{"id":3818,"date":"2025-09-03T00:00:00","date_gmt":"2025-09-03T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/glossary\/mode-conditioning-patch-cables-how-they-work-in-networks\/"},"modified":"2026-06-22T07:47:30","modified_gmt":"2026-06-22T07:47:30","slug":"mode-conditioning-patch-cables-how-they-work-in-networks","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/mode-conditioning-patch-cables-how-they-work-in-networks","title":{"rendered":"\u00bfQu\u00e9 son los cables de conexi\u00f3n por acondicionamiento de modo y c\u00f3mo funcionan?"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f.webp\" alt=\"What Are Mode Conditioning Patch Cables\" class=\"wp-image-3815\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u00bfAlguna vez ha implementado un transceptor \u00f3ptico Gigabit LX o 10G LR y ha sufrido errores inesperados, alta atenuaci\u00f3n o enlaces inestables? El culpable podr\u00eda no ser su equipo, sino una incompatibilidad fundamental entre los tipos de cable de fibra \u00f3ptica. Aqu\u00ed es donde entra en juego un peque\u00f1o pero poderoso h\u00e9roe: el <strong>Cable de conexi\u00f3n por acondicionamiento de modo (MCP)<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En esta gu\u00eda, desmitificaremos <strong>qu\u00e9 es un cable de conexi\u00f3n por acondicionamiento de modo<\/strong>, por qu\u00e9 es esencial en escenarios de red espec\u00edficos y c\u00f3mo puede salvarlo de una infinidad de dolores de cabeza relacionados con la conectividad. Tambi\u00e9n exploraremos c\u00f3mo interact\u00faa con componentes de alto rendimiento como <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>Transceptores \u00f3pticos de LINK-PP<\/strong><\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Conclusiones clave<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Cables de conexi\u00f3n por acondicionamiento de modo<\/strong> ayudan a que los dispositivos de modo \u00fanico utilicen fibra multimodo. Corrigen problemas de se\u00f1al como el retardo diferencial de modo.<\/p><\/li><li><p>Estos cables mejoran la se\u00f1al y reducen los errores. Esto permite que las redes funcionen m\u00e1s r\u00e1pido y de forma m\u00e1s fiable, especialmente para Ethernet Gigabit.<\/p><\/li><li><p>Los cables tienen una parte especial con una secci\u00f3n de modo \u00fanico. Esta parte desplaza la se\u00f1al luminosa para reducir la distorsi\u00f3n y mejorar la transmisi\u00f3n de datos.<\/p><\/li><li><p>Conecte siempre el extremo de modo \u00fanico al transceptor. Conecte el extremo multimodo a la planta de fibra para evitar problemas de red.<\/p><\/li><li><p>Limpie los conectores antes de usarlos. No doble los cables bruscamente. Pruebe la conexi\u00f3n tras su instalaci\u00f3n para mantener la red robusta.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 \u00bfPor qu\u00e9 necesitamos un \u201ccable especial\u201d? El problema multimodo frente a modo \u00fanico<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Para comprender la soluci\u00f3n, primero debemos entender el problema. Los cables de fibra \u00f3ptica existen principalmente en dos tipos:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/om1-om2-om3-om4-om5-multimode-fiber-guide\/\"><strong>Fibra multimodo (MMF)<\/strong><\/a><strong>:<\/strong> Tiene un n\u00facleo m\u00e1s grande, lo que permite que viajen m\u00faltiples modos de luz (trayectorias). Est\u00e1 dise\u00f1ado para aplicaciones de corta distancia y alto ancho de banda dentro de edificios o campus. Los tipos comunes son <strong>OM1, OM2, OM3 y OM4<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/what-is-single-mode-fiber-and-how-does-it-work\/\"><strong>Fibra monomodo (SMF)<\/strong><\/a><strong>:<\/strong> Tiene un n\u00facleo mucho m\u00e1s peque\u00f1o, lo que permite que viaje un solo modo de luz en l\u00ednea recta. Est\u00e1 dise\u00f1ado para comunicaciones de larga distancia, como entre ciudades.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">El problema surge cuando intenta conectar un <strong>Transceptor de alcance largo (LX\/LR)<\/strong> (dise\u00f1ado para fibra monomodo, SMF) a una <strong>Fibra multimodo (MMF)<\/strong> planta de cableado multimodo (MMF). Esto es com\u00fan en edificios antiguos cableados con MMF que deben conectarse a un nuevo entronque de SMF.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La luz l\u00e1ser del transceptor LX\/LR se inyecta en el n\u00facleo grande de la MMF. Esto puede provocar un fen\u00f3meno denominado <strong>Retardo diferencial de modo (DMD)<\/strong>, en el que los pulsos de luz se dispersan y se distorsionan durante su recorrido, causando jitter, errores y fallo total del enlace. Esto es especialmente problem\u00e1tico con <strong>fibra OM3 y OM4<\/strong> and <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475586.htm\"><strong>m\u00f3dulos 10G LR<\/strong><\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 \u00bfC\u00f3mo funciona un cable de conexi\u00f3n por acondicionamiento de modo?<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"318\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028.webp\" alt=\"Mode Conditioning Patch Cables\" class=\"wp-image-3816\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028-300x80.