{"id":3516,"date":"2025-12-02T00:00:00","date_gmt":"2025-12-02T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/ieee-802-3cd-50g-100g-200g-pam4-ethernet\/"},"modified":"2026-06-22T08:57:41","modified_gmt":"2026-06-22T08:57:41","slug":"ieee-802-3cd-50g-100g-200g-pam4-ethernet","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/ieee-802-3cd-50g-100g-200g-pam4-ethernet","title":{"rendered":"Explicaci\u00f3n de IEEE 802.3cd: Ethernet de 50G, 100G y 200G con PAM4"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540.webp\" alt=\"What Is IEEE 802.3cd?\" class=\"wp-image-3513\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/882b27eb378945618d369548c34c2540-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc \u00bfQu\u00e9 es IEEE 802.3cd?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">IEEE 802.3cd es el est\u00e1ndar Ethernet que define la Capa F\u00edsica (PHY) y <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/what-is-physical-medium-dependent-pmd\/\">como la Subcapa Dependiente del Medio F\u00edsico (PMD)<\/a> las especificaciones para <strong>redes de 50 GbE, 100 GbE y 200 GbE<\/strong> que utilizan <strong>canales de 50G PAM4<\/strong>. Finalizado en 2018, el est\u00e1ndar introdujo la se\u00f1alizaci\u00f3n de 50 G por una sola v\u00eda (single-lane 50G) y combinaciones de m\u00faltiples v\u00edas (2\u00d750G y 4\u00d750G), posibilitando Ethernet de alta velocidad escalable con mayor eficiencia de puertos y menor costo por bit.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">El est\u00e1ndar desempe\u00f1a un papel central en los centros de datos modernos, donde los transceptores \u00f3pticos PAM4 \u2014en particular, <strong>SFP56, <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491591.htm\"><strong>QSFP28<\/strong><\/a><strong>, QSFP56 y QSFP-DD<\/strong>\u2014se implementan ampliamente en las trayectorias de migraci\u00f3n de 25G a 200G.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Por qu\u00e9 IEEE 802.3cd utiliza la modulaci\u00f3n PAM4<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Una caracter\u00edstica definitoria de 802.3cd es la transici\u00f3n de NRZ (PAM2) a <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\"><strong>PAM4<\/strong> para codificar datos sobre la fase y amplitud de la onda de luz.<\/a>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Principales ventajas de PAM4<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Mayor densidad de datos:<\/strong> PAM4 codifica dos bits por s\u00edmbolo, duplicando efectivamente el rendimiento dentro del mismo ancho de banda.<\/p><\/li><li><p><strong>Factibilidad de 50G por una sola v\u00eda:<\/strong> Logra 50 Gb\/s por v\u00eda a una tasa de s\u00edmbolos de aproximadamente 50 GBd.<\/p><\/li><li><p><strong>Mejor escalabilidad:<\/strong> Permite la expansi\u00f3n de ancho de banda de 50G \u2192 100G \u2192 200G sin redise\u00f1ar los factores de forma de los puertos.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Con PAM4, Ethernet pudo evolucionar utilizando formatos de m\u00f3dulo familiares, al tiempo que soportaba velocidades agregadas mucho m\u00e1s altas.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc PMD e interfaces definidos bajo IEEE 802.3cd<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >PMD de 50 GbE<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>50GBASE-SR<\/strong> \u2013 Fibra multimodo de corto alcance que utiliza una \u00fanica v\u00eda PAM4 de 50G.<\/p><\/li><li><p><strong>50GBASE-FR<\/strong> \u2013 Fibra monomodo, t\u00edpicamente hasta 2 km.<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491591.htm\"><strong>50GBASE-LR<\/strong><\/a> \u2013 Fibra monomodo con alcance de 10 km para aplicaciones en campus y metropolitanas.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >PMD de 100 GbE (2\u00d750G)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>100GBASE-FR2<\/strong> \u2013 Dos v\u00edas PAM4 sobre fibra monomodo, con alcance moderado.<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491583.htm\"><strong>100GBASE-LR2<\/strong><\/a> \u2013 Aplicaciones de larga distancia sobre fibra monomodo con dos v\u00edas.<\/p><\/li><li><p><strong>100GBASE-DR\/DR2<\/strong> \u2013 Optimizado para enlaces de fibra monomodo de corto a medio alcance en centros de datos.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >PMD de 200 GbE (4\u00d750G)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473139.htm\"><strong>200GBASE-SR4<\/strong><\/a> \u2013 Cuatro v\u00edas de 50G sobre fibra multimodo paralela; ideal para conectividad de alta densidad entre nodos leaf\/spine.<\/p><\/li><li><p><strong>200GBASE-FR4 \/ LR4<\/strong> \u2013 Soluciones de cuatro v\u00edas sobre fibra monomodo que permiten alcances de 2 km y 10 km, respectivamente.