{"id":3516,"date":"2025-12-02T00:00:00","date_gmt":"2025-12-02T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/ieee-802-3cd-50g-100g-200g-pam4-ethernet\/"},"modified":"2026-06-22T08:57:41","modified_gmt":"2026-06-22T08:57:41","slug":"ieee-802-3cd-50g-100g-200g-pam4-ethernet","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/ieee-802-3cd-50g-100g-200g-pam4-ethernet","title":{"rendered":"Explication de IEEE 802.3cd : Ethernet 50G, 100G et 200G avec PAM4"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540.webp\" alt=\"What Is IEEE 802.3cd?\" class=\"wp-image-3513\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Qu'est-ce que IEEE 802.3cd ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">IEEE 802.3cd est la norme Ethernet qui d\u00e9finit les sp\u00e9cifications du Couche Physique (PHY) et <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/what-is-physical-medium-dependent-pmd\/\">des Moyens Mat\u00e9riels D\u00e9pendants (PMD)<\/a> pour <strong>les r\u00e9seaux 50 GbE, 100 GbE et 200 GbE<\/strong> utilisant <strong>des voies 50G PAM4<\/strong>. Finalis\u00e9e en 2018, cette norme a introduit le signalisation \u00e0 une seule voie de 50G et des combinaisons \u00e0 plusieurs voies (2\u00d750G et 4\u00d750G), permettant une Ethernet haute vitesse \u00e9volutif avec une meilleure efficacit\u00e9 des ports et un co\u00fbt par bit r\u00e9duit.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La norme joue un r\u00f4le central dans les centres de donn\u00e9es modernes, o\u00f9 les transceivers optiques PAM4 \u2014 particuli\u00e8rement <strong>SFP56, <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491591.htm\"><strong>QSFP28<\/strong><\/a><strong>, QSFP56 et QSFP-DD<\/strong>\u2014 sont largement d\u00e9ploy\u00e9s dans les chemins de migration de 25G \u00e0 200G.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Pourquoi IEEE 802.3cd utilise-t-il la modulation PAM4<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Une caract\u00e9ristique d\u00e9finissante de 802.3cd est la transition de NRZ (PAM2) \u00e0 <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\"><strong>PAM4<\/strong> modulation<\/a>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Avantages cl\u00e9s de PAM4<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Densit\u00e9 de donn\u00e9es plus \u00e9lev\u00e9e :<\/strong> PAM4 encode deux bits par symbole, doublant ainsi le d\u00e9bit dans la m\u00eame bande passante.<\/p><\/li><li><p><strong>Viabilit\u00e9 d'une seule voie 50G :<\/strong> atteint 50 Gb\/s par voie \u00e0 un taux symbolique d'environ 50 GBd.<\/p><\/li><li><p><strong>Meilleure \u00e9volutivit\u00e9 :<\/strong> permet l'expansion de la bande passante de 50G \u2192 100G \u2192 200G sans redessiner les formes des ports.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Avec PAM4, Ethernet pourrait \u00e9voluer en utilisant des formats de modules familiers tout en supportant des vitesses aggreg\u00e9es beaucoup plus \u00e9lev\u00e9es.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc PMDs et types d'interfaces d\u00e9finis sous IEEE 802.3cd<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >PMDs 50 GbE<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>50GBASE-SR<\/strong> \u2013 Fibre multimode \u00e0 courte port\u00e9e utilisant une seule voie 50G PAM4.<\/p><\/li><li><p><strong>50GBASE-FR<\/strong> \u2013 Fibre monomode, g\u00e9n\u00e9ralement jusqu'\u00e0 2 km.<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491591.htm\"><strong>50GBASE-LR<\/strong><\/a> \u2013 SMF avec une port\u00e9e de 10 km pour les applications campus et m\u00e9tropolitaines.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >PMDs 100 GbE (2\u00d750G)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>100GBASE-FR2<\/strong> \u2013 Deux voies PAM4 sur SMF, port\u00e9e mod\u00e9r\u00e9e.<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491583.htm\"><strong>100GBASE-LR2<\/strong><\/a> \u2013 Applications longue port\u00e9e SMF \u00e0 deux voies.<\/p><\/li><li><p><strong>100GBASE-DR\/DR2<\/strong> \u2013 Optimis\u00e9 pour les liens SMF courts \u00e0 moyens dans les centres de donn\u00e9es.