{"id":5436,"date":"2025-08-15T00:00:00","date_gmt":"2025-08-15T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/psm4-vs-cwdm4-which-optical-transceiver-for-your-network\/"},"modified":"2026-06-22T08:25:49","modified_gmt":"2026-06-22T08:25:49","slug":"psm4-vs-cwdm4-which-optical-transceiver-for-your-network","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/psm4-vs-cwdm4-which-optical-transceiver-for-your-network","title":{"rendered":"PSM4 frente a CWDM4: \u00bfqu\u00e9 transceptor \u00f3ptico es el adecuado para su red?"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9.webp\" alt=\"100G PSM4 VS CWDM4\" class=\"wp-image-5432\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">La demanda de conectividad 100G en centros de datos y redes empresariales est\u00e1 experimentando un crecimiento explosivo. Elegir el adecuado<br> <strong>transceptor \u00f3ptico<\/strong> <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>(QSFP28 de 100G)<br><\/strong><\/a> es fundamental para el rendimiento, el costo, la escalabilidad y la eficiencia energ\u00e9tica. Dos est\u00e1ndares dominantes<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/multi-source-agreements-optical-transceivers\/\"><strong>y MSA<\/strong><\/a> (Acuerdo Multifabricante, MSA)<br> <strong>PSM4 (fibra monomodo paralela de 4 canales)<br><\/strong> and <strong>CWDM4 (multiplexaci\u00f3n por divisi\u00f3n de longitud de onda gruesa de 4 canales)<br><\/strong>. Aunque ambos logran 100G a 2 km mediante fibra monomodo<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/what-is-single-mode-fiber-and-how-does-it-work\/\"><strong>(FMU)<\/strong><\/a>, sus tecnolog\u00edas subyacentes y casos de uso ideales difieren significativamente. Comprender estas diferencias entre transceptores de 100G es clave para optimizar las redes de centros de datos y reducir los costos de los interconectores \u00f3pticos.<br>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udd27 PSM4: Potencia de la paralelizaci\u00f3n<br><\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"618\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda.webp\" alt=\"100G PSM4\" class=\"wp-image-5433\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda-300x155.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda-1024x527.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda-768x396.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda-18x9.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">PSM4 (IEEE 802.3bm) adopta un enfoque paralelo directo:<br><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Tecnolog\u00eda:<\/strong> Utiliza 4 canales \u00f3pticos independientes (cada uno a<br> <em>Longitud de onda de 1310 nm<\/em>).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fibra:<\/strong> Requiere <strong>8 fibras<\/strong> (4 emisores, 4 receptores) \u2014normalmente en un conector MPO-12.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Funcionamiento:<br><\/strong> Cada canal transmite simult\u00e1neamente datos a 25 Gbps sobre su par de fibras dedicado.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fortalezas:<\/strong> Dise\u00f1o \u00f3ptico m\u00e1s sencillo que potencialmente reduce los costos de los componentes y ofrece una excelente aislamiento de se\u00f1al.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Debilidades:<br><\/strong> Mayor consumo de fibras y mayor volumen del cable.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Ideal para:<\/strong> Alcance ultra corto (\u2264 500 m) dentro de racks o filas; escenarios de conexi\u00f3n directa de alta densidad donde el n\u00famero de fibras no es una restricci\u00f3n principal. Un m\u00f3dulo \u00f3ptico<br> <strong>PSM4<br><\/strong> como la <strong>LINK-PP LQ-M31100-DR4C<br><\/strong> ofrece un rendimiento constante para estas exigentes<br> <strong>aplicaciones de \u00f3ptica paralela<br><\/strong>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83c\udf08 CWDM4: Magia de las longitudes de onda<br><\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b.webp\" alt=\"100G CWDM4\" class=\"wp-image-5434\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">CWDM4 (Especificaci\u00f3n MSA) aprovecha la multiplexaci\u00f3n \u00f3ptica para ahorrar fibras:<br><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Tecnolog\u00eda:<\/strong> Utiliza 4 longitudes de onda diferentes de CWDM (~1271 nm, 1291 nm, 1311 nm, 1331 nm) multiplexadas sobre un<br> <em>\u00fanica<\/em> par de fibras.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fibra:<\/strong> Requiere \u00fanicamente<br> <strong>2 fibras<\/strong> (1 emisor, 1 receptor) \u2014normalmente con conectores LC d\u00faplex.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Funcionamiento:<br><\/strong> Un multiplexor (Mux) combina las 4 longitudes de onda sobre la fibra de transmisi\u00f3n; un demultiplexor (Demux) las separa en el extremo receptor.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fortalezas:<\/strong> Reduce dr\u00e1sticamente el n\u00famero de fibras (4 veces menos que PSM4), cables m\u00e1s peque\u00f1os, gesti\u00f3n de cables m\u00e1s sencilla y conectores LC est\u00e1ndar.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Debilidades:<br><\/strong> Requiere l\u00e1seres y componentes Mux\/Demux m\u00e1s complejos (y potencialmente m\u00e1s costosos).<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Ideal para:<\/strong> The <strong>punto \u00f3ptimo para la mayor\u00eda de enlaces de 100G a 2 km<br><\/strong> (p. ej., interconexi\u00f3n intra-centro de datos, enlaces campus). Es la soluci\u00f3n preferida para<br> <strong>eficiencia de fibra CWDM4 <\/strong> and <strong>conectividad 100G rentable<\/strong>. El <strong>LINK-PP <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472577.htm\"><strong>LQ-CW100-FR4C<\/strong><\/a> est\u00e1 dise\u00f1ado para una fiabilidad m\u00e1xima en estas redes multiplexadas por longitud de onda.