{"id":3288,"date":"2026-02-07T00:00:00","date_gmt":"2026-02-07T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/what-is-qsfp-dd-400g-transceiver\/"},"modified":"2026-06-22T04:13:50","modified_gmt":"2026-06-22T04:13:50","slug":"what-is-qsfp-dd-400g-transceiver","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/what-is-qsfp-dd-400g-transceiver","title":{"rendered":"\u00bfQu\u00e9 es QSFP-DD? Especificaciones, arquitectura y casos de uso de 400 G"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"628\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/783dcec9f5e14b6d82a95444e3da61e7.jpg\" alt=\"What Is QSFP-DD\" class=\"wp-image-3276\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/783dcec9f5e14b6d82a95444e3da61e7.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/783dcec9f5e14b6d82a95444e3da61e7-300x157.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/783dcec9f5e14b6d82a95444e3da61e7-1024x536.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/783dcec9f5e14b6d82a95444e3da61e7-768x402.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/783dcec9f5e14b6d82a95444e3da61e7-18x9.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">A medida que el tr\u00e1fico de los centros de datos sigue aumentando \u2014impulsado por la computaci\u00f3n en la nube, las cargas de trabajo de inteligencia artificial y la computaci\u00f3n de alto rendimiento (HPC)\u2014, la infraestructura de red debe escalar mucho m\u00e1s all\u00e1 del Ethernet tradicional de 100 G. Actualmente, los ASIC de conmutaci\u00f3n modernos ofrecen capacidades de conmutaci\u00f3n superiores a 12,8 Tbps, lo que genera una demanda de soluciones de interconexi\u00f3n \u00f3ptica de mayor densidad.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>QSFP-DD (Quad Small Form-factor Pluggable Double Density)<\/strong> es un formato de factor de forma de ocho canales <a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-26045-400g-qsfp-dd-osfp-qsfp112.htm\">m\u00f3dulo \u00f3ptico enchufable<\/a> dise\u00f1ado para habilitar <strong>400 G y velocidades superiores<\/strong> manteniendo una huella mec\u00e1nica similar a la de los m\u00f3dulos QSFP anteriores. Al duplicar la interfaz el\u00e9ctrica de cuatro canales a ocho canales, el m\u00f3dulo 400G permite a los ingenieros de red aumentar dr\u00e1sticamente el ancho de banda del panel frontal sin incrementar el tama\u00f1o del conmutador ni el espaciado entre puertos.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Actualmente, QSFP-DD se ha convertido en una de las soluciones m\u00e1s ampliamente adoptadas para centros de datos hipercalibrados, redes de tejido para cl\u00fasteres de IA y redes de agregaci\u00f3n de clase operadora.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u21aa\ufe0f\u00a0<\/strong>\u00bfQu\u00e9 es QSFP-DD?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472016.htm\">QSFP-DD<\/a> (Quad Small Form-factor Pluggable \u2013 Doble Densidad) es un formato de factor de forma de transceptor \u00f3ptico extra\u00edble de ocho canales, dise\u00f1ado para escalar el ancho de banda de Ethernet y las interconexiones de centros de datos hasta <strong>400G<\/strong> y velocidades emergentes <strong>800G<\/strong> ampl\u00eda la interfaz el\u00e9ctrica tradicional QSFP de <strong>cuatro canales a ocho canales<\/strong>, duplicando efectivamente el ancho de banda disponible dentro de la misma huella compacta.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">El t\u00e9rmino <strong>\u201cdoble densidad\u201d<\/strong> hace referencia a esta arquitectura el\u00e9ctrica expandida. Al agregar una segunda fila de contactos el\u00e9ctricos de alta velocidad, QSFP-DD ofrece mayores tasas de datos agregadas mientras <strong>mantiene la compatibilidad mec\u00e1nica hacia atr\u00e1s<\/strong> con los m\u00f3dulos <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/491590.htm\">QSFP+<\/a>, <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/491591.htm\">QSFP28<\/a>, and <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/473139.htm\">QSFP56<\/a> existentes. Esto permite una migraci\u00f3n fluida para los operadores de centros de datos sin necesidad de redise\u00f1ar por completo los puertos del conmutador ni la infraestructura de cableado.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5a4db047f5c84901b0b1e10f4f5cb77e.jpg\" alt=\"What Is QSFP-DD, Key Characteristics\" class=\"wp-image-3277\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5a4db047f5c84901b0b1e10f4f5cb77e.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5a4db047f5c84901b0b1e10f4f5cb77e-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5a4db047f5c84901b0b1e10f4f5cb77e-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5a4db047f5c84901b0b1e10f4f5cb77e-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5a4db047f5c84901b0b1e10f4f5cb77e-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Caracter\u00edsticas clave de QSFP-DD<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Ocho canales el\u00e9ctricos de alta velocidad<\/strong> para una mayor densidad de ancho de banda<\/p><\/li><li><p><strong>Admite <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\"><strong>PAM4<\/strong><\/a><strong> y modulaci\u00f3n NRZ heredada <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/understanding-non-return-to-zero-in-digital-communication\/\"><strong>, seg\u00fan la velocidad y la aplicaci\u00f3n<\/strong><\/a>, Dise\u00f1ado para Ethernet de 200 G, 400 G y 800 G emergente<\/p><\/li><li><p><strong>Compatibilidad mec\u00e1nica hacia atr\u00e1s<\/strong> despliegues<\/p><\/li><li><p><strong>con los m\u00f3dulos QSFP+\/QSFP28<\/strong> Optimizado para centros de datos hipercalibrados e infraestructuras de IA\/ML<\/p><\/li><li><p><strong>, donde la densidad de puertos y la eficiencia energ\u00e9tica son cr\u00edticas<\/strong>, where port density and power efficiency are critical<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Hoy en d\u00eda, QSFP-DD est\u00e1 ampliamente adoptado como la plataforma principal de \u00f3ptica enchufable de 400 G en entornos modernos de conmutaci\u00f3n de centros de datos, constituyendo la base para redes escalables de nube, IA y computaci\u00f3n de alto rendimiento.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u21aa\ufe0f\u00a0<\/strong>\u00bfQu\u00e9 problema resuelve QSFP-DD?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Como conmutador <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/what-is-application-specific-integrated-circuit-asic\/\">ASIC<\/a> El ancho de banda aument\u00f3 r\u00e1pidamente m\u00e1s all\u00e1 de 12,8 Tbps, y los m\u00f3dulos QSFP28 tradicionales \u2014limitados a cuatro pistas el\u00e9ctricas\u2014 se convirtieron en un cuello de botella para la escalabilidad.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c0b24c0e85b24ceaac39641a6458741b.jpg\" alt=\"What Problem Does QSFP-DD Solve?\" class=\"wp-image-3278\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c0b24c0e85b24ceaac39641a6458741b.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c0b24c0e85b24ceaac39641a6458741b-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c0b24c0e85b24ceaac39641a6458741b-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c0b24c0e85b24ceaac39641a6458741b-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c0b24c0e85b24ceaac39641a6458741b-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP-DD aborda tres desaf\u00edos fundamentales en las implementaciones modernas de redes de alta velocidad:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Limitaciones de densidad de puertos en el panel frontal<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Los factores de forma QSFP convencionales restringen la cantidad de ancho de banda que puede entregarse por puerto del conmutador. Aumentar el rendimiento del conmutador sin incrementar el tama\u00f1o del chasis requiere mayor ancho de banda por puerto. QSFP-DD resuelve esto al permitir la transmisi\u00f3n de 400 G manteniendo dimensiones de puerto similares.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Desajuste en el n\u00famero de pistas el\u00e9ctricas<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Los ASIC de pr\u00f3xima generaci\u00f3n admiten mayores <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/serdes-interfaces-high-speed-data-transfer-and-signal-integrity\/\">SerDes<\/a> recuentos y velocidades de pistas. QSFP-DD se alinea con estas plataformas al expandirse a <strong>ocho pistas el\u00e9ctricas<\/strong>, lo que permite una asignaci\u00f3n eficiente entre las pistas del ASIC host y las interfaces \u00f3pticas.