{"id":4545,"date":"2025-10-31T11:12:00","date_gmt":"2025-10-31T11:12:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/25gbase-ieee-802-3by-single-lane-25gbe-standard\/"},"modified":"2026-06-22T05:43:36","modified_gmt":"2026-06-22T05:43:36","slug":"25gbase-ieee-802-3by-single-lane-25gbe-standard","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/25gbase-ieee-802-3by-single-lane-25gbe-standard","title":{"rendered":"25GBASE IEEE 802.3by: El est\u00e1ndar Ethernet de 25 Gb de una sola v\u00eda"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ca1377e01de94208976debf546751df0.webp\" alt=\"What Is IEEE 802.3by?\" class=\"wp-image-4542\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ca1377e01de94208976debf546751df0.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ca1377e01de94208976debf546751df0-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ca1377e01de94208976debf546751df0-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ca1377e01de94208976debf546751df0-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ca1377e01de94208976debf546751df0-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">La explosi\u00f3n de los servicios en la nube, la virtualizaci\u00f3n, las cargas de trabajo de IA y los despliegues de servidores de alta densidad ha impulsado a los centros de datos a buscar tecnolog\u00edas Ethernet m\u00e1s r\u00e1pidas y eficientes. Para cubrir la brecha entre 10 GbE y las costosas tecnolog\u00edas de 40\/100 GbE, el IEEE introdujo <strong>\u2605 Ventajas y Escenarios de Uso<\/strong>, que define una <strong>capa f\u00edsica Ethernet de 25 Gb\/s por canal \u00fanico<\/strong>, com\u00fanmente conocido como <strong>25GBASE<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Este art\u00edculo explica qu\u00e9 es el est\u00e1ndar IEEE 802.3by, por qu\u00e9 es relevante y c\u00f3mo posibilita un despliegue escalable de Ethernet a 25 Gb\/s \u2014 junto con c\u00f3mo los <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26225-25g-sfp28.htm\">m\u00f3dulos SFP28 de LINK-PP<\/a> respaldan este ecosistema.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udd39 \u00bfQu\u00e9 es el IEEE 802.3by?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">El IEEE 802.3by es una enmienda al est\u00e1ndar Ethernet IEEE 802.3 que define las especificaciones para <strong>Ethernet de 25 gigabits sobre un \u00fanico canal el\u00e9ctrico<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Estandariza la transmisi\u00f3n a 25 Gb\/s en:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>cables de cobre directo (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/what-is-breakout-dac-and-why-breakout-dac-matters\/\">SFP significa:<\/a>)<\/p><\/li><li><p>canales de backplane<\/p><\/li><li><p>Fibra multimodo<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">El objetivo: ofrecer una ruta de actualizaci\u00f3n sencilla, rentable y de alta densidad desde 10G hasta 25G, especialmente en conexiones servidor-centro de datos a switch de hoja.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udd39 Por qu\u00e9 se cre\u00f3 el 25GBASE<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Eficiencia del canal \u00fanico<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Los enlaces anteriores de 40GbE utilizaban <strong>4 canales de 10 Gb\/s<\/strong>. En cambio, el 25GBASE emplea <strong>1 canal de 25 Gb\/s<\/strong>, lo que ofrece:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Mayor ancho de banda por canal<\/p><\/li><li><p>Menor consumo de energ\u00eda<\/p><\/li><li><p>Reducci\u00f3n del costo por puerto<\/p><\/li><li><p>Cableado y \u00f3ptica m\u00e1s sencillos<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Paso ideal desde 10G<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Los 25 Gb\/s proporcionan <strong>2,5 veces el ancho de banda de 10 Gb\/s<\/strong> con solo un ligero aumento de consumo energ\u00e9tico y costo \u2014ideal para E\/S de servidores de alta densidad.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Ruta escalable hacia 50\/100 GbE<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">El 25G constituye el bloque fundamental para:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Ethernet de 50G (2 canales de 25G)<\/p><\/li><li><p>Ethernet de 100 G (<a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472118.htm\">4 canales de 25G<\/a>)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Es una velocidad fundamental en las redes modernas de centros de datos.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udd39 Caracter\u00edsticas t\u00e9cnicas clave del 25GBASE (IEEE 802.3by)<\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 303px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"303\"><p>Caracter\u00edstica<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Descripci\u00f3n<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"303\"><p>Velocidad de l\u00ednea<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>25 Gb\/s por canal<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"303\"><p>Codificaci\u00f3n<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>codificaci\u00f3n de l\u00ednea 64b\/66b<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"303\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/fec-forward-error-correction-in-optical-communication\/\">FEC<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>FEC-RS opcional<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"303\"><p>: Hasta ~100 m (dependiendo del tipo de fibra) sobre MMF mediante d\u00faplex LC\/UPC.<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Cobre, backplane, fibra multimodo<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"303\"><p>Formato del m\u00f3dulo<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SFP28<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"303\"><p>Uso previsto<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Interconexiones entre servidores y conmutadores<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udd39 Variantes de interfaz 25GBASE<\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>IEEE 802.3z (1000BASE-SX)<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Medio<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Caso de uso<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>25GBASE-CR \/ CR-S<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>DAC de cobre Twinax<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Interconexiones de corto alcance (1\u20135 m) dentro del rack<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>25GBASE-KR \/ KR-S<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Placa base<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Enlaces de backplane para servidores o tarjetas de l\u00ednea<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476099.htm\">est\u00e1ndar 25GBASE-SR<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibra multimodo<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Hasta ~100 m sobre fibra OM4<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476046.htm\">25GBASE-LR<\/a>*<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Direct Attach Copper (DAC)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~10 km (*definido en enmiendas posteriores)<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udd39 Escenarios t\u00edpicos de despliegue<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Redes hoja-espalda (leaf-spine) en centros de datos<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">El 25GBASE ayuda a los operadores a escalar el tr\u00e1fico este-oeste mientras controlan el costo y la huella de infraestructura.