{"id":3965,"date":"2025-09-05T00:00:00","date_gmt":"2025-09-05T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/glossary\/otu4-backbone-high-speed-optical-transport-networks\/"},"modified":"2026-06-22T07:40:25","modified_gmt":"2026-06-22T07:40:25","slug":"otu4-backbone-high-speed-optical-transport-networks","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/otu4-backbone-high-speed-optical-transport-networks","title":{"rendered":"OTU4 explicado: La columna vertebral del transporte \u00f3ptico de alta velocidad"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5c37cc52bd2c4003be5c5f52c5d94a34.webp\" alt=\"OTU4 Explained The Backbone of High-Speed Optical Transport\" class=\"wp-image-3963\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5c37cc52bd2c4003be5c5f52c5d94a34.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5c37cc52bd2c4003be5c5f52c5d94a34-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5c37cc52bd2c4003be5c5f52c5d94a34-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5c37cc52bd2c4003be5c5f52c5d94a34-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5c37cc52bd2c4003be5c5f52c5d94a34-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">El mundo digital funciona con datos. Desde la transmisi\u00f3n de video en 4K hasta el impulso de la computaci\u00f3n en la nube, la demanda de ancho de banda est\u00e1 explotando. Detr\u00e1s de escena, un sistema complejo y estandarizado trabaja incansablemente para trasladar estos datos de forma fiable a trav\u00e9s de grandes distancias. En el coraz\u00f3n de las redes modernas de alta velocidad se encuentra un protocolo fundamental: <strong>OTU4<\/strong>. , si usted participa en <strong>infraestructura de red<\/strong>, <strong>centros de datos<\/strong>, or <strong>telecomunicaciones<\/strong>, comprender el OTU4 es esencial.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Esta gu\u00eda explicar\u00e1 qu\u00e9 es el OTU4, por qu\u00e9 constituye un pilar fundamental del <strong>transporte de 100 G<\/strong>, y c\u00f3mo mantiene conectada nuestra econom\u00eda digital global.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd \u00bfQu\u00e9 es exactamente el OTU4?<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">OTU4 significa <strong>Unidad de Transporte \u00d3ptico 4<\/strong>. Es un encapsulamiento digital estandarizado definido por la <strong>UIT-T (Uni\u00f3n Internacional de Telecomunicaciones)<\/strong> en la recomendaci\u00f3n <strong>G.709<\/strong> , conocida com\u00fanmente como \u201c<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/what-is-otn-optical-transport-network\/\"><strong>OTN<\/strong><\/a>\u201d.<strong>Optical Transport Network<\/strong>).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Piense en ello como un contenedor de env\u00edo altamente seguro y eficiente para los datos. Los datos cliente sin procesar (como Ethernet, Canal de Fibra o MPLS) se colocan dentro de un \u201ccontenedor\u201d OTU4. Este contenedor:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Proporciona una estructura de trama estandarizada<\/strong> para transportar 100 gigabits por segundo (Gbps) de datos.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>A\u00f1ade bytes de sobrecarga<\/strong> para funciones cr\u00edticas como supervisi\u00f3n del rendimiento, detecci\u00f3n de errores y canales de gesti\u00f3n.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Garantiza una correcci\u00f3n robusta de errores hacia adelante <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/fec-forward-error-correction-in-optical-communication\/\"><strong>(FEC)<\/strong><\/a>, lo cual es crucial para mantener la integridad de la se\u00f1al y extender el alcance en redes de largo recorrido <strong>DWDM.<\/strong>.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">En t\u00e9rminos sencillos, <strong>OTU4 es el protocolo que define c\u00f3mo se formatean, gestionan y transportan las se\u00f1ales de 100 G a trav\u00e9s de redes \u00f3pticas.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd \u00bfPor qu\u00e9 importa el OTU4?: Beneficios clave y su funci\u00f3n<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>OTU4<\/strong> no es simplemente otro protocolo; represent\u00f3 un avance significativo. Estas son las razones por las que importa:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Estandarizaci\u00f3n:<\/strong> Cre\u00f3 un est\u00e1ndar universal e interoperable para el <strong>transporte \u00f3ptico de 100 G<\/strong>, permitiendo que equipos de distintos fabricantes funcionen juntos sin problemas.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Rendimiento superior:<\/strong> La potente <strong>FEC<\/strong> incorporada al OTU4 permite mayores distancias de transmisi\u00f3n y un mejor rendimiento en entornos ruidosos comparado con est\u00e1ndares anteriores.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Supervisi\u00f3n mejorada:<\/strong> Su amplia sobrecarga proporciona a los operadores de red una visibilidad detallada y en tiempo real del estado y el rendimiento de cada longitud de onda, simplificando<br> <strong>la gesti\u00f3n de la red<br><\/strong> y la resoluci\u00f3n de problemas.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Eficiencia de multiplexaci\u00f3n:<br><\/strong> OTU4 es un bloque fundamental en<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/what-is-dwdm-explaining-dense-wavelength-division-multiplexing\/\"><strong>Transceptores DWDM (Multiplexaci\u00f3n densa por divisi\u00f3n de longitudes de onda)<\/strong><\/a> sistemas, lo que permite combinar m\u00faltiples canales de 100 G en una sola fibra.