{"id":5280,"date":"2025-09-01T00:00:00","date_gmt":"2025-09-01T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/optical-transceiver-insertion-loss-definition-impact\/"},"modified":"2026-06-22T07:58:23","modified_gmt":"2026-06-22T07:58:23","slug":"optical-transceiver-insertion-loss-definition-impact","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/optical-transceiver-insertion-loss-definition-impact","title":{"rendered":"P\u00e9rdida de inserci\u00f3n del transceptor \u00f3ptico: definici\u00f3n, medici\u00f3n e impacto"},"content":{"rendered":"<h2 class=\"wp-block-heading\" >\u25b6 Introducci\u00f3n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">En la comunicaci\u00f3n \u00f3ptica, cada fracci\u00f3n de decibelio puede decidir si un enlace funciona perfectamente o falla bajo carga. Uno de los par\u00e1metros m\u00e1s importantes es <strong>la p\u00e9rdida de inserci\u00f3n (IL)<\/strong> \u2014la cantidad de potencia \u00f3ptica perdida cuando la luz atraviesa un componente, conector o enlace de fibra. Los ingenieros consideran la p\u00e9rdida de inserci\u00f3n una medici\u00f3n fundamental al calcular los presupuestos de enlace, probar instalaciones de fibra y seleccionar <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">transceptores \u00f3pticos<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Este art\u00edculo explica qu\u00e9 es la p\u00e9rdida de inserci\u00f3n, c\u00f3mo se mide, qu\u00e9 aspecto tienen sus valores t\u00edpicos y por qu\u00e9 es importante para el rendimiento de los m\u00f3dulos \u00f3pticos, como los suministrados por <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/page\/aboutus.htm\"><strong>LINK-PP<\/strong><\/a>.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/283194d74a2a4ae4857bfb467fb58fca.webp\" alt=\"Optical transceiver insertion loss visualized across LC and MPO connectors in a data center link\" class=\"wp-image-5276\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/283194d74a2a4ae4857bfb467fb58fca.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/283194d74a2a4ae4857bfb467fb58fca-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/283194d74a2a4ae4857bfb467fb58fca-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/283194d74a2a4ae4857bfb467fb58fca-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/283194d74a2a4ae4857bfb467fb58fca-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 \u00bfQu\u00e9 es la \u201cp\u00e9rdida de inserci\u00f3n del transceptor \u00f3ptico\u201d?<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Definici\u00f3n en t\u00e9rminos sencillos<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La p\u00e9rdida de inserci\u00f3n es la reducci\u00f3n de la potencia de la se\u00f1al entre la entrada y la salida de un componente o enlace. Siempre se expresa en <strong>decibelios (dB)<\/strong>. Una IL menor significa que llega m\u00e1s luz al receptor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Matem\u00e1ticamente:<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"320\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/222f8c7683aa4833bd4b9e10f9448198.webp\" alt=\"Optical Transceiver Insertion Loss\" class=\"wp-image-5277\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/222f8c7683aa4833bd4b9e10f9448198.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/222f8c7683aa4833bd4b9e10f9448198-300x80.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/222f8c7683aa4833bd4b9e10f9448198-1024x273.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/222f8c7683aa4833bd4b9e10f9448198-768x205.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/222f8c7683aa4833bd4b9e10f9448198-18x5.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Donde:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Pin<\/strong> = potencia \u00f3ptica de entrada<\/p><\/li><li><p><strong>Pout<\/strong> = potencia \u00f3ptica de salida<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Si inyecta \u20132 dBm en una fibra y recibe \u20132.5 dBm en el extremo opuesto, la p\u00e9rdida de inserci\u00f3n es de 0.5 dB.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >Por qu\u00e9 importa la IL<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Dado que los receptores \u00f3pticos requieren una potencia de entrada m\u00ednima determinada para funcionar correctamente, un exceso de IL reduce directamente el margen del sistema y puede hacer que el receptor caiga por debajo del umbral de sensibilidad. Esto provoca mayores <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/understanding-what-is-bit-error-rate\/\">tasas de error de bit (BER)<\/a> o incluso desconexiones.