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Restricciones de potencia y t\u00e9rmicas<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un mayor ancho de banda requiere una mayor capacidad de <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/digital-signal-processor-functionality-in-optical-transceivers\/\">procesamiento de se\u00f1ales digitales<\/a> (DSP) y correcci\u00f3n de errores hacia adelante (FEC). El transceptor de 400 G est\u00e1 dise\u00f1ado para satisfacer estos requisitos, equilibrando al mismo tiempo las restricciones de refrigeraci\u00f3n y flujo de aire en implementaciones de alta densidad.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Al duplicar la interfaz el\u00e9ctrica a ocho pistas, QSFP-DD posibilita un rendimiento de 400 G sin aumentar la huella frontal, lo que permite a los centros de datos escalar su capacidad dentro de las restricciones existentes de infraestructura.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Qu\u00e9 deben verificar los ingenieros antes de adoptar QSFP-DD<\/h3>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p><strong>Soporte de plataforma:<\/strong> Confirme que el ASIC y el firmware del conmutador admitan el esquema de pines el\u00e9ctricos y los modos de divisi\u00f3n (breakout) de QSFP-DD.<\/p><\/li><li><p><strong>Presupuesto de potencia:<\/strong> Verifique el margen de potencia por puerto y a nivel de chasis para el consumo m\u00e1ximo del m\u00f3dulo.<\/p><\/li><li><p><strong>Plan t\u00e9rmico:<\/strong> Valide el flujo de aire, las curvas de los ventiladores y las alarmas de temperatura bajo tr\u00e1fico sostenido.<\/p><\/li><li><p><strong>Integridad de se\u00f1al:<\/strong> Revise las longitudes de las pistas del host y las especificaciones del conector; prefiera trayectos cortos con impedancia controlada para las pistas PAM4.<\/p><\/li><li><p><strong>Pruebas de interoperabilidad:<\/strong> Ejecutar pruebas mutuas entre proveedores (matriz de compatibilidad, prueba de estr\u00e9s y validaci\u00f3n del margen de enlace) antes de la implementaci\u00f3n en producci\u00f3n.<\/p><\/li><li><p><strong>Supervisi\u00f3n:<\/strong> Asegurar que la telemetr\u00eda DOM\/diagn\u00f3stica para temperatura, voltaje y potencia \u00f3ptica est\u00e9 soportada e integrada en los sistemas de gesti\u00f3n de red (NMS)\/supervisi\u00f3n.<\/p><\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u21aa\ufe0f\u00a0<\/strong>Especificaciones t\u00e9cnicas clave de QSFP-DD<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472202.htm\">400G QSFP-DD<\/a> Admite m\u00faltiples velocidades por canal y tecnolog\u00edas de modulaci\u00f3n para permitir dise\u00f1os flexibles de interconexi\u00f3n de alta velocidad.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/153a9da94b624c3cb7aa0a52d50fa497.jpg\" alt=\"QSFP-DD Key Technical Specifications\" class=\"wp-image-3279\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/153a9da94b624c3cb7aa0a52d50fa497.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/153a9da94b624c3cb7aa0a52d50fa497-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/153a9da94b624c3cb7aa0a52d50fa497-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/153a9da94b624c3cb7aa0a52d50fa497-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/153a9da94b624c3cb7aa0a52d50fa497-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Par\u00e1metro<br><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>QSFP-DD<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Carriles el\u00e9ctricos<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>8<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Velocidad por canal<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>25G \/ 50G PAM4<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Tasa de datos agregada<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>200G \/ 400G \/ 800G<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Modulaci\u00f3n<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>NRZ (heredado), PAM4<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Conector<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Conector de borde QSFP-DD<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Compatibilidad hacia atr\u00e1s<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>QSFP+, QSFP28 (soporte para carcasa y adaptador)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Uso t\u00edpico<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Conmutaci\u00f3n espina-hoja en centros de datos<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Explicaciones detalladas y valores pr\u00e1cticos<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Canales el\u00e9ctricos y velocidad por canal<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>ASK modula los datos variando la<\/strong> QSFP-DD incrementa el n\u00famero de canales el\u00e9ctricos de alta velocidad presentados al host de 4 (QSFP28) a <strong>8 canales<\/strong>.<\/p><\/li><li><p><strong>Velocidades pr\u00e1cticas por canal:<\/strong> 25G NRZ (heredado \/ enlaces m\u00e1s lentos), <strong>50G PAM4<\/strong> (com\u00fan para 400G) y <strong>PAM4 de 100 G<\/strong> (usado en muchos experimentos\/implementaciones de 800G).<\/p><\/li><li><p><strong>Impacto en el dise\u00f1o:<\/strong> El trazado de la PCB del host, la calidad del conector y la configuraci\u00f3n del SerDes deben soportar la velocidad por canal y el tipo de se\u00f1alizaci\u00f3n elegidos.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Tasas de datos agregadas<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>C\u00f3mo se forma la tasa agregada:<\/strong> tasa agregada = (n\u00famero de canales) \u00d7 (velocidad por canal). Ejemplo: 8 \u00d7 50G = 400G.<\/p><\/li><li><p><strong>Agregaciones comunes:<\/strong> 200G (por ejemplo, 8 \u00d7 25G), 400G (8 \u00d7 50G), 800G (8 \u00d7 100G u otras agrupaciones de canales).<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Modulaci\u00f3n (<\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/what-is-the-difference-between-nrz-and-pam4\/\"><strong>NRZ frente a PAM4<\/strong><\/a><strong>)<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>NRZ (sin retorno a cero):<\/strong> M\u00e1s sencilla, utilizada hist\u00f3ricamente a 10\/25\/28G por canal.<\/p><\/li><li><p><strong>PAM4 (modulaci\u00f3n por amplitud de pulsos de 4 niveles):<\/strong> Duplica los bits por s\u00edmbolo respecto a NRZ, permitiendo 50G\/100G por canal con la misma tasa de baudios, pero requiere procesamiento digital de se\u00f1ales (DSP) avanzado, ecualizaci\u00f3n m\u00e1s potente y correcci\u00f3n de errores (FEC) m\u00e1s robusta.<\/p><\/li><li><p><strong>Consecuencia pr\u00e1ctica:<\/strong> PAM4 incrementa la complejidad, el consumo de energ\u00eda del m\u00f3dulo y los requisitos de relaci\u00f3n se\u00f1al-ruido (SNR) del canal y ecualizaci\u00f3n.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Conector y factor de forma mec\u00e1nico<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Conector QSFP-DD:<\/strong> Utiliza una matriz de contactos de doble fila (densidad doble) dentro de una carcasa del tama\u00f1o de QSFP para transportar 8 canales de alta velocidad.<\/p><\/li><li><p><strong>Compatibilidad mec\u00e1nica:<\/strong> Muchas carcasas QSFP-DD aceptan mec\u00e1nicamente m\u00f3dulos QSFP28\/QSFP+, pero <strong>compatibilidad funcional<\/strong> depende del cableado de la placa de circuito impreso (PCB) del host y del soporte del firmware (v\u00e9ase la secci\u00f3n de compatibilidad).<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Advertencia sobre compatibilidad hacia atr\u00e1s<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Mec\u00e1nico frente a funcional:<\/strong> <a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-24695-qsfp-dd-cages-connectors.htm\">Caja QSFP-DD<\/a> est\u00e1 dise\u00f1ado intencionalmente para aceptar mec\u00e1nicamente el formato QSFP anterior, pero debe verificar que la <strong>placa host \/ ASIC \/ firmware<\/strong> admitan la asignaci\u00f3n el\u00e9ctrica y la negociaci\u00f3n de velocidad requeridas para los m\u00f3dulos anteriores.<\/p><\/li><li><p><strong>Comportamiento de divisi\u00f3n (breakout):<\/strong> algunas plataformas admiten modos de divisi\u00f3n (por ejemplo, 1\u00d7400 G \u2192 4\u00d7100 G), pero esto depende de las implementaciones del ASIC y del firmware.