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028-1024x271.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028-768x204.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028-18x5.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">A <strong>Cable de conexi\u00f3n de acondicionamiento de modo<\/strong> es un <strong>cable de salto d\u00faplex de fibra<\/strong> ingeniosamente dise\u00f1ado que resuelve esta incompatibilidad en la capa f\u00edsica. A veces tambi\u00e9n se denomina <em>cable de salto por acondicionamiento de modo<\/em>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Su magia radica en su construcci\u00f3n en el lado de transmisi\u00f3n (Tx):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\">Una de las fibras del cable es un conector est\u00e1ndar de <strong>modo \u00fanico<\/strong> que se conecta a su transceptor.<\/p><\/li><li><p style=\"margin: 0px;\">La otra fibra es un <strong>conector multimodo<\/strong> con una fusi\u00f3n descentrada precisa a varios metros del extremo.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Este dise\u00f1o obliga a que la luz l\u00e1ser recorra primero una corta distancia sobre fibra monomodo. Luego se inyecta estrat\u00e9gicamente en el <strong>centro del n\u00facleo de la fibra multimodo<\/strong> en el punto de fusi\u00f3n. Cuando la se\u00f1al entra en su planta de cableado MMF heredada, ya se ha estabilizado, eliminando efectivamente el efecto DMD y permitiendo una transmisi\u00f3n de datos limpia y fiable.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Aplicaciones clave y casos de uso:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\">Conectar<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476763.htm\"><strong>M\u00f3dulo SFP 1000BASE-LX<\/strong><\/a> to <strong>Fibra multimodo OM1\/OM2\/OM3<\/strong> .<\/p><\/li><li><p style=\"margin: 0px;\">Conectar<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475586.htm\"><strong>M\u00f3dulos SFP+ 10GBASE-LR<\/strong><\/a> to <strong>OM3\/OM4<\/strong> .<\/p><\/li><li><p style=\"margin: 0px;\">Extensi\u00f3n del alcance de los transceptores LX\/LR sobre MMF m\u00e1s all\u00e1 de la distancia t\u00edpica limitada por DMD.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Acondicionamiento de modo frente a cable de conexi\u00f3n est\u00e1ndar: comparaci\u00f3n r\u00e1pida<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Caracter\u00edstica<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Cable de conexi\u00f3n est\u00e1ndar<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Cable de conexi\u00f3n de acondicionamiento de modo<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Funci\u00f3n principal<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Conecta tipos de fibra iguales (SMF-SMF o MMF-MMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Conecta tipos de fibra distintos (transceptor SMF a cable MMF)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Dise\u00f1o interno<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Tipo de fibra constante en toda su longitud<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Incorpora una <strong>fusi\u00f3n descentrada precisa<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Caso de uso<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Conexiones est\u00e1ndar, tipo \u00abin\u00bb<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Actualizaciones de redes heredadas<\/strong>, requisitos espec\u00edficos de transceptores<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u00bfEvita el DMD?<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>No<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Yes<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Cost<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lower<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Ligeramente superior<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Integraci\u00f3n con los transceptores \u00f3pticos LINK-PP para un rendimiento \u00f3ptimo<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"719\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f.jpg\" alt=\"optical transceivers\" class=\"wp-image-3817\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f-300x180.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f-1024x614.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f-768x460.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f-18x12.