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Conexiones servidor-a-switch superior del rack (ToR)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Servidores con NIC de 25G se conectan a switches ToR mediante \u00f3pticas SFP28 o cables DAC.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Agregaci\u00f3n y <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/what-you-need-to-know-about-edge-computing-key-benefits-uses\/\">Computaci\u00f3n de borde<\/a><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Los enlaces ascendentes compatibles con 25G ofrecen el equilibrio adecuado entre rendimiento y costo, especialmente en arquitecturas perimetrales y preparadas para IA.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udd39 Buenas pr\u00e1cticas para desplegar 25GBASE<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Elegir el soporte f\u00edsico adecuado<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>1\u20135 m:<\/strong> Cobre DAC (25GBASE-CR)<\/p><\/li><li><p><strong>Hasta ~100 m:<\/strong> Fibra multimodo (25GBASE-SR + OM4)<\/p><\/li><li><p><strong>Campus\/alcanzando larga distancia:<\/strong> Fibra monomodo (25GBASE-LR u otras especificaciones posteriores)<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Validar la interoperabilidad del hardware<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Asegurarse de que switches, NIC y <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26225-25g-sfp28.htm\">m\u00f3dulos \u00f3pticos<br><\/a> cumplan todos con el IEEE 802.3by.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Considerar los requisitos de FEC<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Activar FEC-RS donde el margen del enlace o los entornos de EMC exijan mayor robustez.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udd39 M\u00f3dulos SFP28 y soluciones LINK-PP<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/dbd37648365f4364bc8c6a1ec2ef4a77.webp\" alt=\"LINK-PP SFP28 Modules\" class=\"wp-image-4543\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/dbd37648365f4364bc8c6a1ec2ef4a77.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/dbd37648365f4364bc8c6a1ec2ef4a77-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/dbd37648365f4364bc8c6a1ec2ef4a77-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/dbd37648365f4364bc8c6a1ec2ef4a77-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/dbd37648365f4364bc8c6a1ec2ef4a77-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">El factor de forma principal para 25GBASE es <strong>SFP28<\/strong> \u2014mec\u00e1nicamente similar al SFP+, pero con especificaciones el\u00e9ctricas mejoradas para se\u00f1ales de 25 Gb\/s.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">LINK-PP ofrece <strong>M\u00f3dulos \u00f3pticos SFP28 y cables DAC de 25G alineados con el IEEE 802.3by<\/strong> para despliegues de alta densidad en centros de datos:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udd17<a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26225-25g-sfp28.htm\"><strong>Transceptores SFP28 de 25G de LINK-PP<\/strong><\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Beneficios clave de los m\u00f3dulos de 25G de LINK-PP:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Rendimiento de enlace de baja latencia y alta estabilidad<\/p><\/li><li><p>Compatibilidad de nivel OEM con las principales marcas de switches<\/p><\/li><li><p>Fiabilidad comprobada en centros de datos hipercalados y empresariales<\/p><\/li><li><p>Precios competitivos para despliegues a gran volumen<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udd39 Resumen<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">El est\u00e1ndar IEEE 802.3by posibilita <strong>un despliegue eficiente y escalable de 25 GbE por canal \u00fanico<\/strong> \u2014ahora una tecnolog\u00eda central en los centros de datos modernos. Con cableado sencillo, fuerte compatibilidad hacia atr\u00e1s con 10G y escalabilidad hacia adelante a 50\/100G y 25GBASE, el 25GBASE es un escal\u00f3n esencial en la evoluci\u00f3n de redes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para ingenieros y planificadores que migran a 25 Gb\/s, <strong>LINK-PP <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476046.htm\"><strong>M\u00f3dulos SFP28<\/strong><\/a><strong> and <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26454-dac-aoc-aec-cables.htm\"><strong>las soluciones DAC<\/strong><\/a> ofrecen conectividad fiable y optimizada en costos, alineada con las especificaciones IEEE 802.3by.<\/p>","protected":false},"excerpt":{"rendered":"<p>Explore el est\u00e1ndar IEEE 802.3by para Ethernet 25GBASE. Conozca sus especificaciones, tipos de medios, escenarios de aplicaci\u00f3n y c\u00f3mo los m\u00f3dulos SFP28 LINK-PP admiten redes 25GbE fiables.<\/p>","protected":false},"author":1,"featured_media":4544,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[16,26],"class_list":["post-4545","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-link-pp-25g-sfp28-optical-modules","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/4545","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/comments?post=4545"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/4545\/revisions"}],"predecessor-version":[{"id":10951,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/4545\/revisions\/10951"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/media\/4544"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/media?parent=4545"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/categories?post=4545"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/tags?post=4545"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}