{"id":3578,"date":"2025-11-28T00:00:00","date_gmt":"2025-11-28T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/glossary\/what-is-physical-medium-dependent-pmd\/"},"modified":"2026-06-22T04:35:06","modified_gmt":"2026-06-22T04:35:06","slug":"what-is-physical-medium-dependent-pmd","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/what-is-physical-medium-dependent-pmd","title":{"rendered":"Guide pratique PMD (D\u00e9pendance du m\u00e9dium physique) pour les liens optiques"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe.webp\" alt=\"PMD (Physical Medium Dependent)\" class=\"wp-image-3574\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>des Moyens Mat\u00e9riels D\u00e9pendants (PMD)<\/strong> La sous-couche PMD est l\u2019un des \u00e9l\u00e9ments les plus importants de la couche physique Ethernet, pourtant elle est souvent mal comprise. La sous-couche PMD d\u00e9finit la mani\u00e8re dont les bits sont physiquement transmis et re\u00e7us sur un support sp\u00e9cifique \u2014 fibre monomode, fibre multimode, cuivre directement raccord\u00e9 ou plan arri\u00e8re \u00e9lectrique.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour les concepteurs de r\u00e9seaux, les ing\u00e9nieurs de test et les \u00e9quipes d\u2019approvisionnement, comprendre la sous-couche PMD est essentiel, car ses sp\u00e9cifications influencent directement <strong>l\u2019interop\u00e9rabilit\u00e9<\/strong>, <strong>reach<\/strong>, <strong>signal<\/strong>, and <strong>la s\u00e9lection des transceivers<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ce guide fournit une explication professionnelle et conforme aux normes de la sous-couche PMD, y compris les param\u00e8tres que vous devez \u00e9valuer lors de la s\u00e9lection de <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">\u00e9metteurs-r\u00e9cepteurs optiques<\/a> modules tels que SFP, SFP+ et QSFP.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Qu\u2019est-ce que la sous-couche d\u00e9pendante du support physique (PMD) ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>des Moyens Mat\u00e9riels D\u00e9pendants (PMD)<\/strong> La sous-couche PMD est le bloc fonctionnel le plus bas de la <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/ieee-802-3-ethernet-standard-explained\/\">IEEE 802.3<\/a> couche PHY. Elle d\u00e9finit les <strong>caract\u00e9ristiques optiques ou \u00e9lectriques<\/strong> requises pour une transmission r\u00e9ussie sur le support choisi.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dans les produits r\u00e9els, la sous-couche PMD correspond \u00e0 l\u2019interface avant d\u2019un transceiver optique \u2014 son laser, sa photodiode r\u00e9ceptrice, ses circuits de modulation et ses composants associ\u00e9s.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Ce que contr\u00f4le la sous-couche PMD<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>La longueur d\u2019onde optique et la largeur spectrale<\/p><\/li><li><p>La puissance moyenne d\u2019\u00e9mission (Tx) et les conditions d\u2019\u00e9mission<\/p><\/li><li><p>La sensibilit\u00e9 du r\u00e9cepteur (Rx) et ses limites de saturation<\/p><\/li><li><p>Optique <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/optical-transceiver-return-loss-back-reflection-guide\/\">perte de retour<\/a> et rapport d\u2019extinction<\/p><\/li><li><p>Le type de fibre pris en charge et la distance de liaison<\/p><\/li><li><p>Les masques d\u2019\u0153il d\u2019\u00e9mission\/r\u00e9ception \u00e9lectriques (pour les PHY \u00e9lectriques)<\/p><\/li><li><p>Les d\u00e9finitions des points de mesure pour les tests de conformit\u00e9<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">La sous-couche PMD agit comme le <strong>pont entre la logique PHY normalis\u00e9e et le monde physique<\/strong>, garantissant ainsi l\u2019interop\u00e9rabilit\u00e9 des transceivers de diff\u00e9rents fournisseurs sur la m\u00eame infrastructure en fibre.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f PMD par rapport aux autres sous-couches PHY<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019architecture PHY Ethernet comprend g\u00e9n\u00e9ralement :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/pcs-physical-coding-sublayer-ethernet-explained\/\"><strong>PCS (Sous-couche de codage physique)<\/strong> <\/a>\u2014 codage, 64b\/66b, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/fec-forward-error-correction-in-optical-communication\/\">FEC<\/a>, \u2014 r\u00e9partition des voies<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/pma-physical-medium-attachment-ethernet-explained\/\"><strong>PMA (Attachement au support physique)<\/strong><\/a> \u2014 s\u00e9rialisation\/d\u00e9s\u00e9rialisation, r\u00e9cup\u00e9ration d\u2019horloge<\/p><\/li><li><p><strong>PMD (D\u00e9pendant du support physique)<\/strong> \u2014 param\u00e8tres optiques ou \u00e9lectriques sp\u00e9cifiques au support<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">La sous-couche PMD est la partie directement li\u00e9e au budget optique et au type de support.