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >PMDs 200 GbE (4\u00d750G)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473139.htm\"><strong>200GBASE-SR4<\/strong><\/a> \u2013 Quatre voies 50G sur MMF parall\u00e8le ; id\u00e9al pour la connectivit\u00e9 haute densit\u00e9 feuilles\/enclumes.<\/p><\/li><li><p><strong>200GBASE-FR4 \/ LR4<\/strong> \u2013 Solutions SMF \u00e0 quatre voies permettant des port\u00e9es de 2 km et 10 km respectivement.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">3cd d\u00e9finit les param\u00e8tres \u00e9lectriques et optiques pour ces interfaces, y compris TDECQ, OMAouter du transmetteur, sensibilit\u00e9 du r\u00e9cepteur et objectifs de BER par voie.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Cas d'utilisation de d\u00e9ploiement dans les centres de donn\u00e9es modernes<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >50G \u00e0 une seule voie pour les serveurs<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">De nombreux centres de donn\u00e9es hyperscale et d'entreprise adoptent <strong>interfaces SFP56 50G<\/strong> pour les liens d'acc\u00e8s serveur, rempla\u00e7ant le 25G comme bande passante standard du n\u0153ud.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >100G comme couche de mont\u00e9e<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">En utilisant 2\u00d750G voies, les liens 100G restent une couche d'agr\u00e9gation principale entre les commutateurs Top-of-Rack (ToR) et leaf. <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472577.htm\">100 G QSFP28<\/a> ou modules SFP-DD offrent une densit\u00e9 efficace et une compatibilit\u00e9 descendante.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >200G pour les tissus Leaf-to-Spine<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473139.htm\">transceivers QSFP56 200G<\/a> ou QSFP-DD permettent des architectures 50G \u00e0 quatre voies avec flexibilit\u00e9 de d\u00e9branchements. Un port 200G unique peut \u00eatre divis\u00e9 en <strong>4\u00d750G<\/strong> pour les serveurs ou les n\u0153uds d'agr\u00e9gation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Flexibilit\u00e9 de d\u00e9branchement<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">L'architecture bas\u00e9e sur les voies rend 802.3cd id\u00e9al pour :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>200G QSFP56 \u2192 4\u00d750G SFP56<\/p><\/li><li><p>100G QSFP28 \u2192 2\u00d750G SFP56<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ce qui s'aligne bien avec la transition prochaine des serveurs 25G vers 50G.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc S\u00e9lection des bons transceivers optiques pour IEEE 802.3cd<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480.webp\" alt=\"802.3cd-compliant optical transceivers\" class=\"wp-image-3514\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Lors de la planification d'un r\u00e9seau 50G\/100G\/200G, le choix du transceiver doit correspondre \u00e0 <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/what-is-physical-medium-dependent-pmd\/\">PMD<\/a> type, port\u00e9e sur fibre et forme du port de commutateur.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour les d\u00e9ploiements IEEE 802.3cd, LINK-PP propose les cat\u00e9gories de produits suivantes :<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Transceivers optiques 50G (SFP56 \/ QSFP28)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pour une seule voie 50GBASE-SR\/FR\/LR et l'acc\u00e8s serveur 50G :<br\/>\ud83d\udd17 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27046-50g-qsfp28-sfp56.htm\">https:\/\/www.l-p.com\/store-27046-50g-qsfp28-sfp56.htm<\/a><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Transceivers optiques 100G (QSFP28 \/ SFP-DD)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Id\u00e9al pour les mont\u00e9es 2\u00d750G, agr\u00e9gation 100G de l'\u00e9pine dorsale et applications DR\/FR\/LR :<br\/>\ud83d\udd17 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\">https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm<\/a><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Transceivers optiques 200G (QSFP-DD \/ QSFP56)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Con\u00e7us pour les tissus Leaf-spine 4\u00d750G et la compatibilit\u00e9 de d\u00e9branchement :<br\/>\ud83d\udd17 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26224-200g-qsfp-dd-qsfp56.htm\">https:\/\/www.l-p.com\/store-26224-200g-qsfp-dd-qsfp56.htm<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ces modules supportent la signalisation PAM4 et r\u00e9pondent aux cibles d'interop\u00e9rabilit\u00e9 IEEE telles que la performance TDECQ, la sensibilit\u00e9 du r\u00e9cepteur et la coh\u00e9rence BER par voie.