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Consumo de energ\u00eda (rangos t\u00edpicos)<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/473115.htm\"><strong>QSFP28 100 G<\/strong><\/a><strong>:<\/strong> ~3,5\u20134,5 W (punto de referencia)<\/p><\/li><li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472208.htm\"><strong>M\u00f3dulos QSFP-DD de 400 G<\/strong><\/a><strong>:<\/strong> los m\u00f3dulos t\u00edpicos de producci\u00f3n consumen com\u00fanmente <strong>~10\u201314 W<\/strong>; dise\u00f1e para el peor caso (especificaci\u00f3n m\u00e1xima del fabricante) al planificar los presupuestos de energ\u00eda y t\u00e9rmicos.<\/p><\/li><li><p><strong>QSFP-DD de 800 G:<\/strong> los chips\/m\u00f3dulos iniciales pueden consumir <strong>16\u201320 W<\/strong> o m\u00e1s.<\/p><\/li><li><p><strong>Nota de dise\u00f1o:<\/strong> utilice el consumo de energ\u00eda por m\u00f3dulo en el peor caso para el dise\u00f1o de la fuente de alimentaci\u00f3n del chasis y la planificaci\u00f3n t\u00e9rmica; tanto las cargas transitorias como las sostenidas son relevantes.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Interfaces \u00f3pticas y alcance (asignaciones t\u00edpicas de 400 G)<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>SR8 (fibra multimodo, MMF):<\/strong> alcance corto, normalmente hasta ~100 m sobre fibra multimodo OM4\/OM5 mediante conectores MPO\/MTP.<\/p><\/li><li><p><strong>DR4 (fibra monomodo, SMF):<\/strong> ~500 m en fibra monomodo (4 canales de 100 G o equivalente).<\/p><\/li><li><p><strong>FR4 (SMF):<\/strong> clase de ~2 km.<\/p><\/li><li><p><strong>LR4 (SMF):<\/strong> clase de ~10 km.<br\/>(El alcance real depende de las \u00f3pticas del proveedor, el tipo de fibra, el presupuesto de enlace, las p\u00e9rdidas en conectores\/empalmes y la correcci\u00f3n de errores FEC.)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Diagn\u00f3sticos y gesti\u00f3n<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>DDM\/DOM:<\/strong> los m\u00f3dulos QSFP-DD exponen diagn\u00f3sticos digitales (accesibles mediante I\u00b2C) para temperatura, voltaje de alimentaci\u00f3n, corriente de polarizaci\u00f3n del l\u00e1ser, potencia \u00f3ptica de transmisi\u00f3n\/recepci\u00f3n, etc. Integre la telemetr\u00eda en el <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/network-management-system-nms-monitoring-control-security\/\">sistema de gesti\u00f3n de red (NMS)<\/a> para una supervisi\u00f3n proactiva.<\/p><\/li><li><p><strong>Mejores pr\u00e1cticas de telemetr\u00eda:<\/strong> establezca umbrales conservadores de alarma\/cr\u00edtico y valide su comportamiento frente a la regulaci\u00f3n t\u00e9rmica (throttling).<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Integridad de se\u00f1al y dise\u00f1o del canal<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Sensibilidad del canal:<\/strong> 8 pistas con modulaci\u00f3n PAM4 amplifican los requisitos de integridad de se\u00f1al: es esencial el enrutamiento con impedancia controlada, la minimizaci\u00f3n de longitudes de pista, el cuidado en los stubs de v\u00edas y el uso de conectores de alta calidad.<\/p><\/li><li><p><strong>Funci\u00f3n del DSP\/FEC:<\/strong> el DSP y la correcci\u00f3n de errores FEC integrados en el m\u00f3dulo compensan las distorsiones del canal, pero no sustituyen una ingenier\u00eda adecuada del canal.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Normas y ecosistema<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/optical-transceivers-msa-standards-guide\/\"><strong>Acuerdos de implementaci\u00f3n multiempresa (MSA)<\/strong><\/a><strong> &amp; <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/ieee-institute-of-electrical-and-electronics-engineers\/\"><strong>IEEE<\/strong><\/a><strong>:<\/strong> Los detalles mec\u00e1nicos\/el\u00e9ctricos de QSFP-DD est\u00e1n definidos en el acuerdo multifuente (MSA) de QSFP-DD; las interfaces f\u00edsicas \u00f3pticas (PHY) y los m\u00f3dulos de transmisi\u00f3n\/recepci\u00f3n \u00f3pticos (PMD) de 400 G est\u00e1n definidos en IEEE 802.3 (p. ej., especificaciones 400GBASE). Utilice los documentos del MSA y las normas IEEE como referencias autorizadas al validar dise\u00f1os y afirmaciones.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Qu\u00e9 verificar para cada uno <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472204.htm\">M\u00f3dulo QSFP-DD<\/a><\/h3>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p><strong>Configuraci\u00f3n de canales:<\/strong> confirmar el n\u00famero de canales y la velocidad por canal (p. ej., 8 \u00d7 50 G PAM4).<\/p><\/li><li><p><strong>Clase de potencia:<\/strong> verificar la disipaci\u00f3n de potencia t\u00edpica y m\u00e1xima; planificar la alimentaci\u00f3n del chasis y las fuentes de alimentaci\u00f3n (PSU) en consecuencia.<\/p><\/li><li><p><strong>Envoltura t\u00e9rmica:<\/strong> validar la disipaci\u00f3n t\u00e9rmica del m\u00f3dulo y los requisitos de flujo de aire del equipo anfitri\u00f3n.<\/p><\/li><li><p><strong>Interfaz \u00f3ptica y alcance:<\/strong> asignaci\u00f3n y presupuesto de enlace para SR8\/DR4\/FR4\/LR4 (potencias de transmisi\u00f3n\/recepci\u00f3n, sensibilidad del receptor).<\/p><\/li><li><p><strong>Correcci\u00f3n de errores hacia adelante (FEC) y procesamiento digital de se\u00f1ales (DSP):<\/strong> verificar el modo requerido <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/fec-forward-error-correction-in-optical-communication\/\">FEC<\/a> y cualquier implicaci\u00f3n en latencia.<\/p><\/li><li><p><strong>Compatibilidad:<\/strong> confirmar el soporte del ASIC anfitri\u00f3n, los modos de divisi\u00f3n (breakout) y la compatibilidad del firmware.<\/p><\/li><li><p><strong>Integridad de se\u00f1al:<\/strong> revisar la longitud de las pistas del equipo anfitri\u00f3n, la especificaci\u00f3n del conector\/jaula y los ajustes necesarios de ecualizaci\u00f3n SerDes.<\/p><\/li><li><p><strong>Telemetr\u00eda:<\/strong> garantizar la asignaci\u00f3n I\u00b2C de DOM\/DDM y la integraci\u00f3n con el sistema de gesti\u00f3n de red (NMS).<\/p><\/li><li><p><strong>Pruebas de interoperabilidad:<\/strong> ejecutar pruebas de envejecimiento (burn-in) de la plataforma y pruebas de enlace mutuo bajo condiciones t\u00e9rmicas y de potencia cr\u00edticas.<\/p><\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u21aa\ufe0f\u00a0<\/strong>Arquitectura el\u00e9ctrica QSFP-DD explicada<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP-DD (\u00abQuad Small Form Factor Pluggable \u2013 Double Density\u00bb) logra un mayor ancho de banda por puerto al <strong>duplicar el n\u00famero de canales el\u00e9ctricos de 4 a 8<\/strong> dentro del mismo factor de forma QSFP. Este cambio arquitect\u00f3nico permite que los ASIC de conmutaci\u00f3n de pr\u00f3xima generaci\u00f3n escalen m\u00e1s all\u00e1 de 100 G sin aumentar el ancho del panel frontal.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd96cd1546c344068df2f034d931c536.jpg\" alt=\"QSFP-DD Electrical Architecture, Block Diagram\" class=\"wp-image-3280\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd96cd1546c344068df2f034d931c536.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd96cd1546c344068df2f034d931c536-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd96cd1546c344068df2f034d931c536-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd96cd1546c344068df2f034d931c536-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd96cd1546c344068df2f034d931c536-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2666 Comparaci\u00f3n de disposici\u00f3n de canales<\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Formato<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Carriles el\u00e9ctricos<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Velocidad t\u00edpica<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>QSFP+<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 \u00d7 10 G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>40 G<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>QSFP28<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 \u00d7 25 G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>100G<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>QSFP-DD<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>8 \u00d7 25 G \/ 50 G<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>400 G \/ 800 G<\/strong><\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Nota t\u00e9cnica: La mayor\u00eda de los m\u00f3dulos <strong>de 400 G desplegados utilizan 8 canales de 50 G PAM4<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2666 C\u00f3mo se logra la doble densidad<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472205.htm\">El transceptor QSFP-DD<\/a> introduce una <strong>segunda fila de contactos el\u00e9ctricos de alta velocidad<\/strong> dentro del conector, manteniendo las dimensiones familiares de la jaula QSFP. Esto posibilita:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Alineaci\u00f3n el\u00e9ctrica directa con los SerDes de 8 canales del ASIC de conmutaci\u00f3n<\/p><\/li><li><p>Mayor ancho de banda por puerto sin reducir el n\u00famero de puertos en el panel frontal<\/p><\/li><li><p>Compatibilidad mec\u00e1nica con jaulas QSFP heredadas (con soporte del equipo anfitri\u00f3n)<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2666 Implicaciones arquitect\u00f3nicas<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Duplicar la densidad de canales y adoptar la modulaci\u00f3n PAM4 tiene varias consecuencias a nivel de sistema:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Mayor sensibilidad a la integridad de la se\u00f1al<\/strong> debido al mayor n\u00famero de carriles y a la p\u00e9rdida del canal<\/p><\/li><li><p><strong>DSP y FEC obligatorios<\/strong> para compensar el menor margen de ruido de PAM4<\/p><\/li><li><p><strong>Mayor disipaci\u00f3n de potencia<\/strong>, lo que afecta el dise\u00f1o t\u00e9rmico y de flujo de aire<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Estos factores hacen que la integraci\u00f3n de los m\u00f3dulos de 400 G sea m\u00e1s exigente que la de QSFP28 y requieren un dise\u00f1o cuidadoso de la PCB del host, la alimentaci\u00f3n y la refrigeraci\u00f3n.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u2666 Por qu\u00e9 esta arquitectura es importante<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La arquitectura el\u00e9ctrica de QSFP-DD cubre la brecha entre el ancho de banda en r\u00e1pido crecimiento de los ASIC de conmutaci\u00f3n (\u226512,8 Tbps) y la densidad pr\u00e1ctica del panel frontal. Permite 400 G y senta las bases el\u00e9ctricas para 800 G sin forzar redise\u00f1os mec\u00e1nicos disruptivos.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u21aa\ufe0f\u00a0<\/strong>Tipos de m\u00f3dulos QSFP-DD de 400 G<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP-DD admite m\u00faltiples est\u00e1ndares de interfaz \u00f3ptica optimizados para distintas distancias de transmisi\u00f3n e infraestructuras de fibra.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ecee655e42824b16b812d98802fb28c9.jpg\" alt=\"400G QSFP-DD Module Types\" class=\"wp-image-3281\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ecee655e42824b16b812d98802fb28c9.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ecee655e42824b16b812d98802fb28c9-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ecee655e42824b16b812d98802fb28c9-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ecee655e42824b16b812d98802fb28c9-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ecee655e42824b16b812d98802fb28c9-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Tabla de referencia r\u00e1pida<\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Tipo de m\u00f3dulo<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Tipo de fibra<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Alcance t\u00edpico (dependiente del fabricante)<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Conector t\u00edpico<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>N\u00famero de carriles \/ agregaci\u00f3n<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Uso t\u00edpico<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>400GBASE-SR8<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Multimodo (OM3\/OM4\/OM5)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~100 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>MPO\/MTP (paralelo)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>8 \u00d7 50 G (paralelo)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Enrack, enlaces cortos de hoja\/espina<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>400GBASE-DR4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Monomodo (SMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~500 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>MPO\/MTP o varios conectores LC (seg\u00fan fabricante)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Asignaci\u00f3n de 4 \u00d7 100 G o 8 \u00d7 50 G (dependiente del fabricante)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Interconexi\u00f3n entre racks del centro de datos, agregaci\u00f3n en campus<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>400GBASE-FR4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Monomodo (SMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~2 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>LC (normalmente d\u00faplex por canal o MPO)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 \u00d7 (subagregaciones) \u2014 asignaci\u00f3n PHY seg\u00fan norma<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Enlaces metropolitanos, interconexiones m\u00e1s largas dentro del centro de datos<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>400GBASE-LR4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Monomodo (SMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~10 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>LC (duplex \/ WDM)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 \u03bb WDM o agregaci\u00f3n equivalente<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Borde metropolitano, agregaci\u00f3n regional<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>800GBASE-DR8 \/ FR8<\/strong> (emergente)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Variantes de fibra monomodo (SMF) y multimodo (MMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>DR8: alcance corto a medio similar; FR8: m\u00e1s largo<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>MPO \/ LC (dependiente del fabricante)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>8 \u00d7 100 G o 16 \u00d7 50 G (dependiente del fabricante)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Troncales en hipercalentamiento, tejidos futuros de alta densidad<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Nota:<br><\/strong> Los valores de alcance anteriores son valores t\u00edpicos de planificaci\u00f3n. El alcance real del enlace depende de la potencia \u00f3ptica de transmisi\u00f3n (Tx), la sensibilidad del receptor, el tipo de fibra, las p\u00e9rdidas en conectores\/empalmes y la FEC empleada. Siempre verifique las hojas de datos del fabricante y realice un c\u00e1lculo de presupuesto de enlace para su planta de fibra espec\u00edfica.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >400GBASE-SR8<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Fibra multimodo (MMF)<\/p><\/li><li><p>Interconexiones cortas dentro del centro de datos<\/p><\/li><li><p>Normalmente implementadas con conectores MPO\/MTP<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" ><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/470377.htm\">400GBASE-DR4<\/a><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Fibra monomodo (SMF)<\/p><\/li><li><p>Hasta aproximadamente 500 metros<\/p><\/li><li><p>Com\u00fanmente utilizadas en tejidos de hoja\/espina en hipercalentamiento<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" ><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472000.htm\">400GBASE-FR4<\/a><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Direct Attach Copper (DAC)<\/p><\/li><li><p>Hasta aproximadamente 2 kil\u00f3metros<\/p><\/li><li><p>Utiliza tecnolog\u00eda WDM con conectores LC d\u00faplex<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" ><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472016.htm\">400GBASE-LR4<\/a><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Direct Attach Copper (DAC)<\/p><\/li><li><p>Hasta aproximadamente 10 kil\u00f3metros<\/p><\/li><li><p>Normalmente se utiliza para enlaces de agregaci\u00f3n metropolitana o de campus<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Variantes emergentes de 800 G<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>800GBASE-DR8<\/p><\/li><li><p>800GBASE-FR8<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Estos est\u00e1ndares emergentes ampl\u00edan la capacidad de los m\u00f3dulos de 800 G mediante velocidades de canal PAM4 m\u00e1s altas, aunque los requisitos de potencia y t\u00e9rmicos siguen siendo consideraciones clave de ingenier\u00eda.