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Causas de la p\u00e9rdida de inserci\u00f3n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La p\u00e9rdida de inserci\u00f3n es inevitable, pero se puede minimizar mediante un buen dise\u00f1o y mantenimiento. Los principales factores contribuyentes incluyen:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>P\u00e9rdida por acoplamiento de conectores<\/strong> \u2014 Peque\u00f1os huecos, desalineaci\u00f3n o suciedad entre dos conectores de fibra aumentan la p\u00e9rdida.<\/p><\/li><li><p><strong>Atenuaci\u00f3n de la fibra<\/strong> \u2014 Incluso la fibra monomodo de alta calidad presenta una atenuaci\u00f3n inherente (p. ej., ~0.35 dB\/km a 1310 nm, ~0.2 dB\/km a 1550 nm).<\/p><\/li><li><p><strong>P\u00e9rdida por empalme<\/strong> \u2014 Los empalmes mec\u00e1nicos o por fusi\u00f3n suelen a\u00f1adir de 0.05 a 0.3 dB.<\/p><\/li><li><p><strong>P\u00e9rdida por curvatura<\/strong> \u2014 Las curvaturas bruscas o microcurvaturas provocan fugas de se\u00f1al.<\/p><\/li><li><p><strong>P\u00e9rdidas internas en los m\u00f3dulos<\/strong> \u2014 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475859.htm\">Transceptores \u00f3pticos<\/a> tienen lentes e interfaces integradas que a\u00f1aden peque\u00f1os valores de IL.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 C\u00f3mo medir la p\u00e9rdida de inserci\u00f3n<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Conjunto de prueba de p\u00e9rdida \u00f3ptica (OLTS)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La forma m\u00e1s precisa de medir la p\u00e9rdida de inserci\u00f3n (IL) es con un OLTS: una fuente de luz calibrada en un extremo del enlace y un medidor de potencia en el otro. Este es el est\u00e1ndar <strong>Prueba de certificaci\u00f3n de nivel 1<\/strong> en fibra \u00f3ptica.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pasos:<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>Conecte la fuente y el medidor con un cable de referencia conocido.<\/p><\/li><li><p>Mida la potencia de referencia (Pin).<\/p><\/li><li><p>Conecte el enlace de fibra a probar.<\/p><\/li><li><p>Mida la potencia de salida (Pout).<\/p><\/li><li><p>Calcule la IL = 10\u00b7log<sub>10<\/sub>(Pin\/Pout).<\/p><\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" >OTDR (Reflect\u00f3metro en el dominio del tiempo \u00f3ptico)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un OTDR tambi\u00e9n puede estimar la IL, pero se usa principalmente para localizar fallas. Para pruebas de aceptaci\u00f3n, se prefiere el OLTS.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Consejos para pruebas en campo<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Limpie siempre los conectores antes de probar: la contaminaci\u00f3n es la causa n.\u00ba 1 de p\u00e9rdida excesiva.<\/p><\/li><li><p>Pruebe en ambas direcciones (A\u2192B y B\u2192A) y promedie los resultados.<\/p><\/li><li><p>Use cables de referencia de alta calidad con una IL conocida y baja.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Valores t\u00edpicos de p\u00e9rdida de inserci\u00f3n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Los valores t\u00edpicos de IL ayudan a los ingenieros a dise\u00f1ar los presupuestos de enlace:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Conector individual:<\/strong> 0,1\u20130,5 dB (pulido adecuado y limpio).<\/p><\/li><li><p><strong>Empalme mec\u00e1nico:<\/strong> 0,2\u20130,5 dB.<\/p><\/li><li><p><strong>Empalme por fusi\u00f3n:<\/strong> 0,05\u20130,1 dB.<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482604.htm\"><strong>Direct Attach Copper (DAC)<\/strong><\/a><strong> Atenuaci\u00f3n:<\/strong> 0,35 dB\/km a 1310 nm, 0,2 dB\/km a 1550 nm.<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/488477.htm\"><strong>Fibra multimodo<\/strong><\/a><strong> Atenuaci\u00f3n:<\/strong> 3,0 dB\/km a 850 nm, 1,0 dB\/km a 1300 nm.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Por ejemplo, un enlace monomodo de 10 km a 1550 nm con dos conectores y dos empalmes podr\u00eda tener una IL total \u2248 0,2 \u00d7 10 + 0,3 + 0,1 = 2,4 dB.