{"id":2799,"date":"2026-03-30T00:00:00","date_gmt":"2026-03-30T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/qsfp-data-rate-explained-40g-100g-and-compatibility\/"},"modified":"2026-05-26T08:12:43","modified_gmt":"2026-05-26T08:12:43","slug":"qsfp-data-rate-explained-40g-100g-and-compatibility","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/qsfp-data-rate-explained-40g-100g-and-compatibility","title":{"rendered":"D\u00e9bit de donn\u00e9es QSFP expliqu\u00e9 : guide des vitesses de 40 G \u00e0 800 G"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"628\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c499fb237b464b90b37c8aa5e833f4d1.jpg\" alt=\"QSFP Data Rate Explained\" class=\"wp-image-2789\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c499fb237b464b90b37c8aa5e833f4d1.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c499fb237b464b90b37c8aa5e833f4d1-300x157.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c499fb237b464b90b37c8aa5e833f4d1-1024x536.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c499fb237b464b90b37c8aa5e833f4d1-768x402.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c499fb237b464b90b37c8aa5e833f4d1-18x9.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Les vitesses de donn\u00e9es QSFP varient de 40G \u00e0 800G selon la g\u00e9n\u00e9ration du module.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/491590.htm\"><strong>QSFP+<\/strong><\/a> prend en charge la transmission de donn\u00e9es \u00e0 <strong>40Gbps (4 \u00d7 10G)<\/strong><\/p><\/li><li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/491586.htm\"><strong>QSFP28<\/strong><\/a> prend en charge la transmission de donn\u00e9es \u00e0 <strong>100Gbps (4 \u00d7 25G)<\/strong><\/p><\/li><li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/473139.htm\"><strong>QSFP56<\/strong><\/a> prend en charge la transmission de donn\u00e9es \u00e0 <strong>200Gbps (4 \u00d7 50G, PAM4)<\/strong><\/p><\/li><li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472016.htm\"><strong>QSFP-DD<\/strong><\/a> prend en charge la transmission de donn\u00e9es \u00e0 <strong>400Gbps \u00e0 800Gbps (8 canaux, PAM4)<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">En termes simples, QSFP n'est pas une seule norme de vitesse ; il s'agit d'une forme factorielle scalamable utilis\u00e9e dans les centres de donn\u00e9es et les r\u00e9seaux t\u00e9l\u00e9coms. La bande passante totale est d\u00e9termin\u00e9e par la vitesse par canal \u00d7 le nombre de canaux, ce qui explique pourquoi les nouveaux mod\u00e8les atteignent des vitesses plus \u00e9lev\u00e9es sans changer radicalement l'interface physique. <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/491588.htm\">Modules QSFP<\/a> Ils atteignent des vitesses plus \u00e9lev\u00e9es sans changer radicalement l'interface physique.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pourquoi comprendre la vitesse de donn\u00e9es QSFP importe<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le choix du bon taux de donn\u00e9es QSFP est crucial pour :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>La performance r\u00e9seau et la scalabilit\u00e9<\/p><\/li><li><p>La compatibilit\u00e9 avec les commutateurs et ports<\/p><\/li><li><p>Les upgrads efficaces (40G \u2192 100G \u2192 400G)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Que vous soyez en conception d'un r\u00e9seau de centre de donn\u00e9es ou en upgrading des infrastructures existantes, comprendre l'\u00e9volution des taux de donn\u00e9es QSFP vous aidera \u00e0 \u00e9viter les probl\u00e8mes de compatibilit\u00e9 et \u00e0 optimiser votre investissement \u00e0 long terme.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ce que vous allez apprendre dans ce guide<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En lisant cet article, vous allez :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Comprendre pr\u00e9cis\u00e9ment les taux de donn\u00e9es de QSFP, QSFP+, QSFP28 et QSFP-DD<\/p><\/li><li><p>Comparer les architectures 40G vs. 100G vs. 400G vs. 800G<\/p><\/li><li><p>Apprendre comment la vitesse par canal et la modulation impactent la performance<\/p><\/li><li><p>Identifier le module QSFP le plus appropri\u00e9 pour votre sc\u00e9nario de d\u00e9ploiement<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Maintenant, nous allons d\u00e9tailler la famille QSFP et comment chaque g\u00e9n\u00e9ration d\u00e9finit son taux de donn\u00e9es.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a1\ufe0f\u00a0<\/strong>Qu'est-ce que QSFP ? Une famille de facteurs de haute vitesse<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>QSFP (transceiver \u00e0 facteur de forme r\u00e9duit quadruple)<\/strong> est un facteur de transceivers optique ou en cuivre utilisable pour transmettre des donn\u00e9es \u00e0 haute vitesse dans l'\u00e9quipement de r\u00e9seau tels que les commutateurs, les routeurs et les serveurs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La plus importante notion \u00e0 comprendre : QSFP n'est pas une vitesse fixe ; il s'agit d'une plateforme de mat\u00e9riel scalamable qui supporte plusieurs vitesses sur diff\u00e9rentes g\u00e9n\u00e9rations.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/35c5a71cd30045e0babd8986d37a6199.jpg\" alt=\"What Is QSFP? A Family of High-Speed Form Factors\" class=\"wp-image-2790\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/35c5a71cd30045e0babd8986d37a6199.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/35c5a71cd30045e0babd8986d37a6199-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/35c5a71cd30045e0babd8986d37a6199-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/35c5a71cd30045e0babd8986d37a6199-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/35c5a71cd30045e0babd8986d37a6199-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >QSFP = Form Factor, Not Speed<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">De nombreux utilisateurs supposent que \u201cQSFP\u201d \u00e9quivaut \u00e0 une vitesse sp\u00e9cifique (comme 40G), mais c'est faux.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Au lieu de cela, QSFP d\u00e9finit :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Une taille physique et une norme de connecteur standard<\/p><\/li><li><p>Une interface \u00e9lectrique multi-lane (typiquement 4 ou 8 canaux)<\/p><\/li><li><p>Un design pluggable pour les upgrads flexibles<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">La vitesse r\u00e9elle d\u00e9pend de la g\u00e9n\u00e9ration du module QSFP, pas du nom \u201cQSFP\u201d lui-m\u00eame.