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Liste de v\u00e9rification d'interop\u00e9rabilit\u00e9 et de validation<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Pour assurer un d\u00e9ploiement fiable 802.3cd, les ing\u00e9nieurs v\u00e9rifient g\u00e9n\u00e9ralement :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Type PMD correct<\/strong> (SR, FR, LR, DR) pour le budget de lien et la port\u00e9e.<\/p><\/li><li><p><strong>Correspondance de la forme<\/strong> (SFP56, QSFP28, QSFP56, QSFP-DD).<\/p><\/li><li><p><strong>Niveaux de puissance optique<\/strong> incluant OMAouter et puissance moyenne de lancement.<\/p><\/li><li><p><strong>Sensibilit\u00e9 du r\u00e9cepteur<\/strong> sous conditions PAM4 stress\u00e9es.<\/p><\/li><li><p><strong>Cibles de BER par voie<\/strong> and <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/fec-forward-error-correction-in-optical-communication\/\">FEC<\/a> compatibilit\u00e9.<\/p><\/li><li><p><strong>Cartographie de d\u00e9branchement<\/strong> lors du m\u00e9lange d'extr\u00e9mit\u00e9s 200G \u2194 50G.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">IEEE 802.3cd a \u00e9tabli les blocs techniques pour aujourd'hui <strong>Ethernet 50G, 100G et 200G<\/strong>, apportant <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\">modulation PAM4<\/a> \u00e0 la mise en \u0153uvre principale. Son architecture bas\u00e9e sur les voies permet des augmentations de bande passante \u00e9volutives et \u00e9conomiques tout en maintenant les formats de modules familiers.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Alors que les centres de donn\u00e9es continuent de migrer de 25G et 40G vers des tissus \u00e0 vitesse plus \u00e9lev\u00e9e, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473139.htm\">transceivers optiques conformes \u00e0 802.3cd<\/a>\u2014tels que les familles de produits 50G\/100G\/200G de LINK-PP\u2014fournissent une base fiable pour la connectivit\u00e9 de nouvelle g\u00e9n\u00e9ration.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour des sp\u00e9cifications d\u00e9taill\u00e9es et un choix de produits, explorez <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">LINK-PP<\/a> l'ensemble complet des transceivers compatibles avec IEEE 802.3cd.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Termes optiques et \u00e9lectriques cl\u00e9s dans IEEE 802.3cd (Mini glossaire)<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2605 TDECQ (Fermeture de l'\u0153il pour la dispersion et l'\u00e9metteur pour PAM4)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le TDECQ est un indicateur de qualit\u00e9 d'\u00e9metteur utilis\u00e9 dans les interfaces bas\u00e9es sur PAM4. Il quantifie dans quelle mesure le diagramme oculaire optique \u201cse ferme\u201d apr\u00e8s que le signal a subi une dispersion, du bruit et d'autres d\u00e9gradations du canal. Une <strong>valeur TDECQ inf\u00e9rieure<\/strong> indique un signal PAM4 plus propre avec une marge de lien am\u00e9lior\u00e9e. IEEE 802.3cd utilise TDECQ comme exigence principale pour les transmetteurs optiques 50G, 100G et 200G.