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 P\u00e9rdida de inserci\u00f3n en los c\u00e1lculos del presupuesto de enlace<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">El presupuesto de enlace es la diferencia entre la potencia de salida del transmisor y la sensibilidad del receptor, ajustada por la IL y el margen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ejemplo:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Potencia del transmisor (Tx): 0 dBm<\/p><\/li><li><p>Sensibilidad del receptor (Rx): \u201314 dBm<\/p><\/li><li><p>Presupuesto disponible = 14 dB<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Si la IL = 10 dB, el margen = 4 dB \u2192 <strong>aceptable<\/strong>.<br\/>Si la IL = 15 dB, el margen = \u20131 dB \u2192 <strong>el enlace falla<\/strong>.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Esto muestra por qu\u00e9 incluso fracciones de dB son importantes.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Impacto sobre los transceptores \u00f3pticos<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La p\u00e9rdida de inserci\u00f3n afecta <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">m\u00f3dulos \u00f3pticos<br><\/a> de tres maneras principales:<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p><strong>Margen reducido:<\/strong> Una IL elevada reduce el margen disponible del sistema, dejando al enlace vulnerable al envejecimiento o a cambios de temperatura.<\/p><\/li><li><p><strong>Mayor tasa de errores de bits (BER):<\/strong> Una relaci\u00f3n se\u00f1al-ruido m\u00e1s baja en el receptor implica m\u00e1s errores de bit.<\/p><\/li><li><p><strong>Alcance reducido:<\/strong> Un m\u00f3dulo clasificado para 40 km podr\u00eda alcanzar solo 30 km si la IL supera los valores supuestos.<\/p><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Por ejemplo, LINK-PP\u2019s <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482907.htm\"><strong>LS-CW3110-40I<\/strong><\/a><strong> transceptor \u00f3ptico<\/strong> est\u00e1 dise\u00f1ado para transmisi\u00f3n de 10 G a 40 km. Si se implementa con una p\u00e9rdida de inserci\u00f3n (IL) excesiva (conectores sucios, empalmes deficientes), su alcance efectivo se reducir\u00e1. Por lo tanto, verificar la IL forma parte de garantizar un rendimiento acorde con las especificaciones t\u00e9cnicas.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 C\u00f3mo minimizar la p\u00e9rdida de inserci\u00f3n<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Limpie los conectores<\/strong> antes de cada uso con pa\u00f1os sin pelusas y alcohol isoprop\u00edlico.<\/p><\/li><li><p><strong>Inspeccione las caras extremas<\/strong> con un microscopio de fibra.<\/p><\/li><li><p><strong>Utilice empalme por fusi\u00f3n<\/strong> en lugar de empalme mec\u00e1nico siempre que sea posible.<\/p><\/li><li><p><strong>Evite curvaturas pronunciadas<\/strong> \u2014 respete el radio de curvatura de la fibra.<\/p><\/li><li><p><strong>Elija componentes de calidad<\/strong> \u2014 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">m\u00f3dulos<\/a>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-21644-fiber-optic-cages-connectors.htm\">conectores<\/a>, and <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26454-dac-aoc-aec-cables.htm\">cables de conexi\u00f3n<\/a> con especificaciones garantizadas de p\u00e9rdida de inserci\u00f3n (IL).<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 D\u00f3nde ayuda LINK-PP<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d9cc5ec3f48c48f3b5b28dfe28abb572.webp\" alt=\"LINK-PP Solutions\" class=\"wp-image-5278\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d9cc5ec3f48c48f3b5b28dfe28abb572.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d9cc5ec3f48c48f3b5b28dfe28abb572-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d9cc5ec3f48c48f3b5b28dfe28abb572-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d9cc5ec3f48c48f3b5b28dfe28abb572-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d9cc5ec3f48c48f3b5b28dfe28abb572-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Si dise\u00f1a u opera enlaces en el rango de 1 G a 800 G, LINK-PP ofrece m\u00f3dulos y soluciones de conectividad dise\u00f1ados para compatibilidad, rendimiento y una cualificaci\u00f3n fluida:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Transceptores \u00f3pticos: familias SFP\/SFP+, SFP28, QSFP28, QSFP-DD y OSFP alineadas con las \u00f3pticas Ethernet IEEE. Consulte nuestra descripci\u00f3n general sobre por qu\u00e9 las empresas eligen nuestros m\u00f3dulos en <a target=\"_blank\" rel=\"nofollow\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/why-choose-link-pp-fiber-optical-modules\/\">\u00bfPor qu\u00e9 elegir los m\u00f3dulos \u00f3pticos de fibra LINK-PP?