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u21aa\ufe0f\u00a0<\/strong>QSFP-DD frente a QSFP28 frente a OSFP: potencia, gesti\u00f3n t\u00e9rmica y compatibilidad hacia atr\u00e1s<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Esta secci\u00f3n compara los tres ecosistemas comunes de m\u00f3dulos enchufables de alta velocidad, resume las consecuencias en potencia y gesti\u00f3n t\u00e9rmica al migrar a QSFP-DD\/800G y enumera las restricciones concretas de compatibilidad que los ingenieros deben verificar antes de la implementaci\u00f3n.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/fc5b4b9c7d4441f0b2df6d45bb7bc777.jpg\" alt=\"QSFP-DD vs. QSFP28 vs. OSFP \u2014 Power, Thermal, and Backward-compatibility\" class=\"wp-image-3282\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/fc5b4b9c7d4441f0b2df6d45bb7bc777.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/fc5b4b9c7d4441f0b2df6d45bb7bc777-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/fc5b4b9c7d4441f0b2df6d45bb7bc777-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/fc5b4b9c7d4441f0b2df6d45bb7bc777-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/fc5b4b9c7d4441f0b2df6d45bb7bc777-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Consumo de potencia: rangos t\u00edpicos por m\u00f3dulo<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><em>(utilice las especificaciones m\u00e1ximas del fabricante para la planificaci\u00f3n final de potencia\/fuentes de alimentaci\u00f3n; estos son rangos t\u00edpicos de producci\u00f3n utilizados para la planificaci\u00f3n preliminar de capacidad)<\/em><\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Tipo de m\u00f3dulo<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Potencia t\u00edpica (por m\u00f3dulo)<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>QSFP28 (100 G)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>3,5\u20134,5 W<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>QSFP-DD (400 G)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>~10\u201314 W<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>QSFP-DD (800 G, inicial)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>~16\u201320 W<\/strong><\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Nota de ingenier\u00eda:<\/strong> dise\u00f1e siempre el margen de potencia y t\u00e9rmico del chasis para acomodar <strong>la potencia m\u00e1xima del m\u00f3dulo (especificada por el fabricante),<\/strong> la carga sostenida y los escenarios transitorios (arranque\/tr\u00e1fico pico).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Impactos pr\u00e1cticos de una mayor potencia por puerto<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>La direcci\u00f3n del flujo de aire del switch se vuelve cr\u00edtica.<\/strong> Distintos fabricantes emplean flujo de aire de delante a atr\u00e1s o de atr\u00e1s a delante; la eficacia del enfriamiento del m\u00f3dulo depende de que la ruta t\u00e9rmica del m\u00f3dulo coincida con el flujo de aire del chasis.<\/p><\/li><li><p><strong>La estrategia de ubicaci\u00f3n de los puertos afecta el limitado t\u00e9rmico.<\/strong> Concentrar m\u00f3dulos de alta potencia en puertos adyacentes puede generar puntos calientes y activar el limitado t\u00e9rmico; distribuya los puertos de alta potencia o proporcione refrigeraci\u00f3n adicional.<\/p><\/li><li><p><strong>La supervisi\u00f3n de la temperatura mediante DOM es obligatoria.<\/strong> Integre la telemetr\u00eda DOM\/DDM en el sistema de gesti\u00f3n de red (NMS) para alarmas activas y an\u00e1lisis de tendencias; los umbrales de temperatura deben desencadenar mitigaciones automatizadas (limitaci\u00f3n de tasa, cambios en la velocidad de los ventiladores o reemplazo del m\u00f3dulo).<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Acciones pr\u00e1cticas<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>Utilice la potencia m\u00e1xima del fabricante <strong>para la planificaci\u00f3n del presupuesto de potencia por puerto y para todo el chasis.<\/strong> Realice pruebas en c\u00e1mara t\u00e9rmica con todos los m\u00f3dulos poblados en condiciones de peor caso.<\/p><\/li><li><p>Run thermal chamber tests with fully populated worst-case modules.<\/p><\/li><li><p>Valide las curvas de control del ventilador en condiciones ambientales y de carga sostenida m\u00e1s desfavorables.<\/p><\/li><li><p>Implemente paneles de telemetr\u00eda que correlacionen la potencia del puerto, la temperatura y los recuentos de errores.<\/p><\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" >Compatibilidad hacia atr\u00e1s: qu\u00e9 funciona y qu\u00e9 no<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Las carcasas QSFP-DD son <strong>mec\u00e1nicamente<\/strong> dise\u00f1adas para aceptar factores de forma QSFP anteriores (QSFP+ y QSFP28). Sin embargo:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Ajuste mec\u00e1nico \u2260 compatibilidad funcional.<\/strong> Un m\u00f3dulo QSFP28 insertado en una carcasa QSFP-DD se acoplar\u00e1 f\u00edsicamente, pero el ASIC del host, el trazado de la PCB y el firmware deben admitir la asignaci\u00f3n el\u00e9ctrica y la negociaci\u00f3n de velocidad del m\u00f3dulo anterior.<\/p><\/li><li><p><strong>Los m\u00f3dulos compatibles con versiones anteriores funcionan \u00fanicamente a su velocidad nativa.<\/strong> Un m\u00f3dulo QSFP28 no puede operar m\u00e1gicamente a 400 G cuando se coloca en una carcasa QSFP-DD.<\/p><\/li><li><p><strong>La asignaci\u00f3n el\u00e9ctrica de los canales difiere.<\/strong> La l\u00f3gica de divisi\u00f3n (breakout), el orden y la polaridad de los canales, y la configuraci\u00f3n del SerDes deben ser compatibles con el ASIC del switch y el firmware para un funcionamiento correcto.<\/p><\/li><li><p><strong>Los perfiles de potencia y refrigeraci\u00f3n difieren significativamente.<\/strong> Espere necesidades de refrigeraci\u00f3n por puerto m\u00e1s altas para QSFP-DD\/800 G; las suposiciones anteriores sobre la potencia de QSFP28 pueden ser inv\u00e1lidas al mezclar m\u00f3dulos QSFP28 y QSFP-DD en el mismo chasis.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Lista de verificaci\u00f3n antes de mezclar tipos de m\u00f3dulos<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Confirme que el ASIC del host y el firmware admitan factores de forma mixtos y modos de divisi\u00f3n (breakout).<\/p><\/li><li><p>Verifique que el trazado de la placa y la distribuci\u00f3n de potencia soporten ambas clases de m\u00f3dulos.<\/p><\/li><li><p>Pruebe la inserci\u00f3n y extracci\u00f3n mec\u00e1nicas, as\u00ed como los informes DOM, para cada tipo de m\u00f3dulo admitido.<\/p><\/li><li><p>Actualice el NMS para reconocer y gestionar <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/ddm-dom-in-optical-transceivers\/\">DOM<\/a> registros y umbrales diferentes.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Comparaci\u00f3n r\u00e1pida: QSFP28 frente a QSFP-DD frente a OSFP<\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Caracter\u00edstica<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>QSFP28<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>QSFP-DD<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>OSFP<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Velocidad m\u00e1xima (t\u00edpica)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>100G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>400 G \/ 800 G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>800G<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Canales el\u00e9ctricos<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>8<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>8<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Compatibilidad hacia atr\u00e1s<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>No aplicable (heredado)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Mec\u00e1nico: s\u00ed; Funcional: condicional<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>No (huella mec\u00e1nica diferente)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Margen de potencia<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Limitado<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Medio<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>High<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Ecosistema principal<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Mercado amplio maduro<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Centros de datos hipercalificables (hyperscale) y convencionales<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Hipercalificables (plataformas con alta demanda de potencia)<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Interpretaci\u00f3n:<\/strong> QSFP-DD representa un equilibrio pragm\u00e1tico: ofrece mayor densidad manteniendo la continuidad mec\u00e1nica con gran parte del ecosistema QSFP. OSFP ofrece mayor margen de potencia (preferido por algunos hipercalificables), pero requiere carcasas distintas y espacio diferente en el panel frontal.