<br\/>Une seule couche MAC peut prendre en charge plusieurs sous-couches PMD (par exemple SR, LR, ER), chacune \u00e9tant optimis\u00e9e pour une port\u00e9e ou un support diff\u00e9rent.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Pourquoi la sous-couche PMD est-elle cruciale dans les r\u00e9seaux r\u00e9els ?<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34.webp\" alt=\"Why PMD Matters in Real Networks\" class=\"wp-image-3575\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Interop\u00e9rabilit\u00e9 garantie<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Seuls les modules conformes aux m\u00eames sp\u00e9cifications PMD s\u2019interconnecteront de fa\u00e7on fiable. La longueur d\u2019onde, les niveaux de puissance et la sensibilit\u00e9 doivent \u00eatre conformes aux exigences IEEE.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Port\u00e9e du lien pr\u00e9visible<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les param\u00e8tres PMD d\u00e9finissent le budget de perte de liaison. Si un module sp\u00e9cifie une puissance d\u2019\u00e9mission (Tx) comprise entre \u20133 dBm et +3 dBm et une sensibilit\u00e9 de r\u00e9ception (Rx) de \u201314 dBm, le budget optique utilisable est calcul\u00e9 \u00e0 partir de ces valeurs.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Tests pr\u00e9cis et conformit\u00e9<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La PMD d\u00e9finit des points de test normalis\u00e9s (par exemple TP2, TP3), garantissant que la puissance optique, le jitter et les diagrammes d\u2019\u0153il sont mesur\u00e9s de fa\u00e7on coh\u00e9rente.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Fiabilit\u00e9 dans le temps<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les modules dot\u00e9s de marges PMD plus importantes tol\u00e8rent mieux le vieillissement, les variations de temp\u00e9rature, la contamination des fibres et les r\u00e9flexions au niveau des connecteurs que les modules con\u00e7us selon les exigences minimales.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Param\u00e8tres PMD cl\u00e9s \u00e0 \u00e9valuer<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Chaque sp\u00e9cification PMD comprend plusieurs m\u00e9triques optiques et \u00e9lectriques critiques. Leur compr\u00e9hension permet une s\u00e9lection appropri\u00e9e des modules.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Longueur d\u2019onde (\u03bb) et largeur spectrale<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Valeurs courantes incluant :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/850nm-optical-transceivers-for-short-reach-mmf-transmission\/\"><strong>850nm<\/strong><\/a> \u2014 courte port\u00e9e en multimode (SR)<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/1310nm-optical-module-applications-performance-comparison\/\"><strong>1310 nm<\/strong><\/a> \u2014 port\u00e9e moyenne en monomode (LR)<\/p><\/li><li><p>Plages sp\u00e9cifiques pour les variantes LX, BX, CWDM et DWDM<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">La largeur spectrale influence les performances en mati\u00e8re de dispersion, notamment pour les liaisons \u00e0 longue port\u00e9e.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Puissance moyenne d\u2019\u00e9mission (Tx)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Sp\u00e9cifie la puissance de sortie minimale et maximale.<br\/>Trop faible \u2192 la liaison risque de ne pas atteindre le r\u00e9cepteur.<br\/>Trop \u00e9lev\u00e9e \u2192 risque de saturation des r\u00e9cepteurs ou d\u2019effets non lin\u00e9aires.