules","tag-10g-sfp-transceivers","tag-link-pp-1g-sfp-modules","tag-40g-qsfp-transceivers","tag-link-pp","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/3760","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/comments?post=3760"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/3760\/revisions"}],"predecessor-version":[{"id":10861,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/3760\/revisions\/10861"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media\/3759"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media?parent=3760"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/categories?post=3760"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/tags?post=3760"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}