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Comment le QSFP r\u00e9alise diff\u00e9rentes vitesses de donn\u00e9es<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les modules QSFP utilisent une formule simple pour \u00e9voluer leur performance :<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Vitesse totale = Vitesse par canal \u00d7 Nombre de canaux<\/strong><\/p><\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">Par exemple :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>QSFP+ \u2192 4 canaux \u00d7 10G = 40G<\/p><\/li><li><p>QSFP28 \u2192 4 canaux \u00d7 25G = 100G<\/p><\/li><li><p>QSFP56 \u2192 4 canaux \u00d7 50G = 200G<\/p><\/li><li><p>QSFP-DD \u2192 8 canaux \u00d7 50G \/ 100G = 400G \/ 800G<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Cette architecture bas\u00e9e sur des canaux modulaires permet \u00e0 QSFP d'\u00e9voluer de 40G \u00e0 800G+ sans redessiner compl\u00e8tement l'interface.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Caract\u00e9ristiques cl\u00e9s des formes QSFP<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Haute densit\u00e9<\/strong><br\/>Les ports QSFP permettent plusieurs liens hauts de performances dans un espace compact, ce qui en fait id\u00e9aux pour les centres de donn\u00e9es.<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/are-sfp-modules-hot-swappable-safe-sfp-hot-swap-guide\/\"><strong>Rempla\u00e7able \u00e0 chaud<\/strong><\/a><strong> Design<\/strong><br\/>Les modules peuvent \u00eatre ins\u00e9r\u00e9s ou retir\u00e9s sans \u00e9teindre le syst\u00e8me.<\/p><\/li><li><p><strong>Compatibilit\u00e9 arri\u00e8re (partielle)<\/strong><br\/>Certaines g\u00e9n\u00e9rations de QSFP peuvent supporter des modules \u00e0 faible vitesse selon le design du commutateur.<\/p><\/li><li><p><strong>D\u00e9ploiement flexible<\/strong><br\/>Supporte des c\u00e2bles optiques et DAC (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/direct-attach-cables-dac-in-networking\/\">Raccordement cuivre direct<\/a>).<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Pourquoi QSFP est devenu le standard industriel<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP est largement adopt\u00e9 car il offre :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Bande passante scalamable (de 40G \u00e0 800G)<\/p><\/li><li><p>Co\u00fbt efficace par bit<\/p><\/li><li><p>Flexibilit\u00e9 pour les upgrads de r\u00e9seaux<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">C'est pourquoi QSFP domine aujourd'hui :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>R\u00e9seaux de centres de donn\u00e9es<\/p><\/li><li><p>Infrastructures cloud<\/p><\/li><li><p>Environnements de calcul haute performance (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/what-is-hpc-high-performance-computing\/\">HPC<\/a>)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP est un <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472118.htm\">transceivers pluggable<\/a> form factor qui supporte plusieurs vitesses de donn\u00e9es, pas une vitesse fixe<strong>.<\/strong> Sa performance s'\u00e9chelle en augmentant la vitesse du canal et le nombre de canaux \u00e0 travers les g\u00e9n\u00e9rations comme QSFP+, QSFP28 et QSFP-DD.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Maintenant, regardons \u00e0 la premi\u00e8re g\u00e9n\u00e9ration largement utilis\u00e9e : QSFP+ et sa vitesse de 40G.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a1\ufe0f\u00a0<\/strong>Quelle est la vitesse de donn\u00e9es de QSFP+ ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP+ supporte une vitesse de donn\u00e9es de 40Gbps (40G Ethernet). QSFP+ supporte 40Gbps en utilisant 4 canaux de 10Gbps chacun, ce qui en fait le transceiver standard pour les r\u00e9seaux Ethernet 40G.<br\/>Il atteint cela en utilisant une architecture de 4 canaux, o\u00f9 chaque canal fonctionne \u00e0 environ 10Gbps (4 \u00d7 10G). <\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0398208a5d984d2f9b91343cc4f6c730.jpg\" alt=\"What Is the Data Rate of QSFP+ ?\" class=\"wp-image-2791\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0398208a5d984d2f9b91343cc4f6c730.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0398208a5d984d2f9b91343cc4f6c730-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0398208a5d984d2f9b91343cc4f6c730-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0398208a5d984d2f9b91343cc4f6c730-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0398208a5d984d2f9b91343cc4f6c730-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Structure des canaux QSFP+<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP+ utilise NRZ (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/understanding-non-return-to-zero-in-digital-communication\/\">Non-Return-to-Zero<\/a>) modulation, qui transmet 1 bit par cycle de signal. La structure est :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Nombre total de canaux :<\/strong> 4<\/p><\/li><li><p><strong>Vitesse par canal :<\/strong> ~10.3125 Gbps<\/p><\/li><li><p><strong>Bande passante totale :<\/strong> ~40\u201341.25 Gbps<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Cette conception bas\u00e9e sur les voies d\u00e9finit la solution standard QSFP+ pour le r\u00e9seau 40G.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Applications typiques du QSFP+<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le QSFP+ est largement utilis\u00e9 dans :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Les couches d\u2019agr\u00e9gation du centre de donn\u00e9es<\/p><\/li><li><p>Les racks de bo\u00eetier (ToR)<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/what-is-a-tor-top-of-rack-switch\/\">Les connexions de bo\u00eetier \u00e0 rang\u00e9e (EoR)<\/a>Les interconnexions entre routeurs<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/end-of-row-eor-switches-architecture-benefits-and-deployment\/\">Les am\u00e9liorations du backbone entreprise de 10G vers 40G<\/a>Il est devenu populaire car il fournit 4 fois la bande large de<\/p><\/li><li><p>(10G) tout en maintenant un co\u00fbt et une consommation \u00e9nerg\u00e9tiques relativement basse.<\/p><\/li><li><p>Types courants de modules QSFP+<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Certains transceivers QSFP+ utilis\u00e9s de mani\u00e8re courante incluent : <a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-26192-10g-sfp.htm\">SFP+<\/a> Distance typique : jusqu\u2019\u00e0 100\u2013150m.