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Sensibilit\u00e9 et seuil de saturation du r\u00e9cepteur<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Sensibilit\u00e9 :<\/strong> niveau de puissance le plus faible auquel le r\u00e9cepteur satisfait aux exigences de taux d\u2019erreur binaire (BER)<\/p><\/li><li><p><strong>Seuil de saturation :<\/strong> puissance d\u2019entr\u00e9e maximale avant l\u2019apparition de distorsion du signal<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ces deux valeurs d\u00e9finissent le <strong>budget de puissance optique utilisable<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Rapport d\u2019extinction et perte de retour optique<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/extinction-ratio-importance-signal-quality-data-reliability\/\"><strong>Rapport d\u2019extinction<\/strong><\/a> garantit une distinction claire entre les \u00e9tats logiques \u201c 1 \u201d et \u201c 0 \u201d.\u201d<\/p><\/li><li><p><strong>Perte de retour optique<\/strong> d\u00e9termine la tol\u00e9rance aux r\u00e9flexions \u2014 essentielle sur les tron\u00e7ons longs en monomode.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Type de fibre pris en charge et port\u00e9e<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les tableaux PMD sp\u00e9cifient :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>la port\u00e9e sur fibre multimode OM2\/OM3\/OM4<\/p><\/li><li><p>la port\u00e9e sur fibre monomode G.652\/G.655<\/p><\/li><li><p>la longueur maximale prise en charge dans les budgets de puissance IEEE<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f La PMD dans la s\u00e9lection des transceivers optiques<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Lors du choix de modules optiques pour <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/what-is-a-data-center\/\">centres de donn\u00e9es<\/a>, les r\u00e9seaux industriels ou l\u2019infrastructure de t\u00e9l\u00e9communications, la conformit\u00e9 PMD garantit\u00a0:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Une interop\u00e9rabilit\u00e9 IEEE r\u00e9elle<\/p><\/li><li><p>Une port\u00e9e correcte sur la fibre existante<\/p><\/li><li><p>Des marges de perte pr\u00e9visibles<\/p><\/li><li><p>Des performances robustes dans des environnements soumis \u00e0 des contraintes thermiques ou bruyants<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Par exemple, le choix entre <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475415.htm\"><strong>10GBASE-SR<\/strong><\/a>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475586.htm\"><strong>10GBASE-LR<\/strong><\/a>, and <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476054.htm\"><strong>10GBASE-ER<\/strong><\/a> revient essentiellement \u00e0 choisir diff\u00e9rentes PMD optimis\u00e9es pour 300\u00a0m, 10\u00a0km ou 40\u00a0km.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b.webp\" alt=\"10GBASE-SR, 10GBASE-LR, and 10GBASE-E\" class=\"wp-image-3576\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Exemple de tableau r\u00e9capitulatif des PMD <\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Remplacez les valeurs par les param\u00e8tres exacts issus de la <\/em><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/file\/datasheet\/ls-sm3110-10c.pdf\"><em>fiche technique du module SFP+ choisi<\/em><\/a><em>.<\/em><\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 220px;\"\/><col style=\"width: 214px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Attribut PMD<\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>Valeur typique<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Description<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Longueur d\u2019onde<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>1310 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Laser monomode, longue port\u00e9e<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Puissance d\u2019\u00e9mission (min\/max)<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>\u20133\u00a0dBm \/ +3\u00a0dBm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Plage de puissance d\u2019\u00e9mission<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Sensibilit\u00e9 du r\u00e9cepteur<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>\u201314\u00a0dBm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Puissance minimale pour la conformit\u00e9 au taux d\u2019erreur binaire (BER)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Saturation du r\u00e9cepteur<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>+1\u00a0dBm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Entr\u00e9e maximale autoris\u00e9e<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Reach<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>10\u00a0km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>D\u00e9pend des pertes de la fibre et des \u00e9pissures<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Ratio Extinction<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>\u2265\u00a03,5\u00a0dB<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Qualit\u00e9 de modulation du laser<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Essais et conformit\u00e9 PMD<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Un essai PMD bien d\u00e9fini garantit une interop\u00e9rabilit\u00e9 fiable.