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">3cd define par\u00e1metros el\u00e9ctricos y \u00f3pticos para estas interfaces, incluidos TDECQ, OMAouter del transmisor, sensibilidad del receptor y objetivos de BER por v\u00eda.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Casos de uso de implementaci\u00f3n en centros de datos modernos<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >50G por una sola v\u00eda para servidores<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Muchos centros de datos hipercalables y empresariales adoptan <strong>50G SFP56<\/strong> interfaces para enlaces de acceso a servidores, reemplazando al 25G como ancho de banda est\u00e1ndar por nodo.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >100G como capa de enlace ascendente<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Mediante 2\u00d750G lanes, los enlaces de 100G siguen siendo una capa primaria de agregaci\u00f3n entre los switches Top-of-Rack (ToR) y los switches leaf. <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472577.htm\">QSFP28 de 100 G<\/a> o m\u00f3dulos SFP-DD ofrecen densidad eficiente y compatibilidad hacia atr\u00e1s.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >200G para las redes leaf-to-spine<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473139.htm\">200G QSFP56<\/a> o transceptores QSFP-DD permiten arquitecturas de cuatro lanes de 50G con flexibilidad de breakout. Un solo puerto de 200G puede dividirse en <strong>4\u00d750G<\/strong> para servidores o nodos de agregaci\u00f3n.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Flexibilidad de breakout<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La arquitectura basada en lanes hace que el est\u00e1ndar 802.3cd sea ideal para:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>200G QSFP56 \u2192 4\u00d750G SFP56<\/p><\/li><li><p>100G QSFP28 \u2192 2\u00d750G SFP56<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Esto se alinea perfectamente con la transici\u00f3n de servidores de 25G a 50G de pr\u00f3xima generaci\u00f3n.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Selecci\u00f3n de los transceptores \u00f3pticos adecuados para IEEE 802.3cd<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480.webp\" alt=\"802.3cd-compliant optical transceivers\" class=\"wp-image-3514\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6e8b859454564c7783bcadfeaf9ad480-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Al planificar una red de 50G\/100G\/200G, la selecci\u00f3n de transceptores debe coincidir con el <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/what-is-physical-medium-dependent-pmd\/\">PMD<\/a> tipo, alcance en fibra y factor de forma del puerto del switch.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para despliegues IEEE 802.3cd, LINK-PP ofrece las siguientes categor\u00edas de productos:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Transceptores \u00f3pticos de 50G (SFP56 \/ QSFP28)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Para 50GBASE-SR\/FR\/LR de una sola lane y acceso a servidores de 50G:<br\/>\ud83d\udd17 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27046-50g-qsfp28-sfp56.htm\">https:\/\/www.l-p.com\/store-27046-50g-qsfp28-sfp56.htm<\/a><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Transceptores \u00f3pticos de 100G (QSFP28 \/ SFP-DD)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ideales para enlaces ascendentes de 2\u00d750G, agregaci\u00f3n spine de 100G y aplicaciones DR\/FR\/LR:<br\/>\ud83d\udd17 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\">https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm<\/a><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Transceptores \u00f3pticos de 200G (QSFP-DD \/ QSFP56)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Dise\u00f1ados para redes leaf-spine de 4\u00d750G y compatibilidad con breakout:<br\/>\ud83d\udd17 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26224-200g-qsfp-dd-qsfp56.htm\">https:\/\/www.l-p.com\/store-26224-200g-qsfp-dd-qsfp56.htm<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Estos m\u00f3dulos soportan se\u00f1alizaci\u00f3n PAM4 y cumplen con los objetivos de interoperabilidad IEEE, tales como el rendimiento TDECQ, la sensibilidad del receptor y la consistencia del BER por lane.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Lista de verificaci\u00f3n de interoperabilidad y validaci\u00f3n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Para garantizar un despliegue fiable de 802.3cd, los ingenieros suelen verificar:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>El tipo correcto de PMD<\/strong> (SR, FR, LR, DR) para el presupuesto de enlace y el alcance.<\/p><\/li><li><p><strong>Coincidencia del factor de forma<\/strong> (SFP56, QSFP28, QSFP56, QSFP-DD).