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >40GBASE-LR4<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Distance typique : jusqu\u2019\u00e0 10km <a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-26153-40g-qsfp.htm\">40GBASE-CR4 (DAC)<\/a> Connexions \u00e0 faible distance, efficaces et \u00e0 faible co\u00fbt<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/482749.htm\"><strong>40GBASE-SR4<\/strong><\/a><\/p><ul><li><p>Fibre multimode (MMF)<\/p><\/li><li><p>Capacit\u00e9 de d\u00e9bordement QSFP+ (important)<\/p><\/li><\/ul><\/li><li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/482604.htm\"><strong>Une des principales avantages du QSFP+ est sa capacit\u00e9 \u00e0 d\u00e9bordner en plusieurs liens de faible vitesse :<\/strong><\/a><\/p><ul><li><p>Fibre monomode (SMF)<\/p><\/li><li><p>1 \u00d7 40G \u2192 4 \u00d7 10G (SFP+)<\/p><\/li><\/ul><\/li><li><p><strong>Cela est couramment utilis\u00e9 pour :<\/strong><\/p><ul><li><p>Raccordement cuivre direct<\/p><\/li><li><p>Augmenter la flexibilit\u00e9 des ports<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Connecter plusieurs serveurs 10G \u00e0 un port 40G du routeur<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Quand devriez-vous utiliser les modules QSFP+ ?<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Le QSFP+ reste pertinent pour :<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Les infrastructures 40G anciennes<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Les d\u00e9ploiements \u00e0 faible co\u00fbt<\/p><\/li><li><p>Les liens courts \u00e0 moyens de distance dans les r\u00e9seaux existants<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Toutefois, dans de nouvelles installations, de nombreuses r\u00e9seaux se dirigent vers :<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le QSFP28 100G<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Pour une meilleure scalabilit\u00e9<\/p><\/li><li><p>Une efficacit\u00e9 accrue par bit<\/p><\/li><li><p>Maintenant, voyons comment le QSFP28 augmente la vitesse de donn\u00e9es \u00e0 100G et pourquoi il a pris le relais comme standard dominante dans les centres de donn\u00e9es modernes.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Quelle est la vitesse de donn\u00e9es du QSFP28 ?<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/488422.htm\">Le QSFP28 supporte une vitesse de donn\u00e9es de 100Gbps (Ethernet 100G).<\/a> Le QSFP28 supporte 100Gbps en utilisant 4 voies de 25Gbps chacune, ce qui en fait le transceivers standard pour les r\u00e9seaux Ethernet 100G. Il atteint cela en utilisant une architecture \u00e0 4 voies, o\u00f9 chaque voie fonctionne \u00e0 environ 25Gbps (4 \u00d7 25G).<\/p><\/li><li><p>Explication de la structure des voies du QSFP28<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Le QSFP28 repose sur la m\u00eame forme physique que le QSFP+, mais augmente significativement la vitesse par voie :.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a1\ufe0f\u00a0<\/strong>~25.78125 Gbps<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">~100\u2013103 Gbps.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Modulation :.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/755f20a05f9a41c58cdd5e778578715d.jpg\" alt=\"What Is the Data Rate of QSFP28 ?\" class=\"wp-image-2792\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/755f20a05f9a41c58cdd5e778578715d.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/755f20a05f9a41c58cdd5e778578715d-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/755f20a05f9a41c58cdd5e778578715d-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/755f20a05f9a41c58cdd5e778578715d-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/755f20a05f9a41c58cdd5e778578715d-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >NRZ (dans la plupart des normes 100GBASE)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Cela permet au QSFP28 de fournir 2.5 fois la bande large du QSFP+ sans augmenter le nombre de voies.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Nombre total de canaux :<\/strong> 4<\/p><\/li><li><p><strong>Vitesse par canal :<\/strong> Pourquoi le QSFP28 a-t-il pris le relais comme standard pour les r\u00e9seaux 100G<\/p><\/li><li><p><strong>Bande passante totale :<\/strong> ~100\u2013103 Gbps<\/p><\/li><li><p><strong>Modulation:<\/strong> NRZ (in most 100GBASE standards)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">This allows QSFP28 to deliver 2.5\u00d7 the bandwidth of QSFP+ without increasing the number of lanes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Why QSFP28 Became the Standard for 100G<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP28 est largement adopt\u00e9 car il trouve le meilleur \u00e9quilibre entre :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Bande large (100G)<\/p><\/li><li><p>Densit\u00e9 de port (m\u00eame taille que QSFP+)<\/p><\/li><li><p>\u00c9fficience \u00e9nerg\u00e9tique par bit<\/p><\/li><li><p>\u00c9chelle \u00e9conomique \u00e0 partir de 40G<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Cela fait que le QSFP28 est la solution dominante pour les r\u00e9seaux de centre de donn\u00e9es, en particulier dans les architectures spine-leaf.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Applications typiques des modules QSFP28<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le QSFP28 est couramment utilis\u00e9 en :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u00c9tages spine et c\u0153ur du centre de donn\u00e9es<\/p><\/li><li><p>Interconnexions spine-leaf<\/p><\/li><li><p>Calcul haute performance (HPC)<\/p><\/li><li><p>Infrastructures cloud et hyperscale<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">C'est la voie d'upgrade par d\u00e9faut pour les r\u00e9seaux qui se d\u00e9placent de :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>10G \u2192 25G \u2192 100G<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Types courants des modules QSFP28<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Certains des plus largement utilis\u00e9s <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/482496.htm\">les transcepteurs QSFP28<\/a> Connexions \u00e0 faible distance, efficaces et \u00e0 faible co\u00fbt<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/473115.htm\"><strong>100GBASE-SR4<\/strong><\/a><\/p><ul><li><p>Fibre multimode (MMF)<\/p><\/li><li><p>Distance typique : jusqu'\u00e0 70-100m<\/p><\/li><\/ul><\/li><li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/488423.htm\"><strong>100GBASE-LR4<\/strong><\/a><\/p><ul><li><p>Fibre monomode (SMF)<\/p><\/li><li><p>1 \u00d7 40G \u2192 4 \u00d7 10G (SFP+)<\/p><\/li><\/ul><\/li><li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472577.htm\"><strong>100GBASE-CWDM4<\/strong><\/a><\/p><ul><li><p>SMF, optimis\u00e9 en co\u00fbt<\/p><\/li><li><p>Distance typique : jusqu'\u00e0 2km<\/p><\/li><\/ul><\/li><li><p><strong>100GBASE-CR4 (DAC)<\/strong><\/p><ul><li><p>C\u00e2ble en cuivre<\/p><\/li><li><p>Connectivit\u00e9 courte port\u00e9e, co\u00fbteuse<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Flexibilit\u00e9 et d\u00e9bordement QSFP28<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Une