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Al construir una red fiable y de alto rendimiento, cada componente debe funcionar en armon\u00eda. Usar un cable de acondicionamiento de modo de calidad es crucial para aprovechar todo el potencial de sus <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>transceptores de fibra \u00f3ptica<\/strong><\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Por ejemplo, si est\u00e1 utilizando un <strong>LINK-PP <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475586.htm\"><strong>SFP-10G-LR<\/strong><\/a> m\u00f3dulo para conectarse a un entronque multimodo OM3 existente, un cable de conexi\u00f3n por acondicionamiento de modo no es simplemente recomendable; con frecuencia es obligatorio para garantizar un enlace estable. Lo mismo aplica para un<strong> <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476763.htm\"><strong>SFP-1G-LX<\/strong><\/a> m\u00f3dulo sobre cable OM1 antiguo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Consejo profesional:<\/strong> Consulte siempre la hoja de datos de sus <strong>transceptores compatibles con LINK-PP<\/strong>. All\u00ed se especificar\u00e1 el tipo de fibra requerido y, con frecuencia, se mencionar\u00e1 expl\u00edcitamente la necesidad de un cable de conexi\u00f3n por acondicionamiento de modo al conectarlo a MMF. Implementar correctamente esta configuraci\u00f3n es una pr\u00e1ctica recomendada para <strong>fiabilidad de la red<\/strong> y para minimizar <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/understanding-what-is-bit-error-rate\/\"><strong>tasas de error de bit (BER)<\/strong><\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 \u00bfNecesita uno? Conclusiones clave<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Necesita un cable de conexi\u00f3n por acondicionamiento de modo si:<\/strong> Est\u00e1 conectando un transceptor <strong>de alcance largo (LX, LR, ER)<\/strong> SFP, SFP+ o GBIC a una <strong>Fibra multimodo (MMF)<\/strong> instalaci\u00f3n de cable multimodo.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>NO necesita uno si:<\/strong> Est\u00e1 conectando un transceptor al mismo tipo de fibra para el que fue dise\u00f1ado (por ejemplo, LX a SMF, o SX a MMF).<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Invertir en la infraestructura de cableado adecuada garantiza que su red funcione eficientemente, reduce el tiempo de inactividad y protege su inversi\u00f3n en hardware de calidad como <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>M\u00f3dulos \u00f3pticos LINK-PP<\/strong><\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Preguntas frecuentes<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfCu\u00e1l es el prop\u00f3sito principal de un cable de acondicionamiento de modo?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un cable de acondicionamiento de modo permite que los transceptores de fibra monomodo funcionen con fibra multimodo. Ayuda a reducir problemas de se\u00f1al como el retardo diferencial de modo. Esto mantiene los datos fluyendo sin interrupciones en redes de fibra mixta.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfSe puede usar un cable de acondicionamiento de modo con cualquier sistema de fibra \u00f3ptica?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No, estos cables funcionan mejor al conectar dispositivos de fibra monomodo a fibra multimodo. No son \u00fatiles en sistemas que usan \u00fanicamente fibra monomodo o \u00fanicamente fibra multimodo.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfC\u00f3mo puede alguien identificar qu\u00e9 extremo del cable es de fibra monomodo?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La mayor\u00eda de los cables tienen una funda amarilla o una etiqueta en el extremo de fibra monomodo. Los usuarios siempre deben verificar estas marcas antes de conectar el cable.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfQu\u00e9 ocurre si el cable se instala al rev\u00e9s?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Si alguien conecta el cable al rev\u00e9s, la red podr\u00eda no funcionar. La se\u00f1al puede debilitarse o perderse por completo. Siempre conecte el extremo de fibra monomodo al transceptor.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfLos cables de acondicionamiento de modo admiten redes de alta velocidad?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00ed, estos cables admiten enlaces de alta velocidad como Gigabit Ethernet y 10 Gigabit Ethernet. Ayudan a mantener las se\u00f1ales n\u00edtidas y fuertes en redes r\u00e1pidas.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Consejo: Siempre pruebe el enlace despu\u00e9s de instalar un cable de acondicionamiento de modo para asegurarse de que la conexi\u00f3n funcione correctamente.<\/p><\/blockquote>","protected":false},"excerpt":{"rendered":"<p>Los cables de conexi\u00f3n de acondicionamiento de modo permiten que los dispositivos monomodo funcionen con fibra multimodo, reduciendo la distorsi\u00f3n de la se\u00f1al y el retardo diferencial de modo en las redes.<\/p>","protected":false},"author":1,"featured_media":3815,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[27],"tags":[26],"class_list":["post-3818","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-glossary","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/3818","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/comments?post=3818"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/3818\/revisions"}],"predecessor-version":[{"id":11185,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/3818\/revisions\/11185"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/media\/3815"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/media?parent=3818"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/categories?post=3818"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/tags?post=3818"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}