<\/p><\/li><li><p><strong>Optical power levels<\/strong> incluyendo OMAouter y potencia media de emisi\u00f3n.<\/p><\/li><li><p><strong>Sensibilidad del receptor<\/strong> bajo condiciones PAM4 estresadas.<\/p><\/li><li><p><strong>Objetivos de BER por lane<\/strong> and <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/fec-forward-error-correction-in-optical-communication\/\">FEC<\/a> compatibilidad.<\/p><\/li><li><p><strong>Asignaci\u00f3n de breakout<\/strong> al combinar puntos finales de 200G \u2194 50G.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Conclusi\u00f3n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">IEEE 802.3cd estableci\u00f3 los bloques t\u00e9cnicos fundamentales para el <strong>Ethernet de 50G, 100G y 200G<\/strong>, actuales, trayendo <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\">modulaci\u00f3n PAM4<\/a> en la implementaci\u00f3n generalizada. Su arquitectura basada en carriles permite actualizaciones escalables y rentables del ancho de banda, manteniendo formatos de m\u00f3dulo familiares.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A medida que los centros de datos siguen migrando de 25G y 40G a redes de mayor velocidad, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473139.htm\">transceptores \u00f3pticos compatibles con IEEE 802.3cd<\/a>\u2014como las familias de productos de 50G\/100G\/200G de LINK-PP\u2014ofrecen una base fiable para la conectividad de pr\u00f3xima generaci\u00f3n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para especificaciones detalladas y selecci\u00f3n de productos, explore <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">LINK-PP's<\/a> toda la gama de transceptores compatibles con IEEE 802.3cd.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc T\u00e9rminos \u00f3pticos y el\u00e9ctricos clave en IEEE 802.3cd (glosario breve)<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2605 TDECQ (cierre del ojo por dispersi\u00f3n y transmisor para PAM4)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">El TDECQ es una m\u00e9trica de calidad del transmisor utilizada en interfaces basadas en PAM4. Cuantifica cu\u00e1nto se \u201ccierra\u201d el diagrama de ojo \u00f3ptico tras sufrir el se\u00f1al dispersi\u00f3n, ruido y otras alteraciones del canal. Un <strong>valor m\u00e1s bajo de TDECQ<\/strong> indica una se\u00f1al PAM4 m\u00e1s limpia y con mayor margen de enlace. IEEE 802.3cd utiliza el TDECQ como requisito principal para transmisores \u00f3pticos de 50G, 100G y 200G.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2605 OMAouter (amplitud de modulaci\u00f3n \u00f3ptica exterior)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">OMAouter representa la <strong>diferencia entre los niveles de potencia \u00f3ptica m\u00e1s alto y m\u00e1s bajo<\/strong> (nivel 3 y nivel 0) en una se\u00f1al PAM4. Dado que PAM4 utiliza cuatro niveles discretos, OMAouter ofrece una representaci\u00f3n m\u00e1s precisa de la profundidad de modulaci\u00f3n que la potencia promedio. Una <strong>OMAouter m\u00e1s alta<\/strong> generalmente mejora la sensibilidad del receptor y ayuda a garantizar un rendimiento conforme a las normas para 50GBASE-SR\/FR\/LR y variantes de m\u00faltiples carriles.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2605 BER (Tasa de errores de bits)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/understanding-what-is-bit-error-rate\/\">BER<\/a> mide la relaci\u00f3n entre los bits err\u00f3neos y el n\u00famero total de bits transmitidos. IEEE 802.3cd especifica <strong>objetivos de BER por carril<\/strong>, t\u00edpicamente utilizando un <strong>objetivo de BER previo a la correcci\u00f3n de errores (FEC) de 2,4\u00d710\u207b\u2074<\/strong> para carriles PAM4. Con una fuerte correcci\u00f3n de errores hacia adelante (como la FEC KP4), el BER posterior a la FEC alcanza la confiabilidad requerida para redes de centros de datos hipercalados y en la nube.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccc Preguntas frecuentes (FAQ)<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfQu\u00e9 es IEEE 802.3cd?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">IEEE 802.3cd es un est\u00e1ndar Ethernet que define las especificaciones de la capa f\u00edsica para <strong>50GbE, 100GbE y 200GbE<\/strong> mediante <strong>modulaci\u00f3n PAM4<\/strong>. Incluye interfaces como <strong>50GBASE-SR\/FR\/LR<\/strong>, <strong>100GBASE-SR2<\/strong>, and <strong>200GBASE-SR4<\/strong>, orientadas a entornos modernos de centros de datos y redes de alto rendimiento.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfQu\u00e9 formato de modulaci\u00f3n utiliza IEEE 802.3cd?