des grandes avantages du QSFP28 est sa flexibilit\u00e9 de d\u00e9bordement<strong>y<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>1 \u00d7 100G \u2192 4 \u00d7 25G (SFP28)<\/p><\/li><li><p>1 \u00d7 100G \u2192 2 \u00d7 50G (moins courant)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Cela permet :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Connectivit\u00e9 efficace aux serveurs<\/p><\/li><li><p>Migration progressive de 25G vers 100G<\/p><\/li><li><p>Meilleure utilisation de port dans les commutateurs haut densit\u00e9<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Pourquoi le QSFP28 est la voie d'upgrade la plus courante<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le QSFP28 est consid\u00e9r\u00e9 comme l'upgrade naturel du QSFP+ (40G) car :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Il utilise la m\u00eame taille physique du port<\/p><\/li><li><p>Il fournit 2,5 fois plus de bande large<\/p><\/li><li><p>Il s'aligne sur les syst\u00e8mes modernes de serveurs 25G <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/what-is-nic-network-interface-card\/\">NIC<\/a> \u00c9cosyst\u00e8mes<\/p><\/li><li><p>Il offre un co\u00fbt par Gbps plus bas \u00e0 long terme<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Pour la plupart des r\u00e9seaux, 100G est le point de soudage entre performance, co\u00fbt et scalamabilit\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ensuite, nous comparerons le QSFP, le QSFP+ et le QSFP28 c\u00f4te \u00e0 c\u00f4te pour mieux comprendre leurs taux de donn\u00e9es, structures de voies et cas d'utilisation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a1\ufe0f\u00a0<\/strong>QSFP, QSFP+, et QSFP28 diff\u00e8rent principalement en taux de donn\u00e9es et vitesse de voies : le QSFP supporte 4G (1G par voie), le QSFP+ supporte 40G (4 \u00d7 10G), et le QSFP28 supporte 100G (4 \u00d7 25G).<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP, QSFP+, and QSFP28 differ mainly in data rate and lane speed: QSFP supports 4G (1G per lane), QSFP+ supports 40G (4 \u00d7 10G), and QSFP28 supports 100G (4 \u00d7 25G).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Quand on compare les g\u00e9n\u00e9rations de QSFP, les diff\u00e9rences cl\u00e9s viennent de la vitesse de donn\u00e9es, la vitesse par canal et les sc\u00e9narios de d\u00e9ploiement typiques. Bien que tous partagent une forme physique similaire, leurs capacit\u00e9s de performance sont significativement diff\u00e9rentes.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/30a43cc56aad41dba0e1e6ccd181ae8f.jpg\" alt=\"QSFP+ vs. QSFP28: Speed, Lanes, and Use Cases\" class=\"wp-image-2793\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/30a43cc56aad41dba0e1e6ccd181ae8f.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/30a43cc56aad41dba0e1e6ccd181ae8f-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/30a43cc56aad41dba0e1e6ccd181ae8f-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/30a43cc56aad41dba0e1e6ccd181ae8f-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/30a43cc56aad41dba0e1e6ccd181ae8f-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Table Comparaison QSFP vs. QSFP+ vs. QSFP28<\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Type QSFP<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Vitesse de Donn\u00e9es Standard<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Vitesse Par Canal<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Nombre de Canaux<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Modulation<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Cas d\u2019utilisation typique<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>QSFP (ancien)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>NRZ<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Syst\u00e8mes anciens \/ t\u00e9l\u00e9coms<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>QSFP+<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>40G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>NRZ<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Agglom\u00e9ration dans les centres de donn\u00e9es, backbone 40G<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>QSFP28<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>100G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>25G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>NRZ<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Les centres de donn\u00e9es modernes, architectures spine-leaf<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Explication des Diff\u00e9rences Cl\u00e9s<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" >\u00c9volution de la Vitesse de Donn\u00e9es<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>QSFP \u2192 QSFP+ \u2192 QSFP28 repr\u00e9sente une voie d'am\u00e9lioration claire :<\/p><ul><li><p>4G \u2192 40G \u2192 100G<\/p><\/li><\/ul><\/li><li><p>Chaque g\u00e9n\u00e9ration augmente significativement la bande large sans changer la taille du port.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Cela permet aux op\u00e9rateurs de r\u00e9duire sans redessiner les layouts de l'\u00e9quipement.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >Am\u00e9lioration de la Vitesse Par Canal<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">La principale motivation de la vitesse de donn\u00e9es plus \u00e9lev\u00e9e est une signalisation plus rapide par canal :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>QSFP: <strong>1G par canal<\/strong><\/p><\/li><li><p>QSFP+: <strong>10G par canal<\/strong><\/p><\/li><li><p>QSFP28: <strong>25G par canal<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Au lieu d'ajouter plus de canaux, les g\u00e9n\u00e9rations plus r\u00e9centes am\u00e9liorent l'efficacit\u00e9 par canal, am\u00e9liorant ainsi le rendement et la performance de co\u00fbt.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >Technologie de Modulation<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Toutes les g\u00e9n\u00e9rations utilisent la modulation NRZ (Non-Return-to-Zero).<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>NRZ = 1 bit par cycle de signal<\/p><\/li><li><p>R\u00e9sultat fiable et simple, mais limit\u00e9 \u00e0 l'\u00e9chelle au-del\u00e0 de 25G par canal<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">C'est pourquoi de nouvelles normes (telles <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/qsfp56-optical-transceiver-overview-for-data-centers\/\">QSFP56<\/a>) se d\u00e9placent vers <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\">PAM4<\/a> pour des vitesses plus \u00e9lev\u00e9es.