{"id":3539,"date":"2025-12-01T00:00:00","date_gmt":"2025-12-01T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/glossary\/fmmu-ethercat-fieldbus-memory-management-unit-guide\/"},"modified":"2026-06-22T04:30:14","modified_gmt":"2026-06-22T04:30:14","slug":"fmmu-ethercat-fieldbus-memory-management-unit-guide","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/fmmu-ethercat-fieldbus-memory-management-unit-guide","title":{"rendered":"Explication de l\u2019FMMU : L'unit\u00e9 centrale de cartographie m\u00e9moire dans EtherCAT"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b3640423b8524db9adc3f9275a6cfda1.webp\" alt=\"What Is FMMU (Fieldbus Memory Management Unit) in EtherCAT? A Complete Technical Guide\" class=\"wp-image-3534\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b3640423b8524db9adc3f9275a6cfda1.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b3640423b8524db9adc3f9275a6cfda1-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b3640423b8524db9adc3f9275a6cfda1-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b3640423b8524db9adc3f9275a6cfda1-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b3640423b8524db9adc3f9275a6cfda1-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Dans l\u2019automatisation industrielle moderne, l\u2019\u00e9change de donn\u00e9es en temps r\u00e9el est essentiel pour obtenir un contr\u00f4le rapide, synchronis\u00e9 et hautement fiable. <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/ethercat-definitive-guide-realtime-industrial-ethernet\/\">EtherCAT<br><\/a>\u2014 l\u2019une des principales technologies Ethernet industrielles \u2014 atteint ses performances exceptionnelles gr\u00e2ce \u00e0 plusieurs innovations architecturales. Parmi celles-ci, le <strong>FMMU (unit\u00e9 de gestion m\u00e9moire pour bus de terrain)<\/strong> joue un r\u00f4le central.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cet article fournit une explication claire et techniquement pr\u00e9cise de ce qu\u2019est l\u2019FMMU, de son importance et de la mani\u00e8re dont il permet \u00e0 EtherCAT d\u2019assurer une communication en temps r\u00e9el au niveau microseconde. Nous pr\u00e9sentons \u00e9galement comment <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">les modules \u00e9metteurs-r\u00e9cepteurs optiques SFP de LINK-PP <\/a>prennent en charge sans interruption les r\u00e9seaux EtherCAT haute vitesse.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Qu\u2019est-ce que l\u2019FMMU dans EtherCAT ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>FMMU (unit\u00e9 de gestion m\u00e9moire pour bus de terrain)<\/strong> est un m\u00e9canisme mat\u00e9riel int\u00e9gr\u00e9 \u00e0 chaque dispositif esclave EtherCAT qui associe <strong>des adresses logiques de donn\u00e9es processus provenant du ma\u00eetre EtherCAT<\/strong> au <strong>aux adresses physiques de m\u00e9moire des n\u0153uds esclaves individuels<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En termes simples :<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>L\u2019FMMU permet au ma\u00eetre EtherCAT d\u2019acc\u00e9der \u00e0 des donn\u00e9es dispers\u00e9es sur plusieurs dispositifs esclaves comme s\u2019il s\u2019agissait d\u2019un seul bloc continu de m\u00e9moire.<\/strong><\/p><\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">Ce m\u00e9canisme est essentiel au traitement \u201c en vol \u201d haute vitesse d\u2019EtherCAT, permettant une communication d\u00e9terministe et \u00e0 faible latence sur le bus de terrain.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Pourquoi EtherCAT a-t-il besoin d\u2019un FMMU ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Les syst\u00e8mes de bus de terrain traditionnels exigent souvent que le ma\u00eetre communique s\u00e9par\u00e9ment avec chaque n\u0153ud, ce qui entra\u00eene :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Une latence plus \u00e9lev\u00e9e<\/p><\/li><li><p>Une surcharge de communication accrue<\/p><\/li><li><p>Des taux de rafra\u00eechissement r\u00e9duits<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">EtherCAT r\u00e9sout ce probl\u00e8me avec une approche diff\u00e9rente :<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2714 La trame EtherCAT traverse tous les esclaves s\u00e9quentiellement.<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Chaque esclave lit et \u00e9crit uniquement les donn\u00e9es qui lui sont destin\u00e9es.