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Conclusi\u00f3n t\u00e9cnica<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP-DD es la ruta m\u00e1s pragm\u00e1tica para muchos centros de datos para alcanzar 400 G sin un redise\u00f1o mec\u00e1nico completo. Sin embargo, plantea requisitos el\u00e9ctricos, de energ\u00eda y t\u00e9rmicos que<br> <strong>deben<br><\/strong> validarse a nivel de plataforma:<br><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Planifique para<br> <strong>cargas m\u00e1ximas de energ\u00eda<br><\/strong> y t\u00e9rmicas, no para valores t\u00edpicos.<br>.<\/p><\/li><li><p>Trate la compatibilidad mec\u00e1nica como solo el primer paso: valide la<br> <strong>compatibilidad funcional<br><\/strong> (ASIC, firmware, asignaci\u00f3n de canales).<br>.<\/p><\/li><li><p>Integre la telemetr\u00eda DOM y la mitigaci\u00f3n t\u00e9rmica automatizada en las operaciones.<br>.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Si lo desea, puedo elaborar un breve ejemplo pr\u00e1ctico de presupuesto t\u00e9rmico (potencia por chasis y perfil de ventiladores) utilizando una configuraci\u00f3n de 32 \u00d7 400 G QSFP-DD, o generar una lista de verificaci\u00f3n de compatibilidad que pueda entregar a los equipos de validaci\u00f3n de hardware. \u00bfCu\u00e1l le ayudar\u00eda m\u00e1s a continuaci\u00f3n?<br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u21aa\ufe0f\u00a0<\/strong>Escenarios t\u00edpicos de implementaci\u00f3n de QSFP-DD<br><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP-DD se implementa principalmente donde<br> <strong>la densidad de puertos, la escalabilidad del ancho de banda y la compatibilidad hacia adelante<br><\/strong> son cr\u00edticas. A continuaci\u00f3n se presentan los escenarios reales m\u00e1s comunes, con contexto t\u00e9cnico pr\u00e1ctico, no generalidades comerciales.<br>.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6f678a7d06ad4e6ba0bce3da1e30d233.jpg\" alt=\"Typical QSFP-DD Deployment Scenarios\" class=\"wp-image-3283\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6f678a7d06ad4e6ba0bce3da1e30d233.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6f678a7d06ad4e6ba0bce3da1e30d233-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6f678a7d06ad4e6ba0bce3da1e30d233-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6f678a7d06ad4e6ba0bce3da1e30d233-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6f678a7d06ad4e6ba0bce3da1e30d233-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b6 Conmutadores de espina dorsal (spine) en centros de datos hipercalibrados<br><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP-DD es el factor de forma dominante para capas de espina dorsal de 400 G en centros de datos hipercalibrados y grandes nubes.<br>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Habilita un ancho de banda masivo este-oeste entre niveles de hoja (leaf) sin incrementar el n\u00famero de racks<br><\/p><\/li><li><p>Se alinea perfectamente con ASICs de conmutaci\u00f3n de \u226512,8 Tbps y 25,6 Tbps<br><\/p><\/li><li><p>Suele combinarse con \u00f3pticas 400GBASE-DR4 o FR4 seg\u00fan el alcance de la red<br><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Por qu\u00e9 QSFP-DD resulta adecuado:<br><\/strong> alta densidad de puertos, ecosistema estandarizado y continuidad mec\u00e1nica con plataformas basadas en QSFP simplifican la implementaci\u00f3n a gran escala y la gesti\u00f3n de repuestos.<br>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b6 Conmutadores de hoja (leaf) de alto radix (32 \u00d7 400 G o superior)<br><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Los conmutadores de hoja modernos utilizan cada vez m\u00e1s<br> <strong>paneles frontales de QSFP-DD de alto radix<br><\/strong> (por ejemplo, dise\u00f1os de 32 \u00d7 400 G o 64 \u00d7 400 G).<br>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Reduce el n\u00famero de dispositivos de hoja necesarios para la misma capacidad de red<br><\/p><\/li><li><p>Simplifica el cableado y reduce la complejidad operativa<br><\/p><\/li><li><p>Admite modos de divisi\u00f3n (breakout) (p. ej., 400 G \u2192 4 \u00d7 100 G) cuando lo permiten el ASIC y el firmware<br><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Nota de dise\u00f1o:<\/strong> la planificaci\u00f3n de la densidad de potencia y del flujo de aire es esencial, especialmente cuando muchos puertos adyacentes est\u00e1n ocupados con m\u00f3dulos de \u226512 W.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b6 Cl\u00fasteres de IA \/ HPC que requieren un ancho de banda denso este-oeste<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Entrenamiento de IA y <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/what-is-hpc-high-performance-computing\/\">HPC<\/a> Las cargas de trabajo generan un tr\u00e1fico este-oeste extremadamente alto, lo que convierte a QSFP-DD en una opci\u00f3n natural.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Admite tejidos de alto ancho de banda y baja latencia para cl\u00fasteres de GPU\/acceleradores<\/p><\/li><li><p>Se utiliza com\u00fanmente con \u00f3pticas de corto alcance DR4 o SR8 dentro de los pods de IA<\/p><\/li><li><p>Proporciona una ruta de migraci\u00f3n hacia 800 G sin cambiar el factor de forma mec\u00e1nico<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Consideraci\u00f3n operativa:<\/strong> Los ajustados m\u00e1rgenes t\u00e9rmicos y la alta utilizaci\u00f3n sostenida requieren un monitoreo proactivo de la temperatura mediante DOM y una validaci\u00f3n rigurosa del enfriamiento.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b6 Agregaci\u00f3n central con \u00f3pticas DR4 \/ FR4<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP-DD tambi\u00e9n se utiliza ampliamente en capas centrales o de agregaci\u00f3n donde los enlaces de 400 G consolidan m\u00faltiples conexiones de menor velocidad.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>DR4 (~500 m) es adecuado para campus grandes o centros de datos multi-sala<\/p><\/li><li><p>FR4 (~2 km) permite la agregaci\u00f3n metropolitana adyacente sin \u00f3pticas coherentes<\/p><\/li><li><p>Reduce la cantidad de fibras y la complejidad de puertos comparado con m\u00faltiples enlaces de 100 G<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Consejo de planificaci\u00f3n:<\/strong> Valide siempre los presupuestos de enlace y los requisitos de correcci\u00f3n de errores (FEC), especialmente para FR4 y alcances m\u00e1s largos, para evitar enlaces marginales a escala.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b6 Resumen de implementaci\u00f3n (cu\u00e1ndo tiene sentido usar QSFP-DD)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP-DD es ideal para entornos que requieren:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Ancho de banda de 400 G por puerto hoy, con una ruta hacia 800 G<\/p><\/li><li><p>Alta densidad en el panel frontal sin redise\u00f1o mec\u00e1nico<\/p><\/li><li><p>\u00d3pticas estandarizadas en las capas de espina (spine), hoja (leaf) y agregaci\u00f3n<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Para plataformas de menor densidad o con restricciones de potencia, QSFP28 puede seguir siendo suficiente. Para dise\u00f1os hipercalculables de potencia ultraelevada, se podr\u00eda considerar OSFP; no obstante, QSFP-DD sigue siendo la opci\u00f3n m\u00e1s equilibrada y ampliamente adoptada en toda la industria.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u21aa\ufe0f\u00a0<\/strong>Buenas pr\u00e1cticas para la selecci\u00f3n e implementaci\u00f3n de QSFP-DD<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Seleccionar e implementar m\u00f3dulos QSFP-DD no es solo una decisi\u00f3n de velocidad, sino un ejercicio de ingenier\u00eda a nivel de sistema que involucra \u00f3pticas, capacidad del ASIC, energ\u00eda, dise\u00f1o t\u00e9rmico y operabilidad a largo plazo. Las pr\u00e1cticas siguientes reflejan lo que consistentemente funciona en implementaciones reales de centros de datos y de IA\/HPC.