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >Sc\u00e9narios de D\u00e9ploiement<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>QSFP (ancien)<\/strong><br\/>Rares aujourd'hui, principalement trouv\u00e9s dans le mat\u00e9riel t\u00e9l\u00e9com ancien<\/p><\/li><li><p><strong>QSFP+ (40 G)<\/strong><\/p><ul><li><p>Agglom\u00e9ration d'entreprise<\/p><\/li><li><p>R\u00e9parations de centres de donn\u00e9es anciens<\/p><\/li><li><p>Environnements sensibles au co\u00fbt<\/p><\/li><\/ul><\/li><li><p><strong>QSFP28 (100G)<\/strong><\/p><ul><li><p>Architectures spine-leaf<\/p><\/li><li><p>Centres de donn\u00e9es hyperscalables<\/p><\/li><li><p>Calculs de performance \u00e9lev\u00e9s<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP28 domine les nouveaux d\u00e9ploiements, alors que QSFP+ est progressivement d\u00e9proportionn\u00e9.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>QSFP<\/strong> \u2192 Standard ancien, basse vitesse (4G)<\/p><\/li><li><p><strong>QSFP+<\/strong> \u2192 40G, largement utilis\u00e9 dans les syst\u00e8mes anciens et les r\u00e9seaux de niveau interm\u00e9diaire<\/p><\/li><li><p><strong>QSFP28<\/strong> \u2192 100G, standard actuel<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R\u00e9flexion Pratique pour les Acheteurs<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Si vous choisissez entre ces :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Choisissez seulement QSFP+ (40G) pour la compatibilit\u00e9 avec les syst\u00e8mes anciens<\/p><\/li><li><p>Choisissez QSFP28 (100G) pour les d\u00e9ploiements modernes<\/p><\/li><li><p>\u00c9vitez QSFP (ancien) sauf si n\u00e9cessaire pour les syst\u00e8mes plus anciens<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Cela garantit une meilleure scalabilit\u00e9 \u00e0 long terme et un retour sur investissement optimal.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ensuite, nous allons explorer comment choisir la vitesse de donn\u00e9es QSFP appropri\u00e9e pour votre environnement r\u00e9seau sp\u00e9cifique.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a1\ufe0f\u00a0<\/strong>Comment choisir la vitesse de donn\u00e9es QSFP pour votre r\u00e9seau<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Choisir la vitesse de donn\u00e9es QSFP n'est pas seulement question de choisir la plus rapide ; c'est aussi question de correspondre la bande passante \u00e0 votre couche de r\u00e9seau, aux patrons de trafic et \u00e0 votre strat\u00e9gie d'upgrade.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La meilleure approche consiste \u00e0 mapper les vitesses de donn\u00e9es QSFP aux sc\u00e9narios de d\u00e9ploiement r\u00e9els : acc\u00e8s, agr\u00e9gation et c\u0153ur.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e861cf5e60284b3292bf016597c0a527.jpg\" alt=\"How to Choose the Right QSFP Data Rate for Your Network\" class=\"wp-image-2795\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e861cf5e60284b3292bf016597c0a527.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e861cf5e60284b3292bf016597c0a527-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e861cf5e60284b3292bf016597c0a527-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e861cf5e60284b3292bf016597c0a527-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e861cf5e60284b3292bf016597c0a527-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Tableau de comparaison des vitesses de donn\u00e9es QSFP<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Choisir la vitesse de donn\u00e9es QSFP selon votre couche de r\u00e9seau : 40G pour les environnements legacy, 100G pour l'agr\u00e9gation et les centres de donn\u00e9es modernes, et 400G+ pour le c\u0153ur et les r\u00e9seaux hyperscale.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Type QSFP<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Vitesse standard Ethernet<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Vitesse de liaison \u00e9lectrique<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Modulation<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Nombre de Canaux<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Cas d\u2019utilisation typique<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>QSFP (ancien)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1G par canal<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>NRZ<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Syst\u00e8mes t\u00e9l\u00e9coms anciens<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>QSFP+<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>40G (40GbE)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10G par canal<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>NRZ<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Agr\u00e9gation des centres de donn\u00e9es<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>QSFP28<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>100G (100GbE)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>25G par canal<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>NRZ<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>R\u00e9seaux c\u0153ur et spine<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>QSFP28 (sortie)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 \u00d7 25G \/ 2 \u00d7 50G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>25G par canal<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>NRZ<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Connectivit\u00e9 serveur<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>QSFP56<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>200G (200GbE)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>50G par liaison<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>PAM4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Centres de donn\u00e9es haut densit\u00e9<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>QSFP112<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>400G (400GbE)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>100G par liaison<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>PAM4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>R\u00e9seaux hyperscale\/cloud<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>QSFP-DD<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>200G \/ 400G \/ 800G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>50G \/ 100G par liaison<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>PAM4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>8<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fabriques de routeurs de pointe<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Couche d'acc\u00e8s : 10G \/ 25G serveurs \u2192 40G ou 100G en uplinks<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Au niveau de l'acc\u00e8s (switches Top-of-Rack), le focus est sur la connectivit\u00e9 serveur et l'efficacit\u00e9 en termes de co\u00fbt.