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2714 L\u2019FMMU garantit que les donn\u00e9es sont plac\u00e9es \u00e0 la position logique correcte.<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le r\u00e9sultat est un \u00e9change cyclique de donn\u00e9es extr\u00eamement efficace.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Avantages cl\u00e9s permis par l\u2019FMMU :<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Un espace d\u2019adresses logiques continu<\/strong> pour le ma\u00eetre<\/p><\/li><li><p><strong>Un mappage pr\u00e9cis au niveau de l\u2019octet<\/strong><\/p><\/li><li><p><strong>Un traitement \u00ab en vol \u00bb sans copie<\/strong><\/p><\/li><li><p><strong>Des temps de cycle ultra-faibles (inf\u00e9rieurs \u00e0 100 \u00b5s)<\/strong><\/p><\/li><li><p><strong>Une utilisation \u00e9lev\u00e9e de la bande passante (proche de 100 %)<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">C\u2019est l\u2019une des raisons principales pour lesquelles <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/ethercat-definitive-guide-realtime-industrial-ethernet\/\">EtherCAT<br><\/a> convient \u00e0 :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Commande de mouvement<br><\/p><\/li><li><p>la robotique<\/p><\/li><li><p>les variateurs de vitesse haute vitesse<\/p><\/li><li><p>l\u2019automatisation de pr\u00e9cision<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >Fonctionnement de l\u2019FMMU : mappage entre adresses logiques et adresses physiques<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La communication EtherCAT utilise deux types d\u2019adressage m\u00e9moire :<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Adresse logique (vue Ma\u00eetre)<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/808e8441e1fd4bc99473773fa9d4b233.jpg\" alt=\"FMMU Logical Address (Master view)\" class=\"wp-image-3535\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/808e8441e1fd4bc99473773fa9d4b233.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/808e8441e1fd4bc99473773fa9d4b233-300x300.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/808e8441e1fd4bc99473773fa9d4b233-150x150.jpg 150w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/808e8441e1fd4bc99473773fa9d4b233-768x768.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/808e8441e1fd4bc99473773fa9d4b233-12x12.jpg 12w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Un espace d\u2019adresses virtuel et continu d\u00e9fini par le Ma\u00eetre pour les donn\u00e9es de processus.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Adresse physique (vue Esclave)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Adresses r\u00e9elles des registres ou des tampons de donn\u00e9es \u00e0 l\u2019int\u00e9rieur d\u2019un dispositif esclave.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>Le FMMU mappe la m\u00e9moire logique \u2192 la m\u00e9moire physique<\/strong>, permettant :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Une granularit\u00e9 au niveau du bit<\/p><\/li><li><p>Un contr\u00f4le de lecture\/\u00e9criture<\/p><\/li><li><p>Une synchronisation efficace avec les gestionnaires de synchronisation (SyncManagers)<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Exemple :<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Si le Ma\u00eetre cr\u00e9e une zone PDO logique de 60 octets :<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Esclave<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>M\u00e9moire physique<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Adresse logique mapp\u00e9e<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Esclave A<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>0x1100<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>0x0000 \u2013 0x000F<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Esclave B<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>0x2000<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>0x0010 \u2013 0x0023<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Esclave C<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>0x3200<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>0x0024 \u2013 0x003B<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Le Ma\u00eetre lit\/\u00e9crit uniquement <strong>une zone continue de 60 octets<\/strong>, mais les donn\u00e9es sont automatiquement achemin\u00e9es vers chaque esclave via leur mat\u00e9riel FMMU.