<\/a>.<\/p><\/li><li><p>Conectores y ensamblajes: conectividad d\u00faplex LC y compatible con MPO\/MTP, con opciones de baja p\u00e9rdida para proteger su presupuesto. Para informaci\u00f3n b\u00e1sica sobre conectores, consulte <a target=\"_blank\" rel=\"nofollow\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/common-fiber-connector-types-optical-transceivers\/\">Tipos comunes de conectores de fibra en transceptores \u00f3pticos<\/a>.<\/p><\/li><li><p>Evaluaci\u00f3n simplificada: Solicite muestras gratuitas y obtenga soporte t\u00e9cnico para validar las p\u00e9rdidas por inserci\u00f3n (IL) y los presupuestos de enlace en su entorno; consulte las llamadas a la acci\u00f3n (CTA) de muestra\/soporte en nuestras p\u00e1ginas de tienda, como la <a target=\"_blank\" rel=\"nofollow\" href=\"https:\/\/www.l-p.com\/store-26155-1g-sfp.htm\">p\u00e1gina del cat\u00e1logo LINK-PP de SFP 1G<\/a>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Preguntas frecuentes r\u00e1pidas<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>P1: \u00bfCu\u00e1l es un valor aceptable de p\u00e9rdida por inserci\u00f3n por conector?<\/strong><br\/>R: Para conectores de alta calidad, &lt;0,3 dB es t\u00edpico.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>P2: \u00bfCon qu\u00e9 frecuencia debe probarse la IL?<\/strong><br\/>R: En la instalaci\u00f3n y tras cualquier mantenimiento importante. En enlaces cr\u00edticos puede realizarse una nueva prueba durante auditor\u00edas programadas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>P3: \u00bfSe puede reducir la p\u00e9rdida por inserci\u00f3n tras la instalaci\u00f3n?<\/strong><br\/>R: A menudo s\u00ed: limpiar los conectores o volver a terminar empalmes con altas p\u00e9rdidas puede disminuir la IL.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u25b6 Conclusi\u00f3n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La p\u00e9rdida por inserci\u00f3n puede parecer una cifra peque\u00f1a, pero en redes \u00f3pticas de alta velocidad cada fracci\u00f3n de decibelio cuenta. Un dise\u00f1o, pruebas y mantenimiento adecuados son esenciales para garantizar un rendimiento fiable.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para los ingenieros que implementan <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>Transceptores \u00f3pticos de LINK-PP<\/strong><\/a>, comprobar la p\u00e9rdida por inserci\u00f3n es un paso cr\u00edtico para validar el rendimiento en condiciones reales. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Al comprender la p\u00e9rdida por inserci\u00f3n, probarla correctamente y minimizarla en la pr\u00e1ctica, los operadores de red pueden construir enlaces fiables, de alto rendimiento y preparados para el futuro.<\/p>","protected":false},"excerpt":{"rendered":"<p>Aprenda qu\u00e9 es la p\u00e9rdida por inserci\u00f3n en los transceptores \u00f3pticos, c\u00f3mo afecta los presupuestos de enlace, la tasa de errores de bits (BER) y la correcci\u00f3n de errores hacia adelante (FEC). Incluye valores LC\/MPO, consejos de control e informaci\u00f3n especializada de LINK-PP.<\/p>","protected":false},"author":1,"featured_media":5279,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[19,21,26],"class_list":["post-5280","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-aoc-dac-cables","tag-fiber-optic-cage-and-connector","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/5280","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/comments?post=5280"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/5280\/revisions"}],"predecessor-version":[{"id":11203,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/5280\/revisions\/11203"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/media\/5279"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/media?parent=5280"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/categories?post=5280"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/tags?post=5280"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}