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Options QSFP recommand\u00e9es :<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/491589.htm\"><strong>QSFP+ 40 G<\/strong><\/a> \u2192 environnements legacy avec serveurs 10G<\/p><\/li><li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/473118.htm\"><strong>100 G QSFP28 <\/strong><\/a> \u2192 d\u00e9ploiements modernes avec serveurs 25G<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pourquoi :<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>40G supporte une sortie 4 \u00d7 10G<\/p><\/li><li><p>100G supporte une sortie 4 \u00d7 25G<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Si vos serveurs sont :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>NICs 10G \u2192 choisir 40G (QSFP+)<\/p><\/li><li><p>NICs 25G \u2192 choisir 100G (QSFP28)<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Couche d'agr\u00e9gation : \u00c9quilibrer le co\u00fbt et la bande passante<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Au niveau de l'agr\u00e9gation (leaves ou distribution), le trafic provenant de plusieurs switchs d'acc\u00e8s est combin\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Options QSFP recommand\u00e9es :<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>QSFP28 (100G)<\/strong> \u2192 la plus courante des choix<\/p><\/li><li><p><strong>QSFP56 (200G)<\/strong> \u2192 en croissance dans les environnements haut densit\u00e9<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pourquoi :<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Offre une capacit\u00e9 d'uplink plus \u00e9lev\u00e9e<\/p><\/li><li><p>R\u00e9duit les ratios d'overutilisation<\/p><\/li><li><p>Am\u00e9liore le rendement du trafic east-west<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">100G est actuellement le point de compromis id\u00e9al :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Co\u00fbt par Gbps<\/p><\/li><li><p>Densit\u00e9 de ports<\/p><\/li><li><p>\u00c9volutivit\u00e9<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Couche de c\u0153ur \/ spine : Haute capacit\u00e9 et scalamabilit\u00e9<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Au niveau du c\u0153ur (spine), le priorit\u00e9 est la capacit\u00e9 maximale et la pr\u00e9paration au futur.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Options QSFP recommand\u00e9es :<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>QSFP28 (100G)<\/strong> \u2192 le spine bas de gamme<\/p><\/li><li><p><strong>QSFP56 (200G)<\/strong> \u2192 la scalabilit\u00e9 interm\u00e9diaire<\/p><\/li><li><p><strong>QSFP-DD (400G \/ 800G)<\/strong> \u2192 les r\u00e9seaux hyperscale et les r\u00e9seaux de pointe<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pourquoi :<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Les liens centraux transportent un trafic agr\u00e9g\u00e9 provenant de l'ensemble du r\u00e9seau<\/p><\/li><li><p>Les vitesses plus \u00e9lev\u00e9es r\u00e9duisent les bottes de latence<\/p><\/li><li><p>Les futures am\u00e9liorations deviennent plus faciles avec des ports de capacit\u00e9 plus \u00e9lev\u00e9e<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">400G est devenu mainstream dans les hyperscalers<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">800G est en pleine \u00e9mergence pour <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/artificial-intelligence-what-it-is-and-how-it-works-explained\/\">AI<\/a> et des charges de performance \u00e9lev\u00e9es<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Les consid\u00e9rations de distance et de m\u00e9dia<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Votre taux de donn\u00e9es QSFP doit \u00e9galement aligner avec la distance et le type de c\u00e2ble :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Court terme (\u2264100m):<\/strong><\/p><ul><li><p>DAC (cuivre directement raccord\u00e9)<\/p><\/li><li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/473116.htm\">Les optiques SR<\/a> (MMF)<\/p><\/li><\/ul><\/li><li><p><strong>Moyen terme (\u22642km):<\/strong><\/p><ul><li><p>CWDM4 \/ PSM4<\/p><\/li><\/ul><\/li><li><p><strong>Long terme (10km+):<\/strong><\/p><ul><li><p>LR4 \/ <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472709.htm\">ER optiques<\/a> (SMF)<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Les vitesses plus \u00e9lev\u00e9es (200G\/400G) souvent n\u00e9cessitent :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Une meilleure qualit\u00e9 de fibre<\/p><\/li><li><p>Des optiques plus avanc\u00e9es (PAM4)<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >L'\u00e9quilibre entre co\u00fbt et la p\u00e9rennit\u00e9 des investissements<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Lors de la s\u00e9lection du taux de donn\u00e9es QSFP, il faut toujours \u00e9quilibrer :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Les contraintes budg\u00e9taires actuelles<\/p><\/li><li><p>Le d\u00e9veloppement du trafic de bande large<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>La strat\u00e9gie g\u00e9n\u00e9rale :<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>La mise en place \u00e0 court terme \u2192 choisir 40G \/ 100G<\/p><\/li><li><p>L'investissement \u00e0 long terme \u2192 consid\u00e9rer 100G \/ 400G<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Oublier les mises \u00e0 niveau interm\u00e9diaires (par exemple, passer directement de 40G \u00e0 100G) souvent entra\u00eene un co\u00fbt total de propri\u00e9t\u00e9 (TCO) inf\u00e9rieur.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Guide rapide des d\u00e9cisions<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>R\u00e9seaux petits \/ anciens : \u2192 QSFP+ (40G)<\/p><\/li><li><p>Les plus modernes : \u2192 QSFP28 (100G) <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/what-is-a-data-center\/\">centres de donn\u00e9es<\/a>Les plus hauts densit\u00e9s \/ AI \/ hyperscalers : \u2192 QSFP-DD (400G\/800G)<\/p><\/li><li><p>Il n'existe pas une solution \"une taille \u00e0 l'usage\" pour le taux QSFP.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">La bonne option d\u00e9pend de :.<br\/>Votre infrastructure actuelle<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Les attentes sur le d\u00e9veloppement du trafic<\/p><\/li><li><p>La timeline d'upgrade<\/p><\/li><li><p>Dans la plupart des cas, 100G (QSFP28) est le point de d\u00e9part optimal, avec un chemin clair d'upgrade vers 400G et au-del\u00e0.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Maintenant, nous aborderons un facteur critique que les acheteurs manquent souvent : la compatibilit\u00e9 QSFP, les modes de d\u00e9brayage et les correspondances de ports.