<br>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd OTU4 frente a otros est\u00e1ndares OTN: una comparaci\u00f3n r\u00e1pida<br><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>OTN<\/strong> La jerarqu\u00eda incluye varios niveles dise\u00f1ados para distintas velocidades de l\u00ednea. A continuaci\u00f3n se muestra c\u00f3mo se compara OTU4 con sus predecesores.<br>.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Nivel OTU<br><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Velocidad de l\u00ednea (aprox.)<br><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Se\u00f1al cliente habitual<br><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Caso de uso principal<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>OTU1<br><\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>2,67 Gbps<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SDH\/SONET STM-16\/OC-48<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Transporte heredado de 2,5 G<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>OTU2<br><\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10,71 Gbps<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Ethernet de 10 Gigabit<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Transporte de 10 G<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>OTU2e<br><\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>11,10 Gbps<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Ethernet 10GBASE-R<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Transporte LAN PHY<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>OTU3<br><\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>43,02 Gbps<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Ethernet de 40 Gigabits<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Transporte de 40 G<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>OTU4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>111,81 Gbps<br><\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Ethernet de 100 gigabits<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Transporte de 100 G<br><\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>OTUCn<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>n \u00d7 105,25 Gbps<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Ethernet de 200 G, 400 G y 800 G<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Transporte flexible de alta velocidad<br><\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd \u00bfD\u00f3nde se utiliza OTU4? Aplicaciones reales<br><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Encontrar\u00e1 la tecnolog\u00eda OTU4 habilitando infraestructuras cr\u00edticas en:<br><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Interconexiones de Centro de Datos <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/data-center-interconnect-definition-benefits-and-role-of-optical-modules\/\"><strong>(DCI)<\/strong><\/a><strong>:<\/strong> Conexi\u00f3n de centros de datos geogr\u00e1ficamente dispersos mediante enlaces de alta capacidad y confiabilidad<br> <strong>de 100 G<br><\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>N\u00facleo de telecomunicaciones y<br> <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/metro-ethernet-improve-network-connectivity-business-benefits\/\"><strong>Redes metropolitanas<\/strong><\/a><strong>:<\/strong> Formaci\u00f3n del esqueleto de las redes de los proveedores de servicios, gestionando tr\u00e1fico agregado masivo.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Redes de proveedores de servicios en la nube:<br><\/strong> Impulso de la infraestructura detr\u00e1s de los principales servicios en la nube y redes de distribuci\u00f3n de contenidos (CDN).<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Redes financieras:<br><\/strong> Donde la baja latencia y la fiabilidad extrema son requisitos ineludibles para las operaciones de alta frecuencia.<br>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd C\u00f3mo hacer funcionar OTU4: el papel fundamental de los transceptores \u00f3pticos<br><\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/481123d61fe74e21bd974711f145ccfa.webp\" alt=\"optical transceiver\" class=\"wp-image-3964\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/481123d61fe74e21bd974711f145ccfa.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/481123d61fe74e21bd974711f145ccfa-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/481123d61fe74e21bd974711f145ccfa-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/481123d61fe74e21bd974711f145ccfa-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/481123d61fe74e21bd974711f145ccfa-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">An <strong>OTU4<\/strong> La se\u00f1al no viaja por s\u00ed sola; requiere hardware para generarla, transmitirla y recibirla. Aqu\u00ed es donde entran en juego los<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>transceptores \u00f3pticos<\/strong><\/a> transceptores \u00f3pticos. Estos m\u00f3dulos extra\u00edbles son los motores que convierten la se\u00f1al el\u00e9ctrica OTU4 en un pulso \u00f3ptico para su transmisi\u00f3n por fibra.<br>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para una implementaci\u00f3n robusta de una red<br> <strong>OTU4<br><\/strong>, elegir transceptores de alta calidad y confiabilidad es fundamental. Aqu\u00ed es donde un socio de confianza como<br> <strong>LINK-PP<\/strong> marca toda la diferencia.<br>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>LINK-PP<\/strong><\/a> ofrece transceptores de alto rendimiento y compatibles para<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>transceptores \u00f3pticos de 100G<\/strong><\/a> dise\u00f1adas para <strong>aplicaciones OTU4<br><\/strong>. Un ejemplo perfecto es el m\u00f3dulo<br> <strong>QSFP28-100G-ZR4-S<br><\/strong> Este transceptor est\u00e1 dise\u00f1ado espec\u00edficamente para soportar el est\u00e1ndar OTU4 y ofrece:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\">Cumplimiento total de los requisitos ITU-T G.709 OTU4.