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b03664ba26524d55bb331989b63823b4.jpg\" alt=\"QSFP-DD Modules Selection and Deployment\" class=\"wp-image-3284\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b03664ba26524d55bb331989b63823b4.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b03664ba26524d55bb331989b63823b4-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b03664ba26524d55bb331989b63823b4-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b03664ba26524d55bb331989b63823b4-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/b03664ba26524d55bb331989b63823b4-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Comience con el enlace, no con el m\u00f3dulo<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Seleccione siempre el est\u00e1ndar \u00f3ptico seg\u00fan el alcance y la infraestructura de fibra, y luego elija uno compatible <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472197.htm\">\ud83d\udca1 Conclusi\u00f3n: Elige el Herramienta Correcta para el Trabajo<\/a>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>\u2264100 m, MMF disponible:<\/strong> 400GBASE-SR8<\/p><\/li><li><p><strong>\u2264500 m, SMF:<\/strong> 400GBASE-DR4<\/p><\/li><li><p><strong>\u22642 km, SMF:<\/strong> 400GBASE-FR4<\/p><\/li><li><p><strong>\u226410 km, SMF:<\/strong> 400GBASE-LR4<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Mejor pr\u00e1ctica:<\/strong> realice un presupuesto formal de enlace utilizando los valores m\u00ednimos de transmisi\u00f3n (Tx) y m\u00e1ximos de recepci\u00f3n (Rx) del fabricante, las p\u00e9rdidas de conectores\/empalmes y un margen de ingenier\u00eda \u22652\u20133 dB.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Verifique el soporte del ASIC y el firmware del host<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472199.htm\">M\u00f3dulo 400G<\/a> la funcionalidad depende en gran medida de las capacidades del lado del host.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Confirme lo siguiente antes de la compra o implementaci\u00f3n:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Velocidades el\u00e9ctricas por canal admitidas (8 \u00d7 50G PAM4 frente a modos heredados)<\/p><\/li><li><p>Opciones admitidas de divisi\u00f3n (por ejemplo, 400G \u2192 4 \u00d7 100G)<\/p><\/li><li><p>Tipos de correcci\u00f3n de errores (FEC) requeridos y valores predeterminados<\/p><\/li><li><p>Compatibilidad de registros DOM\/DDM y reporte de telemetr\u00eda<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Lecci\u00f3n pr\u00e1ctica:<\/strong> muchos \u201cproblemas de compatibilidad\u201d son limitaciones de firmware, no fallos \u00f3pticos.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Dise\u00f1e para la carga m\u00e1xima de potencia y t\u00e9rmica<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Los m\u00f3dulos QSFP-DD operan a <strong>una potencia significativamente mayor<\/strong> que los QSFP28.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Presupueste utilizando la <strong>potencia nominal m\u00e1xima<\/strong>, no los valores t\u00edpicos<\/p><\/li><li><p>Valide la direcci\u00f3n del flujo de aire (frontal-a-posterior vs posterior-a-frontal)<\/p><\/li><li><p>Evite agrupar \u00f3pticas de alta potencia en puertos adyacentes<\/p><\/li><li><p>Confirme las curvas de los ventiladores y las alarmas t\u00e9rmicas bajo tr\u00e1fico sostenido<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Regla pr\u00e1ctica:<\/strong> si una plataforma es estable en reposo pero falla bajo carga, el margen t\u00e9rmico es insuficiente.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Trate la compatibilidad inversa como condicional<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Aunque las bah\u00edas QSFP-DD <strong>aceptan mec\u00e1nicamente QSFP+\/QSFP28<\/strong>, la compatibilidad funcional no est\u00e1 garantizada.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Los m\u00f3dulos retrocompatibles operan \u00fanicamente a su velocidad nativa<\/p><\/li><li><p>La asignaci\u00f3n de canales y la polaridad deben ser compatibles con el switch<\/p><\/li><li><p>Las implementaciones mixtas requieren una validaci\u00f3n cuidadosa del firmware<\/p><\/li><li><p>Las suposiciones de refrigeraci\u00f3n difieren entre \u00f3pticas de 100G y 400G<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Mejor pr\u00e1ctica:<\/strong> pruebe configuraciones mixtas de m\u00f3dulos en un entorno de preproducci\u00f3n antes del despliegue en producci\u00f3n.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Estandarice las \u00f3pticas para reducir la complejidad operativa<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A escala, la coherencia importa m\u00e1s que la flexibilidad te\u00f3rica.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Limite el n\u00famero de referencias (SKUs) de m\u00f3dulos por clase de alcance<\/p><\/li><li><p>Estandarice los tipos de conectores (MPO frente a LC) por capa<\/p><\/li><li><p>Alinee la selecci\u00f3n de proveedores con el soporte, la frecuencia de actualizaci\u00f3n del firmware y la confiabilidad en los plazos de entrega<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Esto reduce los requisitos de repuestos, el tiempo de resoluci\u00f3n de incidencias y los errores en campo.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Haga del monitoreo DOM una parte de las operaciones, no solo de los diagn\u00f3sticos<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La telemetr\u00eda DOM\/DDM debe monitorearse continuamente, no solo verificarse durante fallos.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Supervisar, como m\u00ednimo:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Temperatura del m\u00f3dulo<\/p><\/li><li><p>Potencia \u00f3ptica de transmisi\u00f3n\/recepci\u00f3n (Tx\/Rx)<\/p><\/li><li><p>Tensi\u00f3n de alimentaci\u00f3n y corriente de polarizaci\u00f3n<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Informaci\u00f3n pr\u00e1ctica:<\/strong> los datos DOM en tendencia suelen revelar la degradaci\u00f3n de la fibra o problemas de refrigeraci\u00f3n <strong>semanas antes del fallo del enlace<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Planificar la escalabilidad futura (400G \u2192 800G)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Incluso si hoy se despliega 400G, planifique teniendo en cuenta la siguiente generaci\u00f3n.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Confirme la preparaci\u00f3n de la carcasa y los conectores para m\u00f3dulos de mayor potencia<\/p><\/li><li><p>Valide los m\u00e1rgenes de potencia y flujo de aire para las \u00f3pticas QSFP-DD de 800G iniciales<\/p><\/li><li><p>Evite quedar bloqueado con \u00f3pticas que impidan futuras actualizaciones de velocidad por canal<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ventaja estrat\u00e9gica:<\/strong> <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472195.htm\">M\u00f3dulos QSFP-DD de 400 G<\/a> permite una escalabilidad incremental sin rehacer la mec\u00e1nica del panel frontal.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Lista de comprobaci\u00f3n para el despliegue<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u2705 El est\u00e1ndar \u00f3ptico coincide con el alcance y la planta de fibra<\/p><\/li><li><p>\u2705 El presupuesto del enlace se ha validado con margen<\/p><\/li><li><p>\u2705 Se ha confirmado la compatibilidad del ASIC host y el firmware<\/p><\/li><li><p>\u2705 Se ha verificado el margen de potencia y t\u00e9rmico a carga total<\/p><\/li><li><p>\u2705 Se han probado escenarios con m\u00f3dulos mixtos<\/p><\/li><li><p>\u2705 La telemetr\u00eda DOM se ha integrado en el sistema de gesti\u00f3n de red (NMS)<\/p><\/li><li><p>\u2705 Se ha considerado la ruta de actualizaci\u00f3n a 800G<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u21aa\ufe0f\u00a0<\/strong>400G<strong> <\/strong>Preguntas frecuentes sobre transceptores QSFP-DD<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/abf63f48159943f1b0297288f28a4659.jpg\" alt=\"400G QSFP-DD Transceiver FAQs\" class=\"wp-image-3285\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/abf63f48159943f1b0297288f28a4659.