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"459\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5b84055a9e1044699d33658cfa74b356.webp\" alt=\"What Is the FMMU in EtherCAT?\" class=\"wp-image-3536\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5b84055a9e1044699d33658cfa74b356.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5b84055a9e1044699d33658cfa74b356-300x115.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5b84055a9e1044699d33658cfa74b356-1024x392.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5b84055a9e1044699d33658cfa74b356-768x294.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5b84055a9e1044699d33658cfa74b356-18x7.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >FMMU int\u00e9gr\u00e9 dans le contr\u00f4leur esclave EtherCAT (ESC)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le FMMU est impl\u00e9ment\u00e9 dans le <strong>ESC (contr\u00f4leur d\u2019esclave EtherCAT)<\/strong>, qui est int\u00e9gr\u00e9 dans les circuits esclaves EtherCAT tels que :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Beckhoff ET1100<\/p><\/li><li><p>ET1200<\/p><\/li><li><p>Noyaux IP ESC tiers<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Un ESC typique comprend :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Des FMMU (g\u00e9n\u00e9ralement 1 \u00e0 3 instances)<\/strong><\/p><\/li><li><p><strong>Des gestionnaires de synchronisation (SM)<\/strong><\/p><\/li><li><p><strong>Une machine \u00e0 \u00e9tats AL<\/strong><\/p><\/li><li><p><strong>Des gestionnaires de bo\u00eete aux lettres (mailbox handlers)<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">La configuration du FMMU est effectu\u00e9e lors de l\u2019initialisation via les protocoles de bo\u00eete aux lettres (CoE, FoE, EoE).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >FMMU et traitement en temps r\u00e9el (on-the-fly)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019une des caract\u00e9ristiques fondamentales d\u2019EtherCAT est que les esclaves <strong>ne copient ni ne mettent en m\u00e9moire tampon l\u2019int\u00e9gralit\u00e9 de la trame Ethernet<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c0 la place :<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>La trame Ethernet traverse l\u2019esclave.<\/p><\/li><li><p>Le FMMU v\u00e9rifie quels octets appartiennent \u00e0 cet esclave.<\/p><\/li><li><p>Les donn\u00e9es sont ins\u00e9r\u00e9es ou extraites en temps r\u00e9el.<\/p><\/li><li><p>La trame se poursuit vers l\u2019esclave suivant avec un d\u00e9lai de quelques nanosecondes.<\/p><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Cette conception permet des taux de mise \u00e0 jour de l\u2019ordre de :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>&lt; 100 \u03bcs pour la commande servo de plus de 100 axes<\/strong><\/p><\/li><li><p><strong>&lt; 10 \u03bcs de d\u00e9lai de transfert par esclave<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Aucune autre architecture de bus de terrain n\u2019atteint ce niveau de d\u00e9terminisme avec un c\u00e2blage aussi simple.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Applications o\u00f9 le FMMU est critique<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le FMMU contribue directement aux performances d\u2019EtherCAT dans :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Les contr\u00f4leurs de mouvement multi-axes<\/p><\/li><li><p>Les robots de pr\u00e9l\u00e8vement et de d\u00e9p\u00f4t (pick-and-place)<\/p><\/li><li><p>Les machines-outils \u00e0 commande num\u00e9rique (CNC)<\/p><\/li><li><p>Les \u00e9quipements d\u2019emballage et d\u2019impression<\/p><\/li><li><p>La fabrication de semi-conducteurs<\/p><\/li><li><p>Les entr\u00e9es\/sorties distribu\u00e9es en temps r\u00e9el<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">L\u00e0 o\u00f9 la boucle de commande est extr\u00eamement serr\u00e9e, le FMMU garantit une coh\u00e9rence stable et pr\u00e9cise des donn\u00e9es.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Produits industriels en fibre optique LINK-PP pour r\u00e9seaux EtherCAT<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/68b2a236f98f4fe3bc2f22d4e290d690.webp\" alt=\"industrial-grade fiber transceivers\" class=\"wp-image-3537\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/68b2a236f98f4fe3bc2f22d4e290d690.