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2605 OMAouter (Amplitude de modulation optique externe)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">OMAouter repr\u00e9sente la diff\u00e9rence entre les niveaux d'intensit\u00e9 optique les plus \u00e9lev\u00e9s et les plus bas (Niveau 3 et Niveau 0) dans un signal PAM4. \u00c9tant donn\u00e9 que le PAM4 utilise quatre niveaux discrets, OMAouter fournit une repr\u00e9sentation plus pr\u00e9cise de la profondeur de modulation que la puissance moyenne. Une valeur OMAouter plus \u00e9lev\u00e9e g\u00e9n\u00e9ralement am\u00e9liore la sensibilit\u00e9 du r\u00e9cepteur et aide \u00e0 garantir des performances conformes aux normes pour 50GBASE-SR\/FR\/LR et les variantes multi-lanes. <strong>une OMAouter plus \u00e9lev\u00e9e<\/strong> am\u00e9liore g\u00e9n\u00e9ralement la sensibilit\u00e9 du r\u00e9cepteur et aide \u00e0 garantir des performances conformes aux normes pour 50GBASE-SR\/FR\/LR et les variantes multi-lanes. <strong>\u2605 BER (Taux d'erreur binaire)<\/strong> mesure le rapport entre les bits erron\u00e9s et le nombre total de bits transmis. IEEE 802.3cd sp\u00e9cifie des objectifs de BER par lane, typiquement en utilisant une cible de BER avant correction d'erreur (pre-FEC) de 2,4\u00d710\u207b\u2074 pour les lanes PAM4. Avec une correction d'erreur avanc\u00e9e (comme KP4 FEC), le BER apr\u00e8s correction d'erreur atteint la fiabilit\u00e9 requise pour les r\u00e9seaux de centres de donn\u00e9es hyperscale et cloud.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\ud83d\udccc FAQ<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/understanding-what-is-bit-error-rate\/\">BER<\/a> Qu'est-ce que IEEE 802.3cd ? <strong>IEEE 802.3cd est une norme Ethernet qui d\u00e9finit les sp\u00e9cifications du niveau physique pour 50GbE, 100GbE et 200GbE en utilisant...<\/strong>, 50GbE, 100GbE et 200GbE <strong>Il inclut des interfaces telles que...<\/strong> 50GBASE-SR\/FR\/LR.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >100GBASE-SR2<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >, visant les environnements de r\u00e9seau modernes de centre de donn\u00e9es et haute performance.<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">26. Quel format de modulation utilise IEEE 802.3cd ? <strong>IEEE 802.3cd impose le PAM4 (Modulation d'amplitude d'impulsion \u00e0 4 niveaux) pour toutes les interfaces 50G par lane. Le PAM4 double le d\u00e9bit binaire par lane par rapport au NRZ tout en maintenant le m\u00eame taux de bauds, permettant ainsi des architectures Ethernet 50G, 100G et 200G \u00e9volutives.<\/strong> 29. IEEE 802.3cd prend-il en charge la compatibilit\u00e9 descendante avec NRZ ? <strong>modulation PAM4<\/strong>. Oui, dans de nombreuses implantations, les liens bas\u00e9s sur PAM4 peuvent coexister avec des interfaces NRZ... <strong>\u00e0 condition que le port h\u00f4te, l'interface \u00e9lectrique et le module optique soient con\u00e7us pour prendre en charge des environnements mixtes.<\/strong>, <strong>Cependant, PAM4 et NRZ ne peuvent pas interop\u00e9rer sur un seul lien ; les deux extr\u00e9mit\u00e9s doivent utiliser le m\u00eame format de modulation.<\/strong>, and <strong>200GBASE-SR4<\/strong>, 34. Quels sont les cas d'utilisation typiques d'IEEE 802.3cd ?.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >IEEE 802.3cd est largement utilis\u00e9 pour :<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">acc\u00e8s serveur 50G (SFP56, QSFP28) <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/what-is-physical-medium-dependent-pmd\/\"><strong>couches de jonction\/spine 100G<\/strong><\/a> structures leaf-spine 200G.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >centres de donn\u00e9es cloud, clusters AI\/ML et r\u00e9seaux hyperscale<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">uplinks 50G par lane dans les architectures modulaires (2\u00d750G, 4\u00d750G) <strong>42. Quels transceivers optiques sont conformes \u00e0 IEEE 802.3cd ?<\/strong>. IEEE 802.3cd prend en charge une large gamme de modules optiques 50G, 100G et 200G, y compris :.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >(SFP56 \/ QSFP28) pour 50GbE \u00e0 une seule lane<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">et modules breakout 2\u00d750G (QSFP28 \/ SFP-DD)<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>200GBASE-SR4\/DR4\/FR4<\/p><\/li><li><p>(QSFP-DD \/ QSFP56) propose des options conformes \u00e0 IEEE 802.3cd pour toutes les classes de vitesse.<\/p><\/li><li><p>49. Comment IEEE 802.3cd se rapporte-t-il \u00e0 IEEE 802.3bs (400G) et 802.3cu ?