<\/p><\/li><li><p style=\"margin: 0px;\">Soporte para transmisi\u00f3n de larga distancia hasta 80 km en fibra monomodo.<\/p><\/li><li><p style=\"margin: 0px;\">Tecnolog\u00eda DWDM integrada para su uso en <strong>optimizaci\u00f3n de capacidad<\/strong> escenarios.<\/p><\/li><li><p style=\"margin: 0px;\">Alta fiabilidad y estabilidad, lo que garantiza un tiempo de inactividad m\u00ednimo de la red.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Cuando est\u00e1 dise\u00f1ando o actualizando una <strong>infraestructura de red de 100 G<\/strong>, seleccionar el <strong>transceptor 100G ZR4 adecuado<\/strong> es una decisi\u00f3n cr\u00edtica para el rendimiento y la <strong>rentabilidad<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Conclusi\u00f3n: OTU4 \u2014 La base probada para 100G<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>OTU4<\/strong> se ha consolidado firmemente como la base de la <strong>transmisi\u00f3n \u00f3ptica de 100 gigabits<\/strong>. Su dise\u00f1o robusto, que incluye s\u00f3lidas <strong>FEC<\/strong> y completas capacidades de gesti\u00f3n, ofrece la fiabilidad y eficiencia que exigen los operadores de redes. A medida que avanzamos hacia una era de 400G y 800G, los principios y la infraestructura basados en OTU4 siguen proporcionando una base fundamental.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u00bfListo para construir u optimizar su red OTN de 100G?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Aseg\u00farese de que su infraestructura est\u00e9 equipada con componentes fiables y de alto rendimiento. Explore <strong>LINK-PP<\/strong>\u2018la amplia gama de <strong>transceptores \u00f3pticos compatibles con OTU4 de LINK-PP<\/strong>, incluidas nuestras <strong>QSFP28-100G-ZR4-S<br><\/strong> y otros <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/coherent-transceivers-high-speed-data-transmission-explained\/\"><strong>\u00f3ptica coherente<\/strong><\/a> soluciones, dise\u00f1adas para ofrecer un rendimiento y valor incomparables.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u27a1\ufe0f <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.link-pp.com\/\"><strong>Visite el sitio web de LINK-PP<\/strong><\/a><strong> \u00a1hoy mismo para encontrar el transceptor \u00f3ptico perfecto para su aplicaci\u00f3n y obtener un presupuesto!<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Preguntas frecuentes<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfQu\u00e9 significa OTU4?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">OTU4 significa Unidad de Transporte \u00d3ptico 4. Se utiliza para trasladar datos a gran velocidad en redes \u00f3pticas. Cumple con la norma ITU-T G.709.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfC\u00f3mo protege OTU4 sus datos?<\/h3>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>OTU4 utiliza <a target=\"_blank\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/fec-forward-error-correction-in-optical-communication\/\"><strong>Correcci\u00f3n de errores por adelantado (FEC)<\/strong><\/a>. La correcci\u00f3n de errores hacia adelante (FEC) agrega bits adicionales a sus datos. As\u00ed obtiene menos errores y una transmisi\u00f3n m\u00e1s segura, incluso a largas distancias.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfPuede utilizar OTU4 para servicios en la nube?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00ed, puede hacerlo. OTU4 ayuda a los proveedores de servicios en la nube a trasladar grandes vol\u00famenes de datos r\u00e1pidamente. Obtiene conexiones fiables entre centros de datos y plataformas en la nube.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfCu\u00e1l es la se\u00f1al cliente principal para OTU4?<\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>OTU4<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Se\u00f1al cliente principal<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>OTU4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>100GE (Ethernet de 100 gigabits)<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Principalmente se utiliza OTU4 para transportar se\u00f1ales 100GE a trav\u00e9s de redes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfPor qu\u00e9 deber\u00eda elegir OTU4 para su empresa?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Obtiene alta velocidad.<\/p><\/li><li><p>Disfruta de una solidez fiable.<\/p><\/li><li><p>Puede ampliar su red f\u00e1cilmente.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">OTU4 respalda las necesidades empresariales de transporte de datos r\u00e1pido, seguro y escalable.<\/p>","protected":false},"excerpt":{"rendered":"<p>OTU4 es una capa digital de alta velocidad en redes de transporte \u00f3ptico, que permite la transmisi\u00f3n fiable de datos a 100GE con una fuerte correcci\u00f3n de errores y escalabilidad.<\/p>","protected":false},"author":1,"featured_media":3963,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[27],"tags":[26],"class_list":["post-3965","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-glossary","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/3965","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/comments?post=3965"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/3965\/revisions"}],"predecessor-version":[{"id":11172,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/3965\/revisions\/11172"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/media\/3963"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/media?parent=3965"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/categories?post=3965"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/tags?post=3965"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}