<br\/>Les mesures cl\u00e9s comprennent\u00a0:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>La puissance optique \u00e0 l\u2019\u00e9metteur et au r\u00e9cepteur<\/p><\/li><li><p>La conformit\u00e9 au masque d\u2019\u0153il<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/jitter-in-optics-causes-effects-measurement-reduction\/\">Jitter<\/a> et la marge de bruit<\/p><\/li><li><p>Des essais effectu\u00e9s aux points de temp\u00e9rature d\u00e9finis<\/p><\/li><li><p>La v\u00e9rification de la sensibilit\u00e9 du r\u00e9cepteur dans des conditions contraintes<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ces mesures sont conformes aux proc\u00e9dures de conformit\u00e9 IEEE.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f D\u00e9pannage des d\u00e9faillances li\u00e9es \u00e0 la PMD<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Puissance re\u00e7ue faible<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">V\u00e9rifiez la propret\u00e9 des connecteurs, les pertes de fibre inattendues ou un raccordement excessif.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Clignotements de liaison sur les tron\u00e7ons longs<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Examinez le vieillissement de la puissance d\u2019\u00e9mission (Tx) ou une sensibilit\u00e9 limite \u2014 le budget optique peut \u00eatre trop serr\u00e9.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >La fibre multimode atteint une port\u00e9e plus courte que pr\u00e9vue<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">V\u00e9rifiez la compatibilit\u00e9 OM3\/OM4 ; les limitations de bande passante d\u00e9pendent du support.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>des Moyens Mat\u00e9riels D\u00e9pendants (PMD)<\/strong> La sous-couche est l\u2019un des concepts fondamentaux sous-tendant l\u2019interop\u00e9rabilit\u00e9 au niveau de la couche physique Ethernet. En sp\u00e9cifiant la longueur d\u2019onde optique, les plages de puissance, la sensibilit\u00e9, la port\u00e9e et les points de test, la sous-couche d\u00e9pendante du support physique (PMD) garantit que les transceivers provenant de diff\u00e9rents fournisseurs fonctionnent de fa\u00e7on pr\u00e9visible sur la m\u00eame infrastructure en fibre optique.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour les organisations qui d\u00e9ploient ou mettent \u00e0 niveau leurs r\u00e9seaux, la compr\u00e9hension de la sous-couche d\u00e9pendante du support physique (PMD) est essentielle afin de s\u00e9lectionner les bons modules optiques et de concevoir une liaison fiable, conforme aux normes et adapt\u00e9e \u00e0 l\u2019avenir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>Les transceivers optiques LINK-PP<\/strong><\/a> incluent des sp\u00e9cifications PMD clairement d\u00e9finies, ce qui en fait des choix excellents pour des conceptions r\u00e9seau robustes et conformes aux normes.<\/p>","protected":false},"excerpt":{"rendered":"<p>Le Physical Medium Dependent (PMD) d\u00e9finit les r\u00e8gles optiques et \u00e9lectriques d\u2019un PHY \u2014 longueur d\u2019onde, puissance, port\u00e9e et points de test. Comprenez les sp\u00e9cifications PMD et comment elles guident le choix des transceivers.<\/p>","protected":false},"author":1,"featured_media":3577,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[27],"tags":[24,26],"class_list":["post-3578","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-glossary","tag-link-pp","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/3578","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/comments?post=3578"}],"version-history":[{"count":5,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/3578\/revisions"}],"predecessor-version":[{"id":10826,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/3578\/revisions\/10826"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media\/3577"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media?parent=3578"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/categories?post=3578"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/tags?post=3578"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}