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/68b2a236f98f4fe3bc2f22d4e290d690-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/68b2a236f98f4fe3bc2f22d4e290d690-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/68b2a236f98f4fe3bc2f22d4e290d690-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/68b2a236f98f4fe3bc2f22d4e290d690-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">EtherCAT utilise couramment des couches physiques Ethernet telles que :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>100BASE-TX<\/p><\/li><li><p>100BASE-FX<\/p><\/li><li><p>1000BASE-X<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Pour les environnements n\u00e9cessitant des communications \u00e0 longue distance ou r\u00e9sistantes aux interf\u00e9rences \u00e9lectromagn\u00e9tiques (EMI), LINK-PP propose une vaste gamme de<a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476820.htm\"> <strong>transceivers industriels en fibre optique<\/strong><\/a><strong> and <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26155-1g-sfp.htm\"><strong>Modules SFP<\/strong><\/a>:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Avantages pour les applications EtherCAT :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Immunit\u00e9 \u00e9lev\u00e9e aux perturbations \u00e9lectromagn\u00e9tiques (CEM)<\/p><\/li><li><p>Options de temp\u00e9rature industrielle allant de \u221240 \u00b0C \u00e0 +85 \u00b0C<\/p><\/li><li><p>Faible latence et performances optiques stables<\/p><\/li><li><p>Compatibilit\u00e9 avec les automates programmables (API), les variateurs de vitesse servo et les commutateurs industriels<\/p><\/li><li><p>Liaisons \u00e0 longue distance allant jusqu\u2019\u00e0 80 km<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ces modules optiques garantissent une connectivit\u00e9 fiable au niveau de la couche physique pour les r\u00e9seaux EtherCAT reposant sur un contr\u00f4le d\u00e9terministe bas\u00e9 sur les FMMU.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >R\u00e9sum\u00e9<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>FMMU (unit\u00e9 de gestion m\u00e9moire pour bus de terrain)<\/strong> est l\u2019une des innovations fondamentales qui font d\u2019EtherCAT l\u2019un des r\u00e9seaux industriels les plus rapides et les plus d\u00e9terministes. En mappant les donn\u00e9es de processus logiques vers des adresses physiques sp\u00e9cifiques aux esclaves et en prenant en charge le traitement des trames \u00e0 la vol\u00e9e, la FMMU permet :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Des temps de cycle au niveau de la microseconde<\/p><\/li><li><p>Une synchronisation tr\u00e8s pr\u00e9cise<\/p><\/li><li><p>Une utilisation efficace de la bande passante<\/p><\/li><li><p>Un contr\u00f4le distribu\u00e9 \u00e9volutif<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Lorsqu\u2019elle est associ\u00e9e \u00e0 des modules optiques industriels robustes, tels que les <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">modules SFP et transceivers fibre de LINK-PP<\/a>, EtherCAT devient une infrastructure puissante et fiable pour les syst\u00e8mes d\u2019automatisation modernes.<\/p>","protected":false},"excerpt":{"rendered":"<p>Apprenez ce qu\u2019est l\u2019FMMU (Fieldbus Memory Management Unit) et comment il permet une communication EtherCAT en temps r\u00e9el gr\u00e2ce \u00e0 une cartographie m\u00e9moire efficace et un traitement des donn\u00e9es en temps r\u00e9el.<\/p>","protected":false},"author":1,"featured_media":3538,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[27],"tags":[26],"class_list":["post-3539","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-glossary","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/3539","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/comments?post=3539"}],"version-history":[{"count":5,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/3539\/revisions"}],"predecessor-version":[{"id":10817,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/3539\/revisions\/10817"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media\/3538"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media?parent=3539"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/categories?post=3539"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/tags?post=3539"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}