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La compatibilit\u00e9 QSFP, les modes de d\u00e9brayage et les correspondances de ports<strong>.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a1\ufe0f\u00a0 <\/strong>Au-del\u00e0 du taux de donn\u00e9es, l'une des pr\u00e9occupations les plus importantes lors du travail avec les modules QSFP est la compatibilit\u00e9 avec les commutateurs, les optiques et l'infrastructure de c\u00e2blage. De nombreuses probl\u00e9matiques de mise en \u0153uvre r\u00e9elles proviennent de m\u00e9langes de port de vitesse, de type transceivers ou de configuration de d\u00e9brayage, pas de la bande passante elle-m\u00eame.<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u25b6 La compatibilit\u00e9 QSFP : Ce que vous devez savoir d'abord.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/f1b0e4ee902d434d96d89bdbe8588bc9.jpg\" alt=\"QSFP Compatibility, Breakout Modes, and Port Matching\" class=\"wp-image-2796\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/f1b0e4ee902d434d96d89bdbe8588bc9.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/f1b0e4ee902d434d96d89bdbe8588bc9-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/f1b0e4ee902d434d96d89bdbe8588bc9-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/f1b0e4ee902d434d96d89bdbe8588bc9-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/f1b0e4ee902d434d96d89bdbe8588bc9-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >La compatibilit\u00e9 QSFP d\u00e9pend de trois facteurs cl\u00e9s :<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La capacit\u00e9 du port du commutateur (support mat\u00e9riel)<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>La g\u00e9n\u00e9ration du transceiver (QSFP+, QSFP28, QSFP56, etc.)<\/p><\/li><li><p>La conformit\u00e9 de la marque ou de l'MSA<\/p><\/li><li><p>Vendor or MSA compliance<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Even si m\u00eame si la forme physique est la m\u00eame, un module QSFP+ ne fonctionne pas dans un port QSFP28 qu'ant une compatibilit\u00e9 invers\u00e9e, sauf si le switch supporte la compatibilit\u00e9 invers\u00e9e.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b6 Compatibilit\u00e9 Inverse et Forward<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La compatibilit\u00e9 QSFP n'est pas universelle, mais elle est souvent partiellement flexible :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Ports QSFP28<\/strong><\/p><ul><li><p>G\u00e9n\u00e9ralement supportent la QSFP28 (100G)<\/p><\/li><li><p>G\u00e9n\u00e9ralement supportent QSFP+ (40G) en mode r\u00e9duit (d\u00e9pendant du fabricant)<\/p><\/li><\/ul><\/li><li><p><strong>Ports QSFP+<\/strong><\/p><ul><li><p>G\u00e9n\u00e9ralement ne peuvent pas fonctionner \u00e0 la vitesse maximale QSFP28<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">R\u00e8gle cl\u00e9 :<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/how-to-test-sfp-compatibility\/\">Compatibilit\u00e9 <\/a>est d\u00e9termin\u00e9e par le port du switch, pas seulement par le module<\/p><\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">V\u00e9rifiez toujours le datasheet du switch avant de combiner des g\u00e9n\u00e9rations.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b6 Modes de Sortie : Un Port, Plusieurs Liaisons<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Une des fonctionnalit\u00e9s les plus puissantes du QSFP est la capacit\u00e9 de sortie, o\u00f9 une seule liaison haute vitesse est divis\u00e9e en plusieurs liaisons basse vitesse.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Exemples courants de sorties :<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>100G QSFP28 \u2192 4 \u00d7 25G SFP28<\/p><\/li><li><p>40G QSFP+ \u2192 4 \u00d7 10G SFP+<\/p><\/li><li><p>100G QSFP28 \u2192 2 \u00d7 50G (dans certaines architectures)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pourquoi la Sortie Est Importante<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La mode de sortie est largement utilis\u00e9e pour :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Optimisation de la connectivit\u00e9 serveur<\/p><\/li><li><p>\u00c9tendue r\u00e9seau progressive (10G \u2192 25G \u2192 100G)<\/p><\/li><li><p>Meilleure utilisation des ports sur les switches hauts de gamme<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Au lieu de d\u00e9ployer plusieurs ports de switch, la sortie permet \u00e0 un port haut de gamme de servir plusieurs points d'arriv\u00e9e.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b6 Mise en Correspondance des Ports : \u00c9viter les Erreurs de D\u00e9ploiement Comunes<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La mise en correspondance incorrecte est l'une des causes les plus courantes des probl\u00e8mes de d\u00e9ploiement QSFP.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R\u00e8gles cl\u00e9s :<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Mise en correspondance de la vitesse de donn\u00e9es au port du switch<\/p><ul><li><p>Le QSFP28 \u00e0 100G n\u00e9cessite un port capable de 100G<\/p><\/li><\/ul><\/li><li><p>Type optique de correspondance<\/p><ul><li><p>SR (MMF) \u2260 LR (SMF)<\/p><\/li><\/ul><\/li><li><p>Type de connecteur correspondant<\/p><ul><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/understanding-polarity-in-mtp-mpo-system-for-signal-integrity\/\">MPO<\/a> (optiques parall\u00e8les) \u2260 <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/sfp-duplex-lc-connector-explained\/\">LC<\/a> (optiques duplex)<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b6 Codage du fabricant et conformit\u00e9 MSA<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les modules QSFP modernes peuvent \u00eatre :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Compatibles MSA (multi-vendeur compatibles)<\/p><\/li><li><p>Vendor-coded (, etc.)<a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472659.htm\">Cisco<\/a>, <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472128.htm\">Juniper<\/a>, (MMF, SMF, etc.)