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">IEEE 802.3cd exige <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/what-is-physical-medium-dependent-pmd\/\"><strong>PAM4 (modulaci\u00f3n por amplitud de pulso de 4 niveles)<\/strong><\/a> para todas las interfaces de 50 G por carril. PAM4 duplica la velocidad de transmisi\u00f3n de bits por carril en comparaci\u00f3n con NRZ, manteniendo la misma tasa de baudios, lo que posibilita arquitecturas escalables de Ethernet de 50 G, 100 G y 200 G.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfAdmite IEEE 802.3cd compatibilidad inversa con NRZ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00ed, en muchos despliegues los enlaces basados en PAM4 pueden coexistir con interfaces NRZ <strong>siempre que el puerto host, la interfaz el\u00e9ctrica y el m\u00f3dulo \u00f3ptico est\u00e9n dise\u00f1ados para soportar entornos mixtos<\/strong>. Sin embargo, PAM4 y NRZ no pueden interoperar en un solo enlace; ambos extremos deben utilizar el mismo formato de modulaci\u00f3n.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfCu\u00e1les son los casos de uso t\u00edpicos de IEEE 802.3cd?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">IEEE 802.3cd se utiliza ampliamente para:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>acceso de servidores a 50 G (SFP56, QSFP28)<\/p><\/li><li><p>capas de espina\/agregaci\u00f3n a 100 G<\/p><\/li><li><p>redes hoja-espina a 200 G<\/p><\/li><li><p>nubes, cl\u00fasteres de IA\/ML y redes hipercaladas<\/p><\/li><li><p>enlaces ascendentes de 50 G por carril en arquitecturas modulares (2\u00d750 G, 4\u00d750 G)<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfQu\u00e9 transceptores \u00f3pticos cumplen con IEEE 802.3cd?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">IEEE 802.3cd admite una amplia gama de m\u00f3dulos \u00f3pticos de 50 G, 100 G y 200 G, incluidos:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>50GBASE-SR\/FR\/LR<\/strong> (SFP56 \/ QSFP28) para 50GbE de un solo carril<\/p><\/li><li><p><strong>100GBASE-SR2<\/strong> y m\u00f3dulos de divisi\u00f3n 2\u00d750G (QSFP28 \/ SFP-DD)<\/p><\/li><li><p><strong>200GBASE-SR4\/DR4\/FR4<\/strong> (QSFP-DD \/ QSFP56)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">LINK-PP<\/a> ofrece opciones conformes con IEEE 802.3cd en todas las clases de velocidad.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfC\u00f3mo se relaciona IEEE 802.3cd con IEEE 802.3bs (400 G) y 802.3cu?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/ieee-802-3bs-200g-400g-ethernet-standard\/\"><strong>3bs<\/strong><\/a> define 400GbE y tambi\u00e9n se basa en carriles de 50 G, pero se centra en arquitecturas con mayor cantidad de carriles (por ejemplo, 8\u00d750 G).<\/p><\/li><li><p><strong>3cu<\/strong> extiende 100 G\/400 G a aplicaciones de fibra monomodo (SMF) de mayor alcance (DR\/FR\/LR).<\/p><\/li><li><p><strong>3cd<\/strong> cubre la brecha para <strong>Ethernet de 50 G por carril, tanto de un solo carril como de m\u00faltiples carriles<\/strong>, permitiendo trayectorias de migraci\u00f3n escalables desde 25 G \u2192 50 G \u2192 100 G\/200 G \u2192 400 G.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfEs adecuado IEEE 802.3cd para cargas de trabajo de IA\/ML y computaci\u00f3n de alto rendimiento (HPC) de pr\u00f3xima generaci\u00f3n?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00ed. La <strong>arquitectura PAM4 de 50 G por carril del est\u00e1ndar<\/strong> se alinea con las redes de alta capacidad utilizadas en cl\u00fasteres de IA, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/what-is-hpc-high-performance-computing\/\">Los sistemas HPC<\/a>, y redes masivas de GPU. Permite topolog\u00edas hoja-espina de baja latencia con opciones flexibles de divisi\u00f3n, como 4\u00d750 G o 2\u00d7100 G.<\/p>","protected":false},"excerpt":{"rendered":"<p>Aprenda qu\u00e9 define IEEE 802.3cd para Ethernet de 50G, 100G y 200G. Explore la tecnolog\u00eda PAM4, los PMD clave, los casos de uso de implementaci\u00f3n y los transceptores \u00f3pticos LINK-PP adecuados.<\/p>","protected":false},"author":1,"featured_media":3515,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13,24,26],"class_list":["post-3516","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules","tag-link-pp","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/3516","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/comments?post=3516"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/3516\/revisions"}],"predecessor-version":[{"id":11328,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/3516\/revisions\/11328"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/media\/3515"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/media?parent=3516"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/categories?post=3516"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/tags?post=3516"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}