<\/p><\/li><li><p>802.3bs<\/p><\/li><li><p>d\u00e9finit 400GbE et repose \u00e9galement sur des lanes 50G, mais se concentre sur des architectures \u00e0 nombre \u00e9lev\u00e9 de lanes (par exemple, 8\u00d750G).<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >802.3cu<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u00e9tend 100G\/400G aux applications \u00e0 longue port\u00e9e sur fibre monomode (SMF) (DR\/FR\/LR).<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>\u00e0 condition que le port h\u00f4te, l'interface \u00e9lectrique et le module optique soient con\u00e7us pour prendre en charge des environnements mixtes.<\/strong> 802.3cd<\/p><\/li><li><p><strong>Cependant, PAM4 et NRZ ne peuvent pas interop\u00e9rer sur un seul lien ; les deux extr\u00e9mit\u00e9s doivent utiliser le m\u00eame format de modulation.<\/strong> comble le vide pour les Ethernet 50G par lane, \u00e0 une ou plusieurs lanes, permettant ainsi des chemins de migration \u00e9volutifs de 25G \u2192 50G \u2192 100G\/200G \u2192 400G.<\/p><\/li><li><p><strong>54. IEEE 802.3cd convient-il aux charges de travail AI\/ML et HPC de nouvelle g\u00e9n\u00e9ration ?<\/strong> Oui. L'architecture PAM4 50G par lane de la norme s'aligne avec les tissus \u00e0 haut d\u00e9bit utilis\u00e9s dans les clusters AI, les syst\u00e8mes HPC et les grands r\u00e9seaux GPU. Elle permet des topologies spine-leaf \u00e0 faible latence avec des options de breakout flexibles telles que 4\u00d750G ou 2\u00d7100G.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">LIEN-PP<\/a> Qu'est-ce que IEEE 802.3cd ?.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >D\u00e9couvrez ce que d\u00e9finit IEEE 802.3cd pour 50G, 100G et 200G Ethernet. Explorez la technologie PAM4, les PMD cl\u00e9s, les cas d'utilisation de d\u00e9ploiement et les transmetteurs optiques LINK-PP adapt\u00e9s.<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/ieee-802-3bs-200g-400g-ethernet-standard\/\"><strong>IEEE 802.3cd Expliqu\u00e9 : 50G, 100G &amp; 200G Ethernet avec PAM4<\/strong><\/a> ieee 802 3cd 50g 100g 200g pam4 ethernet.<\/p><\/li><li><p><strong>3cu<\/strong> \u00e9tend le 100G\/400G aux applications SMF \u00e0 port\u00e9e plus longue (DR\/FR\/LR).<\/p><\/li><li><p><strong>3cd<\/strong> comble l'\u00e9cart pour <strong>l'Ethernet 50G par voie unique et multi-voies<\/strong>, permettant des chemins de migration \u00e9volutifs du 25G \u2192 50G \u2192 100G\/200G \u2192 400G.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Le standard IEEE 802.3cd est-il adapt\u00e9 aux charges de travail AI\/ML et HPC de nouvelle g\u00e9n\u00e9ration ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Oui. L'architecture PAM4 de 50G par voie du standard <strong>s'aligne avec les tissus \u00e0 haut d\u00e9bit utilis\u00e9s dans les clusters AI,<\/strong> les syst\u00e8mes HPC, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/what-is-hpc-high-performance-computing\/\">et les r\u00e9seaux GPU \u00e0 grande \u00e9chelle. Il permet des topologies spine-leaf \u00e0 faible latence avec des options de breakout flexibles telles que 4\u00d750G ou 2\u00d7100G.<\/a>, Qu'est-ce que l'IEEE 802.3cd ?.<\/p>","protected":false},"excerpt":{"rendered":"<p>Explication de l'IEEE 802.3cd : Ethernet 50G, 100G &amp; 200G avec PAM4.<\/p>","protected":false},"author":1,"featured_media":3515,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13,24,26],"class_list":["post-3516","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules","tag-link-pp","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/3516","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/comments?post=3516"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/3516\/revisions"}],"predecessor-version":[{"id":11328,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/3516\/revisions\/11328"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media\/3515"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media?parent=3516"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/categories?post=3516"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/tags?post=3516"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}