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/abf63f48159943f1b0297288f28a4659-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/abf63f48159943f1b0297288f28a4659-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/abf63f48159943f1b0297288f28a4659-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/abf63f48159943f1b0297288f28a4659-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >P1: \u00bfQu\u00e9 significa QSFP-DD?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP-DD significa <strong>\u00abQuad Small Form-factor Pluggable \u2013 Double Density\u00bb<\/strong>, en referencia a su recuento duplicado de canales el\u00e9ctricos.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >P2: \u00bfEs lo mismo QSFP-DD que QSFP56-DD?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP56-DD es una variante inicial de denominaci\u00f3n. En la pr\u00e1ctica, ambos t\u00e9rminos se refieren a QSFP-DD que soporta <strong>canales de 50G PAM4<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >P3: \u00bfPuede QSFP-DD soportar 800G?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00ed. Los primeros m\u00f3dulos <strong>QSFP-DD de 800G<\/strong> utilizan <strong>8 \u00d7 100G PAM4<\/strong>, aunque las restricciones de potencia y t\u00e9rmicas siguen siendo un desaf\u00edo.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >P4: \u00bfRequiere QSFP-DD una nueva infraestructura de fibra?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No siempre. DR4 y FR4 reutilizan <strong>fibra monomodo existente<\/strong>, aunque el tipo de conector (MPO frente a LC) puede cambiar.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >P5: \u00bfEs adecuado QSFP-DD para redes empresariales?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Generalmente no. QSFP-DD est\u00e1 dirigido a <strong>centros de datos hipercalificados y agregaci\u00f3n de clase operadora<\/strong>, no a redes de acceso empresarial t\u00edpicas.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u21aa\ufe0f\u00a0<\/strong>Conclusi\u00f3n y recomendaciones finales sobre QSFP-DD<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP-DD ha surgido como el <strong>factor de forma principal para 400G<\/strong> no porque sea simplemente m\u00e1s r\u00e1pido que QSFP28, sino porque posibilita un <strong>cambio significativo en la densidad de ancho de banda<\/strong> sin ampliar el espacio f\u00edsico disponible en el panel frontal del switch. Al duplicar la interfaz el\u00e9ctrica hasta ocho canales, QSFP-DD alinea la capacidad \u00f3ptica con el crecimiento de ancho de banda de los ASIC de switch de pr\u00f3xima generaci\u00f3n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dicho esto, QSFP-DD introduce <strong>nuevas restricciones de ingenier\u00eda<\/strong>. Una mayor densidad de canales, la se\u00f1alizaci\u00f3n PAM4 y un aumento de la potencia por puerto modifican fundamentalmente las prioridades de implementaci\u00f3n hacia <strong>integridad de se\u00f1al, dise\u00f1o t\u00e9rmico, madurez del firmware y validaci\u00f3n de la plataforma<\/strong>. Tratar el m\u00f3dulo de 400 G como un reemplazo directo, en lugar de una actualizaci\u00f3n a nivel de sistema, es una causa frecuente de inestabilidad en las primeras implementaciones.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>QSFP-DD permite 400 G y m\u00e1s<\/strong> sin aumentar la huella frontal<\/p><\/li><li><p><strong>PAM4 y una mayor densidad de canales<\/strong> reducen los m\u00e1rgenes de integridad de se\u00f1al y t\u00e9rmicos<\/p><\/li><li><p><strong>La compatibilidad con versiones anteriores es mec\u00e1nica<\/strong>, no funcional de forma autom\u00e1tica<\/p><\/li><li><p><strong>Las pruebas de interoperabilidad y validaci\u00f3n<\/strong> son esenciales para redes de producci\u00f3n<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Recomendaciones finales<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Los ingenieros que eval\u00faen m\u00f3dulos QSFP-DD deben:<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p><strong>Comenzar con la plataforma de conmutaci\u00f3n<\/strong>, no con el transceptor \u00f3ptico: verificar el soporte del ASIC, la direcci\u00f3n del flujo de aire y el presupuesto de potencia<\/p><\/li><li><p><strong>Validar en condiciones de peor caso<\/strong>, incluida la ocupaci\u00f3n completa de puertos y tr\u00e1fico sostenido<\/p><\/li><li><p><strong>Estandarizar las arquitecturas de transceptores \u00f3pticos y cableado<\/strong> para reducir la complejidad operativa<\/p><\/li><li><p><strong>Supervisar activamente la telemetr\u00eda DOM<\/strong>, especialmente la temperatura y la potencia \u00f3ptica<\/p><\/li><li><p><strong>Planificar la escalabilidad futura<\/strong>, asegurando que las decisiones actuales de 400 G no limiten las hojas de ruta de 800 G<\/p><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP-DD no es simplemente un QSFP m\u00e1s r\u00e1pido; representa un cambio fundamental en la estrategia de densidad de puertos para centros de datos modernos, cl\u00fasteres de IA y redes de clase operadora. El \u00e9xito depende menos de la velocidad nominal y m\u00e1s de la compatibilidad a nivel de sistema y la disciplina operativa.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Explore las soluciones QSFP-DD de LINK-PP<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/595d3d91035047359fb2f83f161c38d1.jpg\" alt=\" LINK-PP 400G QSFP-DD Transceiver\" class=\"wp-image-3286\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/595d3d91035047359fb2f83f161c38d1.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/595d3d91035047359fb2f83f161c38d1-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/595d3d91035047359fb2f83f161c38d1-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/595d3d91035047359fb2f83f161c38d1-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/595d3d91035047359fb2f83f161c38d1-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Para validado <strong>QSFP-DD <\/strong><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/470377.htm\"><strong>m\u00f3dulo \u00f3ptico de 400 G<\/strong><\/a> dise\u00f1ado para arquitecturas spine\u2013leaf, cl\u00fasteres de IA\/HPC y agregaci\u00f3n de alta densidad, visite el <a target=\"_self\" href=\"https:\/\/www.l-p.com\/\"><strong>Tienda oficial de LINK-PP<\/strong>.<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">LINK-PP proporciona especificaciones detalladas, orientaci\u00f3n sobre compatibilidad y transceptores \u00f3pticos QSFP-DD listos para producci\u00f3n, para respaldar implementaciones confiables y a gran escala.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >V\u00e9ase tambi\u00e9n<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/qsfp-dd-optical-transceivers-faster-connections\/\">Transceptores \u00f3pticos QSFP-DD que habilitan conexiones de alta velocidad<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/the-benefits-of-100g-sfp-dd-lr-optical-transceiver\/\">Ventajas del uso del transceptor SFP-DD de 100 G LR<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/100g-sfp-dd-transceivers-high-density-networks\/\">Mejora de redes de alta densidad con transceptores SFP-DD de 100 G<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/cfp-vs-qsfp28-transceivers-comparison\/\">Comparaci\u00f3n entre CFP y QSFP28 en el debate sobre transceptores de 100 G<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/products\/qsfp-dd-lr4-transceiver-400g-10km-solution\/\">LINK-PP LQD-CW400-LR4C: soluci\u00f3n QSFP-DD de 400 G para 10 km<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>\u00bfQu\u00e9 es QSFP-DD? QSFP-DD permite Ethernet de alta velocidad con doble densidad, compatibilidad hacia atr\u00e1s y ancho de banda de hasta 800 G para centros de datos modernos.<\/p>","protected":false},"author":1,"featured_media":3287,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[17],"class_list":["post-3288","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-400g-optical-modules"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/3288","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/comments?post=3288"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/3288\/revisions"}],"predecessor-version":[{"id":10778,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/3288\/revisions\/10778"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/media\/3287"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/media?parent=3288"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/categories?post=3288"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/tags?post=3288"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}