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83e\udd4a Cara a cara: PSM4 frente a CWDM4 \u2013 Las diferencias clave<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Caracter\u00edstica<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>PSM4 (100G-PSM4)<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4 (100G-CWDM4)<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Ganador en\u2026<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Tecnolog\u00eda<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 canales paralelos a 1310 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 canales WDM (1271\/1291\/1311\/1331 nm)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Simplicidad (PSM4) \/ Eficiencia en fibra (CWDM4)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>N\u00famero de fibras<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>8 fibras<\/strong> (MPO-12)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>2 fibras<\/strong> (LC Duplex)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4<\/strong> (Ahorros significativos)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Recorrido<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Hasta 500 m (\u00f3ptimo), 2 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Hasta 2 km (est\u00e1ndar)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Empate (ambos alcanzan 2 km; PSM4 es mejor \u2264 500 m)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Conector<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>MPO-12\/APC<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>LC d\u00faplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4<\/strong> (Est\u00e1ndar, gesti\u00f3n m\u00e1s sencilla)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Complejidad del l\u00e1ser<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>M\u00e1s sencillo (4\u00d7 la misma \u03bb)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>M\u00e1s complejo (4\u00d7 longitudes de onda distintas, multiplexor\/demultiplexor)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>PSM4<\/strong> (Potencialmente menor costo)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Volumen del cable<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Mayor (cable m\u00e1s grueso)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Menor (cable m\u00e1s delgado)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Caso de uso principal<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Alcance corto, alta densidad<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Interconexi\u00f3n entre centros de datos (ICI) y entre centros de datos (DCI) est\u00e1ndar de 2 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Depende de la distancia y las necesidades de fibra<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Factor de costo (componentes)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Potencialmente menor costo del l\u00e1ser<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Potencialmente mayor costo del l\u00e1ser + multiplexor\/demultiplexor<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Depende del contexto<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Factor de costo (infraestructura)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Mayor (m\u00e1s fibra\/cableado)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Lower<\/strong> (Menos fibra\/cableado)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4<\/strong> (Costo total de infraestructura)<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83c\udfc6 Elegir a su campe\u00f3n: \u00bfPSM4 o CWDM4?<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px 0px 4px;\"><strong>Elija PSM4 si:<\/strong><\/p><ul><li><p style=\"margin: 0px;\">Sus enlaces sean <strong>la distancia es muy corta (\u2264 500 m)<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>la infraestructura de fibra es abundante y econ\u00f3mica<\/strong>, y el volumen del cable no constituye un problema importante.<\/p><\/li><li><p style=\"margin: 0px;\">Prioriza potenciales <strong>ahorros en costos de componentes<\/strong> frente a la eficiencia en fibra <em>para implementaciones espec\u00edficas de corto alcance<\/em>.<\/p><\/li><li><p style=\"margin: 0px;\">Necesita <strong>\u00f3ptica paralela de alta densidad<\/strong> dentro de un espacio reducido.<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>Elija CWDM4 si (la opci\u00f3n m\u00e1s com\u00fan):<\/strong><\/p><ul><li><p style=\"margin: 0px;\">Sus enlaces sean <strong>hasta 2 km<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>la conservaci\u00f3n de fibra es cr\u00edtica<\/strong> (ahorra costos y complejidad significativos).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Gesti\u00f3n de cables m\u00e1s sencilla<\/strong> se prefiere el conector LC d\u00faplex.<\/p><\/li><li><p style=\"margin: 0px;\">Necesita una <strong>soluci\u00f3n est\u00e1ndar y ampliamente interoperable<\/strong> para interconexiones entre centros de datos (DCI) o enlaces troncales empresariales.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Costo total de la infraestructura<\/strong> (fibra + cableado + gesti\u00f3n) es un factor determinante.