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Le codage du fabricant affecte :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Si le module est reconnu par le switch<\/p><\/li><li><p>Avertissements d'alarme ou de compatibilit\u00e9<\/p><\/li><li><p>Acceptation du firmware<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Avant d'acheter des modules QSFP, v\u00e9rifiez :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u2714 Port du switch supporte la vitesse requise (40G \/ 100G \/ 400G)<\/p><\/li><li><p>\u2714 Les exigences de mode d\u00e9bordement (si n\u00e9cessaire)<\/p><\/li><li><p>\u2714 Type de fibre (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/fr\/knowledge-center\/smf-optical-transceiver-vs-mmf-optical-transceiver-guide\/\">Fibre multimode (MMF) vs. fibre monomode (SMF)<\/a>)<\/p><\/li><li><p>\u2714 Type de connecteur (SR, LR, DAC, AOC)<\/p><\/li><li><p>\u2714 Compatibilit\u00e9 ou support de d\u00e9bloquage du fabricant<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Les plus gros probl\u00e8mes avec les modules QSFP ne sont pas li\u00e9s \u00e0 la vitesse \u2014 ils sont li\u00e9s \u00e0 la compatibilit\u00e9 et au mappage de port. Comprendre le d\u00e9bordement et le mappage de port garantit :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Moins de d\u00e9faillances de d\u00e9ploiement<\/p><\/li><li><p>Meilleure efficacit\u00e9 de port<\/p><\/li><li><p>Co\u00fbt total inf\u00e9rieur de l'infrastructure<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a1\ufe0f\u00a0<\/strong>Conclusion : Quelle vitesse de donn\u00e9es QSFP devriez-vous choisir ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Choisir la bonne vitesse de donn\u00e9es QSFP d\u00e9pend finalement de votre \u00e9chelle r\u00e9seau, des exigences de performance et de la strat\u00e9gie de mise \u00e0 niveau. Bien que la technologie QSFP s'\u00e9tend de 40G \u00e0 800G, la meilleure option n'est pas toujours la plus \u00e9lev\u00e9e \u2014 c'est la plus \u00e9conomique et la plus future-pr\u00eat\u00e9e pour votre architecture.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >R\u00e9sum\u00e9 de la d\u00e9cision finale<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>QSFP+ (40 G)<\/strong><br\/>Id\u00e9al pour les environnements anciens, les upgrad\u00e9s de serveurs 10G et les d\u00e9ploiements sensibles au co\u00fbt. Toujours utilis\u00e9 dans les couches d'agglom\u00e9ration existantes des centres de donn\u00e9es.<\/p><\/li><li><p><strong>QSFP28 (100G)<\/strong><br\/>La norme principale, id\u00e9ale pour les architectures spine-leaf, les centres de donn\u00e9es modernes et les r\u00e9seaux d'entreprise scalaments.<\/p><\/li><li><p><strong>QSFP56 (200G)<\/strong><br\/>Id\u00e9al pour les environnements \u00e0 haute densit\u00e9 o\u00f9 la demande de bande largement croissante, en particulier dans le cloud et le calcul performant.<\/p><\/li><li><p><strong>QSFP-DD (400G \/ 800G)<\/strong><br\/>Con\u00e7u pour les centres de donn\u00e9es h\u00e9g\u00e9moniques, les charges d'AI et les r\u00e9seaux de c\u0153ur n\u00e9cessitant une capacit\u00e9 maximale de throughput.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Cadre de s\u00e9lection pratique<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pour choisir la bonne vitesse de donn\u00e9es QSFP, suivez cette r\u00e8gle simple :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Besoin en efficacit\u00e9 de co\u00fbt + support de l'ancien \u2192 40G (QSFP+)<\/p><\/li><li><p>Besoin en performance \u00e9quilibr\u00e9e + scalaments \u2192 100G (QSFP28)<\/p><\/li><li><p>Besoin en performance \u00e9lev\u00e9e pour le cloud \u2192 <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/473139.htm\">200G (QSFP56)<\/a><\/p><\/li><li><p>Besoin en bande de hyperscale ou de bande de niveau AI \u2192 400G\u2013800G (QSFP-DD)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Dans la plupart des d\u00e9ploiements r\u00e9els actuels, 100G (QSFP28) reste la meilleure option de base.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP n'est pas seulement sur la vitesse \u2014 c'est sur la strat\u00e9gie de d\u00e9veloppement du r\u00e9seau. Chaque g\u00e9n\u00e9ration construit sur la m\u00eame forme factorielle, permettant aux organisations de scaler la bande sans r\u00e9\u00e9crire compl\u00e8tement leur infrastructure.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/be042a1a002142d3a03db8c730d248dd.jpg\" alt=\"Which QSFP Data Rate Should You Choose?\" class=\"wp-image-2797\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/be042a1a002142d3a03db8c730d248dd.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/be042a1a002142d3a03db8c730d248dd-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/be042a1a002142d3a03db8c730d248dd-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/be042a1a002142d3a03db8c730d248dd-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/be042a1a002142d3a03db8c730d248dd-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Recommandation finale<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Si vous pr\u00e9voyez une nouvelle d\u00e9ploiement ou une mise \u00e0 niveau en 2026, priorisez :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>La compatibilit\u00e9 avec votre plateforme de switch<\/p><\/li><li><p>Un chemin clair de mise \u00e0 niveau (40G \u2192 100G \u2192 400G)<\/p><\/li><li><p>Le co\u00fbt total de l'exploitation (TCO), pas seulement la bande<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Pour garantir une performance stable et une compatibilit\u00e9 compl\u00e8te, toujours choisissez des composants fiables, compatibles MSA et fournisseurs reconnus. <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/491587.htm\">Modules QSFP<\/a> \ud83d\udc49 Explorez des transceivers et solutions optiques de qualit\u00e9 sup\u00e9rieure et test\u00e9es \u00e0 la fois \u00e0.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">, o\u00f9 vous pouvez trouver les modules QSFP+, QSFP28 et les modules de g\u00e9n\u00e9ration suivante con\u00e7us pour les applications de transport et des centres de donn\u00e9es. <a target=\"_self\" href=\"https:\/\/www.l-p.com\/\"><strong>Boutique officielle LINK-PP<\/strong><\/a>, Explication de la vitesse de donn\u00e9es QSFP.<\/p>","protected":false},"excerpt":{"rendered":"<p>Comprenez le d\u00e9bit de donn\u00e9es QSFP, de 40 G \u00e0 800 G, y compris les normes QSFP+, QSFP28 et QSFP-DD. Comparez les vitesses, la structure des voies et choisissez le module adapt\u00e9.<\/p>","protected":false},"author":1,"featured_media":2798,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13,17,18],"class_list":["post-2799","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules","tag-400g-optical-modules","tag-40g-qsfp-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/2799","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/comments?post=2799"}],"version-history":[{"count":2,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/2799\/revisions"}],"predecessor-version":[{"id":8142,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/posts\/2799\/revisions\/8142"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media\/2798"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/media?parent=2799"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/categories?post=2799"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/fr\/wp-json\/wp\/v2\/tags?post=2799"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}