<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\ud83d\udca1 Soluciones LINK-PP: Dise\u00f1adas para rendimiento y valor<\/strong><br\/>Ya sea que su dise\u00f1o de red 100G requiera la eficiencia paralela de <strong>PSM4<\/strong> o la potencia de multiplexaci\u00f3n por longitud de onda de <strong>CWDM4<\/strong>,<a target=\"_blank\" rel=\"\" href=\"https:\/\/www.link-pp.com\/\"><strong> LINK-PP<\/strong><\/a> ofrece soluciones de alto rendimiento y compatibles con el est\u00e1ndar MSA:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Para paralelismo exigente de corto alcance:<\/strong> The <strong>los transceptores LINK-PP PSM4<\/strong> ofrecen un rendimiento robusto para \u00f3ptica 100G rentable en aplicaciones densas y de corta distancia.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Para interconexi\u00f3n eficiente de 2 km:<\/strong> <strong>LINK-PP<\/strong> proporciona fiabilidad y bajo consumo de energ\u00eda <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472577.htm\"><strong>100G<\/strong> <strong>transceptores CWDM4<\/strong><\/a> optimizado para soluciones escalables de centros de datos y redes empresariales de alto ancho de banda.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ambos m\u00f3dulos pasan por pruebas rigurosas <strong>de transceptores \u00f3pticos<\/strong> para garantizar compatibilidad, bajo <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/understanding-what-is-bit-error-rate\/\"><strong>tasa de error de bits (BER)<\/strong><\/a>, y durabilidad, lo que le brinda confianza en su infraestructura de red \u00f3ptica.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Conclusi\u00f3n: Optimizaci\u00f3n de su borde \u00f3ptico<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Comprender los <strong>diferencias entre PSM4 y CWDM4<\/strong> es fundamental para tomar decisiones informadas <strong>sobre la selecci\u00f3n de transceptores de 100 G<\/strong>. Si bien PSM4 ofrece simplicidad para recorridos paralelos ultra cortos, <strong>CWDM4 se ha convertido en el est\u00e1ndar dominante para enlaces de 100 G a 2 km debido a su mayor eficiencia en fibra, gesti\u00f3n m\u00e1s sencilla y menores costos generales de infraestructura.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u00bfListo para optimizar su implementaci\u00f3n de 100 G con la soluci\u00f3n \u00f3ptica adecuada? \ud83d\udd17<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\ud83d\udc49 Explore la gama completa de m\u00f3dulos QSFP28 de alto rendimiento y alta confiabilidad de LINK-PP, incluidos nuestros transceptores CWDM4 l\u00edderes en la industria y transceptores PSM4, dise\u00f1ados para ofrecer el m\u00e1ximo valor y tiempo de actividad para sus enlaces cr\u00edticos. <\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>Visite nuestra p\u00e1gina de productos \u279e<\/strong><\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Preguntas frecuentes<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfCu\u00e1l es la diferencia principal entre PSM4 y CWDM4?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PSM4 necesita ocho fibras y utiliza conectores MPO\/MTP. Env\u00eda datos en paralelo. CWDM4 solo necesita dos fibras y utiliza conectores d\u00faplex LC. Env\u00eda datos mediante diferentes longitudes de onda.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>PSM4 es adecuado para enlaces cortos. CWDM4 es mejor para distancias m\u00e1s largas.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfQu\u00e9 transceptor es m\u00e1s f\u00e1cil de instalar en redes existentes?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">CWDM4 suele ser m\u00e1s f\u00e1cil de instalar. La mayor\u00eda de las redes ya utilizan conectores LC y cables de dos fibras.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>PSM4 podr\u00eda requerir nueva fibra paralela si no la tiene.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfQu\u00e9 opci\u00f3n es m\u00e1s rentable para distancias cortas?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PSM4 suele costar menos para enlaces cortos si ya dispone de fibra paralela.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>CWDM4 puede ahorrar dinero en cables para redes nuevas o de mayor tama\u00f1o.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfPueden ambos transceptores PSM4 y CWDM4 soportar futuras actualizaciones de red?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">CWDM4 es mejor para actualizaciones. Utiliza menos fibras, por lo que agregar m\u00e1s es sencillo.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>PSM4 podr\u00eda requerir m\u00e1s espacio a medida que su red crece.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfQu\u00e9 transceptor debe elegir un centro de datos para enlaces largos?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un centro de datos debe elegir CWDM4 para enlaces de hasta 2 kil\u00f3metros.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>PSM4 es ideal para enlaces cortos dentro de un edificio.<\/p><\/blockquote>","protected":false},"excerpt":{"rendered":"<p>Compare PSM4 con CWDM4 para elegir el transceptor \u00f3ptico de 100G adecuado para su red seg\u00fan distancia, cableado, costo y necesidades de actualizaci\u00f3n.<\/p>","protected":false},"author":1,"featured_media":5435,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13],"class_list":["post-5436","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/5436","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/comments?post=5436"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/5436\/revisions"}],"predecessor-version":[{"id":11253,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/5436\/revisions\/11253"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/media\/5435"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/media?parent=5436"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/categories?post=5436"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/tags?post=5436"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}